Back to Authors

Petersen, Bret T.

https://orcid.org/0000-0003-1361-4127

Mayo Clinic

Mayo Clinic

Citations 23

Post-ERCP pancreatitis after self-expanding metal stent placement in patients with pancreatic versus non-pancreatic malignant biliary obstruction
AbiMansour, Jad P. , Petersen, Bret T. , Valls, Eric J. Vargas, Law, Ryan, Han, Samuel, AbiMansour, Jad , Vargas Valls, Eric J, Petersen, Bret T. , Vargas, Eric J. , Law, Ryan, Chandrasekhara, Vinay

Therapeutic Advances in Gastrointestinal Endoscopy | June 23, 2026 | Volume: 19 | Issue: No issue available | Pages: No page available

10.1177/26317745261458987 Get It

Background: Self-expanding metal stents (SEMS) are recommended for the endoscopic palliation of distal malignant biliary obstruction (DMBO). Placement of SEMS during endoscopic retrograde cholangiopancreatography (ERCP) has been associated with an increased risk of post-ERCP pancreatitis (PEP). Objectives: The aim of this study is to evaluate rates of PEP in patients who underwent SEMS placement for pancreatic versus non-pancreatic malignancy. Design: Retrospective Cohort Study. Methods: Patients who underwent SEMS placement for DMBO between June 2017 and May 2021 were identified retrospectively from a procedural billing database. PEP incidence was compared between pancreatic and non-pancreatic DMBO groups and multivariate logistic regression was performed to identify risk factors for PEP. Results: A total of 488 individuals were identified, with 395 (80.9%) cases of DMBO due to pancreatic and 93 (19.1%) due to non-pancreatic malignancy. Stent types included 124 (25.4%) fully covered (FCSEMS) and 364 (74.6%) uncovered metal stents (UCSEMS). The overall rate of PEP in the cohort was 6.3% with no significant difference between pancreatic and non-pancreatic etiologies (6.1% vs 7.5%, p = 0.606). When adjusted for age <50 years old, female sex, and pancreatic stent placement, a non-pancreatic malignancy was not associated with an increased risk of PEP (OR 0.83, 95% CI 0.36–2.15). Conclusion: No statistically significant difference in PEP rates was seen after biliary sphincterotomy and SEMS placement for palliation of DMBO in patients with pancreatic versus non-pancreatic malignancies.
The incidence and predictors of false-negative pancreatobiliary fluorescence in situ hybridization (PB-FISH) in biliary strictures: A prospective study
Aggarwal, Manik , Gores, Gregory J. , Law, Ryan , Martin, John A. , Petersen, Bret T. , Eaton, John E. , Roberts, Lewis R. , Gores, Gregory J. , Vargas, Eric J , Storm, Andrew C , Law, Ryan J, Roberts, Lewis R , Chandrasekhara, Vinay , Aggarwal, Manik , Vargas, Eric J. , Storm, Andrew C. , Dayyeh, Barham K. Abu , Petersen, Bret T. , Ilyas, Sumera I. , Chandrasekhara, Vinay

Hepatology Communications | July 21, 2025 | Volume: 9 | Issue: 8 | Pages: No page available

10.1097/hc9.0000000000000751 Get It

Background: Fluorescence in situ hybridization (FISH) is recommended as part of multimodality sampling in the evaluation of biliary strictures, but can be false negative in 40%–50% cases. The aim of this study was to comprehensively assess predictors of false-negative FISH in patients with biliary strictures. Methods: Patients undergoing tissue sampling for biliary strictures from October 20 to February 22 were prospectively enrolled (NCT04572711). Procedural factors such as sampling techniques, order, and utilization of combination sampling were recorded. Results of an optimized pancreatobiliary FISH panel with locus-specific probes for 1q21, 7p12, 8q24, and 9p21 were reported per guidelines. Statistical analyses were performed using BlueSky Statistics v.10.3.1, R package v8.81. Results: Of 327 patients, 93 (28.5%) were diagnosed with malignancy. A false-negative pancreatobiliary fluorescence in situ hybridization (PB-FISH) was reported in 40 (43.1%) patients. A history of primary sclerosing cholangitis was associated with lower odds of having a false-negative PB-FISH (aOR=0.38, 95% CI=0.16–0.82, p=0.02), whereas a hilar stricture was associated with a significantly higher false-negative PB-FISH in those with cholangiocarcinoma (aOR=3.2 [1.4–7.9], p=0.009). Dilation of biliary strictures prior to brushing was not associated with a lower rate of false-negative PB-FISH. Conclusions: In this prospective study, hilar strictures were more likely to have false-negative PB-FISH. Dilation of strictures did not affect PB-FISH performance. These results can help guide PB-FISH interpretation.
Multicenter validation of a cholangioscopy artificial intelligence system for the evaluation of biliary tract disease
Marya, Neil B. , Powers, Patrick, Marcello, Matthew, Nasser‐Ghodsi, Navine , Rau, Prashanth , Mehta, Savant, Marshall, Christopher J., Leonor, Paul , Che, Kendrick , Petersen, Bret T. , Law, Ryan , Martin, John A. , AbiMansour, Jad P. , Abu Dayyeh, Barham, Storm, Andrew C , Vargas, Eric J , Marya, Neil B. , Thiruvengadam, Nikhil Ravi , Zivny, Jaroslav, Marshall, Christopher, Dayyeh, Barham K. Abu , Storm, Andrew C. , Petersen, Bret T. , Vargas, Eric J. , Chandrasekhara, Vinay

Endoscopy | July 6, 2025 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.1055/a-2650-0789 Get It

Abstract Clinicians struggle to accurately classify biliary strictures as benign or malignant. Current endoscopic retrograde cholangiopancreatography (ERCP)-based sampling modalities including brush cytology and forceps biopsy have poor sensitivity for pathologic confirmation of malignancy. Cholangioscopy allows for direct visualization and sampling of biliary pathology; however, this technology is also associated with inaccurate classification of biliary disease. Previously, an artificial intelligence (AI) system that analyzes cholangioscopy footage was found to be more accurate in diagnosing biliary malignancy than ERCP sampling techniques. The aim of this study was to validate this AI system on a new series of examinations. Three academic centers collected all available unedited cholangioscopy recordings. The videos were processed by the cholangioscopy AI system. After analyzing videos, the AI system provided predictions as to whether malignancy was present. AI performance in classifying strictures was compared with the performance of brush cytology and forceps biopsy. 112 cholangioscopy examinations (containing 4 817 081 images) were generated from 99 patients. Of those examinations, 61 (54.5%) were for investigation of biliary strictures (31 [50.8%] benign, 30 [49.2%] malignant). For the correct classification of strictures, the AI system was 80.0% sensitive and 90.3% specific. It was also significantly more accurate for stricture classification (85.2%) than brush cytology (52.5%; P<0.001), forceps biopsy (68.2%; P=0.04), and the combination of brush cytology and forceps biopsy (66.7%; P=0.02). A previously developed cholangioscopy AI system was found to continually outperform standard ERCP sampling modalities for accurate identification of malignancy, without additional retraining, in a multicenter validation cohort.
S136 Obesity Is Associated With Worsened Endoscopic Outcomes in Patients With Pancreatic Collections and Should Be Integrated Into the QNI Classification
Baroud, Serge , Annan, Karim Al , Mrad, Rudy , Han, Sam , Law, Ryan , Bofill-García, Aliana, Martin, John A. , Petersen, Bret T. , Vege, Santhi Swaroop , Kerbage, Anthony , AbiMansour, Jad P. , Vargas, Eric J. , Storm, Andrew C. , Chandrasekhara, Vinay , Petersen, Bret T. , Bazerbachi, Fateh , Majumder, Shounak , Dayyeh, Barham K. Abu

American Journal of Gastroenterology | October 24, 2024 | Volume: 119 | Issue: 10S | Pages: S102-S103

10.14309/01.ajg.0001028912.11285.a9 Get It

Utilization of an artificial intelligence–enhanced, web‐based application to review bile duct brushing cytologic specimens: A pilot study
Marya, Neil B. , Powers, Patrick, Bois, Melanie C. , Hartley, Christopher , Kerr, Sarah E. , Thangaiah, Judith Jebastin, Cantley, Richard , Gleeson, Ferga C. , Law, Ryan , Martin, John A. , Petersen, Bret T. , Levy, Michael J. , Jebastin, Judith A S , Cantley, Richard , Law, Ryan J, Maleki, Zahra , Pantanowitz, Liron , Petersen, Bret, Marya, Neil B. , Hartley, Christopher P , Norton, Daniel, Dayyeh, Barham K. Abu , Chandrasekhara, Vinay , Gores, Gregory J. , Maleki, Zahra , Petersen, Bret T. , Storm, Andrew C. , Graham, Rondell P.

Cancer Cytopathology | August 29, 2024 | Volume: 132 | Issue: 12 | Pages: 779-787

10.1002/cncy.22898 Get It

Abstract Background The authors previously developed an artificial intelligence (AI) to assist cytologists in the evaluation of digital whole‐slide images (WSIs) generated from bile duct brushing specimens. The aim of this trial was to assess the efficiency and accuracy of cytologists using a novel application with this AI tool. Methods Consecutive bile duct brushing WSIs from indeterminate strictures were obtained. A multidisciplinary panel reviewed all relevant information and provided a central interpretation for each WSI as being “positive,” “negative,” or “indeterminate.” The WSIs were then uploaded to the AI application. The AI scored each WSI as positive or negative for malignancy (i.e., computer‐aided diagnosis [CADx]). For each WSI, the AI prioritized cytologic tiles by the likelihood that malignant material was present in the tile. Via the AI, blinded cytologists reviewed all WSIs and provided interpretations (i.e., computer‐aided detection [CADe]). The diagnostic accuracies of the WSI evaluation via CADx, CADe, and the original clinical cytologic interpretation (official cytologic interpretation [OCI]) were compared. Results Of the 84 WSIs, 15 were positive, 42 were negative, and 27 were indeterminate after central review. The WSIs generated on average 141,950 tiles each. Cytologists using the AI evaluated 10.5 tiles per WSI before making an interpretation. Additionally, cytologists required an average of 84.1 s of total WSI evaluation. WSI interpretation accuracies for CADx (0.754; 95% CI, 0.622–0.859), CADe (0.807; 95% CI, 0.750–0.856), and OCI (0.807; 95% CI, 0.671–0.900) were similar. Conclusions This trial demonstrates that an AI application allows cytologists to perform a triaged review of WSIs while maintaining accuracy.
Meta-analysis of diagnostic performance of fluorescence in situ hybridization (FISH) for biliary strictures
Aggarwal, Manik , Simadibrata, Daniel M., Petersen, Bret T. , Martin, John A. , Barr-Fritcher, E., Schneider, A., Kipp, Benjamin R. , Chandrasekhara, V., Petersen, Bret T. , Schneider, A., Roberts, Lewis R. , Gores, Gregory J.

Endoscopy | April 23, 2024 | Volume: 56 | Issue: S 02 | Pages: S138-S138

10.1055/s-0044-1782991 Get It

Incidence of Post-ERCP Pancreatitis in Patients Receiving Diclofenac Versus Indomethacin Prophylaxis
Yamparala, A., Sathi, Thanmay, Harmsen, William S. , Lemke, Emily, Dayyeh, Barham Abu, Bofill-García, Aliana, Martin, John A. , Petersen, Bret T. , Topazian, Mark , Chandrasekhara, V., Law, Ryan , Janssens, Laurens , Lemke, E., Lévy, Michaël , Petersen, Bret T. , Storm, Andrew C. , Valls, E. Vargas

Endoscopy | November 9, 2023 | Volume: 55 | Issue: S 02 | Pages: S156-S156

10.1055/s-0043-1765392 Get It

Risk of post-sphincterotomy bleeding in patients with thrombocytopenia
AbiMansour, Jad P. , Garimella, Vishal, Petersen, Bret T. , Law, Ryan , Martin, John A. , Levy, Michael J. , Law, Ryan J, AbiMansour, Jad , Petersen, Bret T. , Storm, Andrew C. , Dayyeh, Barham K. Abu , Chandrasekhara, Vinay

Therapeutic Advances in Gastrointestinal Endoscopy | September 25, 2023 | Volume: 16 | Issue: No issue available | Pages: No page available

10.1177/26317745231200971 Get It

Background: Reports suggest that the rate of adverse events (AEs) post-endoscopic sphincterotomy (ES) to be as high as 10%, with gastrointestinal bleeding being most common after post-endoscopic retrograde cholangiopancreatography (ERCP) pancreatitis. Objective: The aim of this study was to characterize the incidence of bleeding in patients with thrombocytopenia following ES. Design: Retrospective observational cohort study. Methods: Patients with thrombocytopenia (defined as <150,000 platelets/μL) who underwent ES between May 2017 and December 2020 were identified at a tertiary care medical center. The incidence of immediate (intraprocedural oozing >5 min or requiring intervention) or delayed (clinical bleeding with associated hemoglobin drop within 14 days) post-ES bleeding was determined via manual chart review. Results: A total of 221 patients with a mean platelet count of 108,000 ± 13,000 platelets/μL underwent ERCP with ES. Immediate bleeding occurred in 11 (5%) patients with no significant drop in hemoglobin or transfusion requirement. Two patients (0.9%), both of whom were noted to have immediate bleeding, also developed delayed bleeding. Presence of malignancy was associated with an increased risk of bleeding (36.4% versus 11.4%, p = 0.037) while platelet count was not. Conclusion: In a cohort of patients with thrombocytopenia, rates of immediate and delayed bleeding are similar to previously reported AE rates of ES in the general patient population. Careful attention should be given to patients with a history of active malignancy as well as those who develop immediate bleeding as they appear to be at increased risk for bleeding complications.
Global prospective case series of ERCPs using a single-use duodenoscope
Bruno, Marco J. , Beyna, Torsten , Carr‐Locke, David L. , Chahal, Prabhleen , Costamagna, Guido , Devereaux, Benedict , Giovannini, Marc, Khor, Christopher , Lau, James Y., May, Gary R. , Muthusamy, V. Raman , Petersen, Bret T. , Raijman, Isaac , Reddy, D. Nageshwar , Ross, Andrew S., Sejpal, Divyesh V., Sherman, Stuart , Siddiqui, Uzma D. , Ziady, Christopher, Peetermans, Joyce , Rousseau, Matthew , Slivka, Adam, Group, EXALT Single-use Duodenoscope Study, Fichera, Alessandro , Pleskow, Douglas , Goenka, Mahesh Kumar , Patel, Sandeep , Petersen, Bret T. , Pleskow, Douglas K. , Repici, Alessandro , Group, EXALT Single-use Duodenoscope Study

Endoscopy | July 18, 2023 | Volume: 55 | Issue: 12 | Pages: 1103-1114

10.1055/a-2131-7180 Get It

Background The first commercialized single-use duodenoscope was cleared by the US Food and Drug Administration in December 2019. Data regarding endoscopic retrograde cholangiopancreatography (ERCP) using a single-use duodenoscope are needed on a broader range of cases conducted by endoscopists with varying levels of experience in a wide range of geographic areas. Methods 61 endoscopists at 22 academic centers in 11 countries performed ERCP procedures in adult patients aged ≥ 18. Outcomes included ERCP completion for the intended indication, rate of crossover to a reusable endoscope, device performance ratings, and serious adverse events (SAEs). Results Among 551 patients, 236 (42.8 %) were aged > 65, 281 (51.0 %) were men, and 256 (46.5 %) had their procedure as an inpatient. ERCPs included 196 (35.6 %) with American Society for Gastrointestinal Endoscopy complexity of grades 3–4. A total of 529 ERCPs (96.0 %) were completed: 503 (91.3 %) using only the single-use duodenoscope, and 26 (4.7 %) with crossover to a reusable endoscope. There were 22 ERCPs (4.0 %) that were not completed, of which 11 (2.0 %) included a crossover and 11 (2.0 %) were aborted cases (no crossover). Median ERCP completion time was 24.0 minutes. Median overall satisfaction with the single-use duodenoscope was 8.0 (scale of 1 to 10 [best]). SAEs were reported in 43 patients (7.8 %), including 17 (3.1 %) who developed post-ERCP pancreatitis. Conclusions In academic medical centers over a wide geographic distribution, endoscopists with varying levels of experience using the first marketed single-use duodenoscope had good ERCP procedural success and reported high performance ratings for this device.