Back to Authors

Breton, Marc D.

https://orcid.org/0000-0001-7645-2693

Mayo Clinic

University of Virginia

Citations 9

Early Stages of Automated Insulin Delivery
Zisser, Howard , Hovorka, Roman , Basu, Ananda , Battelino, Tadej , Boughton, Charlotte K. , Breton, Marc D. , Buckingham, Bruce A. , Brown, Sue A. , Cherñavvsky, Daniel R. , Dassau, Eyal , Ekhlaspour, Laya , Forlenza, Gregory P. , Haidar, Ahmad , Klonoff, David C. , Kovatchev, Boris , Kowalski, Aaron J. , Kudva, Yogish C., Maahs, David M. , Phillip, Moshe , Russell, Steven J. , Steil, Garry M. , Weinzimer, Stuart A. , Doyle, Francis J , Ekhlaspour, Laya , Fabris, Chiara , Forlenza, Gregory P , Klonoff, David C , Kovatchev, Boris , Levy, Carol J , Maahs, David M , Phillip, Moshe , Renard, Eric , Russell, Steven J , Shah, Viral N , Wadwa, R Paul , Battelino, Tadej , Hovorka, Roman , Buckingham, Bruce , DeBoer, Mark Daniel , Doyle, Francis J. , Levy, Carol J. , Kudva, Yogish C. , Shah, Viral N.

Diabetes Technology & Therapeutics | July 1, 2025 | Volume: 27 | Issue: 3_suppl | Pages: No page available

10.1089/dia.2025.18802.hz Get It

The development of automated insulin delivery systems has seen tremendous improvements from individual components to interoperable system combinations of devices and new drugs besides insulin. The components have become progressively smaller, more accurate, and more user friendly. This article summarizes the history of the artificial pancreas from the earliest concepts to fully functional systems to research into further improvements in the future. The authors include many of the developers of this technology who received research support from the National Institute of Diabetes and Digestive and Kidney Diseases at various stages to develop these systems.
Early Stages of Automated Insulin Delivery
Zisser, Howard , Hovorka, Roman , Basu, Ananda , Battelino, Tadej , Boughton, Charlotte K. , Breton, Marc D. , Buckingham, Bruce A. , Brown, Sue A. , Cherñavvsky, Daniel R. , Dassau, Eyal , Ekhlaspour, Laya , Forlenza, Gregory P. , Haidar, Ahmad , Klonoff, David C. , Kovatchev, Boris , Kowalski, Aaron J. , Kudva, Yogish C. , Maahs, David M. , Phillip, Moshe , Russell, Steven J. , Steil, Garry M. , Weinzimer, Stuart A. , Doyle, Francis J , Ekhlaspour, Laya , Fabris, Chiara , Forlenza, Gregory P , Klonoff, David C , Kovatchev, Boris , Levy, Carol J , Maahs, David M , Phillip, Moshe , Renard, Eric , Russell, Steven J , Shah, Viral N , Wadwa, R Paul , Battelino, Tadej , Hovorka, Roman , Buckingham, Bruce , DeBoer, Mark Daniel , Doyle, Francis J. , Levy, Carol J. , Shah, Viral N.

Journal of Diabetes Science and Technology | July 1, 2025 | Volume: 19 | Issue: 4 | Pages: 908-923

10.1177/19322968251335685 Get It

The development of automated insulin delivery systems has seen tremendous improvements from individual components to interoperable system combinations of devices and new drugs besides insulin. The components have become progressively smaller, more accurate, and more user friendly. This article summarizes the history of the artificial pancreas from the earliest concepts to fully functional systems to research into further improvements in the future. The authors include many of the developers of this technology who received research support from the National Institute of Diabetes and Digestive and Kidney Diseases at various stages to develop these systems.
A Glycemia Risk Index (GRI) of Hypoglycemia and Hyperglycemia for Continuous Glucose Monitoring Validated by Clinician Ratings
Klonoff, David C. , Wang, Jing , Rodbard, David , Kohn, Michael A. , Li, Chengdong , Liepmann, Dorian , Kerr, David , Ahn, David , Peters, Anne L. , Umpierrez, Guillermo E. , Xu, Nicole Y. , Nguyen, Kevin T. , Simonson, Gregg D. , Agus, Michael S. D. , Armaiz-Peña, Gustavo , Basu, Ananda , Battelino, Tadej , Yeshiwas, Sewagegn , Bequette, B. Wayne , Blevins, Thomas , Breton, Marc D. , Castle, Jessica R. , Close, Kelly L. , Drincic, Angela, Dungan, Kathleen , Ejskjær, Niels , Espinoza, Juan , Fleming, G. Alexander , Forlenza, Gregory P. , Freckmann, Guido , Galindo, Rodolfo J. , Gómez, Ana María , Gutow, Hanna A. , Hovorka, Roman , Ji, Linong , Joubert, Michaël , Koliwad, Suneil K. , Lal, Rayhan , Lansang, M. Cecilia , Lee, Wei-An , Leelarathna, Lalantha , Lind, Marcus , Mahoney, Katherine , Mankovsky, Boris , Masharani, Umesh , Mathioudakis, Nestoras , Mayorov, Alexander Yur'evich , Messler, Jordan , Mohan, Viswanathan , Nichols, James H. , O’Neal, David N. , Pasquel, Francisco J. , Philis‐Tsimikas, Athena , Phillip, Moshe , Rayman, Gerry , Russell, Steven J. , Spanakis, Elias K. , Waki, Kayo , Wallia, Amisha , Weinberg, Melissa E. , Wolpert, Howard , Zilbermint, Mihail , Kovatchev, Boris , Seley, Jane Jeffrie , Xu, Nicole Y , Nguyen, Kevin T , Simonson, Gregg , Agus, Michael S D , Al-Sofiani, Mohammed E , Armaiz-Pena, Gustavo , Bailey, Timothy S , Basu, Ananda , Battelino, Tadej , Bekele, Sewagegn Yeshiwas , Benhamou, Pierre-Yves , Bequette, B Wayne , Blevins, Thomas , Breton, Marc D , Castle, Jessica R , Chase, James Geoffrey , Chen, Kong , Choudhary, Pratik , Clements, Mark A , Close, Kelly L , Cook, Curtiss B , Doyle, Francis J , Drincic, Angela , Dungan, Kathleen M , Edelman, Steven V , Ejskjaer, Niels , Espinoza, Juan , Fleming, G Alexander , Forlenza, Gregory P , Freckmann, Guido , Galindo, Rodolfo J , Gomez, Ana Maria , Gutow, Hanna A , Heinemann, Lutz , Hirsch, Irl B , Hoang, Thanh D , Hovorka, Roman , Jendle, Johan H , Ji, Linong , Joshi, Shashank R , Joubert, Michael , Koliwad, Suneil K , Lal, Rayhan A , Lansang, M Cecilia , Lee, Wei-An Andy , Leelarathna, Lalantha , Leiter, Lawrence A , Lind, Marcus , Litchman, Michelle L , Mader, Julia K , Mahoney, Katherine M , Mankovsky, Boris , Masharani, Umesh , Mathioudakis, Nestoras N , Mayorov, Alexander , Messler, Jordan , Miller, Joshua D , Mohan, Viswanathan , Nichols, James H , Nørgaard, Kirsten , O'Neal, David N , Pasquel, Francisco J , Philis-Tsimikas, Athena , Pieber, Thomas , Phillip, Moshe , Polonsky, William H , Pop-Busui, Rodica , Rayman, Gerry , Rhee, Eun-Jung , Russell, Steven J , Shah, Viral N , Sherr, Jennifer L , Sode, Koji , Spanakis, Elias K , Wake, Deborah J , Waki, Kayo , Wallia, Amisha , Weinberg, Melissa E , Wolpert, Howard , Wright, Eugene E , Zilbermint, Mihail , Kovatchev, Boris , Kohn, Michael , Umpierrez, Guillermo E. , Peters, Anne L , Ahn, David T , Liepmann, Dorian , Bailey, Timothy S. , Chen, Kong Y. , Choudhary, Pratik , Cook, Curtiss B. , Danne, Thomas , Doyle, Francis J. , Heinemann, Lutz , Hirsch, Irl B. , Leiter, Lawrence A. , Mader, Julia K. , Pop‐Busui, Rodica , Shah, Viral N. , Sode, Koji , Wright, Eugene E.

Journal of Diabetes Science and Technology | March 29, 2022 | Volume: 17 | Issue: 5 | Pages: 1226-1242

10.1177/19322968221085273 Get It

Background: A composite metric for the quality of glycemia from continuous glucose monitor (CGM) tracings could be useful for assisting with basic clinical interpretation of CGM data. Methods: We assembled a data set of 14-day CGM tracings from 225 insulin-treated adults with diabetes. Using a balanced incomplete block design, 330 clinicians who were highly experienced with CGM analysis and interpretation ranked the CGM tracings from best to worst quality of glycemia. We used principal component analysis and multiple regressions to develop a model to predict the clinician ranking based on seven standard metrics in an Ambulatory Glucose Profile: very low–glucose and low-glucose hypoglycemia; very high–glucose and high-glucose hyperglycemia; time in range; mean glucose; and coefficient of variation. Results: The analysis showed that clinician rankings depend on two components, one related to hypoglycemia that gives more weight to very low-glucose than to low-glucose and the other related to hyperglycemia that likewise gives greater weight to very high-glucose than to high-glucose. These two components should be calculated and displayed separately, but they can also be combined into a single Glycemia Risk Index (GRI) that corresponds closely to the clinician rankings of the overall quality of glycemia (r = 0.95). The GRI can be displayed graphically on a GRI Grid with the hypoglycemia component on the horizontal axis and the hyperglycemia component on the vertical axis. Diagonal lines divide the graph into five zones (quintiles) corresponding to the best (0th to 20th percentile) to worst (81st to 100th percentile) overall quality of glycemia. The GRI Grid enables users to track sequential changes within an individual over time and compare groups of individuals. Conclusion: The GRI is a single-number summary of the quality of glycemia. Its hypoglycemia and hyperglycemia components provide actionable scores and a graphical display (the GRI Grid) that can be used by clinicians and researchers to determine the glycemic effects of prescribed and investigational treatments.
Insulin Delivery and Glucose Variability Throughout the Menstrual Cycle on Closed Loop Control for Women with Type 1 Diabetes
O’Malley, Grenye , Raghinaru, Dan, Kudva, Yogish C. , Laffel, Lori M. , Pinsker, Jordan E. , Lum, John W. , Brown, Sue A. , Anderson, Stacey M. , Emory, Emma, Voelmle, Mary, Conshafter, Katie, Morris, Kim, Gondor-Fredrick, Linda, Mitchell, Harry, Calvo, Kayla, Wakeman, Christian, Breton, Marc D. , Ambler-Osborn, Louise, Flint, Emily, Kim, Kenny, Roethke, Lindsay, Church, Mei Mei , André, Camille , Piper, Molly, Lam, David W. , Levister, Camilla, Ogyaadu, Selassie, Lovett, Jessica, Simha, Vinaya , Dadlani, Vikash, McCrady-Spitzer, Shelly , Reid, Corey, Forlenza, Gregory P. , Slover, Robert H., Jost, Emily , Berget, Cari , Towers, Lindsey, Rossick-Solis, Alex, Ekhlaspour, Laya , Jacobson, Tali, Town, Marissa, Tabatabai, Ideen , Keller, Jordan, Salas, Evalina, Dassau, Eyal , Passman, Samantha, Campos, Tiffany, Kollman, Craig, Murphy, Carlos, Patibandla, Nandan, Borgman, Sarah, Arreaza-Rubín, Guillermo , Eggerman, Thomas L., Green, Neal, Reznik, Yves , Janicek, Robert, Gabrielson, Deanna, Belle, Steven H., Castle, Jessica R. , Legault, Laurent , Wysham, Carol , Kudva, Yogish C. , Laffel, Lori M , Pinsker, Jordan E , Lum, John , Forlenza, Gregory P , Levy, Carol J. , Kovatchev, Boris , Oliveri, Mary Clancy , Isganaitis, Elvira , Kumari, Kanchan, Wadwa, R Paul , Alonso, G. Todd , Messer, Laurel H , Buckingham, Bruce A. , Doyle, Francis J. , Beck, Roy W. , Kollman, Craig , Renard, Eric , Cobelli, Claudio , Green, Jennifer Greif , Willi, Steven Matthew

Diabetes Technology & Therapeutics | January 31, 2022 | Volume: 24 | Issue: 5 | Pages: 357-361

10.1089/dia.2021.0431 Get It

Objective: To analyze insulin delivery and glycemic metrics throughout the menstrual cycle for women with type 1 diabetes using closed loop control (CLC) insulin delivery. Methods: Menstruating women using a CLC system in a clinical trial were invited to record their menstrual cycles through a cycle-tracking application. Sixteen participants provided data for this secondary analysis over three or more complete cycles. Insulin delivery and continuous glucose monitoring (CGM) data were analyzed in relation to reported cycle phases. Results: Insulin delivery and CGM metrics remained consistent during cycle phases. Intraparticipant variability of CGM metrics and weight-based insulin delivery did not change through cycle phases. Conclusions: For this sample of menstruating women with type 1 diabetes using a CLC system, insulin delivery and glycemic metrics remained stable throughout menstrual cycle phases. Additional studies in this population are needed, particularly among women who report variable glycemic control during their cycles. Trial Registration: NCT03591354.
Patient-Reported Outcomes in a Randomized Trial of Closed-Loop Control: The Pivotal International Diabetes Closed-Loop Trial
Kudva, Yogish C. , Laffel, Lori M. , Brown, Sue A. , Raghinaru, Dan, Pinsker, Jordan E. , Ekhlaspour, Laya , Messer, Laurel H. , Kovatchev, Boris , Lum, John W. , Gonder‐Frederick, Linda , Anderson, Stacey M. , Emory, Emma, Voelmle, Mary, Conshafter, Katie, Morris, Kim, Mitchell, Harry, Calvo, Kayla, Wakeman, Christian, Breton, Marc D. , Ambler-Osborn, Louise, Flint, Emily, Kim, Kenny, Roethke, Lindsay, Church, Mei Mei , André, Camille , Piper, Molly, Lam, David W. , O’Malley, Grenye , Levister, Camilla, Ogyaadu, Selassie, Lovett, Jessica, Simha, Vinaya , Dadlani, Vikash, McCrady-Spitzer, Shelly , Reid, Corey, Forlenza, Gregory P. , Alonso, G. Todd, Slover, Robert H., Jost, Emily , Berget, Cari , Towers, Lindsey, Rossick-Solis, Alex, Buckingham, Bruce A. , Jacobson, Tali, Town, Marissa, Tabatabai, Ideen , Keller, Jordan, Salas, Evalina, Dassau, Eyal , Passman, Samantha, Campos, Tiffany, Kollman, Craig, Murphy, Carlos, Patibandla, Nandan, Borgman, Sarah, Arreaza-Rubín, Guillermo , Green, Neal, Reznik, Yves , Janicek, Robert, Gabrielson, Deanna, Belle, Steven H., Castle, Jessica R. , Legault, Laurent , Wysham, Carol , Eggerman, Thomas L., Messer, Laurel H , Lum, John , Forlenza, Gregory P , Kovatchev, Boris , Buckingham, Bruce , Levy, Carol J. , Beck, Roy W. , Oliveri, Mary Clancy , Isganaitis, Elvira , Kumari, Kanchan, Wadwa, R Paul , Doyle, Francis J. , Kollman, Craig , Renard, Eric , Cobelli, Claudio , Green, Jennifer Greif , Willi, Steven Matthew

Diabetes Technology & Therapeutics | June 11, 2021 | Volume: 23 | Issue: 10 | Pages: 673-683

10.1089/dia.2021.0089 Get It

Background: Closed-loop control (CLC) has been shown to improve glucose time in range and other glucose metrics; however, randomized trials >3 months comparing CLC with sensor-augmented pump (SAP) therapy are limited. We recently reported glucose control outcomes from the 6-month international Diabetes Closed-Loop (iDCL) trial; we now report patient-reported outcomes (PROs) in this iDCL trial. Methods: Participants were randomized 2:1 to CLC ( N = 112) versus SAP ( N = 56) and completed questionnaires, including Hypoglycemia Fear Survey, Diabetes Distress Scale (DDS), Hypoglycemia Awareness, Hypoglycemia Confidence, Hyperglycemia Avoidance, and Positive Expectancies of CLC (INSPIRE) at baseline, 3, and 6 months. CLC participants also completed Diabetes Technology Expectations and Acceptance and System Usability Scale (SUS). Results: The Hypoglycemia Fear Survey Behavior subscale improved significantly after 6 months of CLC compared with SAP. DDS did not differ except for powerless subscale scores, which worsened at 3 months in SAP. Whereas Hypoglycemia Awareness and Hyperglycemia Avoidance did not differ between groups, CLC participants showed a tendency toward improved confidence in managing hypoglycemia. The INSPIRE questionnaire showed favorable scores in the CLC group for teens and parents, with a similar trend for adults. At baseline and 6 months, CLC participants had high positive expectations for the device with Diabetes Technology Acceptance and SUS showing high benefit and low burden scores. Conclusion: CLC improved some PROs compared with SAP. Participants reported high benefit and low burden with CLC. Clinical Trial Identifier: NCT03563313.
Clinical Management and Pump Parameter Adjustment of the Control-IQ Closed-Loop Control System: Results from a 6-Month, Multicenter, Randomized Clinical Trial
O’Malley, Grenye , Messer, Laurel H. , Pinsker, Jordan E. , Forlenza, Gregory P. , Isganaitis, Elvira , Kudva, Yogish C. , Ekhlaspour, Laya , Raghinaru, Dan, Lum, John W. , Brown, Sue A. , Kovatchev, Boris, Anderson, Stacey M. , Emory, Emma, Voelmle, Mary, Conshafter, Katie, Morris, Kim, Gondor-Fredrick, Linda, Mitchell, Harry, Calvo, Kayla, Wakeman, Christian, Breton, Marc D. , Laffel, Lori M. , E.I., Ambler-Osborn, Louise, Flint, Emily, Kim, Kenny, Roethke, Lindsay, J.E.P., Church, Mei Mei , André, Camille , Piper, Molly, C.J.L., Lam, David W. , G.O., Levister, Camilla, Ogyaadu, Selassie, Lovett, Jessica, Simha, Vinaya , Dadlani, Vikash, McCrady-Spitzer, Shelly , Reid, Corey, Wadwa, R. Paul, Alonso, G. Todd, Slover, Robert H., Jost, Emily , L.H.M., Berget, Cari, Towers, Lindsey, Rossick-Solis, Alex, Buckingham, Bruce, L.E., Jacobson, Tali, Town, Marissa, Tabatabai, Ideen , Keller, Jordan, Salas, Evalina, Paulson, John A., Beck, Jan-Philipp, Passman, Samantha, Campos, Tiffany, Kollman, D.R. Craig, Murphy, Carlos, Patibandla, Nandan, Borgman, Sarah, Arreza-Rubin, Guillermo, Eggerman, Thomas L., Green, Neal, Kovatchev, Boris, Arreza-Rubin, Guillermo, J.E.P., C.J.L., Y.C.K., Wadwa, R. Paul, Reznik, Yves , Arreza-Rubin, Guillermo, Buckingham, Bruce A. , Forlenza, Gregory P , Messer, Laurel H , Buckingham, Bruce , Levy, Carol J. , Pinsker, Jordan E. , Kovatchev, Boris , Kovatchev, Boris, Oliveri, Mary Clancy , E.I., J.E.P., C.J.L., G.O., Wadwa, R Paul , Kumari, Kanchan , Wadwa, R. Paul, L.H.M., L.E., Town, Marissa, Paulson, John A., Patibandla, Nandan, Arreza-Rubin, Guillermo, Kovatchev, Boris, Arreza-Rubin, Guillermo, J.E.P., C.J.L., Y.C.K., Wadwa, R. Paul, Renard, Eric , Cobelli, Claudio , Arreza-Rubin, Guillermo

Diabetes Technology & Therapeutics | November 6, 2020 | Volume: 23 | Issue: 4 | Pages: 245-252

10.1089/dia.2020.0472 Get It

Background: Data are limited on the need for and benefits of pump setting optimization with automated insulin delivery. We examined clinical management of a closed-loop control (CLC) system and its relationship to glycemic outcomes. Materials and Methods: We analyzed personal parameter adjustments in 168 participants in a 6-month multicenter trial of CLC with Control-IQ versus sensor-augmented pump (SAP) therapy. Preset parameters (BR = basal rates, CF = correction factors, CR = carbohydrate ratios) were optimized at randomization, 2 and 13 weeks, for safety issues, participant concerns, or initiation by participants' usual diabetes care team. Time in range (TIR 70–180 mg/dL) was compared in the week before and after parameter changes. Results: In 607 encounters for parameter changes, there were fewer adjustments for CLC than SAP (3.4 vs. 4.1/participant). Adjustments involved BR (CLC 69%, SAP 80%), CR (CLC 68%, SAP 50%), CF (CLC 44%, SAP 41%), and overnight parameters (CLC 62%, SAP 75%). TIR before and after adjustments was 71.2% and 71.3% for CLC and 61.0% and 62.9% for SAP. The highest baseline HbA 1c CLC subgroup had the largest TIR improvement (51.2% vs. 57.7%). When a CR was made more aggressive in the CLC group, postprandial time >180 mg/dL was 43.1% before the change and 36.0% after the change. The median postprandial time <70 mg/dL before making CR less aggressive was 1.8%, and after the change was 0.7%. Conclusions: No difference in TIR was detected with parameter changes overall, but they may have an effect in higher HbA 1c subgroups or following user-directed boluses, suggesting that changes may matter more in suboptimal control or during discrete periods of the day. Clinical Trials Registration number: NCT03563313.
Glycemic Outcomes of Use of CLC Versus PLGS in Type 1 Diabetes: A Randomized Controlled Trial
Brown, Sue A. , Beck, Roy W. , Raghinaru, Dan, Buckingham, Bruce A. , Laffel, Lori M. , Kudva, Yogish C. , Pinsker, Jordan E. , Dassau, Eyal , Ambler-Osborn, Louise, Anderson, Stacey M. , Church, Mei Mei , Ekhlaspour, Laya , Forlenza, Gregory P. , Levister, Camilla, Simha, Vinaya , Breton, Marc D. , Kollman, Craig, Lum, John W. , Kovatchev, Boris , Emory, Emma, Voelmle, Mary, Conshafter, Katie, Morris, Kim, Gondor-Fredrick, Linda, Mitchell, Harry, Calvo, Kayla, Wakeman, Christian, Isganaitis, Elvira , Flint, Emily, Kim, Kenny, Roethke, Lindsay, André, Camille , Piper, Molly, Lam, David W. , O’Malley, Grenye , Ogyaadu, Selassie, Lovett, Jessica, Dadlani, Vikash, McCrady-Spitzer, Shelly , Reid, Corey, Slover, Robert H., Jost, Emily , Berget, Cari , Towers, Lindsey, Rossick-Solis, Alex, Jacobson, Tali, Town, Marissa, Tabatabai, Ideen , Keller, Jordan, Salas, Evalina, Passman, Samantha, Campos, Tiffany, Murphy, Carlos, Patibandla, Nandan, Borgman, Sarah, Arreza-Rubin, Guillermo, Eggerman, Thomas L., Green, Neal, Reznik, Yves , Janicek, Robert, Gabrielson, Deanna, Belle, Steven H., Castle, Jessica R. , Legault, Laurent , Wysham, Carol , Kudva, Yogish C. , Pinsker, Jordan E , Dassau, Eyal , Doyle, Francis J , Ekhlaspour, Laya , Forlenza, Gregory P , Breton, Marc D , Lum, John , Kovatchev, Boris , Buckingham, Bruce , Beck, Roy W , Wadwa, R Paul , Levy, Carol J. , Doyle, Francis J. , Kollman, Craig , Oliveri, Mary Clancy , Kumari, Kanchan , Alonso, G. Todd , Messer, Laurel H , Renard, Eric , Cobelli, Claudio , Green, Jennifer Greif , Willi, Steven Matthew

Diabetes Care | May 30, 2020 | Volume: 43 | Issue: 8 | Pages: 1822-1828

10.2337/dc20-0124 Get It

OBJECTIVE Limited information is available about glycemic outcomes with a closed-loop control (CLC) system compared with a predictive low-glucose suspend (PLGS) system. RESEARCH DESIGN AND METHODS After 6 months of use of a CLC system in a randomized trial, 109 participants with type 1 diabetes (age range, 14–72 years; mean HbA1c, 7.1% [54 mmol/mol]) were randomly assigned to CLC (N = 54, Control-IQ) or PLGS (N = 55, Basal-IQ) groups for 3 months. The primary outcome was continuous glucose monitor (CGM)-measured time in range (TIR) for 70–180 mg/dL. Baseline CGM metrics were computed from the last 3 months of the preceding study. RESULTS All 109 participants completed the study. Mean ± SD TIR was 71.1 ± 11.2% at baseline and 67.6 ± 12.6% using intention-to-treat analysis (69.1 ± 12.2% using per-protocol analysis excluding periods of study-wide suspension of device use) over 13 weeks on CLC vs. 70.0 ± 13.6% and 60.4 ± 17.1% on PLGS (difference = 5.9%; 95% CI 3.6%, 8.3%; P &lt; 0.001). Time &gt;180 mg/dL was lower in the CLC group than PLGS group (difference = −6.0%; 95% CI −8.4%, −3.7%; P &lt; 0.001) while time &lt;54 mg/dL was similar (0.04%; 95% CI −0.05%, 0.13%; P = 0.41). HbA1c after 13 weeks was lower on CLC than PLGS (7.2% [55 mmol/mol] vs. 7.5% [56 mmol/mol], difference −0.34% [−3.7 mmol/mol]; 95% CI −0.57% [−6.2 mmol/mol], −0.11% [1.2 mmol/mol]; P = 0.0035). CONCLUSIONS Following 6 months of CLC, switching to PLGS reduced TIR and increased HbA1c toward their pre-CLC values, while hypoglycemia remained similarly reduced with both CLC and PLGS.
Randomized Controlled Trial of Mobile Closed-Loop Control
Kovatchev, Boris , Anderson, Stacey M. , Raghinaru, Dan, Kudva, Yogish C. , Laffel, Lori M. , Pinsker, Jordan E. , Buckingham, Bruce A. , Doyle, Francis J. , Brown, Sue A. , Church, Mei Mei , Dadlani, Vikash, Dassau, Eyal , Ekhlaspour, Laya , Forlenza, Gregory P. , Isganaitis, Elvira , Lam, David W. , Lum, John W. , Group, iDCL Study, Emory, Emma, Voelmle, Mary, Conshafter, Katie, Morris, Kim, Mitchell, Harry, Calvo, Kayla, Wakeman, Christian, Breton, Marc D. , Ambler-Osborn, Louise, Flint, Emily, Schultz, Alan , Kim, Kenny, Church, Mei Mei, André, Camille , Lam, David W., O’Malley, Grenye , Levister, Camilla, Ogyaadu, Selassie, Simha, Vinaya , McCrady-Spitzer, Shelly , Reid, Corey, Jost, Emily , Berget, Cari , Towers, Lindsey, Buckingham, Bruce, Ekhlaspour, Laya, Hsu, Liana, Loebner, Sarah E., Doyle, Francis J., Campos, Tiffany, Passman, Samantha, Murphy, Carlos, Patibandla, Nandan, Kollman, Craig, Pinsker, Jordan E , Doyle, Francis J , Dassau, Eyal , Ekhlaspour, Laya , Forlenza, Gregory P , Lum, John , Kovatchev, Boris , Buckingham, Bruce , Levy, Carol J. , Wadwa, R Paul , Beck, Roy W. , Group, iDCL Study, Oliveri, Mary Clancy , Church, Mei Mei, Lam, David W., Messer, Laurel H , Buckingham, Bruce, Ekhlaspour, Laya, Doyle, Francis J., Kollman, Craig

Diabetes Care | January 15, 2020 | Volume: 43 | Issue: 3 | Pages: 607-615

10.2337/dc19-1310 Get It

OBJECTIVE Assess the efficacy of inControl AP, a mobile closed-loop control (CLC) system. RESEARCH DESIGN AND METHODS This protocol, NCT02985866, is a 3-month parallel-group, multicenter, randomized unblinded trial designed to compare mobile CLC with sensor-augmented pump (SAP) therapy. Eligibility criteria were type 1 diabetes for at least 1 year, use of insulin pumps for at least 6 months, age ≥14 years, and baseline HbA1c &lt;10.5% (91 mmol/mol). The study was designed to assess two coprimary outcomes: superiority of CLC over SAP in continuous glucose monitor (CGM)–measured time below 3.9 mmol/L and noninferiority in CGM-measured time above 10 mmol/L. RESULTS Between November 2017 and May 2018, 127 participants were randomly assigned 1:1 to CLC (n = 65) versus SAP (n = 62); 125 participants completed the study. CGM time below 3.9 mmol/L was 5.0% at baseline and 2.4% during follow-up in the CLC group vs. 4.7% and 4.0%, respectively, in the SAP group (mean difference −1.7% [95% CI −2.4, −1.0]; P &lt; 0.0001 for superiority). CGM time above 10 mmol/L was 40% at baseline and 34% during follow-up in the CLC group vs. 43% and 39%, respectively, in the SAP group (mean difference −3.0% [95% CI −6.1, 0.1]; P &lt; 0.0001 for noninferiority). One severe hypoglycemic event occurred in the CLC group, which was unrelated to the study device. CONCLUSIONS In meeting its coprimary end points, superiority of CLC over SAP in CGM-measured time below 3.9 mmol/L and noninferiority in CGM-measured time above 10 mmol/L, the study has demonstrated that mobile CLC is feasible and could offer certain usability advantages over embedded systems, provided the connectivity between system components is stable.
Body Mass Index Effect on Differing Responses to Psychological Stress in Blood Glucose Dynamics in Patients With Type 1 Diabetes
Özaslan, Başak , Patek, Stephen D., Shepard, Jaclyn A. , Dassau, Eyal , Breton, Marc D. , Kudva, Yogish C. , Brown, Sue A. , Basu, Ananda , Pinsker, Jordan E. , Gonder‐Frederick, Linda , Pinsker, Jordan E , Grabman, Jesse H. , Doyle, Francis J.

Journal of Diabetes Science and Technology | February 8, 2018 | Volume: 12 | Issue: 3 | Pages: 657-664

10.1177/1932296818758103 Get It

Objective: The objective was to investigate the relationship of body mass index (BMI) to differing glycemic responses to psychological stress in patients with type 1 diabetes. Methods: Continuous blood glucose monitor (CGM) data were collected for 1 week from a total of 37 patients with BMI ranging from 21.5-39.4 kg/m 2 (mean = 28.2 ± 4.9). Patients reported daily stress levels (5-point Likert-type scale, 0 = none, 4 = extreme), physical activity, carbohydrate intake, insulin boluses and basal rates. Daily reported carbohydrates, total insulin bolus, and average blood glucose (BG from CGM) were compared among patients based on their BMI levels on days with different stress levels. In addition, daily averages of a model-based “effectiveness index” (quantifying the combined impact of insulin and carbohydrate on glucose levels) were defined and compared across stress levels to capture meal and insulin independent glycemic changes. Results: Analyses showed that patient BMI likely moderated stress related glycemic changes. Linear mixed effect model results were significant for the stress-BMI interaction on both behavioral and behavior-independent glycemic changes. Across participants, under stress, an increase was observed in daily carbohydrate intake and effectiveness index at higher BMI. There was no significant interactive effect on daily insulin or average BG. Conclusion: Findings suggest that (1) stress has both behavioral and nonbehavioral glycemic effects on T1D patients and (2) the direction and magnitude of these effects are potentially influenced by level of stress and patient BMI. Possibly responsible for these observed effects are T1D/BMI related alterations in endocrine response.