At-Home Use of a Pregnancy-Specific Zone-MPC Closed-Loop System for Pregnancies Complicated by Type 1 Diabetes: A Single-Arm, Observational Multicenter Study
Levy, Carol J. , Kudva, Yogish C. , Özaslan, Başak , Castorino, Kristin , O’Malley, Grenye , Kaur, Ravinder Jeet , Levister, Camilla, Church, Mei Mei , Desjardins, Donna, McCrady-Spitzer, Shelly , Ogyaadu, Selassie, Trinidad, Mari Charisse, Reid, Corey, Rizvi, Shafaq, Kremers, Walter K. , Pinsker, Jordan E. , Dassau, Eyal , Zaniletti, Isabella, Dassau, Eyal , Levy, Carol J , Kremers, Walter K , Deshpande, Sunil , Zaniletti, Isabella , Doyle, Francis J.

Diabetes Care | May 17, 2023 | Volume: 46 | Issue: 7 | Pages: 1425-1431

10.2337/dc23-0173 Get It

OBJECTIVE There are no commercially available hybrid closed-loop insulin delivery systems customized to achieve pregnancy-specific glucose targets in the U.S. This study aimed to evaluate the feasibility and performance of at-home use of a zone model predictive controller–based closed-loop insulin delivery system customized for pregnancies complicated by type 1 diabetes (CLC-P). RESEARCH DESIGN AND METHODS Pregnant women with type 1 diabetes using insulin pumps were enrolled in the second or early third trimester. After study sensor wear collecting run-in data on personal pump therapy and 2 days of supervised training, participants used CLC-P targeting 80–110 mg/dL during the day and 80–100 mg/dL overnight running on an unlocked smartphone at home. Meals and activities were unrestricted throughout the trial. The primary outcome was the continuous glucose monitoring percentage of time in the target range 63–140 mg/dL versus run-in. RESULTS Ten participants (HbA1c 5.8 ± 0.6%) used the system from mean gestational age of 23.7 ± 3.5 weeks. Mean percentage time in range increased 14.1 percentage points, equivalent to 3.4 h per day, compared with run-in (run-in 64.5 ± 16.3% versus CLC-P 78.6 ± 9.2%; P = 0.002). During CLC-P use, there was significant decrease in both time over 140 mg/dL (P = 0.033) and the hypoglycemic ranges of less than 63 mg/dL and 54 mg/dL (P = 0.037 for both). Nine participants exceeded consensus goals of above 70% time in range during CLC-P use. CONCLUSIONS The results show that the extended use of CLC-P at home until delivery is feasible. Larger, randomized studies are needed to further evaluate system efficacy and pregnancy outcomes.
Hypoglycemia in Prospective Multicenter Study of Pregnancies with Pre-Existing Type 1 Diabetes on Sensor-Augmented Pump Therapy: The LOIS-P Study
Kaur, Ravinder Jeet , Özaslan, Başak , Pinsker, Jordan E. , Trinidad, Mari Charisse, O’Malley, Grenye , Desjardins, Donna, Castorino, Kristin , Levister, Camilla, Reid, Corey, McCrady-Spitzer, Shelly , Ogyaadu, Selassie, Church, Mei Mei , Piper, Molly, Kremers, Walter K. , Rosenn, Barak, Dassau, Eyal , Kudva, Yogish C. , Doyle, Francis J , Dassau, Eyal , Kudva, Yogish C. , Kremers, Walter K , Smith, Byron H. , Doyle, Francis J. , Levy, Carol J.

Diabetes Technology & Therapeutics | March 29, 2022 | Volume: 24 | Issue: 8 | Pages: 544-555

10.1089/dia.2021.0479 Get It

Background: Pregnancies in type 1 diabetes are high risk, and data in the United States are limited regarding continuous glucose monitoring (CGM)-based hypoglycemia throughout pregnancy while on sensor-augmented insulin pump therapy. Materials and Methods: Pregnant women with type 1 diabetes in the LOIS-P Study (Longitudinal Observation of Insulin use and glucose Sensor metrics in Pregnant women with type 1 diabetes using continuous glucose monitors and insulin pumps) were enrolled before 17 weeks gestation at three U.S. centers and we used their personal insulin pump and a study Dexcom G6 CGM. We analyzed data of 25 pregnant women for CGM hypoglycemia based on international consensus guidelines for percentage time <63 and 54 mg/dL, hypoglycemic events and prolonged hypoglycemia events for 24-h, daytime, and overnight periods, and severe hypoglycemia (SH) episodes. Results: For a 24-h period, biweekly median percentage of time <63 mg/dL ranged from 0.8% at biweek 4–5 to 3.7% at biweek 14–15 with high variability throughout pregnancy. Median percentage of time <63 and 54 mg/dL was higher overnight than daytime ( P < 0.01). Hypoglycemic events occurred throughout the pregnancy, ranged 1–4 events per 2 weeks, significantly decreased after the 20th week, and occurred predominantly during daytime ( P < 0.01). For overnight period, hypoglycemia and events were more concentrated from 12 to 3 am. Seven prolonged hypoglycemia events without any associated SH occurred in four participants (16%), primarily overnight. Three participants experienced a single episode of SH. Conclusions: Our results suggest a higher overall risk of hypoglycemia throughout pregnancy during the overnight period with continued daytime risk of hypoglycemic events in pregnancies complicated by type 1 diabetes.
Feasibility of Closed-Loop Insulin Delivery with a Pregnancy-Specific Zone Model Predictive Control Algorithm
Özaslan, Başak , Kudva, Yogish C. , Pinsker, Jordan E. , O’Malley, Grenye , Kaur, Ravinder Jeet , Castorino, Kristin , Levister, Camilla, Trinidad, Mari Charisse, Desjardins, Donna, Church, Mei Mei , Plesser, Mitchell, McCrady-Spitzer, Shelly , Ogyaadu, Selassie, Nelson, Kristen L., Reid, Corey, Kremers, Walter K. , Rosenn, Barak, Dassau, Eyal , Kudva, Yogish C. , Doyle, Francis J , Dassau, Eyal , Kremers, Walter K , Levy, Carol J. , Nelson, Kristen, Deshpande, Sunil , Doyle, Francis J.

Diabetes Technology & Therapeutics | March 1, 2022 | Volume: 24 | Issue: 7 | Pages: 471-480

10.1089/dia.2021.0521 Get It

Objective: Evaluating the feasibility of closed-loop insulin delivery with a zone model predictive control (zone-MPC) algorithm designed for pregnancy complicated by type 1 diabetes (T1D). Research Design and Methods: Pregnant women with T1D from 14 to 32 weeks gestation already using continuous glucose monitor (CGM) augmented pump therapy were enrolled in a 2-day multicenter supervised outpatient study evaluating pregnancy-specific zone-MPC based closed-loop control (CLC) with the interoperable artificial pancreas system (iAPS) running on an unlocked smartphone. Meals and activities were unrestricted. The primary outcome was the CGM percentage of time between 63 and 140 mg/dL compared with participants' 1-week run-in period. Early (2-h) postprandial glucose control was also evaluated. Results: Eleven participants completed the study (age: 30.6 ± 4.1 years; gestational age: 20.7 ± 3.5 weeks; weight: 76.5 ± 15.3 kg; hemoglobin A1c: 5.6% ± 0.5% at enrollment). No serious adverse events occurred. Compared with the 1-week run-in, there was an increased percentage of time in 63–140 mg/dL during supervised CLC (CLC: 81.5%, run-in: 64%, P = 0.007) with less time >140 mg/dL (CLC: 16.5%, run-in: 30.8%, P = 0.029) and time <63 mg/dL (CLC: 2.0%, run-in:5.2%, P = 0.039). There was also less time <54 mg/dL (CLC: 0.7%, run-in:1.6%, P = 0.030) and >180 mg/dL (CLC: 4.9%, run-in: 13.1%, P = 0.032). Overnight glucose control was comparable, except for less time >250 mg/dL (CLC: 0%, run-in:3.9%, P = 0.030) and lower glucose standard deviation (CLC: 23.8 mg/dL, run-in:42.8 mg/dL, P = 0.007) during CLC. Conclusion: In this pilot study, use of the pregnancy-specific zone-MPC was feasible in pregnant women with T1D. Although the duration of our study was short and the number of participants was small, our findings add to the limited data available on the use of CLC systems during pregnancy (NCT04492566).
Outpatient Randomized Crossover Automated Insulin Delivery Versus Conventional Therapy with Induced Stress Challenges
Kaur, Ravinder Jeet , Pinsker, Jordan E. , Gilliam, Wesley P. , McCrady-Spitzer, Shelly , Desjardins, Donna, Church, Mei Mei , Kremers, Walter K. , Dassau, Eyal , Kudva, Yogish C. , Pinsker, Jordan E , Zaniletti, Isabella, Dassau, Eyal , Kudva, Yogish C. , Kremers, Walter K , Deshpande, Sunil , Zaniletti, Isabella , Doyle, Francis J.

Diabetes Technology & Therapeutics | January 20, 2022 | Volume: 24 | Issue: 5 | Pages: 338-349

10.1089/dia.2021.0436 Get It

Background: Automated insulin delivery (AID) systems have not been evaluated in the context of psychological and pharmacological stress in type 1 diabetes. Our objective was to determine glycemic control and insulin use with Zone Model Predictive Control (zone-MPC) AID system enhanced for states of persistent hyperglycemia versus sensor-augmented pump (SAP) during outpatient use, including in-clinic induced stress. Materials and Methods: Randomized, crossover, 2-week trial of zone-MPC AID versus SAP in 14 adults with type 1 diabetes. In each arm, each participant was studied in-clinic with psychological stress induction (Trier Social Stress Test [TSST] and Socially Evaluated Cold Pressor Test [SECPT]), followed by pharmacological stress induction with oral hydrocortisone (total four sessions per participant). The main outcomes were 2-week continuous glucose monitor percent time in range (TIR) 70–180 mg/dL, and glucose and insulin outcomes during and overnight following stress induction. Results: During psychological stress, AID decreased glycemic variability percentage by 13.4% ( P = 0.009). During pharmacological stress, including the following overnight, there were no differences in glucose outcomes and total insulin between AID and physician-assisted SAP. However, with AID total user-requested insulin was lower by 6.9 U ( P = 0.01) for pharmacological stress. Stress induction was validated by changes in heart rate and salivary cortisol levels. During the 2-week AID use, TIR was 74.4% (vs. SAP 63.1%, P = 0.001) and overnight TIR was 78.3% (vs. SAP 63.1%, P = 0.004). There were no adverse events. Conclusions: Zone-MPC AID can reduce glycemic variability and the need for user-requested insulin during pharmacological stress and can improve overall glycemic outcomes. Clinical Trial Identifier NCT04142229.
Longitudinal Observation of Insulin Use and Glucose Sensor Metrics in Pregnant Women with Type 1 Diabetes Using Continuous Glucose Monitors and Insulin Pumps: The LOIS-P Study
O’Malley, Grenye , Özaslan, Başak , Levy, Carol J. , Castorino, Kristin , Desjardins, Donna, Levister, Camilla, McCrady-Spitzer, Shelly , Church, Mei Mei , Kaur, Ravinder Jeet , Reid, Corey, Kremers, Walter K. , Trinidad, Mari Charisse, Rosenn, Barak, Pinsker, Jordan E. , Kudva, Yogish C. , Dassau, Eyal , Doyle, Francis J , Pinsker, Jordan E , Kudva, Yogish C. , Dassau, Eyal , Levy, Carol J , Kremers, Walter K , Castorino, Kristin , Doyle, Francis J.

Diabetes Technology & Therapeutics | July 16, 2021 | Volume: 23 | Issue: 12 | Pages: 807-817

10.1089/dia.2021.0112 Get It

Background: Suboptimal glycemic control is associated with maternal and neonatal morbidity and mortality in pregnancy complicated by type 1 diabetes (T1D). Prospective analysis of continuous glucose monitoring (CGM) metrics, insulin pump settings, and insulin delivery can better characterize the changes in glycemic levels and insulin use throughout pregnancy with T1D. Materials and Methods: Prescribed parameters, insulin delivery, carbohydrate intake, and CGM data for 25 pregnant women with T1D from three U.S. sites were collected. Participants enrolled before 17 weeks gestation and used personal insulin pumps and study CGM. Mean daily total, basal, and bolus insulin doses (units/kg), CGM time in range (TIR: 63–140 mg/dL), and pump-entered carbohydrates were analyzed for every 2-week gestational interval. Linear mixed-effects regression models were used to evaluate changes across gestational ages compared to 12–14 weeks. Results: Basal insulin was higher during weeks 6–12 and 24–40. Daily bolus and total insulin were higher during weeks 20–40. Pump parameters were adjusted to intensify insulin therapy from 22 weeks onward. Average TIR across pregnancy was 59% ± 14%. Between 18 and 30 weeks, TIR was significantly lower, and time above range was significantly higher compared to the reference biweek. Time below target was lower between 22 and 34 weeks. Seven participants achieved >70% recommended TIR for pregnancy. Participants with maternal complications or infant neonatal intensive care unit admissions had lower TIR. Conclusion: While insulin dosing changed significantly with advancing gestation, most participants did not achieve >70% TIR. Customized anticipatory pump setting adjustments and automated systems aimed toward the designated TIR are needed to improve outcomes for this population. NCT03761615
Use of the Interoperable Artificial Pancreas System for Type 1 Diabetes Management During Psychological Stress
Pinsker, Jordan E. , McCrady-Spitzer, Shelly , Church, Mei Mei , Kaur, Ravinder Jeet , Pérez, Jimena, Desjardins, Donna, Piper, Molly, Reid, Corey, Kudva, Yogish C. , Dassau, Eyal , Dassau, Eyal , Deshpande, Sunil , Perez, Jimena, Doyle, Francis J.

Journal of Diabetes Science and Technology | August 12, 2020 | Volume: 15 | Issue: 1 | Pages: 184-185

10.1177/1932296820948566 Get It

Glycemic Outcomes of Use of CLC Versus PLGS in Type 1 Diabetes: A Randomized Controlled Trial
Brown, Sue A. , Beck, Roy W. , Raghinaru, Dan, Buckingham, Bruce A. , Laffel, Lori M. , Kudva, Yogish C. , Pinsker, Jordan E. , Dassau, Eyal , Ambler-Osborn, Louise, Anderson, Stacey M. , Church, Mei Mei , Ekhlaspour, Laya , Forlenza, Gregory P. , Levister, Camilla, Simha, Vinaya , Breton, Marc D. , Kollman, Craig, Lum, John W. , Kovatchev, Boris , Emory, Emma, Voelmle, Mary, Conshafter, Katie, Morris, Kim, Gondor-Fredrick, Linda, Mitchell, Harry, Calvo, Kayla, Wakeman, Christian, Isganaitis, Elvira , Flint, Emily, Kim, Kenny, Roethke, Lindsay, André, Camille , Piper, Molly, Lam, David W. , O’Malley, Grenye , Ogyaadu, Selassie, Lovett, Jessica, Dadlani, Vikash, McCrady-Spitzer, Shelly , Reid, Corey, Slover, Robert H., Jost, Emily , Berget, Cari , Towers, Lindsey, Rossick-Solis, Alex, Jacobson, Tali, Town, Marissa, Tabatabai, Ideen , Keller, Jordan, Salas, Evalina, Passman, Samantha, Campos, Tiffany, Murphy, Carlos, Patibandla, Nandan, Borgman, Sarah, Arreza-Rubin, Guillermo, Eggerman, Thomas L., Green, Neal, Reznik, Yves , Janicek, Robert, Gabrielson, Deanna, Belle, Steven H., Castle, Jessica R. , Legault, Laurent , Wysham, Carol , Kudva, Yogish C. , Pinsker, Jordan E , Dassau, Eyal , Doyle, Francis J , Ekhlaspour, Laya , Forlenza, Gregory P , Breton, Marc D , Lum, John , Kovatchev, Boris , Buckingham, Bruce , Beck, Roy W , Wadwa, R Paul , Levy, Carol J. , Doyle, Francis J. , Kollman, Craig , Oliveri, Mary Clancy , Kumari, Kanchan , Alonso, G. Todd , Messer, Laurel H , Renard, Eric , Cobelli, Claudio , Green, Jennifer Greif , Willi, Steven Matthew

Diabetes Care | May 30, 2020 | Volume: 43 | Issue: 8 | Pages: 1822-1828

10.2337/dc20-0124 Get It

OBJECTIVE Limited information is available about glycemic outcomes with a closed-loop control (CLC) system compared with a predictive low-glucose suspend (PLGS) system. RESEARCH DESIGN AND METHODS After 6 months of use of a CLC system in a randomized trial, 109 participants with type 1 diabetes (age range, 14–72 years; mean HbA1c, 7.1% [54 mmol/mol]) were randomly assigned to CLC (N = 54, Control-IQ) or PLGS (N = 55, Basal-IQ) groups for 3 months. The primary outcome was continuous glucose monitor (CGM)-measured time in range (TIR) for 70–180 mg/dL. Baseline CGM metrics were computed from the last 3 months of the preceding study. RESULTS All 109 participants completed the study. Mean ± SD TIR was 71.1 ± 11.2% at baseline and 67.6 ± 12.6% using intention-to-treat analysis (69.1 ± 12.2% using per-protocol analysis excluding periods of study-wide suspension of device use) over 13 weeks on CLC vs. 70.0 ± 13.6% and 60.4 ± 17.1% on PLGS (difference = 5.9%; 95% CI 3.6%, 8.3%; P &lt; 0.001). Time &gt;180 mg/dL was lower in the CLC group than PLGS group (difference = −6.0%; 95% CI −8.4%, −3.7%; P &lt; 0.001) while time &lt;54 mg/dL was similar (0.04%; 95% CI −0.05%, 0.13%; P = 0.41). HbA1c after 13 weeks was lower on CLC than PLGS (7.2% [55 mmol/mol] vs. 7.5% [56 mmol/mol], difference −0.34% [−3.7 mmol/mol]; 95% CI −0.57% [−6.2 mmol/mol], −0.11% [1.2 mmol/mol]; P = 0.0035). CONCLUSIONS Following 6 months of CLC, switching to PLGS reduced TIR and increased HbA1c toward their pre-CLC values, while hypoglycemia remained similarly reduced with both CLC and PLGS.
Randomized Controlled Trial of Mobile Closed-Loop Control
Kovatchev, Boris , Anderson, Stacey M. , Raghinaru, Dan, Kudva, Yogish C. , Laffel, Lori M. , Pinsker, Jordan E. , Buckingham, Bruce A. , Doyle, Francis J. , Brown, Sue A. , Church, Mei Mei , Dadlani, Vikash, Dassau, Eyal , Ekhlaspour, Laya , Forlenza, Gregory P. , Isganaitis, Elvira , Lam, David W. , Lum, John W. , Group, iDCL Study, Emory, Emma, Voelmle, Mary, Conshafter, Katie, Morris, Kim, Mitchell, Harry, Calvo, Kayla, Wakeman, Christian, Breton, Marc D. , Ambler-Osborn, Louise, Flint, Emily, Schultz, Alan , Kim, Kenny, Church, Mei Mei, André, Camille , Lam, David W., O’Malley, Grenye , Levister, Camilla, Ogyaadu, Selassie, Simha, Vinaya , McCrady-Spitzer, Shelly , Reid, Corey, Jost, Emily , Berget, Cari , Towers, Lindsey, Buckingham, Bruce, Ekhlaspour, Laya, Hsu, Liana, Loebner, Sarah E., Doyle, Francis J., Campos, Tiffany, Passman, Samantha, Murphy, Carlos, Patibandla, Nandan, Kollman, Craig, Pinsker, Jordan E , Doyle, Francis J , Dassau, Eyal , Ekhlaspour, Laya , Forlenza, Gregory P , Lum, John , Kovatchev, Boris , Buckingham, Bruce , Levy, Carol J. , Wadwa, R Paul , Beck, Roy W. , Group, iDCL Study, Oliveri, Mary Clancy , Church, Mei Mei, Lam, David W., Messer, Laurel H , Buckingham, Bruce, Ekhlaspour, Laya, Doyle, Francis J., Kollman, Craig

Diabetes Care | January 15, 2020 | Volume: 43 | Issue: 3 | Pages: 607-615

10.2337/dc19-1310 Get It

OBJECTIVE Assess the efficacy of inControl AP, a mobile closed-loop control (CLC) system. RESEARCH DESIGN AND METHODS This protocol, NCT02985866, is a 3-month parallel-group, multicenter, randomized unblinded trial designed to compare mobile CLC with sensor-augmented pump (SAP) therapy. Eligibility criteria were type 1 diabetes for at least 1 year, use of insulin pumps for at least 6 months, age ≥14 years, and baseline HbA1c &lt;10.5% (91 mmol/mol). The study was designed to assess two coprimary outcomes: superiority of CLC over SAP in continuous glucose monitor (CGM)–measured time below 3.9 mmol/L and noninferiority in CGM-measured time above 10 mmol/L. RESULTS Between November 2017 and May 2018, 127 participants were randomly assigned 1:1 to CLC (n = 65) versus SAP (n = 62); 125 participants completed the study. CGM time below 3.9 mmol/L was 5.0% at baseline and 2.4% during follow-up in the CLC group vs. 4.7% and 4.0%, respectively, in the SAP group (mean difference −1.7% [95% CI −2.4, −1.0]; P &lt; 0.0001 for superiority). CGM time above 10 mmol/L was 40% at baseline and 34% during follow-up in the CLC group vs. 43% and 39%, respectively, in the SAP group (mean difference −3.0% [95% CI −6.1, 0.1]; P &lt; 0.0001 for noninferiority). One severe hypoglycemic event occurred in the CLC group, which was unrelated to the study device. CONCLUSIONS In meeting its coprimary end points, superiority of CLC over SAP in CGM-measured time below 3.9 mmol/L and noninferiority in CGM-measured time above 10 mmol/L, the study has demonstrated that mobile CLC is feasible and could offer certain usability advantages over embedded systems, provided the connectivity between system components is stable.