Back to Authors

Ogyaadu, Selassie

Mayo Clinic

Icahn School of Medicine at Mount Sinai

Citations 13

Automated Insulin Delivery Is Beneficial in Adults With Insulin-Treated Type 2 Diabetes With and Without GAD65 Antibodies
Beck, Roy W. , Hirsch, Irl B., Raghinaru, Dan, Lum, John W. , Pinsker, Jordan E. , Kudva, Yogish C. , Group*, 2IQP Study, Desjardins, Donna, Kurek, Corey, Kaur, Ravinder Jeet , Livingood, Daine, Rizvi, Shafaq , Graham, Timothy E., Terry, Adrienne, Luker, Ryan, Mellenthin, Melanie, Rezac, Stephanie, Liljenquist, David R., Rogers, Justin, Williams, Jonathan, Christensen, Rochelle, Lee, In‐Kyoung, Malone, Joann, Spanakis, Elias K. , Singh, Lakshmi G., Churchill, Jade, Comen, Kathleen, Scott, William H., Davis, Georgia M. , Arroyo, Lizda Guerrero, Oladejo, Omolade , Usman, Sabeena, Ahmann, Andrew , Schmid, Caleb, Dean, Ariel, Branigan, Deborah , Caswell, Brittany, Heyerman, Tess, Tessman, Brian, Vanderheide, Jnh, Dennis, Brittany , Hendricks, Lisa, Reyes-Rodriguez, Clemente, Wolf, Valerie, Coyne, Kasey, Kravarusic, Jelena, Fronczyk, Evelyn, Herrmann, Stefanie, Penn, Samsam C., Blevins, Thomas , Casaubon, Luis, Espinosa, Valerie, Pandit, Keta, Perez, Jennifer, Stewart, Ana, Assir, Courtney, Fields, Cory, Kruger, Davida , Estrada, Kathleen, Jones, J. Kimberly, Mukhashen, Shereen, Corker, Natalie, Hunter, Heather, Layton, Paula, Brown, Sue A. , Afreen, Samina , Dhillon, Jasmeen, Emory, Emma, Fulkerson, David, Fuller, Morgan, Holmes, Viola, Kollar, Laura, Toole, Elyse, Levister, Camilla, O’Malley, Grenye , Ipek, Aslihan, Alabi, Denise, Ellis, Emily, Hassan, Shaziah, Ogyaadu, Selassie, Tamarez, Denisa, Weinstock, Ruth S. , Stone, Sheri , Bzdick, Suzan, Agostini, Lynn, Bulger, Jane , Wolpert, Howard , Atakov-Castillo, Astrid , Sullivan, Asya, Aia, Corinne, Brouillard, Elizabeth, Driscoll, Marsha, Lapier, Heather, Payra, Sherryl, Vancer, Louise, Averkiou, Xenia, Baran, Jesica, Holod, Rosanna, Litvicov, Patrisia, Mandava, Patali, Swinton, Sydney, Khakpour, Dori , Broyles, Frances E. , Marks, Sheryl, Mitchell, Tina, Hairston, Babette, Costello, Reilly, Curtis, Stella, Kamimoto, Jorge Jo, Peleckis, Amy J. , Sultan, Rahaf , Dalton-Bakes, Cornelia, Bourne, Patricia, Haidar, Ahmad, Pasqua, Melissa, Tardio, Vanessa , Moore, Adelyn, Kemp, Gabrielle, Raskin, Philip, Jordan, L.F., Shao, Baomei, DoNguyen, Trang, Meeks, Tram, Phan, Michael , Lesniak, Amanda, Becerra, Mario, Bellini, Natalie J. , Denallo, Erica, Lewis, Claudia , Tribout, Jerry, Tribout, Megan, DiFrancesco, Kathryn, Phillips, Kylie, Raghinaru, Dan, Campos, Tiffany, Morrell, Beth, Oduah, Vanessa, Cardenas-Villamil, Gabriela, Morales, Amanda, Murphy, Carlos, Strayer, Heidi, Spanbauer, Charles , Kollman, Craig, Sasson-Katchalski, Ravid, Piquette, Nicole, Wheatcroft, Alex, WHITE, KIRSTIN N., Carmelo, KC, Janicek, Robert, Gabrielson, Deanna, Mercado, Kevin, Beck, Roy W , Group*, 2IQP Study, Smith, Joshua W. , Christensen, Rochelle, Malone, Joann, Pasquel, Francisco J. , Tajrishi, Farbod Zahedi , Arroyo, Lizda Guerrero, Dean, Ariel, Howard, Matthew, Vander-Heide, Jesse, Ahn, David , Aleppo, Grazia , Fields, Cory, Layton, Paula, Oliveri, Mary Clancy , Levy, Carol J. , Agostini, Lynn, Steenkamp, Devin W , Spaic, Tamara , Liu, Selina , Marks, Sheryl, Mitchell, Tina, Costello, Reilly, Curtis, Stella, Rickels, Michael R. , Bourne, Patricia, Tsoukas, Michael A. , Pasqua, Melissa-Rosina , Moore, Adelyn, Kemp, Gabrielle, Meeks, Tram, Phan, Michael, Hatipoğlu, Betül , Lesniak, Amanda, Howard, Quiana , DiFrancesco, Kathryn, Raghinaru, Dan, Morrell, Beth, Morales, Amanda, Kanapka, Lauren , Le, Van

Diabetes Care | December 5, 2025 | Volume: 49 | Issue: 2 | Pages: e18-e20

10.2337/dc25-2059 Get It

Adults With Type 2 Diabetes Benefit From Automated Insulin Delivery Irrespective of C-Peptide Level
Hirsch, Irl B., Kudva, Yogish C. , Blevins, Thomas , Raghinaru, Dan, Lum, John W. , Kollman, Craig, Pinsker, Jordan E. , Beck, Roy W. , Group*, 2IQP Study, Desjardins, Donna, Kurek, Corey, Kaur, Ravinder Jeet , Livingood, Daine, Rizvi, Shafaq , Graham, Timothy E., Terry, Adrienne, Luker, Ryan, Mellenthin, Melanie, Rezac, Stephanie, Liljenquist, David R., Rogers, Justin, Williams, Jonathan, Christensen, Rochelle, Lee, In‐Kyoung, Malone, Joann, Spanakis, Elias K. , Singh, Lakshmi G., Churchill, Jade, Comen, Kathleen, Scott, William H., Davis, Georgia M. , Arroyo, Lizda Guerrero, Oladejo, Omolade , Usman, Sabeena, Ahmann, Andrew , Schmid, Caleb, Dean, Ariel, Branigan, Deborah , Caswell, Brittany, Heyerman, Tess, Tessman, Brian, Vanderheide, Jnh, Dennis, Brittany , Hendricks, Lisa, Reyes-Rodriguez, Clemente, Wolf, Valerie, Coyne, Kasey, Kravarusic, Jelena, Fronczyk, Evelyn, Herrmann, Stefanie, Penn, Samsam C., Casaubon, Luis, Espinosa, Valerie, Pandit, Keta, Perez, Jennifer, Stewart, Ana, Assir, Courtney, Fields, Cory, Kruger, Davida , Estrada, Kathleen, Jones, J. Kimberly, Mukhashen, Shereen, Corker, Natalie, Hunter, Heather, Layton, Paula, Brown, Sue A. , Afreen, Samina , Dhillon, Jasmeen, Emory, Emma, Fulkerson, David, Fuller, Morgan, Holmes, Viola, Kollar, Laura, Toole, Elyse, Levister, Camilla, O’Malley, Grenye , Ipek, Aslihan, Alabi, Denise, Ellis, Emily, Hassan, Shaziah, Ogyaadu, Selassie, Tamarez, Denisa, Weinstock, Ruth S. , Stone, Sheri , Bzdick, Suzan, Agostini, Lynn, Bulger, Jane , Wolpert, Howard , Atakov-Castillo, Astrid , Sullivan, Asya, Aia, Corinne, Brouillard, Elizabeth, Driscoll, Marsha, Lapier, Heather, Payra, Sherryl, Vancer, Louise, Averkiou, Xenia, Baran, Jesica, Holod, Rosanna, Litvicov, Patrisia, Mandava, Patali, Swinton, Sydney, Khakpour, Dori , Broyles, Frances E. , Marks, Sheryl, Mitchell, Tina, Hairston, Babette, Costello, Reilly, Curtis, Stella, Rickels, Michael R., Kamimoto, Jorge Jo, Peleckis, Amy J. , Sultan, Rahaf , Dalton-Bakes, Cornelia, Bourne, Patricia, Haidar, Ahmad, Pasqua, Melissa, Tardio, Vanessa , Moore, Adelyn, Kemp, Gabrielle, Raskin, Philip, Jordan, L.F., Shao, Baomei, DoNguyen, Trang, Meeks, Tram, Phan, Michael , Lesniak, Amanda, Becerra, Mario, Denallo, Erica, Lewis, Claudia , Tribout, Jerry, Tribout, Megan, DiFrancesco, Kathryn, Phillips, Kylie, Lum, John W., Campos, Tiffany, Morrell, Beth, Oduah, Vanessa, Cardenas-Villamil, Gabriela, Morales, Amanda, Murphy, Carlos, Strayer, Heidi, Spanbauer, Charles , Kollman, Craig, Sasson-Katchalski, Ravid, Piquette, Nicole, Wheatcroft, Alex, WHITE, KIRSTIN N., Carmelo, KC, Janicek, Robert, Gabrielson, Deanna, Mercado, Kevin, Hirsch, Irl B. , Pinsker, Jordan E , Beck, Roy W , Hirsch, Irl B , Ahn, David , Rickels, Michael R. , Group*, 2IQP Study, Smith, Joshua W. , Christensen, Rochelle, Malone, Joann, Pasquel, Francisco J. , Tajrishi, Farbod Zahedi , Arroyo, Lizda Guerrero, Dean, Ariel, Howard, Matthew, Vander-Heide, Jesse, Aleppo, Grazia , Fields, Cory, Layton, Paula, Oliveri, Mary Clancy , Levy, Carol J. , Agostini, Lynn, Steenkamp, Devin W , Spaic, Tamara , Liu, Selina , Marks, Sheryl, Mitchell, Tina, Costello, Reilly, Curtis, Stella, Rickels, Michael R., Bourne, Patricia, Tsoukas, Michael A. , Pasqua, Melissa-Rosina , Moore, Adelyn, Kemp, Gabrielle, Meeks, Tram, Phan, Michael, Hatipoğlu, Betül , Lesniak, Amanda, Bellini, Natalie J. , Howard, Quiana , Lewis, Claudia, DiFrancesco, Kathryn, Lum, John W., Morrell, Beth, Morales, Amanda, Kanapka, Lauren , Kollman, Craig, Le, Hung V.

Diabetes Care | September 15, 2025 | Volume: 48 | Issue: 12 | Pages: 2061-2066

10.2337/dc25-1125 Get It

OBJECTIVE The Centers for Medicare & Medicaid Services (CMS) requires a low C-peptide level for insulin pump coverage unless the individual is β-cell autoantibody positive, which precludes coverage of automated insulin delivery (AID) systems for many people with type 2 diabetes. RESEARCH DESIGN AND METHODS In the Randomized Trial Evaluating the Efficacy and Safety of Control-IQ+ Technology in Adults With Type 2 Diabetes Using Basal-Bolus Insulin Therapy study evaluating the t:slim X2 insulin pump with Control-IQ+ technology, adults with insulin-treated type 2 diabetes were categorized into high C-peptide (n = 195) and low C-peptide (n = 59) groups based on CMS criteria. RESULTS In the AID group, mean HbA1c decreased from baseline by 0.8%, which was significantly greater than in the control group with both high (P < 0.001) and low (P = 0.02) C-peptide levels. Results were similar in participants ≥65 years old. CONCLUSIONS The benefit of AID is present with high and low C-peptide levels. Thus, requiring a low C-peptide level as a prerequisite for AID therapy is not warranted.
Concordance of Blood Glucose and CGM During a Pilot Trial of Automated Insulin Delivery in Type 1 Diabetes Pregnancies
Kaur, Ravinder Jeet , Castorino, Kristin , Wood‐Wentz, Christina M. , Rizvi, Shafaq R., Özaslan, Başak , O’Malley, Grenye , Trinidad, Mari Charisse, Levister, Camilla, Church, Mei Mei , Desjardins, Donna, Ogyaadu, Selassie, Reid, Corey, Bailey, Kent R. , Pinsker, Jordan E. , Dassau, Eyal , Kudva, Yogish C. , Wood-Wentz, Christina M, Kudva, Yogish C. , Levy, Carol J. , Rizvi, Shafaq, Doyle, Francis J.

Journal of the Endocrine Society | April 15, 2024 | Volume: 8 | Issue: 6 | Pages: No page available

10.1210/jendso/bvae071 Get It

Abstract Background Customized and standard automated insulin delivery (AID) systems for use in pregnancies of women with preexisting type 1 diabetes (T1D) are being developed and tested to achieve pregnancy appropriate continuous glucose monitoring (CGM) targets. Guidance on the use of CGM for treatment decisions during pregnancy in the United States is limited. Methods Ten pregnant women with preexisting T1D participated in a trial evaluating at-home use of a pregnancy-specific AID system. Seven-point self-monitoring of blood glucose (SMBG) was compared to the closest sensor glucose (Dexcom G6 CGM) value biweekly to assess safety and reliability based on the 20%/20 mg/dL criteria. Results All participants completed the study with 7 participants satisfying the safety and reliability criteria with a mean absolute relative difference of 10.3%. Three participants did not fulfill the criteria, mainly because the frequency of SMBG did not meet the requirements. Conclusion Dexcom G6 CGM is safe and accurate in the real-world setting for use in pregnant women with preexisting T1D with reduced SMBG testing as part of a pregnancy-specific AID system.
At-Home Use of a Pregnancy-Specific Zone-MPC Closed-Loop System for Pregnancies Complicated by Type 1 Diabetes: A Single-Arm, Observational Multicenter Study
Levy, Carol J. , Kudva, Yogish C. , Özaslan, Başak , Castorino, Kristin , O’Malley, Grenye , Kaur, Ravinder Jeet , Levister, Camilla, Church, Mei Mei , Desjardins, Donna, McCrady-Spitzer, Shelly , Ogyaadu, Selassie, Trinidad, Mari Charisse, Reid, Corey, Rizvi, Shafaq, Kremers, Walter K. , Pinsker, Jordan E. , Dassau, Eyal , Zaniletti, Isabella, Dassau, Eyal , Levy, Carol J , Kremers, Walter K , Deshpande, Sunil , Zaniletti, Isabella , Doyle, Francis J.

Diabetes Care | May 17, 2023 | Volume: 46 | Issue: 7 | Pages: 1425-1431

10.2337/dc23-0173 Get It

OBJECTIVE There are no commercially available hybrid closed-loop insulin delivery systems customized to achieve pregnancy-specific glucose targets in the U.S. This study aimed to evaluate the feasibility and performance of at-home use of a zone model predictive controller–based closed-loop insulin delivery system customized for pregnancies complicated by type 1 diabetes (CLC-P). RESEARCH DESIGN AND METHODS Pregnant women with type 1 diabetes using insulin pumps were enrolled in the second or early third trimester. After study sensor wear collecting run-in data on personal pump therapy and 2 days of supervised training, participants used CLC-P targeting 80–110 mg/dL during the day and 80–100 mg/dL overnight running on an unlocked smartphone at home. Meals and activities were unrestricted throughout the trial. The primary outcome was the continuous glucose monitoring percentage of time in the target range 63–140 mg/dL versus run-in. RESULTS Ten participants (HbA1c 5.8 ± 0.6%) used the system from mean gestational age of 23.7 ± 3.5 weeks. Mean percentage time in range increased 14.1 percentage points, equivalent to 3.4 h per day, compared with run-in (run-in 64.5 ± 16.3% versus CLC-P 78.6 ± 9.2%; P = 0.002). During CLC-P use, there was significant decrease in both time over 140 mg/dL (P = 0.033) and the hypoglycemic ranges of less than 63 mg/dL and 54 mg/dL (P = 0.037 for both). Nine participants exceeded consensus goals of above 70% time in range during CLC-P use. CONCLUSIONS The results show that the extended use of CLC-P at home until delivery is feasible. Larger, randomized studies are needed to further evaluate system efficacy and pregnancy outcomes.
Outpatient Randomized Crossover Comparison of Zone Model Predictive Control Automated Insulin Delivery with Weekly Data Driven Adaptation Versus Sensor-Augmented Pump: Results from the International Diabetes Closed-Loop Trial 4
Pinsker, Jordan E. , Dassau, Eyal , Deshpande, Sunil , Raghinaru, Dan, Buckingham, Bruce A. , Kudva, Yogish C. , Laffel, Lori M. , Church, Mei Mei , Desrochers, Hannah, Ekhlaspour, Laya , Kaur, Ravinder Jeet , Levister, Camilla, Lum, John W. , Kollman, Craig, Ambler-Osborn, Louise, Freiner, Emily , O’Malley, Grenye , Brooks, Danielle , Ogyaadu, Selassie, Plesser, Mitchell, Simha, Vinaya , Desjardins, Donna, McCrady-Spitzer, Shelly , Nolander, Lisa, Hsu, Liana, Passman, Samantha, Campos, Tiffany, Murphy, Carlos, Patibandla, Nandan, Borgman, Sarah, Arreaza-Rubín, Guillermo , Eggerman, Thomas L., Green, Neal, Belle, Steven H., Castle, Jessica R. , Legault, Laurent , Wysham, Carol , Ekhlaspour, Laya , Lum, John , Doyle, Francis J , Buckingham, Bruce , Levy, Carol J. , Shi, Dawei , Kollman, Craig , Doyle, Francis J. , Isganaitis, Elvira , Beck, Roy W. , Green, Jennifer Greif , Willi, Steven Matthew

Diabetes Technology & Therapeutics | May 12, 2022 | Volume: 24 | Issue: 9 | Pages: 635-642

10.1089/dia.2022.0084 Get It

Background: Automated insulin delivery (AID) systems have proven effective in increasing time-in-range during both clinical trials and real-world use. Further improvements in outcomes for single-hormone (insulin only) AID may be limited by suboptimal insulin delivery settings. Methods: Adults (≥18 years of age) with type 1 diabetes were randomized to either sensor-augmented pump (SAP) (inclusive of predictive low-glucose suspend) or adaptive zone model predictive control AID for 13 weeks, then crossed over to the other arm. Each week, the AID insulin delivery settings were sequentially and automatically updated by an adaptation system running on the study phone. Primary outcome was sensor glucose time-in-range 70–180 mg/dL, with noninferiority in percent time below 54 mg/dL as a hierarchical outcome. Results: Thirty-five participants completed the trial (mean age 39 ± 16 years, HbA1c at enrollment 6.9% ± 1.0%). Mean time-in-range 70–180 mg/dL was 66% with SAP versus 69% with AID (mean adjusted difference +2% [95% confidence interval: −1% to +6%], P = 0.22). Median time <70 mg/dL improved from 3.0% with SAP to 1.6% with AID (−1.5% [−2.4% to −0.5%], P = 0.002). The adaptation system decreased initial basal rates by a median of 4% (−8%, 16%) and increased initial carbohydrate ratios by a median of 45% (32%, 59%) after 13 weeks. Conclusions: Automated adaptation of insulin delivery settings with AID use did not significantly improve time-in-range in this very well-controlled population. Additional study and further refinement of the adaptation system are needed, especially in populations with differing degrees of baseline glycemic control, who may show larger benefits from adaptation.
Hypoglycemia in Prospective Multicenter Study of Pregnancies with Pre-Existing Type 1 Diabetes on Sensor-Augmented Pump Therapy: The LOIS-P Study
Kaur, Ravinder Jeet , Özaslan, Başak , Pinsker, Jordan E. , Trinidad, Mari Charisse, O’Malley, Grenye , Desjardins, Donna, Castorino, Kristin , Levister, Camilla, Reid, Corey, McCrady-Spitzer, Shelly , Ogyaadu, Selassie, Church, Mei Mei , Piper, Molly, Kremers, Walter K. , Rosenn, Barak, Dassau, Eyal , Kudva, Yogish C. , Doyle, Francis J , Dassau, Eyal , Kudva, Yogish C. , Kremers, Walter K , Smith, Byron H. , Doyle, Francis J. , Levy, Carol J.

Diabetes Technology & Therapeutics | March 29, 2022 | Volume: 24 | Issue: 8 | Pages: 544-555

10.1089/dia.2021.0479 Get It

Background: Pregnancies in type 1 diabetes are high risk, and data in the United States are limited regarding continuous glucose monitoring (CGM)-based hypoglycemia throughout pregnancy while on sensor-augmented insulin pump therapy. Materials and Methods: Pregnant women with type 1 diabetes in the LOIS-P Study (Longitudinal Observation of Insulin use and glucose Sensor metrics in Pregnant women with type 1 diabetes using continuous glucose monitors and insulin pumps) were enrolled before 17 weeks gestation at three U.S. centers and we used their personal insulin pump and a study Dexcom G6 CGM. We analyzed data of 25 pregnant women for CGM hypoglycemia based on international consensus guidelines for percentage time <63 and 54 mg/dL, hypoglycemic events and prolonged hypoglycemia events for 24-h, daytime, and overnight periods, and severe hypoglycemia (SH) episodes. Results: For a 24-h period, biweekly median percentage of time <63 mg/dL ranged from 0.8% at biweek 4–5 to 3.7% at biweek 14–15 with high variability throughout pregnancy. Median percentage of time <63 and 54 mg/dL was higher overnight than daytime ( P < 0.01). Hypoglycemic events occurred throughout the pregnancy, ranged 1–4 events per 2 weeks, significantly decreased after the 20th week, and occurred predominantly during daytime ( P < 0.01). For overnight period, hypoglycemia and events were more concentrated from 12 to 3 am. Seven prolonged hypoglycemia events without any associated SH occurred in four participants (16%), primarily overnight. Three participants experienced a single episode of SH. Conclusions: Our results suggest a higher overall risk of hypoglycemia throughout pregnancy during the overnight period with continued daytime risk of hypoglycemic events in pregnancies complicated by type 1 diabetes.
Feasibility of Closed-Loop Insulin Delivery with a Pregnancy-Specific Zone Model Predictive Control Algorithm
Özaslan, Başak , Kudva, Yogish C. , Pinsker, Jordan E. , O’Malley, Grenye , Kaur, Ravinder Jeet , Castorino, Kristin , Levister, Camilla, Trinidad, Mari Charisse, Desjardins, Donna, Church, Mei Mei , Plesser, Mitchell, McCrady-Spitzer, Shelly , Ogyaadu, Selassie, Nelson, Kristen L., Reid, Corey, Kremers, Walter K. , Rosenn, Barak, Dassau, Eyal , Kudva, Yogish C. , Doyle, Francis J , Dassau, Eyal , Kremers, Walter K , Levy, Carol J. , Nelson, Kristen, Deshpande, Sunil , Doyle, Francis J.

Diabetes Technology & Therapeutics | March 1, 2022 | Volume: 24 | Issue: 7 | Pages: 471-480

10.1089/dia.2021.0521 Get It

Objective: Evaluating the feasibility of closed-loop insulin delivery with a zone model predictive control (zone-MPC) algorithm designed for pregnancy complicated by type 1 diabetes (T1D). Research Design and Methods: Pregnant women with T1D from 14 to 32 weeks gestation already using continuous glucose monitor (CGM) augmented pump therapy were enrolled in a 2-day multicenter supervised outpatient study evaluating pregnancy-specific zone-MPC based closed-loop control (CLC) with the interoperable artificial pancreas system (iAPS) running on an unlocked smartphone. Meals and activities were unrestricted. The primary outcome was the CGM percentage of time between 63 and 140 mg/dL compared with participants' 1-week run-in period. Early (2-h) postprandial glucose control was also evaluated. Results: Eleven participants completed the study (age: 30.6 ± 4.1 years; gestational age: 20.7 ± 3.5 weeks; weight: 76.5 ± 15.3 kg; hemoglobin A1c: 5.6% ± 0.5% at enrollment). No serious adverse events occurred. Compared with the 1-week run-in, there was an increased percentage of time in 63–140 mg/dL during supervised CLC (CLC: 81.5%, run-in: 64%, P = 0.007) with less time >140 mg/dL (CLC: 16.5%, run-in: 30.8%, P = 0.029) and time <63 mg/dL (CLC: 2.0%, run-in:5.2%, P = 0.039). There was also less time <54 mg/dL (CLC: 0.7%, run-in:1.6%, P = 0.030) and >180 mg/dL (CLC: 4.9%, run-in: 13.1%, P = 0.032). Overnight glucose control was comparable, except for less time >250 mg/dL (CLC: 0%, run-in:3.9%, P = 0.030) and lower glucose standard deviation (CLC: 23.8 mg/dL, run-in:42.8 mg/dL, P = 0.007) during CLC. Conclusion: In this pilot study, use of the pregnancy-specific zone-MPC was feasible in pregnant women with T1D. Although the duration of our study was short and the number of participants was small, our findings add to the limited data available on the use of CLC systems during pregnancy (NCT04492566).
Insulin Delivery and Glucose Variability Throughout the Menstrual Cycle on Closed Loop Control for Women with Type 1 Diabetes
O’Malley, Grenye , Raghinaru, Dan, Kudva, Yogish C. , Laffel, Lori M. , Pinsker, Jordan E. , Lum, John W. , Brown, Sue A. , Anderson, Stacey M. , Emory, Emma, Voelmle, Mary, Conshafter, Katie, Morris, Kim, Gondor-Fredrick, Linda, Mitchell, Harry, Calvo, Kayla, Wakeman, Christian, Breton, Marc D. , Ambler-Osborn, Louise, Flint, Emily, Kim, Kenny, Roethke, Lindsay, Church, Mei Mei , André, Camille , Piper, Molly, Lam, David W. , Levister, Camilla, Ogyaadu, Selassie, Lovett, Jessica, Simha, Vinaya , Dadlani, Vikash, McCrady-Spitzer, Shelly , Reid, Corey, Forlenza, Gregory P. , Slover, Robert H., Jost, Emily , Berget, Cari , Towers, Lindsey, Rossick-Solis, Alex, Ekhlaspour, Laya , Jacobson, Tali, Town, Marissa, Tabatabai, Ideen , Keller, Jordan, Salas, Evalina, Dassau, Eyal , Passman, Samantha, Campos, Tiffany, Kollman, Craig, Murphy, Carlos, Patibandla, Nandan, Borgman, Sarah, Arreaza-Rubín, Guillermo , Eggerman, Thomas L., Green, Neal, Reznik, Yves , Janicek, Robert, Gabrielson, Deanna, Belle, Steven H., Castle, Jessica R. , Legault, Laurent , Wysham, Carol , Kudva, Yogish C. , Laffel, Lori M , Pinsker, Jordan E , Lum, John , Forlenza, Gregory P , Levy, Carol J. , Kovatchev, Boris , Oliveri, Mary Clancy , Isganaitis, Elvira , Kumari, Kanchan, Wadwa, R Paul , Alonso, G. Todd , Messer, Laurel H , Buckingham, Bruce A. , Doyle, Francis J. , Beck, Roy W. , Kollman, Craig , Renard, Eric , Cobelli, Claudio , Green, Jennifer Greif , Willi, Steven Matthew

Diabetes Technology & Therapeutics | January 31, 2022 | Volume: 24 | Issue: 5 | Pages: 357-361

10.1089/dia.2021.0431 Get It

Objective: To analyze insulin delivery and glycemic metrics throughout the menstrual cycle for women with type 1 diabetes using closed loop control (CLC) insulin delivery. Methods: Menstruating women using a CLC system in a clinical trial were invited to record their menstrual cycles through a cycle-tracking application. Sixteen participants provided data for this secondary analysis over three or more complete cycles. Insulin delivery and continuous glucose monitoring (CGM) data were analyzed in relation to reported cycle phases. Results: Insulin delivery and CGM metrics remained consistent during cycle phases. Intraparticipant variability of CGM metrics and weight-based insulin delivery did not change through cycle phases. Conclusions: For this sample of menstruating women with type 1 diabetes using a CLC system, insulin delivery and glycemic metrics remained stable throughout menstrual cycle phases. Additional studies in this population are needed, particularly among women who report variable glycemic control during their cycles. Trial Registration: NCT03591354.
Patient-Reported Outcomes in a Randomized Trial of Closed-Loop Control: The Pivotal International Diabetes Closed-Loop Trial
Kudva, Yogish C. , Laffel, Lori M. , Brown, Sue A. , Raghinaru, Dan, Pinsker, Jordan E. , Ekhlaspour, Laya , Messer, Laurel H. , Kovatchev, Boris , Lum, John W. , Gonder‐Frederick, Linda , Anderson, Stacey M. , Emory, Emma, Voelmle, Mary, Conshafter, Katie, Morris, Kim, Mitchell, Harry, Calvo, Kayla, Wakeman, Christian, Breton, Marc D. , Ambler-Osborn, Louise, Flint, Emily, Kim, Kenny, Roethke, Lindsay, Church, Mei Mei , André, Camille , Piper, Molly, Lam, David W. , O’Malley, Grenye , Levister, Camilla, Ogyaadu, Selassie, Lovett, Jessica, Simha, Vinaya , Dadlani, Vikash, McCrady-Spitzer, Shelly , Reid, Corey, Forlenza, Gregory P. , Alonso, G. Todd, Slover, Robert H., Jost, Emily , Berget, Cari , Towers, Lindsey, Rossick-Solis, Alex, Buckingham, Bruce A. , Jacobson, Tali, Town, Marissa, Tabatabai, Ideen , Keller, Jordan, Salas, Evalina, Dassau, Eyal , Passman, Samantha, Campos, Tiffany, Kollman, Craig, Murphy, Carlos, Patibandla, Nandan, Borgman, Sarah, Arreaza-Rubín, Guillermo , Green, Neal, Reznik, Yves , Janicek, Robert, Gabrielson, Deanna, Belle, Steven H., Castle, Jessica R. , Legault, Laurent , Wysham, Carol , Eggerman, Thomas L., Messer, Laurel H , Lum, John , Forlenza, Gregory P , Kovatchev, Boris , Buckingham, Bruce , Levy, Carol J. , Beck, Roy W. , Oliveri, Mary Clancy , Isganaitis, Elvira , Kumari, Kanchan, Wadwa, R Paul , Doyle, Francis J. , Kollman, Craig , Renard, Eric , Cobelli, Claudio , Green, Jennifer Greif , Willi, Steven Matthew

Diabetes Technology & Therapeutics | June 11, 2021 | Volume: 23 | Issue: 10 | Pages: 673-683

10.1089/dia.2021.0089 Get It

Background: Closed-loop control (CLC) has been shown to improve glucose time in range and other glucose metrics; however, randomized trials >3 months comparing CLC with sensor-augmented pump (SAP) therapy are limited. We recently reported glucose control outcomes from the 6-month international Diabetes Closed-Loop (iDCL) trial; we now report patient-reported outcomes (PROs) in this iDCL trial. Methods: Participants were randomized 2:1 to CLC ( N = 112) versus SAP ( N = 56) and completed questionnaires, including Hypoglycemia Fear Survey, Diabetes Distress Scale (DDS), Hypoglycemia Awareness, Hypoglycemia Confidence, Hyperglycemia Avoidance, and Positive Expectancies of CLC (INSPIRE) at baseline, 3, and 6 months. CLC participants also completed Diabetes Technology Expectations and Acceptance and System Usability Scale (SUS). Results: The Hypoglycemia Fear Survey Behavior subscale improved significantly after 6 months of CLC compared with SAP. DDS did not differ except for powerless subscale scores, which worsened at 3 months in SAP. Whereas Hypoglycemia Awareness and Hyperglycemia Avoidance did not differ between groups, CLC participants showed a tendency toward improved confidence in managing hypoglycemia. The INSPIRE questionnaire showed favorable scores in the CLC group for teens and parents, with a similar trend for adults. At baseline and 6 months, CLC participants had high positive expectations for the device with Diabetes Technology Acceptance and SUS showing high benefit and low burden scores. Conclusion: CLC improved some PROs compared with SAP. Participants reported high benefit and low burden with CLC. Clinical Trial Identifier: NCT03563313.
Closed-Loop Insulin Therapy Improves Glycemic Control in Adolescents and Young Adults: Outcomes from the International Diabetes Closed-Loop Trial
Isganaitis, Elvira , Raghinaru, Dan, Ambler-Osborn, Louise, Pinsker, Jordan E. , Buckingham, Bruce A. , Ekhlaspour, Laya , Kudva, Yogish C., Forlenza, Gregory P. , Beck, Roy W., Kollman, Craig, Lum, John W. , Brown, Sue A. , Laffel, Lori M. , Kovatchev, Boris, Anderson, Stacey, Emory, Emma, Voelmle, Mary, Conshafter, Katie, Morris, Kim, Gondor-Fredrick, Linda, Mitchell, Harry, Calvo, Kayla, Wakeman, Christian, Breton, Marc, Flint, Emily, Kim, Kenny, Roethke, Lindsay, Church, Mei Mei , André, Camille , Piper, Molly, Lam, David , O’Malley, Grenye , Levister, Camilla, Ogyaadu, Selassie, Lovett, Jessica, Simha, Vinaya , Dadlani, Vikash, McCrady-Spitzer, Shelly , Reid, Corey, Alonso, G. Todd, Slover, Robert H., Jost, Emily , Berget, Cari, Towers, Lindsey, Rossick-Solis, Alex, Jacobson, Tali, Town, Marissa, Tabatabai, Ideen , Keller, Jordan, Salas, Evalina, Dassau, Eyal , Passman, Samantha, Campos, Tiffany, Murphy, Carlos, Patibandla, Nandan, Borgman, Sarah, Arreaza-Rubín, Guillermo , Green, Neal, Laffel, Lori, Pinsker, Jordan, Doyle, Francis, Renard, Eric, Reznik, Yves , Lum, John, Janicek, Robert, Gabrielson, Deanna, Belle, Steven H., Castle, Jessica R. , Green, Jennifer , Legault, Laurent , Wysham, Carol , Eggerman, Thomas, Forlenza, Gregory P , Buckingham, Bruce , Wadwa, R Paul , Kudva, Yogish C. , Levy, Carol J. , Kollman, Craig , Kovatchev, Boris , Anderson, Stacey M. , Oliveri, Mary Clancy , Kumari, Kanchan , Messer, Laurel H , Jacobson, Tali, Doyle, Francis J. , Patibandla, Nandan, Laffel, Lori M. , Cobelli, Claudio , Beck, Roy W. , Willi, Steven Matthew

Diabetes Technology & Therapeutics | November 20, 2020 | Volume: 23 | Issue: 5 | Pages: 342-349

10.1089/dia.2020.0572 Get It

Objective: To assess the efficacy and safety of closed-loop control (CLC) insulin delivery system in adolescents and young adults with type 1 diabetes. Research Design and Methods: Prespecified subanalysis of outcomes in adolescents and young adults aged 14–24 years old with type 1 diabetes in a previously published 6-month multicenter randomized trial. Participants were randomly assigned 2:1 to CLC (Tandem Control-IQ) or sensor augmented pump (SAP, various pumps+Dexcom G6 CGM) and followed for 6 months. Results: Mean age of the 63 participants was 17 years, median type 1 diabetes duration was 7 years, and mean baseline HbA1c was 8.1%. All 63 completed the trial. Time in range (TIR) increased by 13% with CLC versus decreasing by 1% with SAP (adjusted treatment group difference = +13% [+3.1 h/day]; 95% confidence interval [CI] 9–16, P < 0.001), which largely reflected a reduction in time >180 mg/dL (adjusted difference −12% [−2.9 h/day], P < 0.001). Time <70 mg/dL decreased by 1.6% with CLC versus 0.3% with SAP (adjusted difference −0.7% [−10 min/day], 95% CI −1.0% to −0.2%, P = 0.002). CLC use averaged 89% of the time for 6 months. The mean adjusted difference in HbA1c after 6 months was 0.30% in CLC versus SAP (95% CI −0.67 to +0.08, P = 0.13). There was one diabetic ketoacidosis episode in the CLC group. Conclusions: CLC use for 6 months was substantial and associated with improved TIR and reduced hypoglycemia in adolescents and young adults with type 1 diabetes. Thus, CLC has the potential to improve glycemic outcomes in this challenging age group. The clinical trial was registered with ClinicalTrials.gov (NCT03563313).