Back to Authors

Teshima, Christopher

0000-0002-5525-8565

Mayo Clinic

St. Michael's Hospital

Citations 5

International Validation of a Novel PEACE Scale to Improve the Quality of Upper Gastrointestinal Mucosal Inspection During Endoscopy
Romańczyk, Marcin , Desai, Madhav , Abe, Seiichiro , Alkandari, Asma , Beyna, Torsten , Bisschops, Raf , Budzyń, Krzysztof , Grover, Samir C. , Gyawali, C. Prakash, Inoue, Haruhiro , Iyer, Prasad G. , Srinivasan, Sachin , Gyawali, C. Prakash , Hassan, Cesare , Gyawali, C P , Hassan, Cesare , Bisschops, Raf , Grover, Samir C , Kaminski, Michal Filip , Bugdol, Monika Natalia , Messmann, Helmut , Ragunath, Krish , Saito, Yutaka , Teshima, Christopher , Yadlapati, Rena , Sharma, Prateek

Clinical and Translational Gastroenterology | November 14, 2024 | Volume: 16 | Issue: 1 | Pages: e00786

10.14309/ctg.0000000000000786 Get It

INTRODUCTION: The performance of a high quality esophagogastroduodenoscopy (EGD) is dependent on the mucosal cleanliness. Recently, the Polprep: Effective Assessment of Cleanliness in EGD (PEACE) scale was created to assess the degree of mucosal cleanliness during EGD. The aim of this study was to validate this scoring system in a cohort of international endoscopists. METHODS: In total, 39 EGD videos, with different degrees of mucosal cleanliness were retrieved from a previously conducted prospective trial. All experts rated the cleanliness of the mucosa on each video using the PEACE scale. To evaluate agreement of all scores (0–3), intraclass correlation coefficient 2.1 was used. The agreement on adequate (scores 2 and 3) and inadequate (scores 0 and 1) cleanliness was assessed using kappa values. RESULTS: Videos evaluating esophagus, stomach, and duodenum cleanliness were reviewed by 16 endoscopists. The PEACE scores demonstrated good agreement (intraclass correlation coefficient 0.82, 95% CI 0.75–0.89), especially for esophagus (0.84; 95% CI 0.71–0.95) and stomach (0.81; 95% CI 0.69–0.91), while agreement was moderate for the duodenum (0.69; 95% CI 0.51–0.87). The agreement was similar between Eastern (0.86; 95% CI 0.79–0.92) and Western experts (0.80; 95% CI 0.72–0.88). Similarly, agreement regarding adequate cleanliness was comparable between Eastern (0.70; 95% CI 0.55–0.85) and Western (0.74; 95% CI 0.64–0.84) endoscopists being overall 0.75 (95% CI 0.65–0.85). DISCUSSION: The PEACE scoring system is a simple and reliable scale to assess the cleanliness during EGD. The score is now validated among international experts with high concordance, justifying its use in clinical practice.
Defining standards for fluoroscopy in gastrointestinal endoscopy using Delphi methodology
Khalaf, Kareem , Pawlak, Katarzyna M. , Alkandari, Asma , Baron, Todd H. , Bechara, Robert , Binda, Cecilia , Chen, Yen‐I , Moura, Eduardo Guimarães Hourneaux de , Forbes, Nauzer , James, Paul, Martin, Harry , May, Gary R. , Mosko, Jeffrey D. , Oyeleke, Ganiyat K. , Petersen, Bret T. , Saxena, Payal , Sethi, Amrita , Sharaiha, Reem Z. , Tang, Raymond S. , Villarroel, Mariano , Hooft, Jeanin E. van , Renteln, Daniel von , Walsh, Catharine M. , Aberin, Tricia, Banavage, Dawn, Chen, Jowell Akina, Clancy, James, Drake, Heather, Im, Melanie, Low, Chooi Peng, Myszko, Alexandra, Navarro, Krista, Redman, Jessica, Reyes, Wayne, Weinstein, Faina, Na, Caleb, Tham, Daniel , He, Tony , Malipatil, Sharan B., Gimpaya, Nikko , Kundra, Arjun , Grover, Samir C. , Barkun, Alan N , Bechara, Robert , Binda, Cecilia , de Moura, Eduardo , Hassan, Cesare , Kahaleh, Michel , Sharaiha, Reem Z , Villarroel, Mariano , van Hooft, Jeanin E , Voermans, Rogier P , von Renteln, Daniel , Walsh, Catharine M , Gupta, Sunil , Fujiyoshi, Yusuke , Grover, Samir C , Causada Calo, Natalia S , Pawlak, Katarzyna M , Adler, Douglas G. , Barkun, Alan , Berzin, Tyler M. , Cai, Ming‐Yan , Carrara, Silvia , Fugazza, Alessandro , Hassan, Cesare , James, Paul D., Kahaleh, Michel , Maselli, Roberta , Repici, Alessandro , Spadaccini, Marco , Teshima, Christopher , Voermans, Rogier P. , Clancy, James, Reyes, Wayne, Gupta, Sunil , Mokhtar, Ahmed H., Gholami, Reza

Endoscopy International Open | October 7, 2024 | Volume: 12 | Issue: 11 | Pages: E1315-E1325

10.1055/a-2427-3893 Get It

Abstract Background and study aims Use of fluoroscopy in gastrointestinal endoscopy is an essential aid in advanced endoscopic interventions. However, it also raises concerns about radiation exposure. This study aimed to develop consensus-based statements for safe and effective use of fluoroscopy in gastrointestinal endoscopy, prioritizing the safety and well-being of healthcare workers and patients. Methods A modified Delphi approach was employed to achieve consensus over three rounds of surveys. Proposed statements were generated in Round 1. In the second round, panelists rated potential statements on a 5-point scale, with consensus defined as ≥80% agreement. Statements were subsequently prioritized in Round 3, using a 1 (lowest priority) to 10 (highest priority) scale. Results Forty-six experts participated, consisting of 34 therapeutic endoscopists and 12 endoscopy nurses from six continents, with an overall 45.6% female representation (n = 21). Forty-three item statements were generated in the first round. Of these, 31 statements achieved consensus after the second round. These statements were categorized into General Considerations (n = 6), Education (n = 10), Pregnancy (n = 4), Family Planning (n = 2), Patient Safety (n = 4), and Staff Safety (n = 5). In the third round, accepted statements received mean priority scores ranging from 7.28 to 9.36, with 87.2% of statements rated as very high priority (mean score ≥ 9). Conclusions This study presents consensus-based statements for safe and effective use of fluoroscopy in gastrointestinal endoscopy, addressing the well-being of healthcare workers and patients. These consensus-based statements aim to mitigate risks associated with radiation exposure while maintaining benefits of fluoroscopy, ultimately promoting a culture of safety in healthcare settings.
Can optical evaluation distinguish between T1a and T1b esophageal adenocarcinoma: an international expert interobserver agreement study
Gupta, Sunil , Mandarino, Francesco Vito , Hourigan, Luke F. , Messmann, Helmut , Wallace, Michael B. , Repici, Alessandro , Haber, Gregory , Taylor, Andrew C.F., Waxman, Irving , Siersema, Peter D. , Lemmers, Arnaud , Bisschops, Raf , Mosko, Jeffrey D. , Pech, Oliver , Beyna, Torsten , Sharma, Prateek , Lee, Eric Y.T., Bourke, Michael J., group, on behalf of the study working, Bourke, Michael J. , Shahidi, Neal , Wallace, Michael B , Bisschops, Raf , Beyna, Torsten , Burgess, Nicholas G , Mandarino, Francesco Vito , Gupta, Sunil , Dinis‐Ribeiro, Mário , Pouw, Roos E. , Teshima, Christopher , Ragunath, Krish , Rösch, Thomas , group, on behalf of the study working

Endoscopy | August 21, 2024 | Volume: 57 | Issue: 03 | Pages: 200-207

10.1055/a-2399-1401 Get It

Background Piecemeal endoscopic mucosal resection (EMR) is an acceptable technique for T1a esophageal adenocarcinoma, but en bloc R0 excision is advocated for T1b disease as it may offer a potential cure and mitigate recurrence. Thus, distinguishing between T1a and T1b disease is imperative under current treatment paradigms. We investigated whether expert Barrett’s endoscopists could make this distinction based on optical evaluation. Methods Endoscopic images of histologically confirmed high grade dysplasia (HGD), T1a, and T1b disease (20 sets for each) were compiled from consecutive patients at a single institution. Each set contained four images including an overview, a close-up in high definition white light, a near-focus magnification image, and a narrow-band image. Experts predicted the histology for each set. Results 19 experts from 8 countries (Australia, USA, Italy, Netherlands, Germany, Canada, Belgium, and Portugal) participated. The majority had been practicing for > 20 years, with a median (interquartile range) annual case volume of 50 (18–75) for Barrett’s EMR and 25 (10–45) for Barrett’s endoscopic submucosal dissection. Esophageal adenocarcinoma (T1a/b) could be distinguished from HGD with a pooled sensitivity of 89.1 % (95 %CI 84.7–93.4). T1b adenocarcinoma could be predicted with a pooled sensitivity of 43.8 % (95 %CI 29.9–57.7). Fleiss’ kappa was 0.421 (95 %CI 0.399–0.442; P < 0.001), indicating fair-to-moderate agreement. Conclusions Expert Barrett’s endoscopists could reliably differentiate T1a/T1b esophageal adenocarcinoma from HGD. Despite fair-to-moderate agreement for T staging, T1b disease could not be reliably distinguished from T1a disease. This may impact clinical decision making and selection of endoscopic techniques.
International validation of a PEACE scale assessing cleanliness during esophagogastroduodenoscopy to improve the quality of inspection during endoscopy
Romańczyk, Monika , Desai, Madhav , Abe, Seiichiro , Alkandari, Asma , Beyna, Torsten , Budzyń, Krzysztof , Grover, Samir C. , Gyawali, P. , Iyer, Prasad G. , Srinivasan, Sachin , Grover, Samir C , Kaminski, Michal Filip , Bisschops, Raf , Bugdol, Marcin Dominik , Gyawali, P., Inoue, H., Messmann, Helmut , Ragunath, Krish , Saito, Yutaka , Teshima, Christopher , Yadlapati, Rena , Hassan, Cesare , Sharma, Prateek

Endoscopy | April 23, 2024 | Volume: 56 | Issue: S 02 | Pages: S27-S28

10.1055/s-0044-1782743 Get It