Back to Authors

Emory, Emma

Mayo Clinic

University of Virginia

Citations 9

Automated Insulin Delivery Is Beneficial in Adults With Insulin-Treated Type 2 Diabetes With and Without GAD65 Antibodies
Beck, Roy W. , Hirsch, Irl B., Raghinaru, Dan, Lum, John W. , Pinsker, Jordan E. , Kudva, Yogish C. , Group*, 2IQP Study, Desjardins, Donna, Kurek, Corey, Kaur, Ravinder Jeet , Livingood, Daine, Rizvi, Shafaq , Graham, Timothy E., Terry, Adrienne, Luker, Ryan, Mellenthin, Melanie, Rezac, Stephanie, Liljenquist, David R., Rogers, Justin, Williams, Jonathan, Christensen, Rochelle, Lee, In‐Kyoung, Malone, Joann, Spanakis, Elias K. , Singh, Lakshmi G., Churchill, Jade, Comen, Kathleen, Scott, William H., Davis, Georgia M. , Arroyo, Lizda Guerrero, Oladejo, Omolade , Usman, Sabeena, Ahmann, Andrew , Schmid, Caleb, Dean, Ariel, Branigan, Deborah , Caswell, Brittany, Heyerman, Tess, Tessman, Brian, Vanderheide, Jnh, Dennis, Brittany , Hendricks, Lisa, Reyes-Rodriguez, Clemente, Wolf, Valerie, Coyne, Kasey, Kravarusic, Jelena, Fronczyk, Evelyn, Herrmann, Stefanie, Penn, Samsam C., Blevins, Thomas , Casaubon, Luis, Espinosa, Valerie, Pandit, Keta, Perez, Jennifer, Stewart, Ana, Assir, Courtney, Fields, Cory, Kruger, Davida , Estrada, Kathleen, Jones, J. Kimberly, Mukhashen, Shereen, Corker, Natalie, Hunter, Heather, Layton, Paula, Brown, Sue A. , Afreen, Samina , Dhillon, Jasmeen, Emory, Emma, Fulkerson, David, Fuller, Morgan, Holmes, Viola, Kollar, Laura, Toole, Elyse, Levister, Camilla, O’Malley, Grenye , Ipek, Aslihan, Alabi, Denise, Ellis, Emily, Hassan, Shaziah, Ogyaadu, Selassie, Tamarez, Denisa, Weinstock, Ruth S. , Stone, Sheri , Bzdick, Suzan, Agostini, Lynn, Bulger, Jane , Wolpert, Howard , Atakov-Castillo, Astrid , Sullivan, Asya, Aia, Corinne, Brouillard, Elizabeth, Driscoll, Marsha, Lapier, Heather, Payra, Sherryl, Vancer, Louise, Averkiou, Xenia, Baran, Jesica, Holod, Rosanna, Litvicov, Patrisia, Mandava, Patali, Swinton, Sydney, Khakpour, Dori , Broyles, Frances E. , Marks, Sheryl, Mitchell, Tina, Hairston, Babette, Costello, Reilly, Curtis, Stella, Kamimoto, Jorge Jo, Peleckis, Amy J. , Sultan, Rahaf , Dalton-Bakes, Cornelia, Bourne, Patricia, Haidar, Ahmad, Pasqua, Melissa, Tardio, Vanessa , Moore, Adelyn, Kemp, Gabrielle, Raskin, Philip, Jordan, L.F., Shao, Baomei, DoNguyen, Trang, Meeks, Tram, Phan, Michael , Lesniak, Amanda, Becerra, Mario, Bellini, Natalie J. , Denallo, Erica, Lewis, Claudia , Tribout, Jerry, Tribout, Megan, DiFrancesco, Kathryn, Phillips, Kylie, Raghinaru, Dan, Campos, Tiffany, Morrell, Beth, Oduah, Vanessa, Cardenas-Villamil, Gabriela, Morales, Amanda, Murphy, Carlos, Strayer, Heidi, Spanbauer, Charles , Kollman, Craig, Sasson-Katchalski, Ravid, Piquette, Nicole, Wheatcroft, Alex, WHITE, KIRSTIN N., Carmelo, KC, Janicek, Robert, Gabrielson, Deanna, Mercado, Kevin, Beck, Roy W , Group*, 2IQP Study, Smith, Joshua W. , Christensen, Rochelle, Malone, Joann, Pasquel, Francisco J. , Tajrishi, Farbod Zahedi , Arroyo, Lizda Guerrero, Dean, Ariel, Howard, Matthew, Vander-Heide, Jesse, Ahn, David , Aleppo, Grazia , Fields, Cory, Layton, Paula, Oliveri, Mary Clancy , Levy, Carol J. , Agostini, Lynn, Steenkamp, Devin W , Spaic, Tamara , Liu, Selina , Marks, Sheryl, Mitchell, Tina, Costello, Reilly, Curtis, Stella, Rickels, Michael R. , Bourne, Patricia, Tsoukas, Michael A. , Pasqua, Melissa-Rosina , Moore, Adelyn, Kemp, Gabrielle, Meeks, Tram, Phan, Michael, Hatipoğlu, Betül , Lesniak, Amanda, Howard, Quiana , DiFrancesco, Kathryn, Raghinaru, Dan, Morrell, Beth, Morales, Amanda, Kanapka, Lauren , Le, Van

Diabetes Care | December 5, 2025 | Volume: 49 | Issue: 2 | Pages: e18-e20

10.2337/dc25-2059 Get It

Adults With Type 2 Diabetes Benefit From Automated Insulin Delivery Irrespective of C-Peptide Level
Hirsch, Irl B., Kudva, Yogish C. , Blevins, Thomas , Raghinaru, Dan, Lum, John W. , Kollman, Craig, Pinsker, Jordan E. , Beck, Roy W. , Group*, 2IQP Study, Desjardins, Donna, Kurek, Corey, Kaur, Ravinder Jeet , Livingood, Daine, Rizvi, Shafaq , Graham, Timothy E., Terry, Adrienne, Luker, Ryan, Mellenthin, Melanie, Rezac, Stephanie, Liljenquist, David R., Rogers, Justin, Williams, Jonathan, Christensen, Rochelle, Lee, In‐Kyoung, Malone, Joann, Spanakis, Elias K. , Singh, Lakshmi G., Churchill, Jade, Comen, Kathleen, Scott, William H., Davis, Georgia M. , Arroyo, Lizda Guerrero, Oladejo, Omolade , Usman, Sabeena, Ahmann, Andrew , Schmid, Caleb, Dean, Ariel, Branigan, Deborah , Caswell, Brittany, Heyerman, Tess, Tessman, Brian, Vanderheide, Jnh, Dennis, Brittany , Hendricks, Lisa, Reyes-Rodriguez, Clemente, Wolf, Valerie, Coyne, Kasey, Kravarusic, Jelena, Fronczyk, Evelyn, Herrmann, Stefanie, Penn, Samsam C., Casaubon, Luis, Espinosa, Valerie, Pandit, Keta, Perez, Jennifer, Stewart, Ana, Assir, Courtney, Fields, Cory, Kruger, Davida , Estrada, Kathleen, Jones, J. Kimberly, Mukhashen, Shereen, Corker, Natalie, Hunter, Heather, Layton, Paula, Brown, Sue A. , Afreen, Samina , Dhillon, Jasmeen, Emory, Emma, Fulkerson, David, Fuller, Morgan, Holmes, Viola, Kollar, Laura, Toole, Elyse, Levister, Camilla, O’Malley, Grenye , Ipek, Aslihan, Alabi, Denise, Ellis, Emily, Hassan, Shaziah, Ogyaadu, Selassie, Tamarez, Denisa, Weinstock, Ruth S. , Stone, Sheri , Bzdick, Suzan, Agostini, Lynn, Bulger, Jane , Wolpert, Howard , Atakov-Castillo, Astrid , Sullivan, Asya, Aia, Corinne, Brouillard, Elizabeth, Driscoll, Marsha, Lapier, Heather, Payra, Sherryl, Vancer, Louise, Averkiou, Xenia, Baran, Jesica, Holod, Rosanna, Litvicov, Patrisia, Mandava, Patali, Swinton, Sydney, Khakpour, Dori , Broyles, Frances E. , Marks, Sheryl, Mitchell, Tina, Hairston, Babette, Costello, Reilly, Curtis, Stella, Rickels, Michael R., Kamimoto, Jorge Jo, Peleckis, Amy J. , Sultan, Rahaf , Dalton-Bakes, Cornelia, Bourne, Patricia, Haidar, Ahmad, Pasqua, Melissa, Tardio, Vanessa , Moore, Adelyn, Kemp, Gabrielle, Raskin, Philip, Jordan, L.F., Shao, Baomei, DoNguyen, Trang, Meeks, Tram, Phan, Michael , Lesniak, Amanda, Becerra, Mario, Denallo, Erica, Lewis, Claudia , Tribout, Jerry, Tribout, Megan, DiFrancesco, Kathryn, Phillips, Kylie, Lum, John W., Campos, Tiffany, Morrell, Beth, Oduah, Vanessa, Cardenas-Villamil, Gabriela, Morales, Amanda, Murphy, Carlos, Strayer, Heidi, Spanbauer, Charles , Kollman, Craig, Sasson-Katchalski, Ravid, Piquette, Nicole, Wheatcroft, Alex, WHITE, KIRSTIN N., Carmelo, KC, Janicek, Robert, Gabrielson, Deanna, Mercado, Kevin, Hirsch, Irl B. , Pinsker, Jordan E , Beck, Roy W , Hirsch, Irl B , Ahn, David , Rickels, Michael R. , Group*, 2IQP Study, Smith, Joshua W. , Christensen, Rochelle, Malone, Joann, Pasquel, Francisco J. , Tajrishi, Farbod Zahedi , Arroyo, Lizda Guerrero, Dean, Ariel, Howard, Matthew, Vander-Heide, Jesse, Aleppo, Grazia , Fields, Cory, Layton, Paula, Oliveri, Mary Clancy , Levy, Carol J. , Agostini, Lynn, Steenkamp, Devin W , Spaic, Tamara , Liu, Selina , Marks, Sheryl, Mitchell, Tina, Costello, Reilly, Curtis, Stella, Rickels, Michael R., Bourne, Patricia, Tsoukas, Michael A. , Pasqua, Melissa-Rosina , Moore, Adelyn, Kemp, Gabrielle, Meeks, Tram, Phan, Michael, Hatipoğlu, Betül , Lesniak, Amanda, Bellini, Natalie J. , Howard, Quiana , Lewis, Claudia, DiFrancesco, Kathryn, Lum, John W., Morrell, Beth, Morales, Amanda, Kanapka, Lauren , Kollman, Craig, Le, Hung V.

Diabetes Care | September 15, 2025 | Volume: 48 | Issue: 12 | Pages: 2061-2066

10.2337/dc25-1125 Get It

OBJECTIVE The Centers for Medicare & Medicaid Services (CMS) requires a low C-peptide level for insulin pump coverage unless the individual is β-cell autoantibody positive, which precludes coverage of automated insulin delivery (AID) systems for many people with type 2 diabetes. RESEARCH DESIGN AND METHODS In the Randomized Trial Evaluating the Efficacy and Safety of Control-IQ+ Technology in Adults With Type 2 Diabetes Using Basal-Bolus Insulin Therapy study evaluating the t:slim X2 insulin pump with Control-IQ+ technology, adults with insulin-treated type 2 diabetes were categorized into high C-peptide (n = 195) and low C-peptide (n = 59) groups based on CMS criteria. RESULTS In the AID group, mean HbA1c decreased from baseline by 0.8%, which was significantly greater than in the control group with both high (P < 0.001) and low (P = 0.02) C-peptide levels. Results were similar in participants ≥65 years old. CONCLUSIONS The benefit of AID is present with high and low C-peptide levels. Thus, requiring a low C-peptide level as a prerequisite for AID therapy is not warranted.
Insulin Delivery and Glucose Variability Throughout the Menstrual Cycle on Closed Loop Control for Women with Type 1 Diabetes
O’Malley, Grenye , Raghinaru, Dan, Kudva, Yogish C. , Laffel, Lori M. , Pinsker, Jordan E. , Lum, John W. , Brown, Sue A. , Anderson, Stacey M. , Emory, Emma, Voelmle, Mary, Conshafter, Katie, Morris, Kim, Gondor-Fredrick, Linda, Mitchell, Harry, Calvo, Kayla, Wakeman, Christian, Breton, Marc D. , Ambler-Osborn, Louise, Flint, Emily, Kim, Kenny, Roethke, Lindsay, Church, Mei Mei , André, Camille , Piper, Molly, Lam, David W. , Levister, Camilla, Ogyaadu, Selassie, Lovett, Jessica, Simha, Vinaya , Dadlani, Vikash, McCrady-Spitzer, Shelly , Reid, Corey, Forlenza, Gregory P. , Slover, Robert H., Jost, Emily , Berget, Cari , Towers, Lindsey, Rossick-Solis, Alex, Ekhlaspour, Laya , Jacobson, Tali, Town, Marissa, Tabatabai, Ideen , Keller, Jordan, Salas, Evalina, Dassau, Eyal , Passman, Samantha, Campos, Tiffany, Kollman, Craig, Murphy, Carlos, Patibandla, Nandan, Borgman, Sarah, Arreaza-Rubín, Guillermo , Eggerman, Thomas L., Green, Neal, Reznik, Yves , Janicek, Robert, Gabrielson, Deanna, Belle, Steven H., Castle, Jessica R. , Legault, Laurent , Wysham, Carol , Kudva, Yogish C. , Laffel, Lori M , Pinsker, Jordan E , Lum, John , Forlenza, Gregory P , Levy, Carol J. , Kovatchev, Boris , Oliveri, Mary Clancy , Isganaitis, Elvira , Kumari, Kanchan, Wadwa, R Paul , Alonso, G. Todd , Messer, Laurel H , Buckingham, Bruce A. , Doyle, Francis J. , Beck, Roy W. , Kollman, Craig , Renard, Eric , Cobelli, Claudio , Green, Jennifer Greif , Willi, Steven Matthew

Diabetes Technology & Therapeutics | January 31, 2022 | Volume: 24 | Issue: 5 | Pages: 357-361

10.1089/dia.2021.0431 Get It

Objective: To analyze insulin delivery and glycemic metrics throughout the menstrual cycle for women with type 1 diabetes using closed loop control (CLC) insulin delivery. Methods: Menstruating women using a CLC system in a clinical trial were invited to record their menstrual cycles through a cycle-tracking application. Sixteen participants provided data for this secondary analysis over three or more complete cycles. Insulin delivery and continuous glucose monitoring (CGM) data were analyzed in relation to reported cycle phases. Results: Insulin delivery and CGM metrics remained consistent during cycle phases. Intraparticipant variability of CGM metrics and weight-based insulin delivery did not change through cycle phases. Conclusions: For this sample of menstruating women with type 1 diabetes using a CLC system, insulin delivery and glycemic metrics remained stable throughout menstrual cycle phases. Additional studies in this population are needed, particularly among women who report variable glycemic control during their cycles. Trial Registration: NCT03591354.
Patient-Reported Outcomes in a Randomized Trial of Closed-Loop Control: The Pivotal International Diabetes Closed-Loop Trial
Kudva, Yogish C. , Laffel, Lori M. , Brown, Sue A. , Raghinaru, Dan, Pinsker, Jordan E. , Ekhlaspour, Laya , Messer, Laurel H. , Kovatchev, Boris , Lum, John W. , Gonder‐Frederick, Linda , Anderson, Stacey M. , Emory, Emma, Voelmle, Mary, Conshafter, Katie, Morris, Kim, Mitchell, Harry, Calvo, Kayla, Wakeman, Christian, Breton, Marc D. , Ambler-Osborn, Louise, Flint, Emily, Kim, Kenny, Roethke, Lindsay, Church, Mei Mei , André, Camille , Piper, Molly, Lam, David W. , O’Malley, Grenye , Levister, Camilla, Ogyaadu, Selassie, Lovett, Jessica, Simha, Vinaya , Dadlani, Vikash, McCrady-Spitzer, Shelly , Reid, Corey, Forlenza, Gregory P. , Alonso, G. Todd, Slover, Robert H., Jost, Emily , Berget, Cari , Towers, Lindsey, Rossick-Solis, Alex, Buckingham, Bruce A. , Jacobson, Tali, Town, Marissa, Tabatabai, Ideen , Keller, Jordan, Salas, Evalina, Dassau, Eyal , Passman, Samantha, Campos, Tiffany, Kollman, Craig, Murphy, Carlos, Patibandla, Nandan, Borgman, Sarah, Arreaza-Rubín, Guillermo , Green, Neal, Reznik, Yves , Janicek, Robert, Gabrielson, Deanna, Belle, Steven H., Castle, Jessica R. , Legault, Laurent , Wysham, Carol , Eggerman, Thomas L., Messer, Laurel H , Lum, John , Forlenza, Gregory P , Kovatchev, Boris , Buckingham, Bruce , Levy, Carol J. , Beck, Roy W. , Oliveri, Mary Clancy , Isganaitis, Elvira , Kumari, Kanchan, Wadwa, R Paul , Doyle, Francis J. , Kollman, Craig , Renard, Eric , Cobelli, Claudio , Green, Jennifer Greif , Willi, Steven Matthew

Diabetes Technology & Therapeutics | June 11, 2021 | Volume: 23 | Issue: 10 | Pages: 673-683

10.1089/dia.2021.0089 Get It

Background: Closed-loop control (CLC) has been shown to improve glucose time in range and other glucose metrics; however, randomized trials >3 months comparing CLC with sensor-augmented pump (SAP) therapy are limited. We recently reported glucose control outcomes from the 6-month international Diabetes Closed-Loop (iDCL) trial; we now report patient-reported outcomes (PROs) in this iDCL trial. Methods: Participants were randomized 2:1 to CLC ( N = 112) versus SAP ( N = 56) and completed questionnaires, including Hypoglycemia Fear Survey, Diabetes Distress Scale (DDS), Hypoglycemia Awareness, Hypoglycemia Confidence, Hyperglycemia Avoidance, and Positive Expectancies of CLC (INSPIRE) at baseline, 3, and 6 months. CLC participants also completed Diabetes Technology Expectations and Acceptance and System Usability Scale (SUS). Results: The Hypoglycemia Fear Survey Behavior subscale improved significantly after 6 months of CLC compared with SAP. DDS did not differ except for powerless subscale scores, which worsened at 3 months in SAP. Whereas Hypoglycemia Awareness and Hyperglycemia Avoidance did not differ between groups, CLC participants showed a tendency toward improved confidence in managing hypoglycemia. The INSPIRE questionnaire showed favorable scores in the CLC group for teens and parents, with a similar trend for adults. At baseline and 6 months, CLC participants had high positive expectations for the device with Diabetes Technology Acceptance and SUS showing high benefit and low burden scores. Conclusion: CLC improved some PROs compared with SAP. Participants reported high benefit and low burden with CLC. Clinical Trial Identifier: NCT03563313.
Closed-Loop Insulin Therapy Improves Glycemic Control in Adolescents and Young Adults: Outcomes from the International Diabetes Closed-Loop Trial
Isganaitis, Elvira , Raghinaru, Dan, Ambler-Osborn, Louise, Pinsker, Jordan E. , Buckingham, Bruce A. , Ekhlaspour, Laya , Kudva, Yogish C., Forlenza, Gregory P. , Beck, Roy W., Kollman, Craig, Lum, John W. , Brown, Sue A. , Laffel, Lori M. , Kovatchev, Boris, Anderson, Stacey, Emory, Emma, Voelmle, Mary, Conshafter, Katie, Morris, Kim, Gondor-Fredrick, Linda, Mitchell, Harry, Calvo, Kayla, Wakeman, Christian, Breton, Marc, Flint, Emily, Kim, Kenny, Roethke, Lindsay, Church, Mei Mei , André, Camille , Piper, Molly, Lam, David , O’Malley, Grenye , Levister, Camilla, Ogyaadu, Selassie, Lovett, Jessica, Simha, Vinaya , Dadlani, Vikash, McCrady-Spitzer, Shelly , Reid, Corey, Alonso, G. Todd, Slover, Robert H., Jost, Emily , Berget, Cari, Towers, Lindsey, Rossick-Solis, Alex, Jacobson, Tali, Town, Marissa, Tabatabai, Ideen , Keller, Jordan, Salas, Evalina, Dassau, Eyal , Passman, Samantha, Campos, Tiffany, Murphy, Carlos, Patibandla, Nandan, Borgman, Sarah, Arreaza-Rubín, Guillermo , Green, Neal, Laffel, Lori, Pinsker, Jordan, Doyle, Francis, Renard, Eric, Reznik, Yves , Lum, John, Janicek, Robert, Gabrielson, Deanna, Belle, Steven H., Castle, Jessica R. , Green, Jennifer , Legault, Laurent , Wysham, Carol , Eggerman, Thomas, Forlenza, Gregory P , Buckingham, Bruce , Wadwa, R Paul , Kudva, Yogish C. , Levy, Carol J. , Kollman, Craig , Kovatchev, Boris , Anderson, Stacey M. , Oliveri, Mary Clancy , Kumari, Kanchan , Messer, Laurel H , Jacobson, Tali, Doyle, Francis J. , Patibandla, Nandan, Laffel, Lori M. , Cobelli, Claudio , Beck, Roy W. , Willi, Steven Matthew

Diabetes Technology & Therapeutics | November 20, 2020 | Volume: 23 | Issue: 5 | Pages: 342-349

10.1089/dia.2020.0572 Get It

Objective: To assess the efficacy and safety of closed-loop control (CLC) insulin delivery system in adolescents and young adults with type 1 diabetes. Research Design and Methods: Prespecified subanalysis of outcomes in adolescents and young adults aged 14–24 years old with type 1 diabetes in a previously published 6-month multicenter randomized trial. Participants were randomly assigned 2:1 to CLC (Tandem Control-IQ) or sensor augmented pump (SAP, various pumps+Dexcom G6 CGM) and followed for 6 months. Results: Mean age of the 63 participants was 17 years, median type 1 diabetes duration was 7 years, and mean baseline HbA1c was 8.1%. All 63 completed the trial. Time in range (TIR) increased by 13% with CLC versus decreasing by 1% with SAP (adjusted treatment group difference = +13% [+3.1 h/day]; 95% confidence interval [CI] 9–16, P < 0.001), which largely reflected a reduction in time >180 mg/dL (adjusted difference −12% [−2.9 h/day], P < 0.001). Time <70 mg/dL decreased by 1.6% with CLC versus 0.3% with SAP (adjusted difference −0.7% [−10 min/day], 95% CI −1.0% to −0.2%, P = 0.002). CLC use averaged 89% of the time for 6 months. The mean adjusted difference in HbA1c after 6 months was 0.30% in CLC versus SAP (95% CI −0.67 to +0.08, P = 0.13). There was one diabetic ketoacidosis episode in the CLC group. Conclusions: CLC use for 6 months was substantial and associated with improved TIR and reduced hypoglycemia in adolescents and young adults with type 1 diabetes. Thus, CLC has the potential to improve glycemic outcomes in this challenging age group. The clinical trial was registered with ClinicalTrials.gov (NCT03563313).
Clinical Management and Pump Parameter Adjustment of the Control-IQ Closed-Loop Control System: Results from a 6-Month, Multicenter, Randomized Clinical Trial
O’Malley, Grenye , Messer, Laurel H. , Pinsker, Jordan E. , Forlenza, Gregory P. , Isganaitis, Elvira , Kudva, Yogish C. , Ekhlaspour, Laya , Raghinaru, Dan, Lum, John W. , Brown, Sue A. , Kovatchev, Boris, Anderson, Stacey M. , Emory, Emma, Voelmle, Mary, Conshafter, Katie, Morris, Kim, Gondor-Fredrick, Linda, Mitchell, Harry, Calvo, Kayla, Wakeman, Christian, Breton, Marc D. , Laffel, Lori M. , E.I., Ambler-Osborn, Louise, Flint, Emily, Kim, Kenny, Roethke, Lindsay, J.E.P., Church, Mei Mei , André, Camille , Piper, Molly, C.J.L., Lam, David W. , G.O., Levister, Camilla, Ogyaadu, Selassie, Lovett, Jessica, Simha, Vinaya , Dadlani, Vikash, McCrady-Spitzer, Shelly , Reid, Corey, Wadwa, R. Paul, Alonso, G. Todd, Slover, Robert H., Jost, Emily , L.H.M., Berget, Cari, Towers, Lindsey, Rossick-Solis, Alex, Buckingham, Bruce, L.E., Jacobson, Tali, Town, Marissa, Tabatabai, Ideen , Keller, Jordan, Salas, Evalina, Paulson, John A., Beck, Jan-Philipp, Passman, Samantha, Campos, Tiffany, Kollman, D.R. Craig, Murphy, Carlos, Patibandla, Nandan, Borgman, Sarah, Arreza-Rubin, Guillermo, Eggerman, Thomas L., Green, Neal, Kovatchev, Boris, Arreza-Rubin, Guillermo, J.E.P., C.J.L., Y.C.K., Wadwa, R. Paul, Reznik, Yves , Arreza-Rubin, Guillermo, Buckingham, Bruce A. , Forlenza, Gregory P , Messer, Laurel H , Buckingham, Bruce , Levy, Carol J. , Pinsker, Jordan E. , Kovatchev, Boris , Kovatchev, Boris, Oliveri, Mary Clancy , E.I., J.E.P., C.J.L., G.O., Wadwa, R Paul , Kumari, Kanchan , Wadwa, R. Paul, L.H.M., L.E., Town, Marissa, Paulson, John A., Patibandla, Nandan, Arreza-Rubin, Guillermo, Kovatchev, Boris, Arreza-Rubin, Guillermo, J.E.P., C.J.L., Y.C.K., Wadwa, R. Paul, Renard, Eric , Cobelli, Claudio , Arreza-Rubin, Guillermo

Diabetes Technology & Therapeutics | November 6, 2020 | Volume: 23 | Issue: 4 | Pages: 245-252

10.1089/dia.2020.0472 Get It

Background: Data are limited on the need for and benefits of pump setting optimization with automated insulin delivery. We examined clinical management of a closed-loop control (CLC) system and its relationship to glycemic outcomes. Materials and Methods: We analyzed personal parameter adjustments in 168 participants in a 6-month multicenter trial of CLC with Control-IQ versus sensor-augmented pump (SAP) therapy. Preset parameters (BR = basal rates, CF = correction factors, CR = carbohydrate ratios) were optimized at randomization, 2 and 13 weeks, for safety issues, participant concerns, or initiation by participants' usual diabetes care team. Time in range (TIR 70–180 mg/dL) was compared in the week before and after parameter changes. Results: In 607 encounters for parameter changes, there were fewer adjustments for CLC than SAP (3.4 vs. 4.1/participant). Adjustments involved BR (CLC 69%, SAP 80%), CR (CLC 68%, SAP 50%), CF (CLC 44%, SAP 41%), and overnight parameters (CLC 62%, SAP 75%). TIR before and after adjustments was 71.2% and 71.3% for CLC and 61.0% and 62.9% for SAP. The highest baseline HbA 1c CLC subgroup had the largest TIR improvement (51.2% vs. 57.7%). When a CR was made more aggressive in the CLC group, postprandial time >180 mg/dL was 43.1% before the change and 36.0% after the change. The median postprandial time <70 mg/dL before making CR less aggressive was 1.8%, and after the change was 0.7%. Conclusions: No difference in TIR was detected with parameter changes overall, but they may have an effect in higher HbA 1c subgroups or following user-directed boluses, suggesting that changes may matter more in suboptimal control or during discrete periods of the day. Clinical Trials Registration number: NCT03563313.
Glycemic Outcomes of Use of CLC Versus PLGS in Type 1 Diabetes: A Randomized Controlled Trial
Brown, Sue A. , Beck, Roy W. , Raghinaru, Dan, Buckingham, Bruce A. , Laffel, Lori M. , Kudva, Yogish C. , Pinsker, Jordan E. , Dassau, Eyal , Ambler-Osborn, Louise, Anderson, Stacey M. , Church, Mei Mei , Ekhlaspour, Laya , Forlenza, Gregory P. , Levister, Camilla, Simha, Vinaya , Breton, Marc D. , Kollman, Craig, Lum, John W. , Kovatchev, Boris , Emory, Emma, Voelmle, Mary, Conshafter, Katie, Morris, Kim, Gondor-Fredrick, Linda, Mitchell, Harry, Calvo, Kayla, Wakeman, Christian, Isganaitis, Elvira , Flint, Emily, Kim, Kenny, Roethke, Lindsay, André, Camille , Piper, Molly, Lam, David W. , O’Malley, Grenye , Ogyaadu, Selassie, Lovett, Jessica, Dadlani, Vikash, McCrady-Spitzer, Shelly , Reid, Corey, Slover, Robert H., Jost, Emily , Berget, Cari , Towers, Lindsey, Rossick-Solis, Alex, Jacobson, Tali, Town, Marissa, Tabatabai, Ideen , Keller, Jordan, Salas, Evalina, Passman, Samantha, Campos, Tiffany, Murphy, Carlos, Patibandla, Nandan, Borgman, Sarah, Arreza-Rubin, Guillermo, Eggerman, Thomas L., Green, Neal, Reznik, Yves , Janicek, Robert, Gabrielson, Deanna, Belle, Steven H., Castle, Jessica R. , Legault, Laurent , Wysham, Carol , Kudva, Yogish C. , Pinsker, Jordan E , Dassau, Eyal , Doyle, Francis J , Ekhlaspour, Laya , Forlenza, Gregory P , Breton, Marc D , Lum, John , Kovatchev, Boris , Buckingham, Bruce , Beck, Roy W , Wadwa, R Paul , Levy, Carol J. , Doyle, Francis J. , Kollman, Craig , Oliveri, Mary Clancy , Kumari, Kanchan , Alonso, G. Todd , Messer, Laurel H , Renard, Eric , Cobelli, Claudio , Green, Jennifer Greif , Willi, Steven Matthew

Diabetes Care | May 30, 2020 | Volume: 43 | Issue: 8 | Pages: 1822-1828

10.2337/dc20-0124 Get It

OBJECTIVE Limited information is available about glycemic outcomes with a closed-loop control (CLC) system compared with a predictive low-glucose suspend (PLGS) system. RESEARCH DESIGN AND METHODS After 6 months of use of a CLC system in a randomized trial, 109 participants with type 1 diabetes (age range, 14–72 years; mean HbA1c, 7.1% [54 mmol/mol]) were randomly assigned to CLC (N = 54, Control-IQ) or PLGS (N = 55, Basal-IQ) groups for 3 months. The primary outcome was continuous glucose monitor (CGM)-measured time in range (TIR) for 70–180 mg/dL. Baseline CGM metrics were computed from the last 3 months of the preceding study. RESULTS All 109 participants completed the study. Mean ± SD TIR was 71.1 ± 11.2% at baseline and 67.6 ± 12.6% using intention-to-treat analysis (69.1 ± 12.2% using per-protocol analysis excluding periods of study-wide suspension of device use) over 13 weeks on CLC vs. 70.0 ± 13.6% and 60.4 ± 17.1% on PLGS (difference = 5.9%; 95% CI 3.6%, 8.3%; P &lt; 0.001). Time &gt;180 mg/dL was lower in the CLC group than PLGS group (difference = −6.0%; 95% CI −8.4%, −3.7%; P &lt; 0.001) while time &lt;54 mg/dL was similar (0.04%; 95% CI −0.05%, 0.13%; P = 0.41). HbA1c after 13 weeks was lower on CLC than PLGS (7.2% [55 mmol/mol] vs. 7.5% [56 mmol/mol], difference −0.34% [−3.7 mmol/mol]; 95% CI −0.57% [−6.2 mmol/mol], −0.11% [1.2 mmol/mol]; P = 0.0035). CONCLUSIONS Following 6 months of CLC, switching to PLGS reduced TIR and increased HbA1c toward their pre-CLC values, while hypoglycemia remained similarly reduced with both CLC and PLGS.
Randomized Controlled Trial of Mobile Closed-Loop Control
Kovatchev, Boris , Anderson, Stacey M. , Raghinaru, Dan, Kudva, Yogish C. , Laffel, Lori M. , Pinsker, Jordan E. , Buckingham, Bruce A. , Doyle, Francis J. , Brown, Sue A. , Church, Mei Mei , Dadlani, Vikash, Dassau, Eyal , Ekhlaspour, Laya , Forlenza, Gregory P. , Isganaitis, Elvira , Lam, David W. , Lum, John W. , Group, iDCL Study, Emory, Emma, Voelmle, Mary, Conshafter, Katie, Morris, Kim, Mitchell, Harry, Calvo, Kayla, Wakeman, Christian, Breton, Marc D. , Ambler-Osborn, Louise, Flint, Emily, Schultz, Alan , Kim, Kenny, Church, Mei Mei, André, Camille , Lam, David W., O’Malley, Grenye , Levister, Camilla, Ogyaadu, Selassie, Simha, Vinaya , McCrady-Spitzer, Shelly , Reid, Corey, Jost, Emily , Berget, Cari , Towers, Lindsey, Buckingham, Bruce, Ekhlaspour, Laya, Hsu, Liana, Loebner, Sarah E., Doyle, Francis J., Campos, Tiffany, Passman, Samantha, Murphy, Carlos, Patibandla, Nandan, Kollman, Craig, Pinsker, Jordan E , Doyle, Francis J , Dassau, Eyal , Ekhlaspour, Laya , Forlenza, Gregory P , Lum, John , Kovatchev, Boris , Buckingham, Bruce , Levy, Carol J. , Wadwa, R Paul , Beck, Roy W. , Group, iDCL Study, Oliveri, Mary Clancy , Church, Mei Mei, Lam, David W., Messer, Laurel H , Buckingham, Bruce, Ekhlaspour, Laya, Doyle, Francis J., Kollman, Craig

Diabetes Care | January 15, 2020 | Volume: 43 | Issue: 3 | Pages: 607-615

10.2337/dc19-1310 Get It

OBJECTIVE Assess the efficacy of inControl AP, a mobile closed-loop control (CLC) system. RESEARCH DESIGN AND METHODS This protocol, NCT02985866, is a 3-month parallel-group, multicenter, randomized unblinded trial designed to compare mobile CLC with sensor-augmented pump (SAP) therapy. Eligibility criteria were type 1 diabetes for at least 1 year, use of insulin pumps for at least 6 months, age ≥14 years, and baseline HbA1c &lt;10.5% (91 mmol/mol). The study was designed to assess two coprimary outcomes: superiority of CLC over SAP in continuous glucose monitor (CGM)–measured time below 3.9 mmol/L and noninferiority in CGM-measured time above 10 mmol/L. RESULTS Between November 2017 and May 2018, 127 participants were randomly assigned 1:1 to CLC (n = 65) versus SAP (n = 62); 125 participants completed the study. CGM time below 3.9 mmol/L was 5.0% at baseline and 2.4% during follow-up in the CLC group vs. 4.7% and 4.0%, respectively, in the SAP group (mean difference −1.7% [95% CI −2.4, −1.0]; P &lt; 0.0001 for superiority). CGM time above 10 mmol/L was 40% at baseline and 34% during follow-up in the CLC group vs. 43% and 39%, respectively, in the SAP group (mean difference −3.0% [95% CI −6.1, 0.1]; P &lt; 0.0001 for noninferiority). One severe hypoglycemic event occurred in the CLC group, which was unrelated to the study device. CONCLUSIONS In meeting its coprimary end points, superiority of CLC over SAP in CGM-measured time below 3.9 mmol/L and noninferiority in CGM-measured time above 10 mmol/L, the study has demonstrated that mobile CLC is feasible and could offer certain usability advantages over embedded systems, provided the connectivity between system components is stable.
Twelve-Week 24/7 Ambulatory Artificial Pancreas With Weekly Adaptation of Insulin Delivery Settings: Effect on Hemoglobin A1c and Hypoglycemia
Dassau, Eyal , Pinsker, Jordan E. , Kudva, Yogish C. , Brown, Sue A. , Gondhalekar, Ravi , Man, Chiara Dalla , Patek, Steve, Schiavon, Michele , Dadlani, Vikash, Dasanayake, Isuru , Church, Mei Mei , Carter, Rickey E. , Bevier, Wendy C. , Huyett, Lauren M. , Hughes, Jonathan , Anderson, Stacey M. , Lv, Dayu, Schertz, Elaine, Emory, Emma, McCrady-Spitzer, Shelly , Jean, Tyler, Bradley, Paige K., Hinshaw, Ling , Sanz, Alejandro José Laguna , Basu, Ananda , Kovatchev, Boris , McCrady-Spitzer, Shelly K, Cobelli, Claudio , Doyle, Francis J , Dalla Man, Chiara , Carter, Rickey E , Kovatchev, Boris , Cobelli, Claudio , Doyle, Francis J. , Schiavon, Michele

Diabetes Care | October 14, 2017 | Volume: 40 | Issue: 12 | Pages: 1719-1726

10.2337/dc17-1188 Get It

OBJECTIVE Artificial pancreas (AP) systems are best positioned for optimal treatment of type 1 diabetes (T1D) and are currently being tested in outpatient clinical trials. Our consortium developed and tested a novel adaptive AP in an outpatient, single-arm, uncontrolled multicenter clinical trial lasting 12 weeks. RESEARCH DESIGN AND METHODS Thirty adults with T1D completed a continuous glucose monitor (CGM)-augmented 1-week sensor-augmented pump (SAP) period. After the AP was started, basal insulin delivery settings used by the AP for initialization were adapted weekly, and carbohydrate ratios were adapted every 4 weeks by an algorithm running on a cloud-based server, with automatic data upload from devices. Adaptations were reviewed by expert study clinicians and patients. The primary end point was change in hemoglobin A1c (HbA1c). Outcomes are reported adhering to consensus recommendations on reporting of AP trials. RESULTS Twenty-nine patients completed the trial. HbA1c, 7.0 ± 0.8% at the start of AP use, improved to 6.7 ± 0.6% after 12 weeks (−0.3, 95% CI −0.5 to −0.2, P &lt; 0.001). Compared with the SAP run-in, CGM time spent in the hypoglycemic range improved during the day from 5.0 to 1.9% (−3.1, 95% CI −4.1 to −2.1, P &lt; 0.001) and overnight from 4.1 to 1.1% (−3.1, 95% CI −4.2 to −1.9, P &lt; 0.001). Whereas carbohydrate ratios were adapted to a larger extent initially with minimal changes thereafter, basal insulin was adapted throughout. Approximately 10% of adaptation recommendations were manually overridden. There were no protocol-related serious adverse events. CONCLUSIONS Use of our novel adaptive AP yielded significant reductions in HbA1c and hypoglycemia.