Objective: To assess the efficacy and safety of closed-loop control (CLC) insulin delivery system in adolescents and young adults with type 1 diabetes. Research Design and Methods: Prespecified subanalysis of outcomes in adolescents and young adults aged 14–24 years old with type 1 diabetes in a previously published 6-month multicenter randomized trial. Participants were randomly assigned 2:1 to CLC (Tandem Control-IQ) or sensor augmented pump (SAP, various pumps+Dexcom G6 CGM) and followed for 6 months. Results: Mean age of the 63 participants was 17 years, median type 1 diabetes duration was 7 years, and mean baseline HbA1c was 8.1%. All 63 completed the trial. Time in range (TIR) increased by 13% with CLC versus decreasing by 1% with SAP (adjusted treatment group difference = +13% [+3.1 h/day]; 95% confidence interval [CI] 9–16, P < 0.001), which largely reflected a reduction in time >180 mg/dL (adjusted difference −12% [−2.9 h/day], P < 0.001). Time <70 mg/dL decreased by 1.6% with CLC versus 0.3% with SAP (adjusted difference −0.7% [−10 min/day], 95% CI −1.0% to −0.2%, P = 0.002). CLC use averaged 89% of the time for 6 months. The mean adjusted difference in HbA1c after 6 months was 0.30% in CLC versus SAP (95% CI −0.67 to +0.08, P = 0.13). There was one diabetic ketoacidosis episode in the CLC group. Conclusions: CLC use for 6 months was substantial and associated with improved TIR and reduced hypoglycemia in adolescents and young adults with type 1 diabetes. Thus, CLC has the potential to improve glycemic outcomes in this challenging age group. The clinical trial was registered with ClinicalTrials.gov (NCT03563313).
Clinical Management and Pump Parameter Adjustment of the Control-IQ Closed-Loop Control System: Results from a 6-Month, Multicenter, Randomized Clinical Trial
Background: Data are limited on the need for and benefits of pump setting optimization with automated insulin delivery. We examined clinical management of a closed-loop control (CLC) system and its relationship to glycemic outcomes. Materials and Methods: We analyzed personal parameter adjustments in 168 participants in a 6-month multicenter trial of CLC with Control-IQ versus sensor-augmented pump (SAP) therapy. Preset parameters (BR = basal rates, CF = correction factors, CR = carbohydrate ratios) were optimized at randomization, 2 and 13 weeks, for safety issues, participant concerns, or initiation by participants' usual diabetes care team. Time in range (TIR 70–180 mg/dL) was compared in the week before and after parameter changes. Results: In 607 encounters for parameter changes, there were fewer adjustments for CLC than SAP (3.4 vs. 4.1/participant). Adjustments involved BR (CLC 69%, SAP 80%), CR (CLC 68%, SAP 50%), CF (CLC 44%, SAP 41%), and overnight parameters (CLC 62%, SAP 75%). TIR before and after adjustments was 71.2% and 71.3% for CLC and 61.0% and 62.9% for SAP. The highest baseline HbA 1c CLC subgroup had the largest TIR improvement (51.2% vs. 57.7%). When a CR was made more aggressive in the CLC group, postprandial time >180 mg/dL was 43.1% before the change and 36.0% after the change. The median postprandial time <70 mg/dL before making CR less aggressive was 1.8%, and after the change was 0.7%. Conclusions: No difference in TIR was detected with parameter changes overall, but they may have an effect in higher HbA 1c subgroups or following user-directed boluses, suggesting that changes may matter more in suboptimal control or during discrete periods of the day. Clinical Trials Registration number: NCT03563313.
Glycemic Outcomes of Use of CLC Versus PLGS in Type 1 Diabetes: A Randomized Controlled Trial
OBJECTIVE Limited information is available about glycemic outcomes with a closed-loop control (CLC) system compared with a predictive low-glucose suspend (PLGS) system. RESEARCH DESIGN AND METHODS After 6 months of use of a CLC system in a randomized trial, 109 participants with type 1 diabetes (age range, 14–72 years; mean HbA1c, 7.1% [54 mmol/mol]) were randomly assigned to CLC (N = 54, Control-IQ) or PLGS (N = 55, Basal-IQ) groups for 3 months. The primary outcome was continuous glucose monitor (CGM)-measured time in range (TIR) for 70–180 mg/dL. Baseline CGM metrics were computed from the last 3 months of the preceding study. RESULTS All 109 participants completed the study. Mean ± SD TIR was 71.1 ± 11.2% at baseline and 67.6 ± 12.6% using intention-to-treat analysis (69.1 ± 12.2% using per-protocol analysis excluding periods of study-wide suspension of device use) over 13 weeks on CLC vs. 70.0 ± 13.6% and 60.4 ± 17.1% on PLGS (difference = 5.9%; 95% CI 3.6%, 8.3%; P < 0.001). Time >180 mg/dL was lower in the CLC group than PLGS group (difference = −6.0%; 95% CI −8.4%, −3.7%; P < 0.001) while time <54 mg/dL was similar (0.04%; 95% CI −0.05%, 0.13%; P = 0.41). HbA1c after 13 weeks was lower on CLC than PLGS (7.2% [55 mmol/mol] vs. 7.5% [56 mmol/mol], difference −0.34% [−3.7 mmol/mol]; 95% CI −0.57% [−6.2 mmol/mol], −0.11% [1.2 mmol/mol]; P = 0.0035). CONCLUSIONS Following 6 months of CLC, switching to PLGS reduced TIR and increased HbA1c toward their pre-CLC values, while hypoglycemia remained similarly reduced with both CLC and PLGS.
Continuous glucose monitoring to assess glycemic control in the first 6 weeks after pancreas transplantation
AbstractBackgroundCurrent therapy for Type 1 diabetes (T1D) is characterized by significant glucose variability (GV). Pancreas transplantation (PT) is performed in certain T1D patients with and without end‐stage renal disease. To date, GV has been examined to a limited extent after PT.MethodsWe investigated GV using continuous glucose monitoring (CGM) 3‐6 weeks after PT.ResultsEleven patients had simultaneous kidney pancreas transplantation (SPK), nine pancreas after kidney (PAK), and six pancreas transplantation alone (PTA). Mean CGM showed no difference between SPK, 126.5 ± 13.9, PAK 119.9 ± 12.8, and PTA 131.1 ± 29 mg/dL (P value .6). Percentage of time in range (TIR, 70‐180 mg/dL) was 92% for SPK, 93.4% in PAK, and 88.5% in PTA with only 0.3%, 1.5%, and 0.3% of time <70 mg/dL. Percentage >180 mg/dL was 7.9% for SPK, 4.9% PAK, and 11% in PTA. Other measures of GV were similar in the three cohorts. In six patients, CGM was performed before and after PT and improved significantly. GV was also better compared with a matched cohort of T1D patients.ConclusionsAll 3 types of PT resulted in excellent glucose control 3‐6 weeks post‐procedure. CGM outcomes represent an important objective outcome after PT.
SUN-133 Glycemic Control in T1D Subjects before and after Pancreas Transplantation