Back to Authors

Group, EXALT Single-use Duodenoscope Study

Mayo Clinic

No affiliation available

Citations 1

Global prospective case series of ERCPs using a single-use duodenoscope
Bruno, Marco J. , Beyna, Torsten , Carr‐Locke, David L. , Chahal, Prabhleen , Costamagna, Guido , Devereaux, Benedict , Giovannini, Marc, Khor, Christopher , Lau, James Y., May, Gary R. , Muthusamy, V. Raman , Petersen, Bret T. , Raijman, Isaac , Reddy, D. Nageshwar , Ross, Andrew S., Sejpal, Divyesh V., Sherman, Stuart , Siddiqui, Uzma D. , Ziady, Christopher, Peetermans, Joyce , Rousseau, Matthew , Slivka, Adam, Group, EXALT Single-use Duodenoscope Study, Fichera, Alessandro , Pleskow, Douglas , Goenka, Mahesh Kumar , Patel, Sandeep , Petersen, Bret T. , Pleskow, Douglas K. , Repici, Alessandro , Group, EXALT Single-use Duodenoscope Study

Endoscopy | July 18, 2023 | Volume: 55 | Issue: 12 | Pages: 1103-1114

10.1055/a-2131-7180 Get It

Background The first commercialized single-use duodenoscope was cleared by the US Food and Drug Administration in December 2019. Data regarding endoscopic retrograde cholangiopancreatography (ERCP) using a single-use duodenoscope are needed on a broader range of cases conducted by endoscopists with varying levels of experience in a wide range of geographic areas. Methods 61 endoscopists at 22 academic centers in 11 countries performed ERCP procedures in adult patients aged ≥ 18. Outcomes included ERCP completion for the intended indication, rate of crossover to a reusable endoscope, device performance ratings, and serious adverse events (SAEs). Results Among 551 patients, 236 (42.8 %) were aged > 65, 281 (51.0 %) were men, and 256 (46.5 %) had their procedure as an inpatient. ERCPs included 196 (35.6 %) with American Society for Gastrointestinal Endoscopy complexity of grades 3–4. A total of 529 ERCPs (96.0 %) were completed: 503 (91.3 %) using only the single-use duodenoscope, and 26 (4.7 %) with crossover to a reusable endoscope. There were 22 ERCPs (4.0 %) that were not completed, of which 11 (2.0 %) included a crossover and 11 (2.0 %) were aborted cases (no crossover). Median ERCP completion time was 24.0 minutes. Median overall satisfaction with the single-use duodenoscope was 8.0 (scale of 1 to 10 [best]). SAEs were reported in 43 patients (7.8 %), including 17 (3.1 %) who developed post-ERCP pancreatitis. Conclusions In academic medical centers over a wide geographic distribution, endoscopists with varying levels of experience using the first marketed single-use duodenoscope had good ERCP procedural success and reported high performance ratings for this device.