Back to Authors

Schlachterman, Alexander

https://orcid.org/0000-0002-0633-7611

Mayo Clinic

University of Florida Health

Citations 5

US multicenter outcomes of endoscopic ultrasound-guided gallbladder drainage with lumen-apposing metal stents for acute cholecystitis
David, Yakira , Kakked, Gaurav, Confer, Bradley , Shah, Ruchit N. , Khara, Harshit S. , Diehl, David L. , Krafft, Matthew , Shah-Khan, Sardar M. , Nasr, John , Benias, Petros C. , Muniraj, Thiruvengadam , Aslanian, Harry R., Chahal, Prabhleen , Rodriguez, John , DuBroff, Jason, Latour, Rabi De, Khanna, Lauren , Haber, Gregory , Hoerter, Nicholas A. , Pandey, Nishi , Bakhit, Mena , Kowalski, Thomas E., Loren, David E. , Chiang, Austin , Schlachterman, Alexander , Nieto, Jose , Ichkhanian, Yervant , Khashab, Mouen A. , Halabi, Maan El , Kwon, Richard S. , Hernandez-Lara, Ariosto, Poneros, John M., Sethi, Amrita, Gonda, Tamas A. , Kushnir, Vladimir , Cosgrove, Natalie , Mullady, Daniel , Al-Shahrani, Abdullah , Buscaglia, Jonathan M. , Bucobo, Juan Carlos , Rolston, Vineet S. , Kedia, Prashant , Kasmin, Franklin, Kumta, Nikhil A. , DiMaio, Christopher J. , Krafft, Matthew Richard , Trindade, Arvind J. , Adler, Douglas G. , Tzimas, Demetrios J. , Goodman, Adam J. , Nieto, José , Deshmukh, Ameya A. , Prabhu, Anoop , Storm, Andrew C. , Berzin, Tyler M. , Sethi, Amrita , D'Souza, Lionel S. , Nagula, Satish

Endoscopy International Open | January 13, 2025 | Volume: 13 | Issue: CP | Pages: No page available

10.1055/a-2495-5542 Get It

AbstractEUS-guided gallbladder drainage (EUS-GBD) using lumen apposing metal stents (LAMS) has excellent technical and short-term clinical success for acute cholecystitis (AC). The goals of this study were to determine the long-term clinical outcomes and adverse events (AEs) of EUS-GBD with LAMS.A multicenter, retrospective study was conducted at 18 US tertiary care institutions. Inclusion criteria: any AC patient with attempted EUS-GBD with LAMS and minimum 30-day post-procedure follow-up. Long-term clinical success was defined as absence of recurrent acute cholecystitis (RAC) > 30 days and long-term AE was defined as occurring > 30 days from the index procedure.A total of 109 patients were included. Technical success was achieved in 108 of 109 (99.1%) and initial clinical success in 106 of 109 (97.2%). Long-term clinical success was achieved in 98 of 109 (89.9%) over a median follow-up of 140 days (range 30–1188). On multivariable analysis (MVA), acalculous cholecystitis (odds ratio [OR] 15.93, 95% confidence interval [CI] 1.22–208.52, P = 0.04) and the occurrence of a LAMS-specific AE (OR 63.60, 95% CI 5.08–799.29, P <0.01) were associated with RAC. AEs occurred in 38 of 109 patients (34.9%) at any time, and in 10 of 109 (9.17%) > 30 days from the index procedure. Most long-term AEs (7 of 109; 6.42%) were LAMS-specific. No technical or clinical factors were associated with occurrence of AEs. LAMS were removed in 24 of 109 patients (22%). There was no difference in RAC or AEs whether LAMS was removed or not.EUS-GBD with LAMS has a high rate of long-term clinical success and modest AE rates in patients with AC and is a reasonable destination therapy for high-risk surgical candidates.
Initial multicenter experience using a novel articulating through-the-scope traction device for endoscopic submucosal dissection
Hayat, Maham, Schlachterman, Alexander , Schiavone, Grace, Mizrahi, Meir, Kumbhari, Vivek , Cheesman, Antonio R., Hasan, Muhammad K. , Park, Jong Kyu, Park, Jong Kyu , Draganov, Peter V. , Yang, Dennis J.

Endoscopy International Open | June 26, 2023 | Volume: 11 | Issue: 08 | Pages: E778-E784

10.1055/a-2117-8444 Get It

Abstract Background and study aims A single-operator, articulating, through-the-scope (TTS) traction device was recently developed to facilitate endoscopic submucosal dissection (ESD). Clinical data on the performance of this device are limited. We report an initial multicenter experience with ESD using this articulating TTS traction device. Patients and methods Retrospective analysis on all consecutive patients who underwent ESD using this traction device (T-ESD) at five centers between August 2021 and December 2022. Endpoints included: rates of en-bloc resection, R0 resection, curative resection, and adverse events. Results Thirty-six patients (median age 64.8 years; 47.2% women) underwent ESD (median lesion size 40 mm; interquartile range [IRQ]: 27.5–67.5) for lesions in the esophagus (n=2), stomach (n=8), sigmoid colon (n=6), and rectum (n=20). Submucosal fibrosis was encountered in one-third of the lesions (33.3%). Median ESD time was 104.6 minutes (IQR: 65–122). En-bloc, R0 and curative resection were achieved in 94.4%, 91.6%, and 97.2%, respectively. The single patient with non-curative resection of an invasive rectal adenocarcinoma underwent surgery. There were no cases of delayed bleeding or perforation. There was no recurrence on surveillance endoscopy (n=20) at a median of 6 months (IQR: 3.75–6). Conclusions This initial multicenter experience demonstrates high resection rates and excellent safety profile when performing ESD with this novel articulating TTS device. Dynamic real-time traction may lower the technical difficulty of ESD. Additional studies are needed to assess its cost-effectiveness and compare its usefulness with other traction devices and techniques during ESD.
Through-the-scope suture closure of nonampullary duodenal endoscopic mucosal resection defects: a retrospective multicenter cohort study
Almario, Jose Antonio , Zhang, Linda Y. , Cohen, Jonathan , Haber, Gregory , Ramberan, Hemchand, Gordon, Stuart R. , Adler, Jeffrey M., Pohl, Heiko , Schlachterman, Alexander , Qumseya, Bashar , Kumta, Nikhil A. , Kim, Raymond , Aihara, Hiroyuki , Shrigiriwar, Apurva , Ngamruengphong, Saowanee , Khashab, Mouen A., group, Working, Storm, Andrew C , Canakis, Andrew , Storm, Andrew C. , Kumar, Anand , Singh, Shailendra , Draganov, Peter V. , Canakis, Andrew , Khashab, Mouen A. , group, Working

Endoscopy | May 19, 2023 | Volume: 55 | Issue: 09 | Pages: 865-870

10.1055/a-2077-4832 Get It

Background Delayed bleeding is among the most common adverse events associated with endoscopic mucosal resection (EMR) of nonampullary duodenal polyps. We evaluated the rate of delayed bleeding and complete defect closure using a novel through-the-scope (TTS) suturing system for the closure of duodenal EMR defects. Methods We reviewed the electronic medical records of patients who underwent EMR for nonampullary duodenal polyps of ≥ 10 mm and prophylactic defect closure with TTS suturing between March 2021 and May 2022 at centers in the USA. We evaluated the rates of delayed bleeding and complete defect closure. Results 36 nonconsecutive patients (61 % women; mean [SD] age, 65 [12] years) underwent EMR of ≥ 10-mm duodenal polyps followed by attempted defect closure with TTS suturing. The mean (SD) lesion size was 29 (19) mm, defect size was 37 (25) mm; eight polyps (22 %) involved > 50 % of the lumen circumference. Complete closure was achieved in all cases (78 % with TTS suturing alone), using a median of one TTS suturing kit. There were no cases of delayed bleeding and no adverse events attributed to application of the TTS suturing device. Conclusion Prophylactic closure of nonampullary duodenal EMR defects using TTS suturing resulted in a high rate of complete closure and no delayed bleeding events.
A novel through-the-scope helix tack-and-suture device for mucosal defect closure following colorectal endoscopic submucosal dissection: a multicenter study
Farha, Jad , Ramberan, Hemchand, Aihara, Hiroyuki , Zhang, Linda Y. , Mehta, Amit , Hage, Camille , Schlachterman, Alexander , Kumar, Anand , Shinn, Brianna , Canakis, Andrew , Kim, Raymond E., Buscaglia, Jonathan M. , Samarasena, Jason , Chang, Kenneth J. , Friedland, Shai , Qumseya, Bashar , Jawaid, Salmaan , Othman, Mohamed O. , Hasan, Muhammad K. , Khashab, Mouen A., Ngamruengphong, Saowanee , group, ESD-Closure working, Storm, Andrew C , Othman, Mohamed O , Canakis, Andrew , D'Souza, Lionel S. , Storm, Andrew C. , Draganov, Peter V. , Yang, Dennis J. , Khashab, Mouen A. , group, ESD-Closure working

Endoscopy | November 3, 2022 | Volume: 55 | Issue: 06 | Pages: 571-577

10.1055/a-1970-5528 Get It

Background Complete closure of large mucosal defects following colorectal endoscopic submucosal dissection (ESD) with through-the-scope (TTS) clips is oftentimes not possible. We aimed to report our early experience of using a novel TTS suturing system for the closure of large mucosal defects after colorectal ESD. Methods We performed a retrospective multicenter cohort study of consecutive patients who underwent attempted prophylactic defect closure using the TTS suturing system after colorectal ESD. The primary outcome was technical success in achieving complete defect closure, defined as a < 5 mm residual mucosal defect in the closure line using TTS suturing, with or without adjuvant TTS clips. Results 82 patients with a median defect size of 30 (interquartile range 25–40) mm were included. Technical success was achieved in 92.7 % (n = 76): TTS suturing only in 44 patients (53.7 %) and a combination of TTS suturing to approximate the widest segment followed by complete closure with TTS clips in 32 (39.0 %). Incomplete/partial closure, failure of appropriate TTS suture deployment, and the need for over-the-scope salvage closure methods were observed in 7.3 % (n = 6). One intraprocedural bleed, one delayed bleed, and three intraprocedural perforations were observed. There were no adverse events related to placement of the TTS suture. Conclusion The TTS suture system is an effective and safe tool for the closure of large mucosal defects after colorectal ESD and is an alternative when complete closure with TTS clips alone is not possible.