Background: Given the faster onset and shorter duration of action of ultra-rapid insulin lispro-aabc (URLi, Lyumjev™ insulin), compared with insulin lispro (a rapid-acting insulin [RAI]), the present study investigated the safety and glycemic outcomes of MiniMed™ 780G advanced hybrid closed-loop (AHCL) use with URLi in youths and adults with T1D. Methods: This 19-site, single-arm, clinical trial enrolled children and adolescents (aged 7–17 years) and adults (aged 18–80 years) with T1D who underwent a run-in period (∼2 weeks) using open loop or automated basal only with an RAI (aspart or lispro), followed by a 3-month study period using URLi with AHCL (AHCL + URLi). End-of-study glycemic metrics and A1c were compared to predefined thresholds and to data from baseline/run-in. Use of recommended optimal settings (ROS, 100 mg/dL glucose target with an active insulin time [AIT] of 2 h) was also assessed. Results: In an intention-to-treat population ( N = 101 pediatric and N = 110 adult participants), percentage of time in range (%TIR) during the last ∼6 weeks of the study period was significantly greater than the predefined thresholds for both the pediatric and adult participants. A1c was unchanged in the pediatric cohort but significantly reduced in the adult cohort (from 7.4 ± 0.9% to 6.9 ± 0.6% [ P < 0.001]). Compared with run-in, study period %TIR and percentage of time in tight target range (%TITR) were significantly increased (pediatric mean %TIRΔ [17.4%] and %TITRΔ [16.0%], respectively, and adult mean %TIRΔ [10.6%] and %TITRΔ [11.6%], respectively; P < 0.001 for all). Additionally, % time above range for both groups was significantly reduced. Use of ROS allowed more participants to achieve recommended glycemic targets. There were no severe hypoglycemia or diabetic ketoacidosis events. Most caregivers agreed that mealtime versus premeal URLi delivery simplified pediatric meal management. Conclusions: Similar to previous studies investigating automated URLi delivery, URLi use in the MiniMed™ 780G system was safe, and glycemic outcomes were favorable for pediatric and adult participants.
A Randomized Trial Comparing Inhaled Insulin Plus Basal Insulin Versus Usual Care in Adults With Type 1 Diabetes
OBJECTIVE To evaluate a regimen of inhaled Technosphere insulin (TI) plus insulin degludec in adults with type 1 diabetes, who prestudy were predominately using either an automated insulin delivery (AID) system or multiple daily insulin injections (MDI) with continuous glucose monitoring. RESEARCH DESIGN AND METHODS At 19 sites, adults with type 1 diabetes were randomly assigned to TI plus insulin degludec (N = 62) or usual care (UC) with continuation of prestudy insulin delivery method (N = 61) for 17 weeks. RESULTS Prestudy, AID was used by 48% and MDI by 45%. Mean ± SD HbA1c was 7.57% ± 0.97% at baseline and 7.62% ± 1.06% at 17 weeks in the TI group and 7.59% ± 0.80% and 7.54% ± 0.77%, respectively, in the UC group (adjusted difference 0.11%, 95% CI −0.10 to 0.33, P value for noninferiority = 0.01). HbA1c improved from baseline to 17 weeks by >0.5% (5.5 mmol/mol) in 12 (21%) in the TI group and in 3 (5%) in the UC group and worsened by >0.5% (5.5 mmol/mol) in 15 (26%) in the TI group and in 2 (3%) in the UC group. The most common TI side effect was a brief cough; eight participants discontinued TI due to side effects. CONCLUSIONS In adults with type 1 diabetes, HbA1c after 17 weeks with a regimen of TI and degludec was noninferior to UC, which consisted predominately of either AID or MDI. TI should be considered an option for people with type 1 diabetes, particularly those who are motivated to further reduce postprandial hyperglycemia.
A Randomized Comparison of Postprandial Glucose Excursion Using Inhaled Insulin Versus Rapid-Acting Analog Insulin in Adults With Type 1 Diabetes Using Multiple Daily Injections of Insulin or Automated Insulin Delivery
OBJECTIVE To compare postprandial glucose excursions following a bolus with inhaled technosphere insulin (TI) or subcutaneous rapid-acting analog (RAA) insulin. RESEARCH DESIGN AND METHODS A meal challenge was completed by 122 adults with type 1 diabetes who were using multiple daily injections (MDI), a nonautomated pump, or automated insulin delivery (AID) and who were randomized to bolus with their usual RAA insulin (n = 61) or TI (n = 61). RESULTS The primary outcome, the treatment group difference in area under the curve for glucose >180 mg/dL over 2 h, was less with TI versus RAA (adjusted difference −12 mg/dL, 95% CI −22 to −2, P = 0.02). With TI, the glucose excursion was smaller (P = 0.01), peak glucose lower (P = 0.01), and time to peak glucose shorter (P = 0.006). Blood glucose <70 mg/dL occurred in one participant in each group. CONCLUSIONS Postmeal glucose excursion was smaller with TI than with RAA insulin in a cohort that included both AID and MDI users.
Approach to Using Trend Arrows in the FreeStyle Libre Flash Glucose Monitoring Systems in Adults
Response to Comment on Lachin et al. Association of Glycemic Variability in Type 1 Diabetes With Progression of Microvascular Outcomes in the Diabetes Control and Complications Trial. Diabetes Care 2017;40:777–783
OBJECTIVE The Diabetes Control and Complications Trial (DCCT) demonstrated the beneficial effects of intensive versus conventional therapy on the development and progression of microvascular complications of type 1 diabetes. These beneficial effects were almost completely explained by the difference between groups in the levels of HbA1c, which in turn were associated with the risk of these complications. We assessed the association of glucose variability within and between quarterly 7-point glucose profiles with the development and progression of retinopathy, nephropathy, and cardiovascular autonomic neuropathy during the DCCT. RESEARCH DESIGN AND METHODS Measures of variability included the within-day and updated mean (over time) of the SD, mean amplitude of glycemic excursions (MAGE), and M-value, and the longitudinal within-day, between-day, and total variances. Imputation methods filled in the 16.3% of expected glucose values that were missing. RESULTS Cox proportional hazards models assessed the association of each measure of glycemic variation, as a time-dependent covariate, with the risk of retinopathy and nephropathy, and a longitudinal logistic regression model did likewise for cardiovascular autonomic neuropathy. Adjusted for mean blood glucose, no measure of within-day variability was associated with any outcome. Only the longitudinal mean M-value (over time) was significantly associated with microalbuminuria when adjusted for the longitudinal mean blood glucose and corrected for multiple tests using the Holm procedure. CONCLUSIONS Overall, within-day glycemic variability, as determined from quarterly glucose profiles, does not play an apparent role in the development of microvascular complications beyond the influence of the mean glucose.
Observations on C-Peptide and Free Insulin in the Blood During Continuous Subcutaneous Insulin Infusion and Conventional Insulin Therapy
As part of a multicenter trial, 70 individuals with insulin-dependent diabetes were randomized to either conventional insulin therapy (CIT) or continuous subcutaneous insulin infusion (CSII). In order to standardize patient selection in the six participating centers, one of the eligibility criteria was the demonstration that each patient had no residual endogenous insulin secretion as assessed by plasma C-peptide determinations. The patients were of average (± SEM) age of 33.0 ± 1.6 yr, had had diabetes for a mean (±SEM) duration of 17.4 ± 1.1 yr, and had both fasting and postglucagon stimulation C-peptide values of <0.1 pmol/ml, consistent with clinically insignificant endogenous insulin secretion. There was no change in C-peptide response at 4 or 8 mo compared with baseline values, whether or not the patient's glucose control remained unchanged (CIT group) or significantly improved to near-normoglycemia (CSII group). In a subgroup of 34 patients at three centers, the 24-h mean glucose concentration was significantly lower in the CSII group compared with the CIT group at 4 mo (126 ± 10 versus 176 ± 14 mg/dl) and at 8 mo (121 ± 5 versus 183 ± 15 mg/dl) (P < 0.005). Although the 24-h mean serum free immunoreactive insulin levels were shown to be no different at baseline (27.4 ± 3.8 versus 26.2 ± 3.1 μU/ml) or after 4 mo (22.5 ± 3.2 versus 25.6 ± 3.2) or 8 mo (26.5 ± 3.4 versus 28.8 ± 3.4) of CIT or CSII therapy, respectively, the mean increase of free insulin concentrations in relation to the main meals was greater in the CSII group (P < 0.05). The mean serum free insulin levels achieved with both CIT and CSII were significantly greater than the 24-h mean free insulin level obtained in 12 normal subjects (12.2 ± 1.4 μU/ml) (P < 0.001).