Back to Authors

Ahmed, Ali M.

https://orcid.org/0000-0002-8940-6757

Mayo Clinic

University of Alabama at Birmingham

Citations 10

Feasibility and Utility of Routine Point‐of‐Care Gastric Ultrasonography in Patients Undergoing Upper Gastrointestinal Endoscopy Procedures: A Prospective Cohort Study
Kalagara, Hari , Sondekoppam, Rakesh V. , Ahmed, Ali M. , Venkata, Krishna, Pierce, Albert, Roth, Kaehler J., Mitchell, Rachel , Redden, David T. , Peter, Shajan , Kalagara, Hari , Sondekoppam, Rakesh V , Mitchell, Rachel, Baig, Kondal R. Kyanam Kabir

Journal of Ultrasound in Medicine | July 4, 2023 | Volume: 42 | Issue: 11 | Pages: 2643-2652

10.1002/jum.16299 Get It

ObjectivesPrevious studies have indicated that point‐of‐care ultrasonography (POCUS) of the gastric antrum can predict the adequacy of fasting before surgery and anesthesia. The aim of this study was to evaluate the utility of gastric POCUS in patients undergoing upper gastrointestinal (GI) endoscopy procedures.MethodsWe performed a single‐center cohort study in patients undergoing upper GI endoscopy. Consenting patient's gastric antrum was scanned before anesthetic care for endoscopy to determine the cross‐sectional area (CSA) and qualitatively determine safe and unsafe contents. Further, an estimate of residual gastric volume was determined using the formula and the nomogram methods. Subsequently, gastric secretions aspirated during endoscopy were quantified and further correlated with nomogram and formula‐based assessments. No patient required a change in the primary anesthetic plan except for using rapid sequence induction in those with unsafe contents on POCUS scans.ResultsQualitative ultrasound measurements consistently determined safe and unsafe gastric residual contents in 83 patients enrolled in the study. Unsafe contents were determined by qualitative scans in 4 out of 83 cases (5%) despite adequate fasting status. Quantitatively, only a moderate correlation was demonstrated between measured gastric volumes and nomogram (r = .40, 95% CI: 0.20, 0.57; P = .0002) or formula‐based (r = .38, 95% CI: 0.17, 0.55; P = .0004) determinations of residual gastric volumes.ConclusionIn daily clinical practice, qualitative POCUS determination of residual gastric content is a feasible and useful technique to identify patients at risk of aspiration before upper GI endoscopy procedures.
Extreme endoscopy: direct jejunostomy, re-anastomosis of bowel, percutaneous assisted transprosthetic endoscopic drainage in Roux-en-Y gastric bypass
García, A Martínez-Alcalá , Jovanović, Ivan , Ahmed, Ali M. , D’Assunção, Marco A. , Kröner, Paul T. , Mönkemüller, Klaus, Martínez-Alcalá García, Álvaro , Kröner, Paul T

Endoscopy | February 17, 2021 | Volume: 54 | Issue: 01 | Pages: E13-E14

10.1055/a-1346-7877 Get It

Abstract 17182: Coronary Endothelial Dysfunction in Humans is Associated With Elevated Expression of Clonal Hematopoiesis of Indeterminate Potential
Ganji, Morsaleh , Lerman, Lilach O. , Patnaik, Mrinal M. , Lasho, Terra L. , Toya, Takumi , Ahmed, Ali M. , Corban, Michel , Lerman, Amir

Circulation | November 12, 2020 | Volume: 142 | Issue: Suppl_3 | Pages: No page available

10.1161/circ.142.suppl_3.17182 Get It

Introduction: Recent evidence has demonstrated that Clonal Hematopoiesis of Indeterminate Potential (CHIP) increases the risk of cardiovascular events. However, the exact role played by CHIP in early stages of coronary atherosclerosis, characterized by coronary endothelial dysfunction remains to be elucidated. Hypothesis: The current study was designed to test the hypothesis that the presence of CHIP in peripheral blood cells is associated with coronary endothelial dysfunction and increased levels of inflammatory markers. Methods: Next generation sequencing was used to detect mutations among patients who had coronary endothelial dysfunction and control group (normal coronary endothelial function). Endothelial dysfunction was defined by ≥ 20% decrease in coronary artery diameter or ≤50% increase in blood flow in response to acetylcholine injection compared to baseline. Plasma cytokine levels of Interleukin (IL)-6 and IL-8 were also assessed. Results: Clonal hematopoiesis relevant gene mutations were found in 1 out of 64 patients with normal endothelial function (1.5%) and 11 out of 119 cases in the endothelial dysfunction group (9.2%) (P = 0.04) with ASXL1 (Additional sex combs-like 1) being the most frequent gene (4.2%) mutated. Cytokine analysis demonstrated that mutations in ASXL1, DNMT3A (DNA methyltransferase 3A) and TET2 (Ten-eleven-translocation-2) in the endothelial dysfunction group were associated with increased levels of IL-6 and IL-8 (P = 0.001, P = 0.003; respectively). Conclusions: The current study supports a potential role for CHIP in mechanisms of coronary artery disease starting at early stage of atherosclerosis. Furthermore, enhanced expression levels of IL-6 and IL-8 seem to be related to mutations in DNMT3A, ASXL1 and TET2 genes, more than other gene mutations relevant CHIP.
DOUBLE BALLOON ENTEROSCOPY ERCP RENDEZVOUS TECHNIQUE
García, A Martínez-Alcalá, Shoreibah, Mohamed , Kröner, PT, Mönkemüller, K, García, A Martínez-Alcalá, Ahmed, Ali M. , Mönkemüller, Klaus

Endoscopy | July 10, 2018 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.1055/s-0038-1637648 Get It

NEW METHOD TO INSERT LARGE CALIBER PLASTIC AND SELF-EXPANDING METAL STENTS (SEMS) DURING BALLOON OVERTUBE ENTEROSCOPY (BAE) ASSISTED ERCP
Kröner, PT, García, A Martínez-Alcalá, Schwingel, Giovani , D'Assunção, MA, Fry, LC , Mönkemüller, Klaus, García, A Martínez-Alcalá, Ahmed, Ali M.

Endoscopy | July 10, 2018 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.1055/s-0038-1637100 Get It

EXTREME ENDOSCOPY: A NEW PARADIGM IN THERAPEUTIC ENDOSCOPY
Kröner, PT, García, A Martínez-Alcalá, D'Assunção, MA, Jovanović, Ivan , Mönkemüller, Klaus, García, A Martínez-Alcalá, Ahmed, Ali M. , Baig, Kondal R. Kyanam Kabir

Endoscopy | July 10, 2018 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.1055/s-0038-1637311 Get It

EXTREME ENDOSCOPY: DIRECT JEJUNOSTOMY, ENDOSCOPIC RE-ANASTOMOSIS OF INTESTINES, PERCUTANEOUS ASSISTED TRANSPROSTHETIC THERAPY (PATENT) IN PATIENT ANASTOMOTIC DEHISCENCE AND COMPLEX PLEUROPERITONEAL ABSCESS AFTER PANCREATIC SURGERY
García, A Martínez-Alcalá, Kroner, TP, Jovanović, Ivan , Fry, LC , D'Assunção, MA, Mönkemüller, Klaus, García, A Martínez-Alcalá, Ahmed, Ali M.

Endoscopy | July 10, 2018 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.1055/s-0038-1637278 Get It

ADVANCED ENDOSCOPIC MANAGEMENT OF SEVERE, COMPLEX BARIATRIC SURGERY COMPLICATIONS
García, A Martínez-Alcalá, Kröner, PT, D'Assunção, MA, Jovanović, Ivan , Mönkemüller, Klaus, García, A Martínez-Alcalá, Ahmed, Ali M.

Endoscopy | July 10, 2018 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.1055/s-0038-1637192 Get It

BALLOON-OVERTUBE ENTEROSCOPY ASSISTED (BAE) VERSUS LAPAROSCOPY-ASSISTED ERCP IN BARIATRIC POST- ROUX-EN-Y GASTRIC BYPASS PATIENTS: A COMPARATIVE STUDY
García, A Martínez-Alcalá, Kumar, Ujjwal, Kröner, PT, Jovanović, Ivan , Schwingel, Giovani , Neumann, Helmut , Mönkemüller, Klaus, García, A Martínez-Alcalá, Ahmed, Ali M.

Endoscopy | July 10, 2018 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.1055/s-0038-1637099 Get It

UTILITY OF DOUBLE BALLOON ENTEROSCOPY IN PATIENTS WITH SURGICALLY ALTERED BOWEL ANATOMY AFTER OBESITY SURGERY
García, A Martínez-Alcalá, Kröner, PT, Peter, Shajan , Ahmed, Ali M. , Jovanović, Ivan , Mönkemüller, Klaus, García, A Martínez-Alcalá, Gutierrez, JP

Endoscopy | July 10, 2018 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.1055/s-0038-1637080 Get It