Back to Authors

Shah, Raj J.

https://orcid.org/0000-0002-9736-4139

Mayo Clinic

University of Colorado Anschutz

Citations 6

The Success and Safety of Endoscopic Retrograde Cholangiopancreatography in Surgically Altered Gastrointestinal Anatomy
Han, Samuel , Edmundowicz, Steven A. , Attwell, Augustin , Hammad, Hazem, Wani, Sachin , Edmundowicz, Steven A , Kolb, Jennifer M. , Shah, Raj J.

Medical Sciences | February 11, 2025 | Volume: 13 | Issue: 1 | Pages: 18

10.3390/medsci13010018 Get It

Background/Objectives: Performing endoscopic retrograde cholangiopancreatography (ERCP) in surgically altered gastrointestinal anatomy remains challenging, frequently necessitating the use of forward-viewing endoscopes. Given the challenge in endoscope selection based on the type of altered anatomy, the aim of this study was to examine ERCP success rates by specific endoscopes for different anatomy types. Methods: This single-center retrospective study examined ERCPs performed in patients with surgically altered gastrointestinal anatomy during an 18-year period. Enteroscopy success, cannulation success, and intervention success rates were compared between the different anatomy and endoscope types. Results: This study included a total of 334 adult patients (665 total ERCPs) with altered anatomy. The pediatric colonoscope was most frequently utilized (32.2%), and the majority of procedures were performed for biliary indications. Enteroscopy success was 82.2% in Roux-en-Y gastric bypass (RYGB), 97% in Billroth II, 91.5% in Whipple, and 93.2% in Roux-en-Y hepaticojejunostomy (RYHJ). Cannulation success was 90.5% in RYGB, 90.5% in Billroth II, 83.6% in Whipple, and 90.6% in RYHJ. Intervention success was 88.2% in Billroth II, 65.1% in RYGB, 81.6% in Whipple, and 87.5% in RYHJ. In patients with RYGB and RYHJ, SBE was utilized most frequently, with rotational enteroscopy having the highest success rates. The overall adverse event rate was 5.1%, with the majority of these being mild in severity. Conclusions: This large retrospective study found ERCP with forward-viewing endoscopes to be safe and effective for a variety of surgically altered anatomy types. Despite recent advances seen with endoscopic ultrasound-guided drainage procedures, this study advocates for ERCP as the initial approach for pancreaticobiliary access in surgically altered anatomy.
Technical Factors Associated With the Benefit of Prophylactic Pancreatic Stent Placement During High-Risk Endoscopic Retrograde Cholangiopancreatography: A Secondary Analysis of the SVI Trial Data Set
Elmunzer, B. Joseph , Zhang, Jingwen , Coté, Gregory A. , Wani, Sachin , Shah, Raj J. , Bang, Ji Young , Varadarajulu, Shyam , Singh, Vikesh K. , Khashab, Mouen A. , Kwon, Richard S. , Scheiman, James M., Keilin, Steven , Chak, Amitabh , Slivka, Adam, Mullady, Daniel , Kushnir, Vladimir , Buxbaum, James , Keswani, Rajesh N. , Gardner, Timothy B. , Forbes, Nauzer , Rastogi, Amit, Ross, Andrew S., Law, Joanna K. , Chen, Yen‐I , Smith, Zachary L. , Petersen, Bret T. , Wang, Andrew Y. , Saltzman, John R. , Spitzer, Rebecca L., Ordiah, Collins, Spino, Cathie , Foster, Lydia D. , Durkalski‐Mauldin, Valerie, Group*, on behalf of the SVI Study, Shah, Raj , Singh, Vikesh K , Kwon, Richard S , Willingham, Field F , Chak, Amitabh , Mullady, Daniel , Forbes, Nauzer , Ross, Andrew , Law, Joanna , Chen, Yen-I , Smith, Zachary L , Serrano, Jose , Petersen, Bret, Wang, Andrew Y , Saltzman, John R , Spino, Cathie , Foster, Lydia D , Edmundowicz, Steven A. , Willingham, Field F. , Papachristou, Georgios I. , Yachimski, Patrick , Barkun, Alan , Serrano, José , Group*, on behalf of the SVI Study

American Journal of Gastroenterology | August 27, 2024 | Volume: 120 | Issue: 4 | Pages: 811-815

10.14309/ajg.0000000000003052 Get It

INTRODUCTION: Prophylactic pancreatic stent placement (PSP) is effective for preventing pancreatitis after endoscopic retrograde cholangiopancreatography (ERCP) in high-risk cases, but the optimal technical approach to this intervention remains uncertain. METHODS: In this secondary analysis of 787 clinical trial patients who underwent successful stent placement, we studied the impact of (i) whether pancreatic wire access was achieved for the sole purpose of PSP or naturally during the conduct of the case, (ii) the amount of effort expended on PSP, (iii) stent length, (iv) stent diameter, and (v) guidewire caliber. We used logistic regression models to examine the adjusted association between each technical factor and post-ERCP pancreatitis (PEP). RESULTS: Ninety-one of the 787 patients experienced PEP. There was no clear association between PEP and whether pancreatic wire access was achieved for the sole purpose of PSP (vs occurring naturally; odds ratio [OR] 0.82, 95% confidence interval [CI] 0.37–1.84), whether substantial effort expended on stent placement (vs nonsubstantial effort; OR 1.58, 95% CI 0.73–3.45), stent length (>5 vs ≤5 cm; OR 1.01, 95% CI 0.63–1.61), stent diameter (≥5 vs <5 Fr; OR 1.13, 95% CI 0.65–1.96), or guidewire caliber (0.035 vs 0.025 in; 0.83, 95% CI 0.49–1.41). DISCUSSION: The 5 modifiable technical factors studied in this secondary analysis of large-scale randomized trial data did not appear to have a strong impact on the benefit of prophylactic PSP in preventing PEP after high-risk ERCP. Within the limitations of post hoc subgroup analysis, these findings may have important implications in procedural decision making and suggest that the benefit of PSP is robust to variations in technical approach.
Endoscopic Ultrasound-guided Transluminal Gallbladder Drainage in Patients With Acute Cholecystitis
Irani, Shayan , Sharma, Neil , Chahal, Prabhleen , Baron, Todd H. , Kozarek, Richard A. , Peetermans, Joyce , McMullen, Edmund, Ho, Evelyne, Merwe, Van der , Storm, Andrew C. , Shah, Raj J. , Willingham, Field F. , Swanström, Lee L. , Shlomovitz, Eran

Annals of Surgery | December 20, 2022 | Volume: 278 | Issue: 3 | Pages: e556-e562

10.1097/sla.0000000000005784 Get It

Objective: To evaluate the safety and efficacy of endoscopic ultrasound-guided gallbladder drainage (EUS-GBD) using a lumen-apposing metal stent (LAMS). Background: For patients with acute cholecystitis who are poor surgical candidates, EUS-GBD using a LAMS is an important treatment alternative to percutaneous gallbladder drainage. Methods: We conducted a regulatory-compliant, prospective multicenter trial at 7 tertiary referral centers in the United States of America and Belgium. Thirty consecutive patients with mild or moderate acute cholecystitis who were not candidates for cholecystectomy were enrolled between September 2019 and August 2021. Eligible patients had a LAMS placed transmurally with 30 to 60-day indwell if removal was clinically indicated, and 30-day follow-up post-LAMS removal. Endpoints included days until acute cholecystitis resolution, reintervention rate, acute cholecystitis recurrence rate, and procedure-related adverse events (AEs). Results: Technical success was 93.3% (28/30) for LAMS placement and 100% for LAMS removal in 19 patients for whom removal was attempted. Five (16.7%) patients required reintervention. Mean time to acute cholecystitis resolution was 1.6±1.5 days. Acute cholecystitis symptoms recurred in 10.0% (3/30) after LAMS removal. Five (16.7%) patients died from unrelated causes. Procedure-related AEs were reported to the FDA in 30.0% (9/30) of patients, including one fatal event 21 days after LAMS removal; however, no AEs were causally related to the LAMS. Conclusions: For selected patients with acute cholecystitis who are at elevated surgical risk, EUS-GBD with LAMS is an alternative to percutaneous gallbladder drainage. It has high technical and clinical success, with low recurrence and an acceptable AE rate. Clinicaltrials.gov, Number: NCT03767881.
Use of probe‐based confocal laser endomicroscopy (pCLE) in gastrointestinal applications. A consensus report based on clinical evidence
Wang, Kenneth K. , Carr‐Locke, David L. , Singh, Satish K. , Neumann, Helmut , Bertani, Helga , Galmiche, Jean-Paul, Arsenescu, Razvan, Caillol, Fabrice , Chang, Kenneth J. , Chaussade, Stanislas, Coron, Emmanuel , Dlugosz, Aldona , Gan, S. Ian , Giovannini, Marc, Gress, Frank G., Haluszka, Oleh, Kahaleh, Michel , Konda, Vani J. , Prat, Frédéric, Sharma, Prateek , Slivka, Adam, Wolfsen, Herbert C. , Zfass, Alvin M., Costamagna, Guido , Ho, Khek Yu , Shah, Raj J. , Kahaleh, Michel

United European Gastroenterology Journal | January 14, 2015 | Volume: 3 | Issue: 3 | Pages: 230-254

10.1177/2050640614566066 Get It

Background Probe‐based confocal laser endomicroscopy (pCLE) provides microscopic imaging during an endoscopic procedure. Its introduction as a standard modality in gastroenterology has brought significant progress in management strategies, affecting many aspects of clinical care and requiring standardisation of practice and training. Objective This study aimed to provide guidance on the standardisation of its practice and training in Barrett's oesophagus, biliary strictures, colorectal lesions and inflammatory bowel diseases. Methods Initial statements were developed by five group leaders, based on the available clinical evidence. These statements were then voted and edited by the 26 participants, using a modified Delphi approach. After two rounds of votes, statements were validated if the threshold of agreement was higher than 75%. Results Twenty‐six experts participated and, among a total of 77 statements, 61 were adopted (79%) and 16 were rejected (21%). The adoption of each statement was justified by the grade of evidence. Conclusion pCLE should be used to enhance the diagnostic arsenal in the evaluation of these indications, by providing microscopic information which improves the diagnostic performance of the physician. In order actually to implement this technology in the clinical routine, and to ensure good practice, standardised initial and continuing institutional training programmes should be established.
Interobserver Agreement for Single Operator Choledochoscopy Imaging: Can We Do Better?
Sethi, Amrita , Doukides, Theodore , Sejpal, Divyesh V., Pleskow, Douglas K. , Slivka, Adam, Itoi, Takao , Petersen, Bret T. , Gress, Frank G., Gaidhane, Monica , Kahaleh, Michel , Kahaleh, Michel , Adler, Douglas G. , Shah, Raj J. , Edmundowicz, Steven A. , Petersen, Bret T. , Pleskow, Douglas

Diagnostic and Therapeutic Endoscopy | October 8, 2014 | Volume: 2014 | Issue: No issue available | Pages: 1-4

10.1155/2014/730731 Get It

Background. The SpyGlass Direct Visualization System (Boston Scientific, Natick, MA) is routinely used during single operator choledochoscopy (SOC) to identify biliary lesions or strictures with a diagnostic accuracy up to 88%. The objective of this study was to determine the interobserver agreement (IOA) of modified scoring criteria for diagnosing biliary lesions/strictures. Methods. 27 SPY SOC video clips were reviewed and scored by 9 interventional endoscopists based on published criteria that included the presence and severity of surface structure, vasculature visualization, lesions, and findings. Results. Overall IOA was “slight” for all variables. The K statistics are as follows: surface (K=0.12, SE = 0.02); vessels (K=0.14, SE = 0.02); lesions (K=0.11, SE = 0.02); findings (K=0.08, SE = 0.03); and final diagnosis (K=0.08, SE = 0.02). The IOA for “findings” and “final diagnosis” was also only “slight.” The final diagnosis was malignant (11), benign (11), and indeterminate (5). Conclusion. IOA using the modified criteria of SOC images was slight to almost poor. The average accuracy was less than 50%. These findings reaffirm that imaging criteria for benign and malignant biliary pathology need to be formally established and validated.
A Multicenter, Prospective Study of a New Fully Covered Expandable Metal Biliary Stent for the Palliative Treatment of Malignant Bile Duct Obstruction
Petersen, Bret T. , Kahaleh, Michel , Kozarek, Richard A. , Loren, David E. , Gupta, Kapil , Kowalski, Thomas E., Freeman, Martin L. , Chen, Yang K., Branch, M. Stanley, Edmundowicz, Steven A. , Glück, Michael , Binmoeller, Kenneth F., Baron, Todd H. , Kinney, Timothy P., Ross, William A., Jowell, Paul S., Carr‐Locke, David L. , Shah, Raj J. , Kahaleh, Michel , Edmundowicz, Steven A

Gastroenterology Research and Practice | March 27, 2013 | Volume: 2013 | Issue: No issue available | Pages: 1-7

10.1155/2013/642428 Get It

Background and Study Aims. Endoscopic placement of self-expanding metal stents (SEMSs) is indicated for palliation of inoperable malignant biliary obstruction. A fully covered biliary SEMS (WallFlex Biliary RX Boston Scientific, Natick, USA) was assessed for palliation of extrahepatic malignant biliary obstruction.Patients and Methods. 58 patients were included in this prospective, multicenter series conducted under an FDA-approved IDE. Main outcome measurements included (1) absence of stent occlusion within six months or until death, whichever occurred first and (2) technical success, need for reintervention, bilirubin levels, stent patency, time to stent occlusion, and adverse events.Results. Technical success was achieved in 98% (57/58), with demonstrated acute removability in two patients. Adequate clinical palliation until completion of followup was achievedin 98% (54/55) ofevaluablepatients, with 1 reintervention due to stent obstruction after 142 days. Mean total bilirubin decreased from 8.9 mg/dL to 1.2 mg/dL at 1 month. Device-related adverse events were limited and included 2 cases of cholecystitis. One stent migrated following radiation therapy.Conclusions. The WallFlex Biliary fully covered stent yielded technically successful placement with uncomplicated acute removal where required, appropriate reduction in bilirubin levels, and low rates of stent migration and occlusion. This SEMS allows successful palliation of malignant extrahepatic biliary obstruction.