Back to Authors

Shin, John

https://orcid.org/0000-0001-7831-8404

Mayo Clinic

Medtronic Diabetes, Northridge, California, USA

Citations 4

Safety and Effectiveness of MiniMed™ 780G Advanced Hybrid Closed-Loop Use with Ultrarapid Insulin Lispro-AABC in Pediatric and Adult Type 1 Diabetes
Akturk, Halis K, Nally, Laura M, Lal, Rayhan A, Warren, Mark , Demeterco-Berggren, Carla, Forlenza, Gregory P. , Reed, John Chip, Shulman, Dorothy I, Kipnes, Mark S, Bode, Bruce W. , Dewan, Asheesh K., Liljenquist, David R., Kudva, Yogish C, Niu, Fang , Yovanovich, Caroline, Shin, John , Cordero, Toni L. , McVean, Jennifer J F, Bergenstal, Richard M, Forlenza, Gregory P , Aktürk, Halis Kaan , Nally, Laura Marie , Lal, Rayhan , Demeterco‐Berggren, Carla , Reed, John H. Chip, Shulman, Dorothy I. , Kipnes, Mark, Kudva, Yogish C. , MCVEAN, JENNIFER J.F. , Vigersky, Robert A. , Bergenstal, Richard M.

Diabetes Technology & Therapeutics | April 29, 2026 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.1177/15209156261444994 Get It

Background: Given the faster onset and shorter duration of action of ultra-rapid insulin lispro-aabc (URLi, Lyumjev™ insulin), compared with insulin lispro (a rapid-acting insulin [RAI]), the present study investigated the safety and glycemic outcomes of MiniMed™ 780G advanced hybrid closed-loop (AHCL) use with URLi in youths and adults with T1D. Methods: This 19-site, single-arm, clinical trial enrolled children and adolescents (aged 7–17 years) and adults (aged 18–80 years) with T1D who underwent a run-in period (∼2 weeks) using open loop or automated basal only with an RAI (aspart or lispro), followed by a 3-month study period using URLi with AHCL (AHCL + URLi). End-of-study glycemic metrics and A1c were compared to predefined thresholds and to data from baseline/run-in. Use of recommended optimal settings (ROS, 100 mg/dL glucose target with an active insulin time [AIT] of 2 h) was also assessed. Results: In an intention-to-treat population ( N = 101 pediatric and N = 110 adult participants), percentage of time in range (%TIR) during the last ∼6 weeks of the study period was significantly greater than the predefined thresholds for both the pediatric and adult participants. A1c was unchanged in the pediatric cohort but significantly reduced in the adult cohort (from 7.4 ± 0.9% to 6.9 ± 0.6% [ P < 0.001]). Compared with run-in, study period %TIR and percentage of time in tight target range (%TITR) were significantly increased (pediatric mean %TIRΔ [17.4%] and %TITRΔ [16.0%], respectively, and adult mean %TIRΔ [10.6%] and %TITRΔ [11.6%], respectively; P < 0.001 for all). Additionally, % time above range for both groups was significantly reduced. Use of ROS allowed more participants to achieve recommended glycemic targets. There were no severe hypoglycemia or diabetic ketoacidosis events. Most caregivers agreed that mealtime versus premeal URLi delivery simplified pediatric meal management. Conclusions: Similar to previous studies investigating automated URLi delivery, URLi use in the MiniMed™ 780G system was safe, and glycemic outcomes were favorable for pediatric and adult participants.
Improved Glycemia with Hybrid Closed-Loop Versus Continuous Subcutaneous Insulin Infusion Therapy: Results from a Randomized Controlled Trial
Grunberger, George , Weinstock, Ruth S. , Hirsch, Irl B. , DiMeglio, Linda A. , Philis‐Tsimikas, Athena , Kipnes, Mark, Liljenquist, David R., Brazg, Ronald, Kudva, Yogish C. , Buckingham, Bruce A. , Carlson, Anders L. , Criego, Amy , Christiansen, Mark P., Kaiserman, Kevin B. , Forlenza, Gregory P. , Bode, Bruce W. , Slover, Robert H., Keiter, Ashleigh , Ling, Chenxiao , Marinos, Briggitte, Cordero, Toni L. , Shin, John , Lee, Scott W., Rhinehart, Andrew S., Group, for the Adult and Pediatric MiniMed™ HCL Outcomes 6-month RCT: HCL versus CSII Control Study, Downs, Ashleigh, Lange, Samantha , Jost, Emily , KARAMI, ANGELA J., Hamill, Donna, Simha, Vinaya , Desjardins, Donna, Spitzer, Shelly McCrady, Reid, Corey, Kaur, Ravinderjeet, Malone, Halvorson, Mary, Ekhlaspour, Laya , Weir, Christine, Casaubon, Luis, Ang, Lynn , Plunkett, Cindy, Recklein, Carol, Clifton, Mary Jane, Weinstock, Ruth S , Hirsch, Irl B , Kudva, Yogish C. , McGill, Janet B. , Forlenza, Gregory P , Cordero, Toni L , Vigersky, Robert A , Philis-Tsimikas, Athena , Buckingham, Bruce , DiMeglio, Linda , Garg, Satish K. , Lawson, Margaret L. , Pop‐Busui, Rodica , Griffin, Kurt , Vigersky, Robert A. , Group, for the Adult and Pediatric MiniMed™ HCL Outcomes 6-month RCT: HCL versus CSII Control Study, Kaur, Ravinder Jeet , Malone, Stout, Kara Mizokami , Plunkett, Cindy, Williams, Brittany

Diabetes Technology & Therapeutics | December 6, 2022 | Volume: 25 | Issue: 1 | Pages: 1-12

10.1089/dia.2022.0421 Get It

Evaluation of Extended Infusion Set Performance in Adults with Type 1 Diabetes: Infusion Set Survival Rate and Glycemic Outcomes from a Pivotal Trial
Brazg, Ron, Bhargava, Anuj , Thrasher, James, Latif, Kashif, Bode, Bruce W. , Bailey, Timothy S. , Horowitz, Barry , Cavale, Arvind R., Kudva, Yogish C. , Kaiserman, Kevin B. , Grunberger, George , Reed, John Chip, CHATTARAJ, SARNATH , ZHANG, GINA , Shin, John , Chen, Vivian , Lee, Scott W., Cordero, Toni L. , Rhinehart, Andrew S., Buckingham, Bruce A. , Bailey, Timothy S , Horowitz, Barry S , Kudva, Yogish C. , Cordero, Toni L , Vigersky, Robert A , Buckingham, Bruce , Garg, Satish K. , Reed, John H. Chip, Vigersky, Robert A.

Diabetes Technology & Therapeutics | March 9, 2022 | Volume: 24 | Issue: 8 | Pages: 535-543

10.1089/dia.2021.0540 Get It

Background: Standard insulin infusion sets (IISs) are to be replaced every 2 to 3 days to avoid complications and diabetic ketosis due to set failure. This pivotal trial evaluated the safety and performance of a new extended-wear infusion set (EIS) when used for 7 days by adults with type 1 diabetes (T1D). Methods: This single-arm, nonrandomized trial enrolled adults (18–80 years of age) with T1D, who used their own MiniMed™ 670G system with insulin lispro or insulin aspart and the EIS for up to 7 days, across 12 consecutive wears. Safety endpoints included incidence of serious adverse events (SAEs), serious adverse device effects (SADEs), unanticipated adverse device effects (UADEs), severe hypoglycemia (SevHypo), severe hyperglycemia (SevHyper), diabetic ketoacidosis (DKA), and skin infection. The EIS failure rate due to unexplained hyperglycemia (i.e., suspected occlusion), the overall EIS survival rate, glycemic control outcomes (i.e., A1C, mean sensor glucose and time spent in established glucose ranges), total daily insulin delivered, and satisfaction with the EIS were determined. Results: The intention to treat population ( n = 259, 48% men, 45.0 ± 14.1 years) wore a total of 3041 EIS devices. No SADE, UADE, or DKA events was reported. Overall rates of SAEs, SevHypo, SevHyper, and skin infection were 3.8, 2.5, 104.1, and 20.1 events per 100 participant-years. The rate of EIS failure due to unexplained hyperglycemia at the end of day 7 was 0.1% (95% confidence interval [CI]: 0.03–0.51) and 0.4% (95% CI: 0.16–1.00) for insulin lispro and aspart use, respectively. Overall EIS survival rate at the end of day 7 was 77.8% (95% CI: 76.2–79.3), glycemic control did not change, and participants reported greater satisfaction with the EIS compared with standard IISs worn before the study ( P < 0.001). Conclusions: This investigation demonstrates that the EIS, when worn for up to 7 days, was safe and rated with high satisfaction, without adversely affecting glycemic control in adults with T1D. Clinical Trial Registration number: NCT04113694 ( https://clinicaltrials.gov/ct2/show/NCT04113694 ).
Effects of Sensor-Augmented Pump Therapy on Glycemic Variability in Well-Controlled Type 1 Diabetes in the STAR 3 Study
Buse, John B. , Kudva, Yogish C. , Battelino, Tadej , Davis, Stephen N. , Shin, John , Welsh, John B. , Battelino, Tadej , Buse, John B

Diabetes Technology & Therapeutics | April 23, 2012 | Volume: 14 | Issue: 7 | Pages: 644-647

10.1089/dia.2011.0294 Get It

Background: Compared with multiple daily injections (MDI), sensor-augmented pump (SAP) insulin therapy may reduce glycemic variability and oxidative stress in type 1 diabetes in a glycosylated hemoglobin (A1C)-independent manner. Subjects and Methods: The STAR 3 study compared SAP with MDI therapy for 1 year. Week-long continuous glucose monitoring studies were conducted at baseline and 1 year for assessment of glycemic variability in both groups. Soluble CD40 ligand (CD40L), a biomarker of inflammation and thrombocyte function, was measured at baseline and 1 year. Subjects were classified according to treatment group and 1-year A1C levels (<6.5%, 6.5–6.9%, 7–7.9%, ≥8%). Glycemic parameters were compared between SAP and MDI subjects in each A1C cohort. Results: At 1 year, sensor glucose values at A1C levels ≥6.5% were similar in the SAP and MDI groups. However, sensor glucose SD and coefficient of variation (CV) values were lower at A1C levels <8% among SAP than among MDI subjects; the overall between-group difference was significant for both SD ( P <0.01) and CV ( P =0.01). The overall mean amplitude of glycemic excursion was similar in MDI and SAP groups ( P =0.23). CD40L levels fell over the course of the study in both groups, but the between-group difference was not significant ( P =0.18). CD40L concentrations were unrelated to A1C, change in A1C from baseline, or glycemic variability. Conclusions: At comparable A1C levels of <8%, SAP reduced glycemic variability as measured by SD and CV compared with MDI. SAP may provide beneficial reductions in the number and severity of glycemic excursions.