OBJECTIVE The Centers for Medicare & Medicaid Services (CMS) requires a low C-peptide level for insulin pump coverage unless the individual is β-cell autoantibody positive, which precludes coverage of automated insulin delivery (AID) systems for many people with type 2 diabetes. RESEARCH DESIGN AND METHODS In the Randomized Trial Evaluating the Efficacy and Safety of Control-IQ+ Technology in Adults With Type 2 Diabetes Using Basal-Bolus Insulin Therapy study evaluating the t:slim X2 insulin pump with Control-IQ+ technology, adults with insulin-treated type 2 diabetes were categorized into high C-peptide (n = 195) and low C-peptide (n = 59) groups based on CMS criteria. RESULTS In the AID group, mean HbA1c decreased from baseline by 0.8%, which was significantly greater than in the control group with both high (P < 0.001) and low (P = 0.02) C-peptide levels. Results were similar in participants ≥65 years old. CONCLUSIONS The benefit of AID is present with high and low C-peptide levels. Thus, requiring a low C-peptide level as a prerequisite for AID therapy is not warranted.
Inadequately Controlled Type 2 Diabetes and Hypercortisolism: Improved Glycemia With Mifepristone Treatment
OBJECTIVE In many individuals, type 2 diabetes (T2D) remains poorly controlled despite taking multiple glucose-lowering therapies. Several studies have demonstrated that endogenous hypercortisolism is prevalent among these individuals. We tested whether cortisol-directed therapy improves their glycemic control. RESEARCH DESIGN AND METHODS In this prospective, multicenter, double-blind study, 136 individuals with T2D (hemoglobin A1c [HbA1c] 7.5%–11.5% [58–102 mmol/mol] on multiple medications) and hypercortisolism (by dexamethasone suppression test) were randomized 2:1 to the glucocorticoid receptor antagonist mifepristone (300–900 mg once daily; n = 91) or placebo (n = 45) for 24 weeks, with stratification by presence/absence of an adrenal imaging abnormality. The primary end point was the change in HbA1c. Secondary end points included changes in glucose-lowering medications, weight, and waist circumference and safety. RESULTS Mean baseline HbA1c in the study cohort was 8.55% (69.9 mmol/mol). At 24 weeks, the least squares mean (LSM) difference from placebo in HbA1c was −1.32% (95% CI −1.81 to −0.83; P < 0.001). Participants receiving mifepristone experienced reductions in body weight and waist circumference (placebo-adjusted LSM differences of −5.12 kg [95% CI −8.20 to −2.03] and −5.1 cm [−8.23 to −1.99], respectively). Of participants on mifepristone, 46% discontinued therapy, compared with 18% on placebo. Adverse events with mifepristone (>10% of participants) included hypokalemia, fatigue, nausea, vomiting, headache, peripheral edema, diarrhea, and dizziness, consistent with mifepristone’s known tolerability profile. Increases in blood pressure also occurred. CONCLUSIONS In individuals with inadequately controlled T2D and hypercortisolism, cortisol-directed medical therapy with mifepristone reduced HbA1c, with a manageable tolerability profile.
Prevalence of Hypercortisolism in Difficult-to-Control Type 2 Diabetes
OBJECTIVE Despite the use of multiple glucose-lowering medications, glycemic targets are not met in a significant fraction of people with type 2 diabetes. In this prospective, observational study we assessed the prevalence of hypercortisolism, a potential contributing factor to inadequate glucose control. RESEARCH DESIGN AND METHODS Individuals with type 2 diabetes and HbA1c 7.5%–11.5% (58–102 mmol/mol) on two or more glucose-lowering medications with or without micro-/macrovascular complications or taking multiple blood pressure–lowering medications were screened with a 1-mg dexamethasone suppression test. Common causes of false-positive DSTs were excluded. The primary end point was the prevalence of hypercortisolism, defined as post-DST cortisol >1.8 μg/dL (50 nmol/L). Characteristics associated with hypercortisolism were assessed with multiple logistic regression. The percentage and characteristics of participants with hypercortisolism and adrenal imaging abnormalities were also assessed. RESULTS Post-DST cortisol was unsuppressed in 252 of 1,057 participants (prevalence 23.8%; 95% CI 21.3, 26.5). Hypercortisolism prevalence was 33.3% among participants with cardiac disorders and 36.6% among those taking three or more blood pressure–lowering medications. Adrenal imaging abnormalities were reported in 34.7% of participants with hypercortisolism. Use of sodium–glucose cotransporter 2 inhibitors (odds ratio 1.558), maximum-dose glucagon-like peptide 1 receptor agonists (1.544), tirzepatide (1.981), or a higher number of blood pressure–lowering medications (1.390); older age (1.316); BMI <30 kg/m2 (1.639); non-Latino/Hispanic ethnicity (3.718); and use of fibrates (2.676) or analgesics (1.457) were associated with higher prevalence (all P < 0.03). CONCLUSIONS Hypercortisolism was associated with hyperglycemia in approximately one-quarter of individuals with inadequately controlled type 2 diabetes despite multiple medications.
A Randomized Trial of Automated Insulin Delivery in Type 2 Diabetes
OBJECTIVE To evaluate a regimen of inhaled Technosphere insulin (TI) plus insulin degludec in adults with type 1 diabetes, who prestudy were predominately using either an automated insulin delivery (AID) system or multiple daily insulin injections (MDI) with continuous glucose monitoring. RESEARCH DESIGN AND METHODS At 19 sites, adults with type 1 diabetes were randomly assigned to TI plus insulin degludec (N = 62) or usual care (UC) with continuation of prestudy insulin delivery method (N = 61) for 17 weeks. RESULTS Prestudy, AID was used by 48% and MDI by 45%. Mean ± SD HbA1c was 7.57% ± 0.97% at baseline and 7.62% ± 1.06% at 17 weeks in the TI group and 7.59% ± 0.80% and 7.54% ± 0.77%, respectively, in the UC group (adjusted difference 0.11%, 95% CI −0.10 to 0.33, P value for noninferiority = 0.01). HbA1c improved from baseline to 17 weeks by >0.5% (5.5 mmol/mol) in 12 (21%) in the TI group and in 3 (5%) in the UC group and worsened by >0.5% (5.5 mmol/mol) in 15 (26%) in the TI group and in 2 (3%) in the UC group. The most common TI side effect was a brief cough; eight participants discontinued TI due to side effects. CONCLUSIONS In adults with type 1 diabetes, HbA1c after 17 weeks with a regimen of TI and degludec was noninferior to UC, which consisted predominately of either AID or MDI. TI should be considered an option for people with type 1 diabetes, particularly those who are motivated to further reduce postprandial hyperglycemia.
A Randomized Comparison of Postprandial Glucose Excursion Using Inhaled Insulin Versus Rapid-Acting Analog Insulin in Adults With Type 1 Diabetes Using Multiple Daily Injections of Insulin or Automated Insulin Delivery
OBJECTIVE To compare postprandial glucose excursions following a bolus with inhaled technosphere insulin (TI) or subcutaneous rapid-acting analog (RAA) insulin. RESEARCH DESIGN AND METHODS A meal challenge was completed by 122 adults with type 1 diabetes who were using multiple daily injections (MDI), a nonautomated pump, or automated insulin delivery (AID) and who were randomized to bolus with their usual RAA insulin (n = 61) or TI (n = 61). RESULTS The primary outcome, the treatment group difference in area under the curve for glucose >180 mg/dL over 2 h, was less with TI versus RAA (adjusted difference −12 mg/dL, 95% CI −22 to −2, P = 0.02). With TI, the glucose excursion was smaller (P = 0.01), peak glucose lower (P = 0.01), and time to peak glucose shorter (P = 0.006). Blood glucose <70 mg/dL occurred in one participant in each group. CONCLUSIONS Postmeal glucose excursion was smaller with TI than with RAA insulin in a cohort that included both AID and MDI users.
Benefit of Continuous Glucose Monitoring in Reducing Hypoglycemia Is Sustained Through 12 Months of Use Among Older Adults with Type 1 Diabetes
Objective: To evaluate glycemic outcomes in the Wireless Innovation for Seniors with Diabetes Mellitus (WISDM) randomized clinical trial (RCT) participants during an observational extension phase. Research Design and Methods: WISDM RCT was a 26-week RCT comparing continuous glucose monitoring (CGM) with blood glucose monitoring (BGM) in 203 adults aged ≥60 years with type 1 diabetes. Of the 198 participants who completed the RCT, 100 (98%) CGM group participants continued CGM (CGM-CGM cohort) and 94 (98%) BGM group participants initiated CGM (BGM-CGM cohort) for an additional 26 weeks. Results: CGM was used a median of >90% of the time at 52 weeks in both cohorts. In the CGM-CGM cohort, median time <70 mg/dL decreased from 5.0% at baseline to 2.6% at 26 weeks and remained stable with a median of 2.8% at 52 weeks ( P < 0.001 baseline to 52 weeks). Participants spent more time in range 70–180 mg/dL (TIR) (mean 56% vs. 64%; P < 0.001) and had lower hemoglobin A1c (HbA1c) (mean 7.6% [59 mmol/mol] vs. 7.4% [57 mmol/mol]; P = 0.01) from baseline to 52 weeks. In BGM-CGM, from 26 to 52 weeks median time <70 mg/dL decreased from 3.9% to 1.9% ( P < 0.001), TIR increased from 56% to 60% ( P = 0.006) and HbA1c decreased from 7.5% (58 mmol/mol) to 7.3% (57 mmol/mol) ( P = 0.025). In BGM-CGM, a severe hypoglycemic event was reported for nine participants while using BGM during the RCT and for two participants during the extension phase with CGM ( P = 0.02). Conclusions: CGM use reduced hypoglycemia without increasing hyperglycemia in older adults with type 1 diabetes. These data provide further evidence for fully integrating CGM into clinical practice. Clinicaltrials.gov (NCT03240432)
Effect of Continuous Glucose Monitoring on Hypoglycemia in Older Adults With Type 1 Diabetes
Background: Knowledge regarding the burden and predictors of hypoglycemia among older adults with type 1 diabetes (T1D) is limited. Methods: We analyzed baseline data from the Wireless Innovations for Seniors with Diabetes Mellitus (WISDM) study, which enrolled participants at 22 sites in the United States. Eligibility included clinical diagnosis of T1D, age ≥60 years, no real-time continuous glucose monitoring (CGM) use in prior three months, and HbA1c <10.0%. Blinded CGM data from 203 participants with at least 240 hours were included in the analyses. Results: Median age of the cohort was 68 years (52% female, 93% non-Hispanic white, and 53% used insulin pumps). Mean HbA1c was 7.5%. Median time spent in the glucose range <70 mg/dL was 5.0% (72 min/day) and <54 mg/dL was 1.6% (24 min/day). Among all factors analyzed, only reduced hypoglycemia awareness was associated with greater time spent <54 mg/dL (median time of 2.7% vs 1.3% [39 vs 19 minutes per day] for reduced awareness vs aware/uncertain, respectively, P = .03). Participants spent a mean 56% of total time in target glucose range of 70-180 mg/dL and 37% of time above 180 mg/dL. Conclusions: Over half of older T1D participants spent at least an hour a day with glucose levels <70 mg/dL. Those with reduced hypoglycemia awareness spent over twice as much time than those without in a serious hypoglycemia range (glucose levels <54 mg/dL). Interventions to reduce exposure to clinically significant hypoglycemia and increase time in range are urgently needed in this age group.