Back to Authors

Dinis‐Ribeiro, Mário

https://orcid.org/0000-0003-0121-6850

Mayo Clinic

IPO Porto

Citations 3

Can optical evaluation distinguish between T1a and T1b esophageal adenocarcinoma: an international expert interobserver agreement study
Gupta, Sunil , Mandarino, Francesco Vito , Hourigan, Luke F. , Messmann, Helmut , Wallace, Michael B. , Repici, Alessandro , Haber, Gregory , Taylor, Andrew C.F., Waxman, Irving , Siersema, Peter D. , Lemmers, Arnaud , Bisschops, Raf , Mosko, Jeffrey D. , Pech, Oliver , Beyna, Torsten , Sharma, Prateek , Lee, Eric Y.T., Bourke, Michael J., group, on behalf of the study working, Bourke, Michael J. , Shahidi, Neal , Wallace, Michael B , Bisschops, Raf , Beyna, Torsten , Burgess, Nicholas G , Mandarino, Francesco Vito , Gupta, Sunil , Dinis‐Ribeiro, Mário , Pouw, Roos E. , Teshima, Christopher , Ragunath, Krish , Rösch, Thomas , group, on behalf of the study working

Endoscopy | August 21, 2024 | Volume: 57 | Issue: 03 | Pages: 200-207

10.1055/a-2399-1401 Get It

Background Piecemeal endoscopic mucosal resection (EMR) is an acceptable technique for T1a esophageal adenocarcinoma, but en bloc R0 excision is advocated for T1b disease as it may offer a potential cure and mitigate recurrence. Thus, distinguishing between T1a and T1b disease is imperative under current treatment paradigms. We investigated whether expert Barrett’s endoscopists could make this distinction based on optical evaluation. Methods Endoscopic images of histologically confirmed high grade dysplasia (HGD), T1a, and T1b disease (20 sets for each) were compiled from consecutive patients at a single institution. Each set contained four images including an overview, a close-up in high definition white light, a near-focus magnification image, and a narrow-band image. Experts predicted the histology for each set. Results 19 experts from 8 countries (Australia, USA, Italy, Netherlands, Germany, Canada, Belgium, and Portugal) participated. The majority had been practicing for > 20 years, with a median (interquartile range) annual case volume of 50 (18–75) for Barrett’s EMR and 25 (10–45) for Barrett’s endoscopic submucosal dissection. Esophageal adenocarcinoma (T1a/b) could be distinguished from HGD with a pooled sensitivity of 89.1 % (95 %CI 84.7–93.4). T1b adenocarcinoma could be predicted with a pooled sensitivity of 43.8 % (95 %CI 29.9–57.7). Fleiss’ kappa was 0.421 (95 %CI 0.399–0.442; P < 0.001), indicating fair-to-moderate agreement. Conclusions Expert Barrett’s endoscopists could reliably differentiate T1a/T1b esophageal adenocarcinoma from HGD. Despite fair-to-moderate agreement for T staging, T1b disease could not be reliably distinguished from T1a disease. This may impact clinical decision making and selection of endoscopic techniques.
Definition of competence standards for optical diagnosis of diminutive colorectal polyps: European Society of Gastrointestinal Endoscopy (ESGE) Position Statement
Houwen, Britt B. S. L. , Hassan, Cesare , Greuter, Marjolein J.E. , Hazewinkel, Yark, Vleugels, Jasper L.A., Antonelli, Giulio , Bustamante, Marco , Coron, Emmanuel , Cortas, George, Dinis‐Ribeiro, Mário , Dobru, Daniela , Iacucci, Marietta , Jover, Rodrigo , Kuvaev, Roman , Neumann, Helmut , Rutter, Matthew D. , Saunders, Brian P. , Tate, David J. , Bisschops, Raf , Dekker, Evelien , Bustamante-Balén, Marco , Neumann, Helmut , Pellisé, Maria , Puig, Ignasi , Rutter, Matthew D , Mori, Yuichi , Bisschops, Raf , Dekker, Evelien , Hassan, Cesare , Iacucci, Marietta , Coupé, Veerle M.H. , East, James E. , Mori, Yuichi , Longcroft‐Wheaton, Gaius

Endoscopy | December 6, 2021 | Volume: 54 | Issue: 01 | Pages: 88-99

10.1055/a-1689-5130 Get It

Abstract Background The European Society of Gastrointestinal Endoscopy (ESGE) has developed a core curriculum for high quality optical diagnosis training for practice across Europe. The development of easy-to-measure competence standards for optical diagnosis can optimize clinical decision-making in endoscopy. This manuscript represents an official Position Statement of the ESGE aiming to define simple, safe, and easy-to-measure competence standards for endoscopists and artificial intelligence systems performing optical diagnosis of diminutive colorectal polyps (1 – 5 mm). Methods A panel of European experts in optical diagnosis participated in a modified Delphi process to reach consensus on Simple Optical Diagnosis Accuracy (SODA) competence standards for implementation of the optical diagnosis strategy for diminutive colorectal polyps. In order to assess the clinical benefits and harms of implementing optical diagnosis with different competence standards, a systematic literature search was performed. This was complemented with the results from a recently performed simulation study that provides guidance for setting alternative competence standards for optical diagnosis. Proposed competence standards were based on literature search and simulation study results. Competence standards were accepted if at least 80 % agreement was reached after a maximum of three voting rounds. Recommendation 1 In order to implement the leave-in-situ strategy for diminutive colorectal lesions (1–5 mm), it is clinically acceptable if, during real-time colonoscopy, at least 90 % sensitivity and 80 % specificity is achieved for high confidence endoscopic characterization of colorectal neoplasia of 1–5 mm in the rectosigmoid. Histopathology is used as the gold standard. Level of agreement 95 %. Recommendation 2 In order to implement the resect-and-discard strategy for diminutive colorectal lesions (1–5 mm), it is clinically acceptable if, during real-time colonoscopy, at least 80 % sensitivity and 80 % specificity is achieved for high confidence endoscopic characterization of colorectal neoplasia of 1–5 mm. Histopathology is used as the gold standard. Level of agreement 100 %. Conclusion The developed SODA competence standards define diagnostic performance thresholds in relation to clinical consequences, for training and for use when auditing the optical diagnosis of diminutive colorectal polyps.