Background: Given the faster onset and shorter duration of action of ultra-rapid insulin lispro-aabc (URLi, Lyumjev™ insulin), compared with insulin lispro (a rapid-acting insulin [RAI]), the present study investigated the safety and glycemic outcomes of MiniMed™ 780G advanced hybrid closed-loop (AHCL) use with URLi in youths and adults with T1D. Methods: This 19-site, single-arm, clinical trial enrolled children and adolescents (aged 7–17 years) and adults (aged 18–80 years) with T1D who underwent a run-in period (∼2 weeks) using open loop or automated basal only with an RAI (aspart or lispro), followed by a 3-month study period using URLi with AHCL (AHCL + URLi). End-of-study glycemic metrics and A1c were compared to predefined thresholds and to data from baseline/run-in. Use of recommended optimal settings (ROS, 100 mg/dL glucose target with an active insulin time [AIT] of 2 h) was also assessed. Results: In an intention-to-treat population ( N = 101 pediatric and N = 110 adult participants), percentage of time in range (%TIR) during the last ∼6 weeks of the study period was significantly greater than the predefined thresholds for both the pediatric and adult participants. A1c was unchanged in the pediatric cohort but significantly reduced in the adult cohort (from 7.4 ± 0.9% to 6.9 ± 0.6% [ P < 0.001]). Compared with run-in, study period %TIR and percentage of time in tight target range (%TITR) were significantly increased (pediatric mean %TIRΔ [17.4%] and %TITRΔ [16.0%], respectively, and adult mean %TIRΔ [10.6%] and %TITRΔ [11.6%], respectively; P < 0.001 for all). Additionally, % time above range for both groups was significantly reduced. Use of ROS allowed more participants to achieve recommended glycemic targets. There were no severe hypoglycemia or diabetic ketoacidosis events. Most caregivers agreed that mealtime versus premeal URLi delivery simplified pediatric meal management. Conclusions: Similar to previous studies investigating automated URLi delivery, URLi use in the MiniMed™ 780G system was safe, and glycemic outcomes were favorable for pediatric and adult participants.
A Randomized Trial Comparing Inhaled Insulin Plus Basal Insulin Versus Usual Care in Adults With Type 1 Diabetes
OBJECTIVE To evaluate a regimen of inhaled Technosphere insulin (TI) plus insulin degludec in adults with type 1 diabetes, who prestudy were predominately using either an automated insulin delivery (AID) system or multiple daily insulin injections (MDI) with continuous glucose monitoring. RESEARCH DESIGN AND METHODS At 19 sites, adults with type 1 diabetes were randomly assigned to TI plus insulin degludec (N = 62) or usual care (UC) with continuation of prestudy insulin delivery method (N = 61) for 17 weeks. RESULTS Prestudy, AID was used by 48% and MDI by 45%. Mean ± SD HbA1c was 7.57% ± 0.97% at baseline and 7.62% ± 1.06% at 17 weeks in the TI group and 7.59% ± 0.80% and 7.54% ± 0.77%, respectively, in the UC group (adjusted difference 0.11%, 95% CI −0.10 to 0.33, P value for noninferiority = 0.01). HbA1c improved from baseline to 17 weeks by >0.5% (5.5 mmol/mol) in 12 (21%) in the TI group and in 3 (5%) in the UC group and worsened by >0.5% (5.5 mmol/mol) in 15 (26%) in the TI group and in 2 (3%) in the UC group. The most common TI side effect was a brief cough; eight participants discontinued TI due to side effects. CONCLUSIONS In adults with type 1 diabetes, HbA1c after 17 weeks with a regimen of TI and degludec was noninferior to UC, which consisted predominately of either AID or MDI. TI should be considered an option for people with type 1 diabetes, particularly those who are motivated to further reduce postprandial hyperglycemia.
Improved Glycemia with Hybrid Closed-Loop Versus Continuous Subcutaneous Insulin Infusion Therapy: Results from a Randomized Controlled Trial
Objective: To evaluate glycemic outcomes in the Wireless Innovation for Seniors with Diabetes Mellitus (WISDM) randomized clinical trial (RCT) participants during an observational extension phase. Research Design and Methods: WISDM RCT was a 26-week RCT comparing continuous glucose monitoring (CGM) with blood glucose monitoring (BGM) in 203 adults aged ≥60 years with type 1 diabetes. Of the 198 participants who completed the RCT, 100 (98%) CGM group participants continued CGM (CGM-CGM cohort) and 94 (98%) BGM group participants initiated CGM (BGM-CGM cohort) for an additional 26 weeks. Results: CGM was used a median of >90% of the time at 52 weeks in both cohorts. In the CGM-CGM cohort, median time <70 mg/dL decreased from 5.0% at baseline to 2.6% at 26 weeks and remained stable with a median of 2.8% at 52 weeks ( P < 0.001 baseline to 52 weeks). Participants spent more time in range 70–180 mg/dL (TIR) (mean 56% vs. 64%; P < 0.001) and had lower hemoglobin A1c (HbA1c) (mean 7.6% [59 mmol/mol] vs. 7.4% [57 mmol/mol]; P = 0.01) from baseline to 52 weeks. In BGM-CGM, from 26 to 52 weeks median time <70 mg/dL decreased from 3.9% to 1.9% ( P < 0.001), TIR increased from 56% to 60% ( P = 0.006) and HbA1c decreased from 7.5% (58 mmol/mol) to 7.3% (57 mmol/mol) ( P = 0.025). In BGM-CGM, a severe hypoglycemic event was reported for nine participants while using BGM during the RCT and for two participants during the extension phase with CGM ( P = 0.02). Conclusions: CGM use reduced hypoglycemia without increasing hyperglycemia in older adults with type 1 diabetes. These data provide further evidence for fully integrating CGM into clinical practice. Clinicaltrials.gov (NCT03240432)
Evaluation of Extended Infusion Set Performance in Adults with Type 1 Diabetes: Infusion Set Survival Rate and Glycemic Outcomes from a Pivotal Trial
Background: Standard insulin infusion sets (IISs) are to be replaced every 2 to 3 days to avoid complications and diabetic ketosis due to set failure. This pivotal trial evaluated the safety and performance of a new extended-wear infusion set (EIS) when used for 7 days by adults with type 1 diabetes (T1D). Methods: This single-arm, nonrandomized trial enrolled adults (18–80 years of age) with T1D, who used their own MiniMed™ 670G system with insulin lispro or insulin aspart and the EIS for up to 7 days, across 12 consecutive wears. Safety endpoints included incidence of serious adverse events (SAEs), serious adverse device effects (SADEs), unanticipated adverse device effects (UADEs), severe hypoglycemia (SevHypo), severe hyperglycemia (SevHyper), diabetic ketoacidosis (DKA), and skin infection. The EIS failure rate due to unexplained hyperglycemia (i.e., suspected occlusion), the overall EIS survival rate, glycemic control outcomes (i.e., A1C, mean sensor glucose and time spent in established glucose ranges), total daily insulin delivered, and satisfaction with the EIS were determined. Results: The intention to treat population ( n = 259, 48% men, 45.0 ± 14.1 years) wore a total of 3041 EIS devices. No SADE, UADE, or DKA events was reported. Overall rates of SAEs, SevHypo, SevHyper, and skin infection were 3.8, 2.5, 104.1, and 20.1 events per 100 participant-years. The rate of EIS failure due to unexplained hyperglycemia at the end of day 7 was 0.1% (95% confidence interval [CI]: 0.03–0.51) and 0.4% (95% CI: 0.16–1.00) for insulin lispro and aspart use, respectively. Overall EIS survival rate at the end of day 7 was 77.8% (95% CI: 76.2–79.3), glycemic control did not change, and participants reported greater satisfaction with the EIS compared with standard IISs worn before the study ( P < 0.001). Conclusions: This investigation demonstrates that the EIS, when worn for up to 7 days, was safe and rated with high satisfaction, without adversely affecting glycemic control in adults with T1D. Clinical Trial Registration number: NCT04113694 ( https://clinicaltrials.gov/ct2/show/NCT04113694 ).
Effect of Continuous Glucose Monitoring on Hypoglycemia in Older Adults With Type 1 Diabetes