Objective: To analyze insulin delivery and glycemic metrics throughout the menstrual cycle for women with type 1 diabetes using closed loop control (CLC) insulin delivery. Methods: Menstruating women using a CLC system in a clinical trial were invited to record their menstrual cycles through a cycle-tracking application. Sixteen participants provided data for this secondary analysis over three or more complete cycles. Insulin delivery and continuous glucose monitoring (CGM) data were analyzed in relation to reported cycle phases. Results: Insulin delivery and CGM metrics remained consistent during cycle phases. Intraparticipant variability of CGM metrics and weight-based insulin delivery did not change through cycle phases. Conclusions: For this sample of menstruating women with type 1 diabetes using a CLC system, insulin delivery and glycemic metrics remained stable throughout menstrual cycle phases. Additional studies in this population are needed, particularly among women who report variable glycemic control during their cycles. Trial Registration: NCT03591354.
P.155: Altered T Cell Compartment in Type 1 Diabetes With End Stage Renal Disease
Background: Closed-loop control (CLC) has been shown to improve glucose time in range and other glucose metrics; however, randomized trials >3 months comparing CLC with sensor-augmented pump (SAP) therapy are limited. We recently reported glucose control outcomes from the 6-month international Diabetes Closed-Loop (iDCL) trial; we now report patient-reported outcomes (PROs) in this iDCL trial. Methods: Participants were randomized 2:1 to CLC ( N = 112) versus SAP ( N = 56) and completed questionnaires, including Hypoglycemia Fear Survey, Diabetes Distress Scale (DDS), Hypoglycemia Awareness, Hypoglycemia Confidence, Hyperglycemia Avoidance, and Positive Expectancies of CLC (INSPIRE) at baseline, 3, and 6 months. CLC participants also completed Diabetes Technology Expectations and Acceptance and System Usability Scale (SUS). Results: The Hypoglycemia Fear Survey Behavior subscale improved significantly after 6 months of CLC compared with SAP. DDS did not differ except for powerless subscale scores, which worsened at 3 months in SAP. Whereas Hypoglycemia Awareness and Hyperglycemia Avoidance did not differ between groups, CLC participants showed a tendency toward improved confidence in managing hypoglycemia. The INSPIRE questionnaire showed favorable scores in the CLC group for teens and parents, with a similar trend for adults. At baseline and 6 months, CLC participants had high positive expectations for the device with Diabetes Technology Acceptance and SUS showing high benefit and low burden scores. Conclusion: CLC improved some PROs compared with SAP. Participants reported high benefit and low burden with CLC. Clinical Trial Identifier: NCT03563313.
Closed-Loop Insulin Therapy Improves Glycemic Control in Adolescents and Young Adults: Outcomes from the International Diabetes Closed-Loop Trial
Objective: To assess the efficacy and safety of closed-loop control (CLC) insulin delivery system in adolescents and young adults with type 1 diabetes. Research Design and Methods: Prespecified subanalysis of outcomes in adolescents and young adults aged 14–24 years old with type 1 diabetes in a previously published 6-month multicenter randomized trial. Participants were randomly assigned 2:1 to CLC (Tandem Control-IQ) or sensor augmented pump (SAP, various pumps+Dexcom G6 CGM) and followed for 6 months. Results: Mean age of the 63 participants was 17 years, median type 1 diabetes duration was 7 years, and mean baseline HbA1c was 8.1%. All 63 completed the trial. Time in range (TIR) increased by 13% with CLC versus decreasing by 1% with SAP (adjusted treatment group difference = +13% [+3.1 h/day]; 95% confidence interval [CI] 9–16, P < 0.001), which largely reflected a reduction in time >180 mg/dL (adjusted difference −12% [−2.9 h/day], P < 0.001). Time <70 mg/dL decreased by 1.6% with CLC versus 0.3% with SAP (adjusted difference −0.7% [−10 min/day], 95% CI −1.0% to −0.2%, P = 0.002). CLC use averaged 89% of the time for 6 months. The mean adjusted difference in HbA1c after 6 months was 0.30% in CLC versus SAP (95% CI −0.67 to +0.08, P = 0.13). There was one diabetic ketoacidosis episode in the CLC group. Conclusions: CLC use for 6 months was substantial and associated with improved TIR and reduced hypoglycemia in adolescents and young adults with type 1 diabetes. Thus, CLC has the potential to improve glycemic outcomes in this challenging age group. The clinical trial was registered with ClinicalTrials.gov (NCT03563313).
Clinical Management and Pump Parameter Adjustment of the Control-IQ Closed-Loop Control System: Results from a 6-Month, Multicenter, Randomized Clinical Trial
Background: Data are limited on the need for and benefits of pump setting optimization with automated insulin delivery. We examined clinical management of a closed-loop control (CLC) system and its relationship to glycemic outcomes. Materials and Methods: We analyzed personal parameter adjustments in 168 participants in a 6-month multicenter trial of CLC with Control-IQ versus sensor-augmented pump (SAP) therapy. Preset parameters (BR = basal rates, CF = correction factors, CR = carbohydrate ratios) were optimized at randomization, 2 and 13 weeks, for safety issues, participant concerns, or initiation by participants' usual diabetes care team. Time in range (TIR 70–180 mg/dL) was compared in the week before and after parameter changes. Results: In 607 encounters for parameter changes, there were fewer adjustments for CLC than SAP (3.4 vs. 4.1/participant). Adjustments involved BR (CLC 69%, SAP 80%), CR (CLC 68%, SAP 50%), CF (CLC 44%, SAP 41%), and overnight parameters (CLC 62%, SAP 75%). TIR before and after adjustments was 71.2% and 71.3% for CLC and 61.0% and 62.9% for SAP. The highest baseline HbA 1c CLC subgroup had the largest TIR improvement (51.2% vs. 57.7%). When a CR was made more aggressive in the CLC group, postprandial time >180 mg/dL was 43.1% before the change and 36.0% after the change. The median postprandial time <70 mg/dL before making CR less aggressive was 1.8%, and after the change was 0.7%. Conclusions: No difference in TIR was detected with parameter changes overall, but they may have an effect in higher HbA 1c subgroups or following user-directed boluses, suggesting that changes may matter more in suboptimal control or during discrete periods of the day. Clinical Trials Registration number: NCT03563313.
Glycemic Outcomes of Use of CLC Versus PLGS in Type 1 Diabetes: A Randomized Controlled Trial
OBJECTIVE Limited information is available about glycemic outcomes with a closed-loop control (CLC) system compared with a predictive low-glucose suspend (PLGS) system. RESEARCH DESIGN AND METHODS After 6 months of use of a CLC system in a randomized trial, 109 participants with type 1 diabetes (age range, 14–72 years; mean HbA1c, 7.1% [54 mmol/mol]) were randomly assigned to CLC (N = 54, Control-IQ) or PLGS (N = 55, Basal-IQ) groups for 3 months. The primary outcome was continuous glucose monitor (CGM)-measured time in range (TIR) for 70–180 mg/dL. Baseline CGM metrics were computed from the last 3 months of the preceding study. RESULTS All 109 participants completed the study. Mean ± SD TIR was 71.1 ± 11.2% at baseline and 67.6 ± 12.6% using intention-to-treat analysis (69.1 ± 12.2% using per-protocol analysis excluding periods of study-wide suspension of device use) over 13 weeks on CLC vs. 70.0 ± 13.6% and 60.4 ± 17.1% on PLGS (difference = 5.9%; 95% CI 3.6%, 8.3%; P < 0.001). Time >180 mg/dL was lower in the CLC group than PLGS group (difference = −6.0%; 95% CI −8.4%, −3.7%; P < 0.001) while time <54 mg/dL was similar (0.04%; 95% CI −0.05%, 0.13%; P = 0.41). HbA1c after 13 weeks was lower on CLC than PLGS (7.2% [55 mmol/mol] vs. 7.5% [56 mmol/mol], difference −0.34% [−3.7 mmol/mol]; 95% CI −0.57% [−6.2 mmol/mol], −0.11% [1.2 mmol/mol]; P = 0.0035). CONCLUSIONS Following 6 months of CLC, switching to PLGS reduced TIR and increased HbA1c toward their pre-CLC values, while hypoglycemia remained similarly reduced with both CLC and PLGS.
SAT-641 Self-Reported Psychological Stress and Glucose Variability in Type 1 Diabetes on Sensor Augmented Pump over 5 Weeks
Abstract Introduction: Patients and their families and medical providers have assumed that psychologic stress impacts glucose control in T1D (Type 1 Diabetes) though studies providing confirmatory evidence in real world settings are, to our knowledge, lacking. We hypothesized that self-reported psychologic stress worsens glucose control in T1D. Method: We studied 20 adults with T1D on continuous glucose monitor (CGM), sensor augmented insulin pump (SAP) prospectively at 2 clinical research centers. Patients reported psychological stress through stress diaries for 5 weeks on a severity scale of 1-7 using hard copy logs including time of onset and offset of stress and severity. For analytic purpose, grades 1-4 are classified as mild and grades 5-7 as severe. Results: Baseline characteristics were age 44.9±15.0 years, F/M 12/8, HbA1c 6.8 ± 0.7%, and diabetes duration of 22.9±15.9 years. We analyzed glucose variability during days of stress versus days without stress. During a 24 hour period, patients experienced less hypoglycemia during days with stress versus days without stress (p value 0.03). During the 5 week period, patients reported 23 ± 19.5 events. We analyzed the impact of self-reported stress on CGM data streams after excluding stress events associated with missing CGM data, nocturnal events (from 12 MN to 6 AM, too few events) and events for which subjects did not provide duration of stress. Thus, we analyzed 19.5 ± 17 events per patient from 6AM to 12MN. From 6 AM to 12 MN, the episodes lasted 179 ± 255 minutes with 83 % episodes being mild/moderate and 17% moderate/ severe. Number of CGM readings during daytime stress episodes were 717± 1120 compared to 8768± 1238 during non-stress periods. Impact of stress from 6 AM to 12 MN (Mid-Night) on CGM glucose was analyzed using matched paired t test. Mean glucose (160.6±41.9 vs 148.3± 28.6) and SD (53.2 ±17.7 vs 56.1±14.6) did not show a difference; however % of time spent below 70 mg/dl was less (4 ± 5) in patients during stressful periods compared to times without stress (6.3± 5.5, P value 0.02). Conclusions: To our knowledge, this is the first study attempting to analyze the impact of self-reported stress using daily stress diaries on CGM data streams in T1D patients on SAP. The study revealed significant challenges experienced by patients in reporting adequate data. Self-reported stress was not associated with hyperglycemia. However, days of self-reported stress and periods during patients reported stress were characterized by less hypoglycemia on CGM data streams.
Randomized Controlled Trial of Mobile Closed-Loop Control
OBJECTIVE Assess the efficacy of inControl AP, a mobile closed-loop control (CLC) system. RESEARCH DESIGN AND METHODS This protocol, NCT02985866, is a 3-month parallel-group, multicenter, randomized unblinded trial designed to compare mobile CLC with sensor-augmented pump (SAP) therapy. Eligibility criteria were type 1 diabetes for at least 1 year, use of insulin pumps for at least 6 months, age ≥14 years, and baseline HbA1c <10.5% (91 mmol/mol). The study was designed to assess two coprimary outcomes: superiority of CLC over SAP in continuous glucose monitor (CGM)–measured time below 3.9 mmol/L and noninferiority in CGM-measured time above 10 mmol/L. RESULTS Between November 2017 and May 2018, 127 participants were randomly assigned 1:1 to CLC (n = 65) versus SAP (n = 62); 125 participants completed the study. CGM time below 3.9 mmol/L was 5.0% at baseline and 2.4% during follow-up in the CLC group vs. 4.7% and 4.0%, respectively, in the SAP group (mean difference −1.7% [95% CI −2.4, −1.0]; P < 0.0001 for superiority). CGM time above 10 mmol/L was 40% at baseline and 34% during follow-up in the CLC group vs. 43% and 39%, respectively, in the SAP group (mean difference −3.0% [95% CI −6.1, 0.1]; P < 0.0001 for noninferiority). One severe hypoglycemic event occurred in the CLC group, which was unrelated to the study device. CONCLUSIONS In meeting its coprimary end points, superiority of CLC over SAP in CGM-measured time below 3.9 mmol/L and noninferiority in CGM-measured time above 10 mmol/L, the study has demonstrated that mobile CLC is feasible and could offer certain usability advantages over embedded systems, provided the connectivity between system components is stable.
Continuous glucose monitoring to assess glycemic control in the first 6 weeks after pancreas transplantation
AbstractBackgroundCurrent therapy for Type 1 diabetes (T1D) is characterized by significant glucose variability (GV). Pancreas transplantation (PT) is performed in certain T1D patients with and without end‐stage renal disease. To date, GV has been examined to a limited extent after PT.MethodsWe investigated GV using continuous glucose monitoring (CGM) 3‐6 weeks after PT.ResultsEleven patients had simultaneous kidney pancreas transplantation (SPK), nine pancreas after kidney (PAK), and six pancreas transplantation alone (PTA). Mean CGM showed no difference between SPK, 126.5 ± 13.9, PAK 119.9 ± 12.8, and PTA 131.1 ± 29 mg/dL (P value .6). Percentage of time in range (TIR, 70‐180 mg/dL) was 92% for SPK, 93.4% in PAK, and 88.5% in PTA with only 0.3%, 1.5%, and 0.3% of time <70 mg/dL. Percentage >180 mg/dL was 7.9% for SPK, 4.9% PAK, and 11% in PTA. Other measures of GV were similar in the three cohorts. In six patients, CGM was performed before and after PT and improved significantly. GV was also better compared with a matched cohort of T1D patients.ConclusionsAll 3 types of PT resulted in excellent glucose control 3‐6 weeks post‐procedure. CGM outcomes represent an important objective outcome after PT.