S136 Obesity Is Associated With Worsened Endoscopic Outcomes in Patients With Pancreatic Collections and Should Be Integrated Into the QNI Classification
S1596 Comparison of Nutritional Parameters, Efficacy, and Safety of Endoscopic Gastrojejunostomy versus Duodenal Self-Expandable Metal Stent for the Management of Malignant Gastric Outlet Obstruction
Abstract Background Visceral fat represents a metabolically active entity linked to adverse metabolic sequelae of obesity. We aimed to determine if celiac artery mesenteric fat thickness can be reliably measured during endoscopic ultrasound (EUS), and if these measurements correlate with metabolic disease burden. Methods This was a retrospective analysis of patients who underwent celiac artery mesenteric fat measurement with endosonography (CAMEUS) measurement at a tertiary referral center, and a validation prospective trial of patients with obesity and nonalcoholic steatohepatitis who received paired EUS exams with CAMEUS measurement before and after six months of treatment with an intragastric balloon. Results CAMEUS was measured in 154 patients [56.5% females, mean age 56.5 ± 18.0 years, body mass index (BMI) 29.8 ± 8.0 kg/m2] and was estimated at 14.7 ± 6.5 mm. CAMEUS better correlated with the presence of non-alcoholic fatty liver disease (NAFLD) (R2 = 0.248, P < 0.001) than BMI (R2 = 0.153, P < 0.001), and significantly correlated with metabolic parameters and diseases. After six months of intragastric balloon placement, the prospective cohort experienced 11.7% total body weight loss, 1.3 points improvement in hemoglobin A1c (P = 0.001), and a 29.4% average decrease in CAMEUS (−6.4 ± 5.2 mm, P < 0.001). CAMEUS correlated with improvements in weight (R2 = 0.368), aspartate aminotransferase to platelet ratio index (R2 = 0.138), and NAFLD activity score (R2 = 0.156) (all P < 0.05). Conclusions CAMEUS is a novel measure that is significantly correlated with critical metabolic indices and can be easily captured during routine EUS to risk-stratify susceptible patients. This station could allow for EUS access to sampling and therapeutics of this metabolic region.
Incidence of Post-ERCP Pancreatitis in Patients Receiving Diclofenac Versus Indomethacin Prophylaxis
Endoscopic Ultrasound Primary Pancreas Neuroendocrine Tumor Size and Proliferation Index are Clinically Helpful but are they Enough? A Single Center 20-year Experience
Abstract Background and study aims A percutaneous intragastric trocar (PIT) enables intraluminal use of laparoscopic tools and helps overcome traditional limitations of endoscopy. The aim of this study was to determine the efficacy of using a PIT to perform an anti-reflux stapling procedure. Materials and methods Trocars were placed in four animals and an articulating stapler was used to perform fundoplication under endoscopic guidance. Animals were monitored for 14 days post-procedure. Functional lumen imaging of the esophagogastric junction (EGJ) was performed at baseline, immediately post-intervention, and at 14 days. Results The procedure was successful in all animals who survived to day 14 without distress or significant adverse events. Baseline EGJ distensibility was 5.0 ± 1.2 mm2/mmHg, 2.7 ± 0.7 mm2/mmHg post-procedurally, and 3.0 ± 0.8mm2/mmHg on day 14. Average change in distensibility pre- and post-procedure was –2.3 ± 1.8 mm2/mmHg (95 % confidence interval [CI] –0.5 to 5.1, P = 0.08) while change in pre- and day 14 distensibility was –2.0 ± 1.4 mm2/mmHg (95 % CI –0.1 to 4.2, P = 0.06). Conclusions An intragastric trocar allows for use of large-diameter laparoscopic instruments to safely and effectively perform endoluminal fundoplication with anti-reflux properties that persist for at least 14 days.