Abstract The environmental impact of computer-aided diagnosis (CADx) in colonoscopy is unknown. The potential to reduce greenhouse gas emissions by limiting unnecessary polypectomies may be offset by emissions associated with CADx devices. We quantified and compared the carbon footprint of colonoscopy with and without CADx. Life-cycle carbon emissions associated with endoscopic snares, polyp traps, histopathology, and CADx devices were estimated using life-cycle assessment software. The effect of CADx was estimated by the carbon dioxide equivalent (CO2e) emissions related to outcomes from a prospective cohort of patients who underwent colonoscopy with optical diagnosis under a leave-in-situ strategy (i.e. rectosigmoid polyps ≤5 mm predicted as non-neoplastic were not removed) with and without CADx assistance. We analyzed 1134 individuals (median age 67 years, 59% male) with 1716 colorectal polyps. Colonoscopy with CADx reduced the number of snares and polyp traps from 567 to 543 (difference: 24) and histopathology submissions from 1343 to 1278 (difference: 65). However, the total carbon footprint increased from 832 kg CO2e (95%CI 815 to 847) without CADx to 946 kg CO2e (95%CI 927 to 965) with CADx, corresponding to an absolute increase of 114 kg CO2e (95%CI 80 to 150) or 0.10 kg CO2e per colonoscopy. Using CADx under a leave-in-situ strategy increased the environmental burden of colonoscopy.
Technical Factors Associated With the Benefit of Prophylactic Pancreatic Stent Placement During High-Risk Endoscopic Retrograde Cholangiopancreatography: A Secondary Analysis of the SVI Trial Data Set
INTRODUCTION: Prophylactic pancreatic stent placement (PSP) is effective for preventing pancreatitis after endoscopic retrograde cholangiopancreatography (ERCP) in high-risk cases, but the optimal technical approach to this intervention remains uncertain. METHODS: In this secondary analysis of 787 clinical trial patients who underwent successful stent placement, we studied the impact of (i) whether pancreatic wire access was achieved for the sole purpose of PSP or naturally during the conduct of the case, (ii) the amount of effort expended on PSP, (iii) stent length, (iv) stent diameter, and (v) guidewire caliber. We used logistic regression models to examine the adjusted association between each technical factor and post-ERCP pancreatitis (PEP). RESULTS: Ninety-one of the 787 patients experienced PEP. There was no clear association between PEP and whether pancreatic wire access was achieved for the sole purpose of PSP (vs occurring naturally; odds ratio [OR] 0.82, 95% confidence interval [CI] 0.37–1.84), whether substantial effort expended on stent placement (vs nonsubstantial effort; OR 1.58, 95% CI 0.73–3.45), stent length (>5 vs ≤5 cm; OR 1.01, 95% CI 0.63–1.61), stent diameter (≥5 vs <5 Fr; OR 1.13, 95% CI 0.65–1.96), or guidewire caliber (0.035 vs 0.025 in; 0.83, 95% CI 0.49–1.41). DISCUSSION: The 5 modifiable technical factors studied in this secondary analysis of large-scale randomized trial data did not appear to have a strong impact on the benefit of prophylactic PSP in preventing PEP after high-risk ERCP. Within the limitations of post hoc subgroup analysis, these findings may have important implications in procedural decision making and suggest that the benefit of PSP is robust to variations in technical approach.
Expert endoscopist assessment of colorectal polyp size using virtual scale endoscopy, visual or snare-based estimation: a prospective video-based study