Abstract Background The authors previously developed an artificial intelligence (AI) to assist cytologists in the evaluation of digital whole‐slide images (WSIs) generated from bile duct brushing specimens. The aim of this trial was to assess the efficiency and accuracy of cytologists using a novel application with this AI tool. Methods Consecutive bile duct brushing WSIs from indeterminate strictures were obtained. A multidisciplinary panel reviewed all relevant information and provided a central interpretation for each WSI as being “positive,” “negative,” or “indeterminate.” The WSIs were then uploaded to the AI application. The AI scored each WSI as positive or negative for malignancy (i.e., computer‐aided diagnosis [CADx]). For each WSI, the AI prioritized cytologic tiles by the likelihood that malignant material was present in the tile. Via the AI, blinded cytologists reviewed all WSIs and provided interpretations (i.e., computer‐aided detection [CADe]). The diagnostic accuracies of the WSI evaluation via CADx, CADe, and the original clinical cytologic interpretation (official cytologic interpretation [OCI]) were compared. Results Of the 84 WSIs, 15 were positive, 42 were negative, and 27 were indeterminate after central review. The WSIs generated on average 141,950 tiles each. Cytologists using the AI evaluated 10.5 tiles per WSI before making an interpretation. Additionally, cytologists required an average of 84.1 s of total WSI evaluation. WSI interpretation accuracies for CADx (0.754; 95% CI, 0.622–0.859), CADe (0.807; 95% CI, 0.750–0.856), and OCI (0.807; 95% CI, 0.671–0.900) were similar. Conclusions This trial demonstrates that an AI application allows cytologists to perform a triaged review of WSIs while maintaining accuracy.
Celiac artery mesenteric fat measurement with endosonography (CAMEUS) reliably correlates with obesity and related comorbidities
Abstract Background Visceral fat represents a metabolically active entity linked to adverse metabolic sequelae of obesity. We aimed to determine if celiac artery mesenteric fat thickness can be reliably measured during endoscopic ultrasound (EUS), and if these measurements correlate with metabolic disease burden. Methods This was a retrospective analysis of patients who underwent celiac artery mesenteric fat measurement with endosonography (CAMEUS) measurement at a tertiary referral center, and a validation prospective trial of patients with obesity and nonalcoholic steatohepatitis who received paired EUS exams with CAMEUS measurement before and after six months of treatment with an intragastric balloon. Results CAMEUS was measured in 154 patients [56.5% females, mean age 56.5 ± 18.0 years, body mass index (BMI) 29.8 ± 8.0 kg/m2] and was estimated at 14.7 ± 6.5 mm. CAMEUS better correlated with the presence of non-alcoholic fatty liver disease (NAFLD) (R2 = 0.248, P < 0.001) than BMI (R2 = 0.153, P < 0.001), and significantly correlated with metabolic parameters and diseases. After six months of intragastric balloon placement, the prospective cohort experienced 11.7% total body weight loss, 1.3 points improvement in hemoglobin A1c (P = 0.001), and a 29.4% average decrease in CAMEUS (−6.4 ± 5.2 mm, P < 0.001). CAMEUS correlated with improvements in weight (R2 = 0.368), aspartate aminotransferase to platelet ratio index (R2 = 0.138), and NAFLD activity score (R2 = 0.156) (all P < 0.05). Conclusions CAMEUS is a novel measure that is significantly correlated with critical metabolic indices and can be easily captured during routine EUS to risk-stratify susceptible patients. This station could allow for EUS access to sampling and therapeutics of this metabolic region.
Impact of the COVID – 19 Pandemic on Endoscopic Ultrasound and Radiology Liver Cytopathology Caseload and Diagnostic Accuracy
Endoscopic Ultrasound Primary Pancreas Neuroendocrine Tumor Size and Proliferation Index are Clinically Helpful but are they Enough? A Single Center 20-year Experience
Abstract Background and study aims The risk of bleeding with endoscopic ultrasound-guided tissue acquisition (EUS-TA) in patients on uninterrupted antithrombotic agents is unknown. This study aimed to assess the safety of EUS-TA without discontinuing direct oral anticoagulants. Methods Twenty pigs were randomized (1:1) to oral apixaban or placebo. Treatment was administered for 3 days before and 3 days after EUS-TA of the pancreas. Primary endpoint was occurrence of clinically significant bleeding events (CSBEs), defined as a composite outcome of drop in hemoglobin ≥ 2 g/dL and evidence of intraprocedural or post-procedure bleeding. Secondary outcome was cytopathological adequacy of acquired specimens. Endoscopists and pathologists were blinded to the treatment arm. Results Total of 80 tissue samples were obtained. CSBE occurred in one animal with apixaban levels above the upper limit (P = 1). Intraprocedural bleeding occurred in five animals (25 %), four of which from the apixaban group. Hematoma at necropsy was found in 10 animals (50 %), six of which were on apixaban. Median drop in hemoglobin was similar in both groups. Adequacy of specimens for cytology and pathology evaluation was confirmed in 20 of 20 and 19 of 20 animals, respectively. Conclusions In this pilot preclinical trial, EUS-TA under apixaban showed a trend toward higher minor bleeding events but did not increase CSBE or prevent adequate cytopathological evaluation.
SAFETY OF ENDOSCOPIC ULTRASOUND-GUIDED TISSUE ACQUISITION ON DIRECT ORAL ANTICOAGULANTS: A RANDOMIZED PRECLINICAL TRIAL
Composition, diversity and potential utility of intervention-naïve pancreatic cancer intratumoral microbiome signature profiling via endoscopic ultrasound