Back to Authors

Castorino, Kristin

0000-0001-6386-9203

Mayo Clinic

Sansum Diabetes Research Institute, Santa Barbara, CA.

Citations 3

A Randomized Trial Comparing Inhaled Insulin Plus Basal Insulin Versus Usual Care in Adults With Type 1 Diabetes
Hirsch, Irl B. , Beck, Roy W. , Marak, Martin Chase , Kudva, Yogish C. , Aktürk, Halis Kaan , Bhargava, Anuj , Codorniz, Kevin , Diner, Jamie, Aleppo, Grazia , Blevins, Thomas , Raskin, Philip, Castorino, Kristin , Manessis, Anastasios , Pickering, David, Weinstock, Ruth S. , Bode, Bruce W. , Nguyen, Quang T., Kipnes, Mark, Ruedy, Katrina J., Desjardins, Donna, Haider, Zehra, Jacobson, Christopher , Klein, Klara R. , O’Malley, Grenye , Church, Mei Mei , Mottalib, Adham , Baran, Jesica D., Kurek, Corey, Rizvi, Shafaq, Donahue, Cassandra, Tamarez, Denisa, Atakov-Castillo, Astrid , Borgman, Sarah, Frey, Sarah, Calhoun, Peter , Group, INHALE-3 Study, Ownby, Jonathan G., Johnson, Joseph H., Ruiz, Adriana, Stephens, Nashia, Maxson, Amanda, Akturk, Halis K., Beatson, Christie , Mason, E E , Wolpert, Howard , Sullivan, Asya, Salhin, Amna, Copple, Tina, Beltran, Stephanie, Ryan, Terri, Levister, Camilla, Ipek, Aslihan, Burke, Christine, Langel, Christine, Bauman, Shannon , Haight, Cristina, Bohr, A., Mottalib, Adham, Salah, Tareq , Badri, Marwa Al, Nguyen, Quang T., Nguyen, Loida, Cordero, Christian, Migliozzi, Brittney, Reid, Corey, Kaur, Ravinder Jeet , Livingood, Daine, Cruse, Dana, Kravarusic, Jelena, Coyne, Kasey, Herrmann, Stefanie, Fronczyk, Evelyn, Manessis, Anastasios, McKillop, Lorcan, Hyatt, Jamie, Patruno, Maria, Castorino, Kristin, Church, Mei Mei, Thorsell, Ashley, Shuirman, Maggie, Cobb, Brandon, Watt, Olivia, Bzdick, Suzan, Casaubon, Luis, Espinosa, Valerie, Pandit, Keta, Perez, Jennifer, Armstrong, Chloe, Martinez-Arredondo, Maritza, Stewart, Ana, Ghorbani, Tahereh, Young, Laura , Donahue, Cassandra, Kass, Alexander, Fulghum, Karla, Raskin, Philip, Jordan, Lin, Shao, Baomei, Hirsch, Irl B., Baran, Jesica, Mandava, Patali, Holod, Rosanna, Kaiserman, Kevin B. , Ulloa, Johanna, Pleitez, Jennifer, Sylvan, Joey, Badgett, Lynn, Frey, Sarah, Mba-Oduwusi, Nnenna, Miller, Paige , Fults, Ashleigh, Pritchard, Rosa, Dolzhenko, E. N. , Gabrielson, Deanna, Brown, Sue A. , Ahmann, Andrew , Bergenstal, Richard M. , Kudva, Yogish C. , Akturk, Halis K , Levy, Carol J , Castorino, Kristin , Steenkamp, Devin W , Weinstock, Ruth S , Hamdy, Osama , Klein, Klara R , Church, Mei Mei , Mottalib, Adham , Calhoun, Peter , Hirsch, Irl B , Aleppo, Grazia , Beck, Roy W , Levy, Carol J. , Nguyen, Quang T., Lee, Scott Jeffery , Buse, John B. , Donahue, Cassandra, Borgman, Sarah, Calhoun, Peter , Group, INHALE-3 Study, Akturk, Halis K., Mason, Emma, Bauman, Shannon, Mottalib, Adham, Dhaver, Shilton , Nguyen, Quang T., Manessis, Anastasios, Castorino, Kristin, Church, Mei Mei, Johnson, Olivia, Coviello, Andrea D. , Donahue, Cassandra, Raskin, Philip, Hirsch, Irl B., Ulloa, Johanna, Frey, Sarah, Miller, Paige, McCarthy, Chris

Diabetes Care | December 6, 2024 | Volume: 48 | Issue: 3 | Pages: 353-360

10.2337/dc24-1832 Get It

OBJECTIVE To evaluate a regimen of inhaled Technosphere insulin (TI) plus insulin degludec in adults with type 1 diabetes, who prestudy were predominately using either an automated insulin delivery (AID) system or multiple daily insulin injections (MDI) with continuous glucose monitoring. RESEARCH DESIGN AND METHODS At 19 sites, adults with type 1 diabetes were randomly assigned to TI plus insulin degludec (N = 62) or usual care (UC) with continuation of prestudy insulin delivery method (N = 61) for 17 weeks. RESULTS Prestudy, AID was used by 48% and MDI by 45%. Mean ± SD HbA1c was 7.57% ± 0.97% at baseline and 7.62% ± 1.06% at 17 weeks in the TI group and 7.59% ± 0.80% and 7.54% ± 0.77%, respectively, in the UC group (adjusted difference 0.11%, 95% CI −0.10 to 0.33, P value for noninferiority = 0.01). HbA1c improved from baseline to 17 weeks by >0.5% (5.5 mmol/mol) in 12 (21%) in the TI group and in 3 (5%) in the UC group and worsened by >0.5% (5.5 mmol/mol) in 15 (26%) in the TI group and in 2 (3%) in the UC group. The most common TI side effect was a brief cough; eight participants discontinued TI due to side effects. CONCLUSIONS In adults with type 1 diabetes, HbA1c after 17 weeks with a regimen of TI and degludec was noninferior to UC, which consisted predominately of either AID or MDI. TI should be considered an option for people with type 1 diabetes, particularly those who are motivated to further reduce postprandial hyperglycemia.
A Randomized Comparison of Postprandial Glucose Excursion Using Inhaled Insulin Versus Rapid-Acting Analog Insulin in Adults With Type 1 Diabetes Using Multiple Daily Injections of Insulin or Automated Insulin Delivery
Hirsch, Irl B., Beck, Roy W. , Marak, Martin Chase , Calhoun, Peter , Mottalib, Adham , Salhin, Amna, Manessis, Anastasios , Bhargava, Anuj , Thorsell, Ashley, Atakov-Castillo, Astrid , Bode, Bruce W., Levister, Camilla, Donahue, Cassandra, Cordero, Christian, Beatson, Christie , Langel, Christine R., Jacobson, Christopher , Kurek, Corey, Cruse, Dana, Pickering, David, Tamarez, Denisa, Desjardins, Donna, O’Malley, Grenye , Aktürk, Halis Kaan , Diner, Jamie, Baran, Jesica D., Ruedy, Katrina J., Codorniz, Kevin , Klein, Klara R. , Castorino, Kristin , Jordan, L.F., Kipnes, Mark, Church, Mei Mei , Raskin, Philip, Nguyen, Quang T., Weinstock, Ruth S. , Rizvi, Shafaq, Bzdick, Suzan, Rodriguez, Tahereh Ghorbani, Salah, Tareq , Blevins, Thomas , Kudva, Yogish C. , Haider, Zehra, Group, INHALE-3 Study, Bode, Bruce W., Ownby, Jonathan G., Johnson, Joseph H., Ruiz, Adriana, Stephens, Nashia, Maxson, Amanda, Beatson, Christie, Mason, E E , Steenkamp, Devin W., Wolpert, Howard , Sullivan, Asya, Salhin, Amna, Copple, Tina, Beltran, Stephanie, Ryan, Terri, O’Malley, Grenye, Tamarez, Denisa, Ipek, Aslihan, Burke, Christine, Langel, Christine, Bauman, Shannon , Haight, Cristina, Bohr, A., Badri, Marwa Al, Nguyen, Loida, Cordero, Christian, Migliozzi, Brittney, Reid, Corey, Kaur, Ravinder Jeet , Livingood, Daine, Cruse, Dana, Kravarusic, Jelena, Coyne, Kasey, Herrmann, Stefanie, Fronczyk, Evelyn, McKillop, Lorcan, Hyatt, Jamie, Patruno, Maria, Shuirman, Maggie, Cobb, Brandon, Watt, Olivia, Casaubon, Luis, Espinosa, Valerie, Pandit, Keta, Perez, Jennifer, Armstrong, Chloe, Martinez-Arredondo, Maritza, Stewart, Ana, Rodriguez, Tahereh Ghorbani, Young, Laura , Kass, Alexander, Fulghum, Karla, Jordan, Lin, Shao, Baomei, Baran, Jesica, Mandava, Patali, Holod, Rosanna, Kaiserman, Kevin B. , Ulloa, Johanna, Pleitez, Jennifer, Sylvan, Joey, Badgett, Lynn, Borgman, Sarah, Frey, Sarah, Mba-Oduwusi, Nnenna, Miller, Paige , Fults, Ashleigh, Marak, Martin, Pritchard, Rosa, Dolzhenko, E. N. , Gabrielson, Deanna, Brown, Sue A. , Ahmann, Andrew , Bergenstal, Richard M. , Levy, Carol J , Steenkamp, Devin W , Aleppo, Grazia , Akturk, Halis K , Klein, Klara R , Castorino, Kristin , Church, Mei Mei , Hamdy, Osama , Weinstock, Ruth S , Salah, Tareq , Kudva, Yogish C. , Beck, Roy W , Calhoun, Peter , Coviello, Andrea D. , Bode, Bruce W., Levy, Carol J. , Donahue, Cassandra, Aleppo, Grazia , Buse, John B. , Nguyen, Quang T., Lee, Scott Jeffery , Group, INHALE-3 Study, Bode, Bruce W., Beatson, Christie, Mason, Emma, Steenkamp, Devin W., Salhin, Amna, O’Malley, Grenye, Bauman, Shannon, Dhaver, Shilton , Nguyen, Quang T., Cordero, Christian, Cruse, Dana, Johnson, Olivia, Rodriguez, Tahereh Ghorbani, Miller, Paige, McCarthy, Chris

Diabetes Care | July 23, 2024 | Volume: 47 | Issue: 9 | Pages: 1682-1687

10.2337/dc24-0838 Get It

OBJECTIVE To compare postprandial glucose excursions following a bolus with inhaled technosphere insulin (TI) or subcutaneous rapid-acting analog (RAA) insulin. RESEARCH DESIGN AND METHODS A meal challenge was completed by 122 adults with type 1 diabetes who were using multiple daily injections (MDI), a nonautomated pump, or automated insulin delivery (AID) and who were randomized to bolus with their usual RAA insulin (n = 61) or TI (n = 61). RESULTS The primary outcome, the treatment group difference in area under the curve for glucose >180 mg/dL over 2 h, was less with TI versus RAA (adjusted difference −12 mg/dL, 95% CI −22 to −2, P = 0.02). With TI, the glucose excursion was smaller (P = 0.01), peak glucose lower (P = 0.01), and time to peak glucose shorter (P = 0.006). Blood glucose <70 mg/dL occurred in one participant in each group. CONCLUSIONS Postmeal glucose excursion was smaller with TI than with RAA insulin in a cohort that included both AID and MDI users.
Longitudinal Observation of Insulin Use and Glucose Sensor Metrics in Pregnant Women with Type 1 Diabetes Using Continuous Glucose Monitors and Insulin Pumps: The LOIS-P Study
O’Malley, Grenye , Özaslan, Başak , Levy, Carol J. , Castorino, Kristin , Desjardins, Donna, Levister, Camilla, McCrady-Spitzer, Shelly , Church, Mei Mei , Kaur, Ravinder Jeet , Reid, Corey, Kremers, Walter K. , Trinidad, Mari Charisse, Rosenn, Barak, Pinsker, Jordan E. , Kudva, Yogish C. , Dassau, Eyal , Doyle, Francis J , Pinsker, Jordan E , Kudva, Yogish C. , Dassau, Eyal , Levy, Carol J , Kremers, Walter K , Castorino, Kristin , Doyle, Francis J.

Diabetes Technology & Therapeutics | July 16, 2021 | Volume: 23 | Issue: 12 | Pages: 807-817

10.1089/dia.2021.0112 Get It

Background: Suboptimal glycemic control is associated with maternal and neonatal morbidity and mortality in pregnancy complicated by type 1 diabetes (T1D). Prospective analysis of continuous glucose monitoring (CGM) metrics, insulin pump settings, and insulin delivery can better characterize the changes in glycemic levels and insulin use throughout pregnancy with T1D. Materials and Methods: Prescribed parameters, insulin delivery, carbohydrate intake, and CGM data for 25 pregnant women with T1D from three U.S. sites were collected. Participants enrolled before 17 weeks gestation and used personal insulin pumps and study CGM. Mean daily total, basal, and bolus insulin doses (units/kg), CGM time in range (TIR: 63–140 mg/dL), and pump-entered carbohydrates were analyzed for every 2-week gestational interval. Linear mixed-effects regression models were used to evaluate changes across gestational ages compared to 12–14 weeks. Results: Basal insulin was higher during weeks 6–12 and 24–40. Daily bolus and total insulin were higher during weeks 20–40. Pump parameters were adjusted to intensify insulin therapy from 22 weeks onward. Average TIR across pregnancy was 59% ± 14%. Between 18 and 30 weeks, TIR was significantly lower, and time above range was significantly higher compared to the reference biweek. Time below target was lower between 22 and 34 weeks. Seven participants achieved >70% recommended TIR for pregnancy. Participants with maternal complications or infant neonatal intensive care unit admissions had lower TIR. Conclusion: While insulin dosing changed significantly with advancing gestation, most participants did not achieve >70% TIR. Customized anticipatory pump setting adjustments and automated systems aimed toward the designated TIR are needed to improve outcomes for this population. NCT03761615