While the triple tracer isotope dilution method has enabled accurate estimation of carbohydrate turnover after a mixed meal, use of the simple carbohydrate glucose as the carbohydrate source limits its translational applicability to everyday meals that typically contain complex carbohydrates. Hence, utilizing the natural enrichment of [13C]polysaccharide in commercially available grains, we devised a novel tracer method to measure postprandial complex carbohydrate turnover and indices of insulin action and β-cell function and compared the parameters to those obtained after a simple carbohydrate containing mixed meal. We studied healthy volunteers after either rice ( n = 8) or sorghum ( n = 8) and glucose ( n = 16) containing mixed meals and modified the triple tracer technique to calculate carbohydrate turnover. All meals were matched for calories and macronutrient composition. Rates of meal glucose appearance (2,658 ± 736 vs. 4,487 ± 909 μM·kg−1·2 h−1), endogenous glucose production (−835 ± 283 vs. −1,123 ± 323 μM·kg−1·2 h−1) and glucose disappearance (1,829 ± 807 vs. 3,606 ± 839 μM·kg−1·2 h−1) differed ( P < 0.01) between complex and simple carbohydrate containing meals, respectively. Interestingly, there were significant increase in indices of insulin sensitivity (32.5 ± 3.5 vs. 25.6 ± 3.2 10−5(dl·kg−1·min−2)/pM, P = 0.006) and β-cell responsivity (disposition index: 1,817 ± 234 vs. 1,236 ± 159 10−14(dl·kg−1·min−2)/pM, P < 0.005) with complex than simple carbohydrate meals. We present a novel triple tracer approach to estimate postprandial turnover of complex carbohydrate containing mixed meals. We also report higher insulin sensitivity and β-cell responsivity with complex than with simple carbohydrates in mixed meals of identical calorie and macronutrient compositions in healthy adults.
Twelve-Week 24/7 Ambulatory Artificial Pancreas With Weekly Adaptation of Insulin Delivery Settings: Effect on Hemoglobin A1c and Hypoglycemia
OBJECTIVE Artificial pancreas (AP) systems are best positioned for optimal treatment of type 1 diabetes (T1D) and are currently being tested in outpatient clinical trials. Our consortium developed and tested a novel adaptive AP in an outpatient, single-arm, uncontrolled multicenter clinical trial lasting 12 weeks. RESEARCH DESIGN AND METHODS Thirty adults with T1D completed a continuous glucose monitor (CGM)-augmented 1-week sensor-augmented pump (SAP) period. After the AP was started, basal insulin delivery settings used by the AP for initialization were adapted weekly, and carbohydrate ratios were adapted every 4 weeks by an algorithm running on a cloud-based server, with automatic data upload from devices. Adaptations were reviewed by expert study clinicians and patients. The primary end point was change in hemoglobin A1c (HbA1c). Outcomes are reported adhering to consensus recommendations on reporting of AP trials. RESULTS Twenty-nine patients completed the trial. HbA1c, 7.0 ± 0.8% at the start of AP use, improved to 6.7 ± 0.6% after 12 weeks (−0.3, 95% CI −0.5 to −0.2, P < 0.001). Compared with the SAP run-in, CGM time spent in the hypoglycemic range improved during the day from 5.0 to 1.9% (−3.1, 95% CI −4.1 to −2.1, P < 0.001) and overnight from 4.1 to 1.1% (−3.1, 95% CI −4.2 to −1.9, P < 0.001). Whereas carbohydrate ratios were adapted to a larger extent initially with minimal changes thereafter, basal insulin was adapted throughout. Approximately 10% of adaptation recommendations were manually overridden. There were no protocol-related serious adverse events. CONCLUSIONS Use of our novel adaptive AP yielded significant reductions in HbA1c and hypoglycemia.
Effect of Pramlintide on Postprandial Glucose Fluxes in Type 1 Diabetes
Abstract Context: Early postprandial hyperglycemia and delayed hypoglycemia remain major problems in current management of type 1 diabetes (T1D). Objective: Our objective was to investigate the effects of pramlintide, known to suppress glucagon and delay gastric emptying, on postprandial glucose fluxes in T1D. Design: This was a single-center, inpatient, randomized, crossover study. Patients: Twelve patients with T1D who completed the study were analyzed. Interventions: Subjects were studied on two occasions with or without pramlintide. Triple tracer mixed-meal method and oral minimal model were used to estimate postprandial glucose turnover and insulin sensitivity (SI). Integrated liver insulin sensitivity was calculated based on glucose turnover. Plasma glucagon and insulin were measured. Main Outcome Measure: Glucose turnover and SI were the main outcome measures. Results: With pramlintide, 2-hour postprandial glucose, insulin, glucagon, glucose turnover, and SI indices showed: plasma glucose excursions were reduced (difference in incremental area under the curve [iAUC], 444.0 mMmin, P = .0003); plasma insulin concentrations were lower (difference in iAUC, 7642.0 pMmin; P = .0099); plasma glucagon excursions were lower (difference in iAUC, 1730.6 pg/mlmin; P = .0147); meal rate of glucose appearance was lower (difference in iAUC: 1196.2 μM/kg fat free mass [FFM]; P = .0316), endogenous glucose production was not different (difference in iAUC: −105.5 μM/kg FFM; P = .5842), rate of glucose disappearance was lower (difference in iAUC: 1494.2 μM/kg FFM; P = .0083). SI and liver insulin sensitivity were not different between study visits (P > .05). Conclusions: Inhibition of glucagon and gastric emptying delaying reduced 2-hour prandial glucose excursions in T1D by delaying meal rate of glucose appearance.
Technology Use for Problem Solving in Adolescent Type 1 Diabetes
Background: Understanding the effect size, variability, and underlying physiology of the dawn phenomenon is important for next-generation closed-loop control algorithms for type 1 diabetes (T1D). Subjects and Methods: We used an iterative protocol design to study 16 subjects with T1D on individualized insulin pump therapy for two successive nights. Endogenous glucose production (EGP) rates at 3 a.m. and 7 a.m. were measured with [6,6- 2 H 2 ]glucose as a single tracer, infused from midnight to 7 a.m. in all subjects. To explore possibility of tracer recycling due to prolonged [6,6- 2 H 2 ]glucose infusion, which was highly probable after preplanned interim data analyses, we infused a second tracer, [6- 3 H]glucose, from 4 a.m. to 7 a.m. in the last seven subjects to measure EGP at 7 a.m. Results: Cortisol concentrations increased during both nights, but changes in glucagon and insulin concentration were inconsistent. Although the plasma glucose concentrations rose from midnight to 7 a.m. during both nights, EGP measured with [6,6- 2 H 2 ]glucose between 3 a.m. and 7 a.m. did not differ during Night 1 but fell in Night 2. However, EGP measured with [6- 3 H]glucose at 7 a.m. was higher than that measured with [6,6- 2 H 2 ]glucose during both nights, thereby suggesting tracer recycling probably underestimating EGP calculated at 7 a.m. with [6,6- 2 H 2 ]glucose. Likewise, EGP was higher at 7 a.m. with [6- 3 H]glucose than at 3 a.m. with [6,6- 2 H 2 ]glucose during both nights. Conclusions: The data demonstrate a consistent overnight rise in glucose concentrations through increased EGP, mediated likely by rising cortisol concentrations. The observations with the dual tracer approach imply significant tracer recycling leading to underestimation of EGP measured by longer-duration tracer infusion.
Effects of delayed gastric emptying on postprandial glucose kinetics, insulin sensitivity, and β-cell function
Controlling meal-related glucose excursions continues to be a therapeutic challenge in diabetes mellitus. Mechanistic reasons for this need to be understood better to develop appropriate therapies. To investigate delayed gastric emptying effects on postprandial glucose turnover, insulin sensitivity, and β-cell responsivity and function, as a feasibility study prior to studying patients with type 1 diabetes, we used the triple tracer technique C-peptide and oral minimal model approach in healthy subjects. A single dose of 30 μg of pramlintide administered at the start of a mixed meal was used to delay gastric emptying rates. With delayed gastric emptying rates, peak rate of meal glucose appearance was delayed, and rate of endogenous glucose production (EGP) was lower. C-peptide and oral minimal models enabled the assessments of β-cell function, insulin sensitivity, and β-cell responsivity simultaneously. Delayed gastric emptying induced by pramlintide improved total insulin sensitivity and decreased total β-cell responsivity. However, β-cell function as measured by total disposition index did not change. The improved whole body insulin sensitivity coupled with lower rate of appearance of EGP with delayed gastric emptying provides experimental proof of the importance of evaluating pramlintide in artificial endocrine pancreas approaches to reduce postprandial blood glucose variability in patients with type 1 diabetes.
Comparison of Physical Activity Sensors and Heart Rate Monitoring for Real-Time Activity Detection in Type 1 Diabetes and Control Subjects
Background: Currently, patients with type 1 diabetes decide on the amount of insulin to administer based on several factors, including current plasma glucose value, expected meal input, and physical activity (PA). One future therapeutic modality for patients with type 1 diabetes is the artificial endocrine pancreas (AEP). Incorporation of PA could enhance the efficacy of AEP significantly. We compared the main technologies used for PA quantitation. Subjects and Methods: Data were collected during inpatient studies involving healthy control subjects and type 1 diabetes. We report PA quantified from accelerometers (acceleration units [AU]) and heart rate (HR) monitors during a standardized activity protocol performed after a dinner meal at 7 p.m. from nine control subjects (four were males, 37.4±12.7 years old, body mass index of 24.8±3.8 kg/m 2 , and fasting plasma glucose of 4.71±0.63 mmol/L) and eight with type 1 diabetes (six were males, 45.2±13.4 years old, body mass index of 25.1±2.9 kg/m 2 , and fasting plasma glucose of 8.44±2.31 mmol/L). Results: The patient-to-patient variability was considerably less when examining AU compared with HR monitors. Furthermore, the exercise bouts and rest periods were more evident from the data streams when AUs were used to quantify activity. Unlike the AU, the HR measurements provided little insight for active and rest stages, and HR data required patient-specific standardizations to discern any meaningful pattern in the data. Conclusions: Our results indicated that AU provides a reliable signal in response to PA, including low-intensity activity. Correlation of this signal with continuous glucose monitoring data would be the next step before exploring inclusion as input for AEP control.
Diurnal Pattern of Insulin Action in Type 1 Diabetes
We recently demonstrated a diurnal pattern to insulin action (i.e., insulin sensitivity [SI]) in healthy individuals with higher SI at breakfast than at dinner. To determine whether such a pattern exists in type 1 diabetes, we studied 19 subjects with C-peptide–negative diabetes (HbA1c 7.1 ± 0.6%) on insulin pump therapy with normal gastric emptying. Identical mixed meals were ingested during breakfast, lunch, and dinner at 0700, 1300, and 1900 h in randomized Latin square of order on 3 consecutive days when measured daily physical activity was equal. The triple tracer technique enabled measurement of glucose fluxes. Insulin was administered according to the customary insulin:carbohydrate ratio for each participant. Although postprandial glucose excursions did not differ among meals, insulin concentration was higher (P < 0.01) and endogenous glucose production less suppressed (P < 0.049) at breakfast than at lunch. There were no differences in meal glucose appearance or in glucose disappearance between meals. Although there was no statistical difference (P = 0.34) in SI between meals in type 1 diabetic subjects, the diurnal pattern of SI taken across the three meals in its entirety differed (P = 0.016) from that of healthy subjects. Although the pattern in healthy subjects showed decreasing SI between breakfast and lunch, the reverse SI pattern was observed in type 1 diabetic subjects. The results suggest that in contrast to healthy subjects, SI diurnal pattern in type 1 diabetes is specific to the individual and cannot be extrapolated to the type 1 diabetic population as a whole, implying that artificial pancreas algorithms may need to be personalized.