Objective: The purpose of this study was to evaluate the potential clinical value of spectral CT for image guidance during percutaneous thermal ablation, particularly investigating high monoenergetic (MonoE) for metal artifact reduction. Materials and Methods: A phantom experiment was performed in which an ablation probe was scanned in “continuous CT” (CCT) mode on a spectral CT scanner. ROI measurements quantified metal artifacts for conventional and MonoE CCT images. Subsequently, a retrospective reader study was conducted with 10 patient cases. Three radiologists reviewed cases to select the optimal MonoE setting and perform a Likert score rating (+2: MonoE preferred, −2: conventional preferred). Results: Phantom measurements indicated a reduction in metal artifact for high MonoE (150 keV: −46 HU) relative to conventional CCT (−122 HU). The MonoE setting preference was 151±21 keV. The mean Likert score was 1.2±0.7. Radiologists indicated a perceived benefit of high MonoE CCT when probe placement was near a critical structure. Conclusions: This study indicates a clinical preference for high MonoE CCT compared with conventional CCT. Insofar as spectral CCT can be offered at a clinically feasible time frame, our results support the assessment of 150 keV image to reduce metal artifact while maintaining satisfactory soft tissue contrast.
AbstractIntroductionUsing diagnostic CT for radiotherapy (RT) planning can bypass traditional CT simulation but introduces challenges in patient positioning and Hounsfield unit (HU) fidelity, affecting dose accuracy. Here a Varian Ethos adaptive‐driven CT direct‐to‐treatment (DtT) multi‐fraction stereotactic body radiation therapy (SBRT) workflow is presented.MethodsThis study employed institutional diagnostic PET‐CT images to generate an initial reference Ethos treatment plan. HU and dosimetric accuracy were validated for PET‐CT, Ethos CBCT images (with and without Hypersight (HS), and the gold‐standard helical CT simulators). Following the SBRT reference plan creation on the low dose diagnostic PET‐CT, the first fraction was delivered with a newly generated adaptive plan calculated on the HS CBCT (Ethos) images. For multi‐fraction treatments, the first day CBCT images and adaptive plan become the reference for subsequent IGRT treatments. This study includes workflow validation and initial three patient experience.ResultsThe DtT adaptive SBRT workflow was successfully implemented, with initial end‐to‐end testing demonstrating feasibility. In‐house solutions were introduced to facilitate the adaptive to IGRT plan conversion. The Ethos system, especially with HS, maintained HU fidelity and dose calculation accuracy comparable to helical CTs. On‐table adaptive sessions were within 37–51 min, aligning with single‐fraction palliative studies. Subsequent non‐adaptive IGRT fractions were efficiently completed within 7–27 min.ConclusionsThis study demonstrates the feasibility of DtT adaptive‐driven multifraction SBRT using diagnostic PET‐CT. This approach reduces the need for on‐site patient presence prior to treatment, expands planning lead times, and improves overall efficiency in radiotherapy for well selected patients.
Photon-counting detector CT in musculoskeletal imaging: benefits and outlook
Abstract Photon-counting detector CT (PCD-CT) represents a significant advancement in medical imaging, particularly for musculoskeletal (MSK) applications. Its primary innovation lies in enhanced spatial resolution, which facilitates improved detection of small anatomical structures such as trabecular bone, osteophytes, and subchondral cysts. PCD-CT enables high-quality imaging with reduced radiation doses, making it especially beneficial for populations requiring frequent imaging, such as paediatric patients and individuals with multiple myeloma. Additionally, PCD-CT supports advanced applications like bone quality assessment, which correlates well with gold-standard tests, and can aid in diagnosing osteoporosis and assessing fracture risk. Techniques such as spectral shaping and virtual monoenergetic imaging further optimize the technology, minimizing artefacts and enhancing material decomposition. These capabilities extend to conditions like gout and haematologic malignancies, offering improved detection and assessment. The integration of artificial intelligence could enhance PCD-CT’s performance by reducing image noise and improving quantitative assessments. Ultimately, PCD-CT’s superior resolution, reduced dose protocols, and multi-energy imaging capabilities will likely have a transformative impact on MSK imaging, improving diagnostic accuracy, patient care, and clinical outcomes.
Quantitative CT imaging: where are we, and what is missing?
Abstract Quantitative computed tomography (CT) enables the measurement of biophysical processes characterized by morphology, composition, flow, and/or motion to aid in clinical diagnosis and intervention. Since its initial application for determining bone mineral density for skeletal fragility assessment, quantitative CT has continued to evolve alongside CT’s technological advancements. A key challenge facing quantitative CT is the lack of standardization pertinent to image acquisition, reconstruction, and image analysis. With the introduction of spectral CT involving dual-energy approaches and photon-counting detectors (PCD), we are now able to obtain detailed information regarding mass densities of endogenous and exogeneous materials. Furthermore, energy-resolved CT yields spectral image types (eg, virtual monoenergetic image) that are, in principle, independent of tube potential and patient size. This paves the way for workflow standardization and helps improve the consistency and reproducibility of CT-derived measurements. In this article, we review clinical applications of quantitative CT, discuss key challenges associated with quantitative CT and its adoption into routine practice, and outline the unique benefits ushered by new CT technologies such as PCD-CT towards improving quantitative imaging.
Photon Counting Detector CTA for Prostate Artery Embolization Pre-Procedure Planning and Intra-Procedural Guidance: A Case Series
Abstract Background: Prostate artery embolization (PAE) requires a careful understanding of pelvic arterial anatomy and identifying prostatic artery variants. Pre-procedure CTA and intra-procedural cone beam CT are traditional means of planning and performing PAE, with the latter providing guidance for embolization. Photon counting detector (PCD) CT is a novel technology enabling ultra-high spatial resolution (UHR) whole-body imaging, with reconstructed slices as thin as 200 um. For PAE, we obtain a single UHR PCD CT acquisition, which provides both detailed pre-procedure pelvic arterial anatomy information and a registration reference for intra-procedural embolization guidance. Case Presentation: In five patients who underwent technically successful PAE via a left transradial approach, the pre-procedure diagnostic UHR PCD prostate CTA delineated bilateral prostatic artery origins and course in all cases, as confirmed with conventional angiograms. Further, registration of the UHR PCD CT for embolization guidance was successful in all cases, augmenting vessel selection. No complication occurred. Conclusion: UHR PCD CT is a novel acquisition option that is well suited to PAE due to its ability to delineate small vessels. Further, our experience has shown that a single pre-procedure scan can also be utilized for intra-procedural embolization guidance, obviating the need for a traditional cone beam CT angiogram. Further research is needed to assess reductions in radiation dose, contrast use, and intra-procedural time with these techniques.
Opportunistic Bone Mineral Density Measurement Using Photon-Counting Detector CT Spectral Localizer Images: A Prospective Study
Abstract Objective . Conventional computed tomography (CT) imaging does not provide quantitative information on local thermal changes during percutaneous ablative therapy of cancerous and benign tumors, aside from few qualitative, visual cues. In this study, we have investigated changes in CT signal across a wide range of temperatures and two physical phases for two different tissue mimicking materials, each. Approach . A series of experiments were conducted using an anthropomorphic phantom filled with water-based gel and olive oil, respectively. Multiple, clinically used ablation devices were applied to locally cool or heat the phantom material and were arranged in a configuration that produced thermal changes in regions with inconsequential amounts of metal artifact. Eight fiber optic thermal sensors were positioned in the region absent of metal artifact and were used to record local temperatures throughout the experiments. A spectral CT scanner was used to periodically acquire and generate electron density weighted images. Average electron density weighted values in 1 mm 3 volumes of interest near the temperature sensors were computed and these data were then used to calculate thermal volumetric expansion coefficients for each material and phase. Main results . The experimentally determined expansion coefficients well-matched existing published values and variations with temperature—maximally differing by 5% of the known value. As a proof of concept, a CT-generated temperature map was produced during a heating time point of the water-based gel phantom, demonstrating the capability to map changes in electron density weighted signal to temperature. Significance . This study has demonstrated that spectral CT can be used to estimate local temperature changes for different materials and phases across temperature ranges produced by thermal ablations.
Task-based automatic keV selection: leveraging routine virtual monoenergetic imaging for dose reduction on clinical photon-counting detector CT
*
Abstract Objective . Photon-counting detector (PCD) CT enables routine virtual-monoenergetic image (VMI) reconstruction. We evaluated the performance of an automatic VMI energy level (keV) selection tool on a clinical PCD-CT system in comparison to an automatic tube potential (kV) selection tool from an energy-integrating-detector (EID) CT system from the same manufacturer. Approach. Four torso-shaped phantoms (20–50 cm width) containing iodine (2, 5, and 10 mg cc −1 ) and calcium (100 mg cc −1 ) were scanned on PCD-CT and EID-CT. Dose optimization techniques, task-based VMI energy level and tube-potential selection on PCD-CT (CARE keV) and task-based tube potential selection on EID-CT (CARE kV), were enabled. CT numbers, image noise, and dose-normalized contrast-to-noise ratio (CNR d ) were compared. Main results . PCD-CT produced task-specific VMIs at 70, 65, 60, and 55 keV for non-contrast, bone, soft tissue with contrast, and vascular settings, respectively. A 120 kV tube potential was automatically selected on PCD-CT for all scans. In comparison, EID-CT used x-ray tube potentials from 80 to 150 kV based on imaging task and phantom size. PCD-CT achieved consistent dose reduction at 9%, 21% and 39% for bone, soft tissue with contrast, and vascular tasks relative to the non-contrast task, independent of phantom size. On EID-CT, dose reduction factor for contrast tasks relative to the non-contrast task ranged from a 65% decrease (vascular task, 70 kV, 20 cm phantom) to a 21% increase (soft tissue with contrast task, 150 kV, 50 cm phantom) due to size-specific tube potential adaptation. PCD-CT CNR d was equivalent to or higher than those of EID-CT for all tasks and phantom sizes, except for the vascular task with 20 cm phantom, where 70 kV EID-CT CNR d outperformed 55 keV PCD-CT images. Significance . PCD-CT produced more consistent CT numbers compared to EID-CT due to standardized VMI output, which greatly benefits standardization efforts and facilitates radiation dose reduction.
Staging of breast cancer in the breast and regional lymph nodes using contrast-enhanced photon-counting detector CT: accuracy and potential impact on patient management
Abstract Objectives To describe the feasibility and evaluate the performance of multiphasic photon-counting detector (PCD) CT for detecting breast cancer and nodal metastases with correlative dynamic breast MRI and digital mammography as the reference standard. Methods Adult females with biopsy-proven breast cancer undergoing staging breast MRI were prospectively recruited to undergo a multiphasic PCD-CT using a 3-phase protocol: a non-contrast ultra-high-resolution (UHR) scan and 2 intravenous contrast-enhanced scans with 50 and 180 s delay. Three breast radiologists compared CT characteristics of the index malignancy, regional lymphadenopathy, and extramammary findings to MRI. Results Thirteen patients underwent both an MRI and PCD-CT (mean age: 53 years, range: 36-75 years). Eleven of thirteen cases demonstrated suspicious mass or non-mass enhancement on PCD-CT when compared to MRI. All cases with metastatic lymphadenopathy (3/3 cases) demonstrated early avid enhancement similar to the index malignancy. All cases with multifocal or multicentric disease on MRI were also identified on PCD-CT (3/3 cases), including a 4 mm suspicious satellite lesion. Four of five patients with residual suspicious post-biopsy calcifications on mammograms were detected on the UHR PCD-CT scan. Owing to increased field-of-view at PCD-CT, a 5 mm thoracic vertebral metastasis was identified at PCD-CT and not with the breast MRI. Conclusions A 3-phase PCD-CT scan protocol shows initial promising results in characterizing breast cancer and regional lymphadenopathy similar to MRI and detects microcalcifications in 80% of cases. Advances in knowledge UHR and spectral capabilities of PCD-CT may allow for comprehensive characterization of breast cancer and may represent an alternative to breast MRI in select cases.
Establishing a quality assurance program for photon counting detector (PCD) CT: Tips and caveats
AbstractPurposeTo determine the suitability of a quality assurance (QA) program based on the American College of Radiology's (ACR) CT quality control (QC) manual to fully evaluate the unique capabilities of a clinical photon‐counting‐detector (PCD) CT system.MethodsA daily QA program was established to evaluate CT number accuracy and artifacts for both standard and ultra‐high‐resolution (UHR) scan modes. A complete system performance evaluation was conducted in accordance with the ACR CT QC manual by scanning the CT Accreditation Phantom with routine clinical protocols and reconstructing low‐energy‐threshold (T3D) and virtual monoenergetic images (VMIs) between 40 and 120 keV. Spatial resolution was evaluated by computing the modulation transfer function (MTF) for the UHR mode, and multi‐energy performance was evaluated by scanning a body phantom containing four iodine inserts with concentrations between 2 and 15 mg I/cc.ResultsThe daily QA program identified instances when the detector needed recalibration or replacement. CT number accuracy was impacted by image type: CT numbers at 70 keV VMI were within the acceptable range (defined for 120 kV). Other keV VMIs and the T3D reconstruction had at least one insert with CT number outside the acceptable range. The limiting resolution was nearly 40 lp/cm based on MTF measurements, which far exceeds the 12 lp/cm maximum capability of the ACR phantom. The CT numbers in the iodine inserts were accurate on all VMIs (3.8% average percentage error), while the iodine concentrations had an average root mean squared error of 0.3 mg I/cc.ConclusionProtocols and parameters must be properly selected on PCD‐CT to meet current accreditation requirements with the ACR CT phantom. Use of the 70 keV VMI allowed passing all tests prescribed in the ACR CT manual. Additional evaluations such an MTF measurement and multi‐energy phantom scans are also recommended to comprehensively evaluate PCD‐CT scanner performance.