Objective: To evaluate the function and safety of the SteadiSet™ infusion set over a continuous 7-day wear period in adults with type 1 diabetes. Research Design and Methods: Participants used a SteadiSet infusion set with a t:slim X2™ insulin pump with Control-IQ™ technology, and either insulin aspart or insulin lispro, for a target of 7 days for 12 consecutive wear periods. Each set removed before 7 days was adjudicated by an independent committee to assess the cause of early removal and to determine whether criteria for primary or key secondary endpoints were met. Results: There were 260 participants who inserted 3028 infusion sets. For the primary endpoint, the Kaplan–Meier 7-day survival estimate was 95% (95% CI 94% to 96%). For the key secondary endpoint, which expanded the reasons for a failed infusion set, the Kaplan–Meier 7-day survival estimate was 84% (95% CI 82% to 86%). For both endpoints, the P value was <0.001 compared with a prespecified survival rate of 75%. Time-in-range 70–180 mg/dL (TIR) increased through day 3 of set wear and then decreased through day 7, with the average TIR being 70.6% over the entire wear period across all infusion sets, including those that failed. An increase in total daily insulin was observed from day 4 through day 7. Conclusions: The 7-day survival of the SteadiSet infusion set was very high for the primary endpoint and at an acceptable level with respect to early removal for any reason related to the device.
Adults With Type 2 Diabetes Benefit From Automated Insulin Delivery Irrespective of C-Peptide Level
OBJECTIVE The Centers for Medicare & Medicaid Services (CMS) requires a low C-peptide level for insulin pump coverage unless the individual is β-cell autoantibody positive, which precludes coverage of automated insulin delivery (AID) systems for many people with type 2 diabetes. RESEARCH DESIGN AND METHODS In the Randomized Trial Evaluating the Efficacy and Safety of Control-IQ+ Technology in Adults With Type 2 Diabetes Using Basal-Bolus Insulin Therapy study evaluating the t:slim X2 insulin pump with Control-IQ+ technology, adults with insulin-treated type 2 diabetes were categorized into high C-peptide (n = 195) and low C-peptide (n = 59) groups based on CMS criteria. RESULTS In the AID group, mean HbA1c decreased from baseline by 0.8%, which was significantly greater than in the control group with both high (P < 0.001) and low (P = 0.02) C-peptide levels. Results were similar in participants ≥65 years old. CONCLUSIONS The benefit of AID is present with high and low C-peptide levels. Thus, requiring a low C-peptide level as a prerequisite for AID therapy is not warranted.
A 13-Week Single-Arm Evaluation of Inhaled Technosphere Insulin Plus Insulin Degludec for Adults with Type 1 Diabetes
OBJECTIVE To evaluate a regimen of inhaled Technosphere insulin (TI) plus insulin degludec in adults with type 1 diabetes, who prestudy were predominately using either an automated insulin delivery (AID) system or multiple daily insulin injections (MDI) with continuous glucose monitoring. RESEARCH DESIGN AND METHODS At 19 sites, adults with type 1 diabetes were randomly assigned to TI plus insulin degludec (N = 62) or usual care (UC) with continuation of prestudy insulin delivery method (N = 61) for 17 weeks. RESULTS Prestudy, AID was used by 48% and MDI by 45%. Mean ± SD HbA1c was 7.57% ± 0.97% at baseline and 7.62% ± 1.06% at 17 weeks in the TI group and 7.59% ± 0.80% and 7.54% ± 0.77%, respectively, in the UC group (adjusted difference 0.11%, 95% CI −0.10 to 0.33, P value for noninferiority = 0.01). HbA1c improved from baseline to 17 weeks by >0.5% (5.5 mmol/mol) in 12 (21%) in the TI group and in 3 (5%) in the UC group and worsened by >0.5% (5.5 mmol/mol) in 15 (26%) in the TI group and in 2 (3%) in the UC group. The most common TI side effect was a brief cough; eight participants discontinued TI due to side effects. CONCLUSIONS In adults with type 1 diabetes, HbA1c after 17 weeks with a regimen of TI and degludec was noninferior to UC, which consisted predominately of either AID or MDI. TI should be considered an option for people with type 1 diabetes, particularly those who are motivated to further reduce postprandial hyperglycemia.
A Randomized Comparison of Postprandial Glucose Excursion Using Inhaled Insulin Versus Rapid-Acting Analog Insulin in Adults With Type 1 Diabetes Using Multiple Daily Injections of Insulin or Automated Insulin Delivery
OBJECTIVE To compare postprandial glucose excursions following a bolus with inhaled technosphere insulin (TI) or subcutaneous rapid-acting analog (RAA) insulin. RESEARCH DESIGN AND METHODS A meal challenge was completed by 122 adults with type 1 diabetes who were using multiple daily injections (MDI), a nonautomated pump, or automated insulin delivery (AID) and who were randomized to bolus with their usual RAA insulin (n = 61) or TI (n = 61). RESULTS The primary outcome, the treatment group difference in area under the curve for glucose >180 mg/dL over 2 h, was less with TI versus RAA (adjusted difference −12 mg/dL, 95% CI −22 to −2, P = 0.02). With TI, the glucose excursion was smaller (P = 0.01), peak glucose lower (P = 0.01), and time to peak glucose shorter (P = 0.006). Blood glucose <70 mg/dL occurred in one participant in each group. CONCLUSIONS Postmeal glucose excursion was smaller with TI than with RAA insulin in a cohort that included both AID and MDI users.
Beneficial Effects of Glucagon-Like Peptide 1 (GLP-1) Receptor Agonist Use With Control-IQ Technology in Type 2 Diabetes
OBJECTIVE Limited information is available about glycemic outcomes with a closed-loop control (CLC) system compared with a predictive low-glucose suspend (PLGS) system. RESEARCH DESIGN AND METHODS After 6 months of use of a CLC system in a randomized trial, 109 participants with type 1 diabetes (age range, 14–72 years; mean HbA1c, 7.1% [54 mmol/mol]) were randomly assigned to CLC (N = 54, Control-IQ) or PLGS (N = 55, Basal-IQ) groups for 3 months. The primary outcome was continuous glucose monitor (CGM)-measured time in range (TIR) for 70–180 mg/dL. Baseline CGM metrics were computed from the last 3 months of the preceding study. RESULTS All 109 participants completed the study. Mean ± SD TIR was 71.1 ± 11.2% at baseline and 67.6 ± 12.6% using intention-to-treat analysis (69.1 ± 12.2% using per-protocol analysis excluding periods of study-wide suspension of device use) over 13 weeks on CLC vs. 70.0 ± 13.6% and 60.4 ± 17.1% on PLGS (difference = 5.9%; 95% CI 3.6%, 8.3%; P < 0.001). Time >180 mg/dL was lower in the CLC group than PLGS group (difference = −6.0%; 95% CI −8.4%, −3.7%; P < 0.001) while time <54 mg/dL was similar (0.04%; 95% CI −0.05%, 0.13%; P = 0.41). HbA1c after 13 weeks was lower on CLC than PLGS (7.2% [55 mmol/mol] vs. 7.5% [56 mmol/mol], difference −0.34% [−3.7 mmol/mol]; 95% CI −0.57% [−6.2 mmol/mol], −0.11% [1.2 mmol/mol]; P = 0.0035). CONCLUSIONS Following 6 months of CLC, switching to PLGS reduced TIR and increased HbA1c toward their pre-CLC values, while hypoglycemia remained similarly reduced with both CLC and PLGS.