Performance measures for colonoscopy in inflammatory bowel disease patients: European Society of Gastrointestinal Endoscopy (ESGE) Quality Improvement Initiative
AbstractThe European Society of Gastrointestinal Endoscopy (ESGE) presents a short list of performance measures for colonoscopy in inflammatory bowel disease (IBD) patients. Current performance measures for colonoscopy mainly focus on detecting (pre)malignant lesions. However, these performance measures are not relevant for all colonoscopy indications in IBD patients. Therefore, our aim was to provide endoscopy services across Europe and other interested countries with a tool for quality monitoring and improvement in IBD colonoscopy. Eight key performance measures and one minor performance measure were recommended for measurement and evaluation in daily endoscopy practice.
Definition of competence standards for optical diagnosis of diminutive colorectal polyps: European Society of Gastrointestinal Endoscopy (ESGE) Position Statement
Abstract Background The European Society of Gastrointestinal Endoscopy (ESGE) has developed a core curriculum for high quality optical diagnosis training for practice across Europe. The development of easy-to-measure competence standards for optical diagnosis can optimize clinical decision-making in endoscopy. This manuscript represents an official Position Statement of the ESGE aiming to define simple, safe, and easy-to-measure competence standards for endoscopists and artificial intelligence systems performing optical diagnosis of diminutive colorectal polyps (1 – 5 mm). Methods A panel of European experts in optical diagnosis participated in a modified Delphi process to reach consensus on Simple Optical Diagnosis Accuracy (SODA) competence standards for implementation of the optical diagnosis strategy for diminutive colorectal polyps. In order to assess the clinical benefits and harms of implementing optical diagnosis with different competence standards, a systematic literature search was performed. This was complemented with the results from a recently performed simulation study that provides guidance for setting alternative competence standards for optical diagnosis. Proposed competence standards were based on literature search and simulation study results. Competence standards were accepted if at least 80 % agreement was reached after a maximum of three voting rounds. Recommendation 1 In order to implement the leave-in-situ strategy for diminutive colorectal lesions (1–5 mm), it is clinically acceptable if, during real-time colonoscopy, at least 90 % sensitivity and 80 % specificity is achieved for high confidence endoscopic characterization of colorectal neoplasia of 1–5 mm in the rectosigmoid. Histopathology is used as the gold standard. Level of agreement 95 %. Recommendation 2 In order to implement the resect-and-discard strategy for diminutive colorectal lesions (1–5 mm), it is clinically acceptable if, during real-time colonoscopy, at least 80 % sensitivity and 80 % specificity is achieved for high confidence endoscopic characterization of colorectal neoplasia of 1–5 mm. Histopathology is used as the gold standard. Level of agreement 100 %. Conclusion The developed SODA competence standards define diagnostic performance thresholds in relation to clinical consequences, for training and for use when auditing the optical diagnosis of diminutive colorectal polyps.
Editorial: understanding IBS pathophysiology through “converging channels” of research—authors’ reply
LINKED CONTENTThis article is linked to Grover et al and Elwing & Sayuk papers. To view these articles, visit https://doi.org/10.1111/apt.16591 and https://doi.org/10.1111/apt.16603
Intestinal chemosensitivity in irritable bowel syndrome associates with small intestinal TRPV channel expression
SummaryBackgroundIrritable bowel syndrome (IBS) patients often experience meal‐associated symptoms. However, the underlying mechanisms are unclear.AimTo determine small intestinal mechanisms of lipid‐induced symptoms and rectal hypersensitivity in IBSMethodsWe recruited 26 IBS patients (12 IBS‐C, 14 IBS‐D) and 15 healthy volunteers (HV). In vivo permeability was assessed using saccharide excretion assay. Rectal sensitivity was assessed using a barostat before and after small bowel lipid infusion; symptoms were assessed throughout. Next, an extended upper endoscopy with probe‐based confocal laser endomicroscopy (pCLE) was performed with changes induced by lipids. Duodenal and jejunal mucosal biopsies were obtained for transcriptomics.ResultsFollowing lipid infusion, a higher proportion of HV than IBS patients reported no pain, no nausea, no fullness and no urgency (P < 0.05 for all). In a model adjusted for sex and anxiety, IBS‐C and IBS‐D patients had lower thresholds for first rectal sensation (P = 0.0007) and pain (P = 0.004) than HV. In vivo small intestinal permeability and mean pCLE scores were similar between IBS patients and HV. Post‐lipid, pCLE scores were higher than pre‐lipid but were not different between groups. Baseline duodenal transient receptor potential vanilloid (TRPV) 1 and 3 expression was increased in IBS‐D, and TRPV3 in IBS‐C. Duodenal TRPV1 expression correlated with abdominal pain (r = 0.51, FDR = 0.01), and inversely with first rectal sensation (r = −0.48, FDR = 0.01) and pain (r = −0.41, FDR = 0.02) thresholds.ConclusionLipid infusion elicits a greater symptom response in IBS patients than HV, which is associated with small intestinal expression of TRPV channels. TRPV‐mediated small intestinal chemosensitivity may mediate post‐meal symptoms in IBS.
WATER-ASSISTED COLONOSCOPY AND POLYPECTOMY: FIRST INTERNATIONAL DELPHI CONSENSUS STATEMENTS
Background Probe‐based confocal laser endomicroscopy (pCLE) provides microscopic imaging during an endoscopic procedure. Its introduction as a standard modality in gastroenterology has brought significant progress in management strategies, affecting many aspects of clinical care and requiring standardisation of practice and training. Objective This study aimed to provide guidance on the standardisation of its practice and training in Barrett's oesophagus, biliary strictures, colorectal lesions and inflammatory bowel diseases. Methods Initial statements were developed by five group leaders, based on the available clinical evidence. These statements were then voted and edited by the 26 participants, using a modified Delphi approach. After two rounds of votes, statements were validated if the threshold of agreement was higher than 75%. Results Twenty‐six experts participated and, among a total of 77 statements, 61 were adopted (79%) and 16 were rejected (21%). The adoption of each statement was justified by the grade of evidence. Conclusion pCLE should be used to enhance the diagnostic arsenal in the evaluation of these indications, by providing microscopic information which improves the diagnostic performance of the physician. In order actually to implement this technology in the clinical routine, and to ensure good practice, standardised initial and continuing institutional training programmes should be established.