Back to Authors

Green, Jennifer Greif

0000-0002-3541-4989

Mayo Clinic

Vanderbilt University

Citations 5

Outpatient Randomized Crossover Comparison of Zone Model Predictive Control Automated Insulin Delivery with Weekly Data Driven Adaptation Versus Sensor-Augmented Pump: Results from the International Diabetes Closed-Loop Trial 4
Pinsker, Jordan E. , Dassau, Eyal , Deshpande, Sunil , Raghinaru, Dan, Buckingham, Bruce A. , Kudva, Yogish C. , Laffel, Lori M. , Church, Mei Mei , Desrochers, Hannah, Ekhlaspour, Laya , Kaur, Ravinder Jeet , Levister, Camilla, Lum, John W. , Kollman, Craig, Ambler-Osborn, Louise, Freiner, Emily , O’Malley, Grenye , Brooks, Danielle , Ogyaadu, Selassie, Plesser, Mitchell, Simha, Vinaya , Desjardins, Donna, McCrady-Spitzer, Shelly , Nolander, Lisa, Hsu, Liana, Passman, Samantha, Campos, Tiffany, Murphy, Carlos, Patibandla, Nandan, Borgman, Sarah, Arreaza-Rubín, Guillermo , Eggerman, Thomas L., Green, Neal, Belle, Steven H., Castle, Jessica R. , Legault, Laurent , Wysham, Carol , Ekhlaspour, Laya , Lum, John , Doyle, Francis J , Buckingham, Bruce , Levy, Carol J. , Shi, Dawei , Kollman, Craig , Doyle, Francis J. , Isganaitis, Elvira , Beck, Roy W. , Green, Jennifer Greif , Willi, Steven Matthew

Diabetes Technology & Therapeutics | May 12, 2022 | Volume: 24 | Issue: 9 | Pages: 635-642

10.1089/dia.2022.0084 Get It

Background: Automated insulin delivery (AID) systems have proven effective in increasing time-in-range during both clinical trials and real-world use. Further improvements in outcomes for single-hormone (insulin only) AID may be limited by suboptimal insulin delivery settings. Methods: Adults (≥18 years of age) with type 1 diabetes were randomized to either sensor-augmented pump (SAP) (inclusive of predictive low-glucose suspend) or adaptive zone model predictive control AID for 13 weeks, then crossed over to the other arm. Each week, the AID insulin delivery settings were sequentially and automatically updated by an adaptation system running on the study phone. Primary outcome was sensor glucose time-in-range 70–180 mg/dL, with noninferiority in percent time below 54 mg/dL as a hierarchical outcome. Results: Thirty-five participants completed the trial (mean age 39 ± 16 years, HbA1c at enrollment 6.9% ± 1.0%). Mean time-in-range 70–180 mg/dL was 66% with SAP versus 69% with AID (mean adjusted difference +2% [95% confidence interval: −1% to +6%], P = 0.22). Median time <70 mg/dL improved from 3.0% with SAP to 1.6% with AID (−1.5% [−2.4% to −0.5%], P = 0.002). The adaptation system decreased initial basal rates by a median of 4% (−8%, 16%) and increased initial carbohydrate ratios by a median of 45% (32%, 59%) after 13 weeks. Conclusions: Automated adaptation of insulin delivery settings with AID use did not significantly improve time-in-range in this very well-controlled population. Additional study and further refinement of the adaptation system are needed, especially in populations with differing degrees of baseline glycemic control, who may show larger benefits from adaptation.
Insulin Delivery and Glucose Variability Throughout the Menstrual Cycle on Closed Loop Control for Women with Type 1 Diabetes
O’Malley, Grenye , Raghinaru, Dan, Kudva, Yogish C. , Laffel, Lori M. , Pinsker, Jordan E. , Lum, John W. , Brown, Sue A. , Anderson, Stacey M. , Emory, Emma, Voelmle, Mary, Conshafter, Katie, Morris, Kim, Gondor-Fredrick, Linda, Mitchell, Harry, Calvo, Kayla, Wakeman, Christian, Breton, Marc D. , Ambler-Osborn, Louise, Flint, Emily, Kim, Kenny, Roethke, Lindsay, Church, Mei Mei , André, Camille , Piper, Molly, Lam, David W. , Levister, Camilla, Ogyaadu, Selassie, Lovett, Jessica, Simha, Vinaya , Dadlani, Vikash, McCrady-Spitzer, Shelly , Reid, Corey, Forlenza, Gregory P. , Slover, Robert H., Jost, Emily , Berget, Cari , Towers, Lindsey, Rossick-Solis, Alex, Ekhlaspour, Laya , Jacobson, Tali, Town, Marissa, Tabatabai, Ideen , Keller, Jordan, Salas, Evalina, Dassau, Eyal , Passman, Samantha, Campos, Tiffany, Kollman, Craig, Murphy, Carlos, Patibandla, Nandan, Borgman, Sarah, Arreaza-Rubín, Guillermo , Eggerman, Thomas L., Green, Neal, Reznik, Yves , Janicek, Robert, Gabrielson, Deanna, Belle, Steven H., Castle, Jessica R. , Legault, Laurent , Wysham, Carol , Kudva, Yogish C. , Laffel, Lori M , Pinsker, Jordan E , Lum, John , Forlenza, Gregory P , Levy, Carol J. , Kovatchev, Boris , Oliveri, Mary Clancy , Isganaitis, Elvira , Kumari, Kanchan, Wadwa, R Paul , Alonso, G. Todd , Messer, Laurel H , Buckingham, Bruce A. , Doyle, Francis J. , Beck, Roy W. , Kollman, Craig , Renard, Eric , Cobelli, Claudio , Green, Jennifer Greif , Willi, Steven Matthew

Diabetes Technology & Therapeutics | January 31, 2022 | Volume: 24 | Issue: 5 | Pages: 357-361

10.1089/dia.2021.0431 Get It

Objective: To analyze insulin delivery and glycemic metrics throughout the menstrual cycle for women with type 1 diabetes using closed loop control (CLC) insulin delivery. Methods: Menstruating women using a CLC system in a clinical trial were invited to record their menstrual cycles through a cycle-tracking application. Sixteen participants provided data for this secondary analysis over three or more complete cycles. Insulin delivery and continuous glucose monitoring (CGM) data were analyzed in relation to reported cycle phases. Results: Insulin delivery and CGM metrics remained consistent during cycle phases. Intraparticipant variability of CGM metrics and weight-based insulin delivery did not change through cycle phases. Conclusions: For this sample of menstruating women with type 1 diabetes using a CLC system, insulin delivery and glycemic metrics remained stable throughout menstrual cycle phases. Additional studies in this population are needed, particularly among women who report variable glycemic control during their cycles. Trial Registration: NCT03591354.
Patient-Reported Outcomes in a Randomized Trial of Closed-Loop Control: The Pivotal International Diabetes Closed-Loop Trial
Kudva, Yogish C. , Laffel, Lori M. , Brown, Sue A. , Raghinaru, Dan, Pinsker, Jordan E. , Ekhlaspour, Laya , Messer, Laurel H. , Kovatchev, Boris , Lum, John W. , Gonder‐Frederick, Linda , Anderson, Stacey M. , Emory, Emma, Voelmle, Mary, Conshafter, Katie, Morris, Kim, Mitchell, Harry, Calvo, Kayla, Wakeman, Christian, Breton, Marc D. , Ambler-Osborn, Louise, Flint, Emily, Kim, Kenny, Roethke, Lindsay, Church, Mei Mei , André, Camille , Piper, Molly, Lam, David W. , O’Malley, Grenye , Levister, Camilla, Ogyaadu, Selassie, Lovett, Jessica, Simha, Vinaya , Dadlani, Vikash, McCrady-Spitzer, Shelly , Reid, Corey, Forlenza, Gregory P. , Alonso, G. Todd, Slover, Robert H., Jost, Emily , Berget, Cari , Towers, Lindsey, Rossick-Solis, Alex, Buckingham, Bruce A. , Jacobson, Tali, Town, Marissa, Tabatabai, Ideen , Keller, Jordan, Salas, Evalina, Dassau, Eyal , Passman, Samantha, Campos, Tiffany, Kollman, Craig, Murphy, Carlos, Patibandla, Nandan, Borgman, Sarah, Arreaza-Rubín, Guillermo , Green, Neal, Reznik, Yves , Janicek, Robert, Gabrielson, Deanna, Belle, Steven H., Castle, Jessica R. , Legault, Laurent , Wysham, Carol , Eggerman, Thomas L., Messer, Laurel H , Lum, John , Forlenza, Gregory P , Kovatchev, Boris , Buckingham, Bruce , Levy, Carol J. , Beck, Roy W. , Oliveri, Mary Clancy , Isganaitis, Elvira , Kumari, Kanchan, Wadwa, R Paul , Doyle, Francis J. , Kollman, Craig , Renard, Eric , Cobelli, Claudio , Green, Jennifer Greif , Willi, Steven Matthew

Diabetes Technology & Therapeutics | June 11, 2021 | Volume: 23 | Issue: 10 | Pages: 673-683

10.1089/dia.2021.0089 Get It

Background: Closed-loop control (CLC) has been shown to improve glucose time in range and other glucose metrics; however, randomized trials >3 months comparing CLC with sensor-augmented pump (SAP) therapy are limited. We recently reported glucose control outcomes from the 6-month international Diabetes Closed-Loop (iDCL) trial; we now report patient-reported outcomes (PROs) in this iDCL trial. Methods: Participants were randomized 2:1 to CLC ( N = 112) versus SAP ( N = 56) and completed questionnaires, including Hypoglycemia Fear Survey, Diabetes Distress Scale (DDS), Hypoglycemia Awareness, Hypoglycemia Confidence, Hyperglycemia Avoidance, and Positive Expectancies of CLC (INSPIRE) at baseline, 3, and 6 months. CLC participants also completed Diabetes Technology Expectations and Acceptance and System Usability Scale (SUS). Results: The Hypoglycemia Fear Survey Behavior subscale improved significantly after 6 months of CLC compared with SAP. DDS did not differ except for powerless subscale scores, which worsened at 3 months in SAP. Whereas Hypoglycemia Awareness and Hyperglycemia Avoidance did not differ between groups, CLC participants showed a tendency toward improved confidence in managing hypoglycemia. The INSPIRE questionnaire showed favorable scores in the CLC group for teens and parents, with a similar trend for adults. At baseline and 6 months, CLC participants had high positive expectations for the device with Diabetes Technology Acceptance and SUS showing high benefit and low burden scores. Conclusion: CLC improved some PROs compared with SAP. Participants reported high benefit and low burden with CLC. Clinical Trial Identifier: NCT03563313.
Glycemic Outcomes of Use of CLC Versus PLGS in Type 1 Diabetes: A Randomized Controlled Trial
Brown, Sue A. , Beck, Roy W. , Raghinaru, Dan, Buckingham, Bruce A. , Laffel, Lori M. , Kudva, Yogish C. , Pinsker, Jordan E. , Dassau, Eyal , Ambler-Osborn, Louise, Anderson, Stacey M. , Church, Mei Mei , Ekhlaspour, Laya , Forlenza, Gregory P. , Levister, Camilla, Simha, Vinaya , Breton, Marc D. , Kollman, Craig, Lum, John W. , Kovatchev, Boris , Emory, Emma, Voelmle, Mary, Conshafter, Katie, Morris, Kim, Gondor-Fredrick, Linda, Mitchell, Harry, Calvo, Kayla, Wakeman, Christian, Isganaitis, Elvira , Flint, Emily, Kim, Kenny, Roethke, Lindsay, André, Camille , Piper, Molly, Lam, David W. , O’Malley, Grenye , Ogyaadu, Selassie, Lovett, Jessica, Dadlani, Vikash, McCrady-Spitzer, Shelly , Reid, Corey, Slover, Robert H., Jost, Emily , Berget, Cari , Towers, Lindsey, Rossick-Solis, Alex, Jacobson, Tali, Town, Marissa, Tabatabai, Ideen , Keller, Jordan, Salas, Evalina, Passman, Samantha, Campos, Tiffany, Murphy, Carlos, Patibandla, Nandan, Borgman, Sarah, Arreza-Rubin, Guillermo, Eggerman, Thomas L., Green, Neal, Reznik, Yves , Janicek, Robert, Gabrielson, Deanna, Belle, Steven H., Castle, Jessica R. , Legault, Laurent , Wysham, Carol , Kudva, Yogish C. , Pinsker, Jordan E , Dassau, Eyal , Doyle, Francis J , Ekhlaspour, Laya , Forlenza, Gregory P , Breton, Marc D , Lum, John , Kovatchev, Boris , Buckingham, Bruce , Beck, Roy W , Wadwa, R Paul , Levy, Carol J. , Doyle, Francis J. , Kollman, Craig , Oliveri, Mary Clancy , Kumari, Kanchan , Alonso, G. Todd , Messer, Laurel H , Renard, Eric , Cobelli, Claudio , Green, Jennifer Greif , Willi, Steven Matthew

Diabetes Care | May 30, 2020 | Volume: 43 | Issue: 8 | Pages: 1822-1828

10.2337/dc20-0124 Get It

OBJECTIVE Limited information is available about glycemic outcomes with a closed-loop control (CLC) system compared with a predictive low-glucose suspend (PLGS) system. RESEARCH DESIGN AND METHODS After 6 months of use of a CLC system in a randomized trial, 109 participants with type 1 diabetes (age range, 14–72 years; mean HbA1c, 7.1% [54 mmol/mol]) were randomly assigned to CLC (N = 54, Control-IQ) or PLGS (N = 55, Basal-IQ) groups for 3 months. The primary outcome was continuous glucose monitor (CGM)-measured time in range (TIR) for 70–180 mg/dL. Baseline CGM metrics were computed from the last 3 months of the preceding study. RESULTS All 109 participants completed the study. Mean ± SD TIR was 71.1 ± 11.2% at baseline and 67.6 ± 12.6% using intention-to-treat analysis (69.1 ± 12.2% using per-protocol analysis excluding periods of study-wide suspension of device use) over 13 weeks on CLC vs. 70.0 ± 13.6% and 60.4 ± 17.1% on PLGS (difference = 5.9%; 95% CI 3.6%, 8.3%; P &lt; 0.001). Time &gt;180 mg/dL was lower in the CLC group than PLGS group (difference = −6.0%; 95% CI −8.4%, −3.7%; P &lt; 0.001) while time &lt;54 mg/dL was similar (0.04%; 95% CI −0.05%, 0.13%; P = 0.41). HbA1c after 13 weeks was lower on CLC than PLGS (7.2% [55 mmol/mol] vs. 7.5% [56 mmol/mol], difference −0.34% [−3.7 mmol/mol]; 95% CI −0.57% [−6.2 mmol/mol], −0.11% [1.2 mmol/mol]; P = 0.0035). CONCLUSIONS Following 6 months of CLC, switching to PLGS reduced TIR and increased HbA1c toward their pre-CLC values, while hypoglycemia remained similarly reduced with both CLC and PLGS.
Health Systems Science Curricula in Undergraduate Medical Education: Identifying and Defining a Potential Curricular Framework
Gonzalo, Jed D. , Dekhtyar, Michael , Starr, Stephanie R. , Borkan, Jeffrey , Brunett, Patrick, Fancher, Tonya L. , Grethlein, Sara J., Lai, Cindy J. , Lawson, Luan , Monrad, Seetha U. , Schwartz, Mark D. , Skochelak, Susan E., Green, Jennifer Greif , O’Sullivan, Patricia , Fancher, Tonya L , Monrad, Seetha U

Academic Medicine | April 19, 2016 | Volume: 92 | Issue: 1 | Pages: 123-131

10.1097/acm.0000000000001177 Get It

Purpose The authors performed a review of 30 Accelerating Change in Medical Education full grant submissions and an analysis of the health systems science (HSS)-related curricula at the 11 grant recipient schools to develop a potential comprehensive HSS curricular framework with domains and subcategories. Method In phase 1, to identify domains, grant submissions were analyzed and coded using constant comparative analysis. In phase 2, a detailed review of all existing and planned syllabi and curriculum documents at the grantee schools was performed, and content in the core curricular domains was coded into subcategories. The lead investigators reviewed and discussed drafts of the categorization scheme, collapsed and combined domains and subcategories, and resolved disagreements via group discussion. Results Analysis yielded three types of domains: core, cross-cutting, and linking. Core domains included health care structures and processes; health care policy, economics, and management; clinical informatics and health information technology; population and public health; value-based care; and health system improvement. Cross-cutting domains included leadership and change agency; teamwork and interprofessional education; evidence-based medicine and practice; professionalism and ethics; and scholarship. One linking domain was identified: systems thinking. Conclusions This broad framework aims to build on the traditional definition of systems-based practice and highlight the need for medical and other health professions schools to better align education programs with the anticipated needs of the systems in which students will practice. HSS will require a critical investigation into existing curricula to determine the most efficient methods for integration with the basic and clinical sciences.