Abstract Background Precise cross‐tracer harmonization of tau PET imaging is essential for comparing tau burden across different tracers and studies. Here, we evaluated the performance of the universal tau PET scale (Uniτ) in harmonizing Flortaucipir, MK6240, PI2620, and RO948 tau PET images into a universal scale. Method We assessed 485 individuals across aging and AD spectrum scanned head‐to‐head with Flortaucipir and MK6240, and a subset of 90 individuals with additional PI2620 and RO948. We generated tau PET SUVRs using the inferior cerebellar gray matter as reference with a common 8mm FWHM. We estimated Uniτ parameters on a training set ( n = 200) by fitting a smoothed hyperbolic tangent equation to the Meta‐Temporal ROI anchored in the mean SUVR of young participants and the 90th percentile from cognitively impaired individuals. We compared tau positivity on the Uniτ scale with classifications from SUVRs (mean + 3 SD from Youngs). We applied the same equation to all brain voxels to generate Uniτ 3D images. Then, we extracted mean Uniτ values for key ROIs and correlated them with ROI‐based Uniτ values to evaluate voxel‐wise estimates. Result Using tracer‐specific parameters, Uniτ harmonized Flortaucipir, MK6240, PI2620, and RO948 to the same scale, aligning values near the identity line and confirming its applicability across tau PET tracers (Figure 1). For Flortaucipir, Uniτ tau positivity matched original SUVR classifications (ground truth), with only one mismatch for MK6240 (Figure 1). Applying the Uniτ transformation to all brain voxels effectively harmonized 3D images to a common scale, reducing visual variabilities (Figure 2). Furthermore, ROI‐based estimates and those extracted from the 3D Uniτ images were identical (Figure 3). Conclusion Our results indicate that tau PET tracers can be harmonized to a common scale using a large head‐to‐head dataset. The Uniτ scale can harmonize entire 3D tau PET images, suggesting that there is no need to use pre‐established ROIs, which would constrain the analysis to a few brain regions. Uniτ is freely accessible across platforms ( www.unitau.app ) for ROI and 3D tau PET harmonization.
Effects of AD modifiable risk factors to tau‐PET tracer uptake and its association with cognitiion in early Braak stages
Abstract Background Many risk factors can contribute to the occurrence of Alzheimer`s Disease (AD). However, little is known about the impact of dementia risk factors to the uptake of tau‐PET tracers. Therefore, in this work we aim to investigate the influence of dementia risk factors and comorbidities on 18 F‐Flortaucipir (FTP) and 18 F‐MK6240 (MK) tau‐PET tracers’ uptake. Additionally, we will assess how these factors impact the association of tau‐PET and cognition. Method We accessed 436 individuals across the aging and AD spectrum (251 amyloid negative and 185 amyloid positive) from the HEAD study, with available Aβ‐PET, FTP, MK, and clinical assessments. Linear regression models corrected for age, sex, clinical diagnosis, and study site tested the association of factors with tau‐PET tracers in the medial temporal lobe (MTL). A tau‐PET × risk factor term was added to test the influence of risk factors to the association of tau with cognition. Result In amyloid‐β negative individuals, high BMI were positively associated with the uptake of both FTP and MK, whereas hearing loss were positively associated only with MK in the MTL (Figure 1A). In amyloid‐β positive individuals, high body mass index (BMI), hearing loss and sleep disorders were negatively associated with the uptake of both tau‐PET tracers in the MTL. On the other hand, hypertension showed negative association only with MK uptake (Figure 1B). Using Mini‐Mental State Examination (MMSE) scores as outcome, we observed that amyloid‐β negative individuals with high BMI showed worse cognitive performance as a function of both MK and FTP in the MTL, whereas individuals with vision impairment and hearing loss showed worse cognitive performance as a function of MK only (Figure 2A). Amyloid‐β positive individuals with hypercholesterolemia and hypertension presented worse cognitive performance as a function of both MK and FTP in the MTL (Figure 2B). Conclusion In this preliminary analysis, sleep disorders, hypertension, and high BMI were independently associated with tau‐PET tracer uptake, with the effects varying according to amyloid‐β pathology. These prevalent factors in the elderly also changed the association between tau‐PET and cognition, underscoring the need for further studies to better understand their role in modulating this relationship.
Defining tau PET positivity grey zones for MK6240 and Flortaucipir quantification
Abstract Background Tau PET measures are inherently continuous and applying dichotomized thresholds introduces conceptual and analytical idiosyncrasies. Understanding the limitations in the transition from tau‐negative to tau‐positive classifications is crucial for the effective use of these thresholds. This study aims to determine the confidence levels of tau PET thresholds of abnormality for different tau PET tracers by characterizing their "gray zone" using the universal tau PET scale (Uniτ, www.unitau.app ). Method We evaluated 485 individuals across the aging and AD spectrum from the HEAD study, with head‐to‐head scans for MK6240 and Flortaucipir. Uniτ estimates were derived from the Meta‐Temporal ROI. Tau positivity (T+) was defined as Uniτ values exceeding the mean plus 3 SD of individuals younger than 28 years ( n = 24). Two physicians independently performed a visual assessment of tau positivity for each tracer, with agreement indicating clear tau pathology (TVR+). Logistic regression was used to estimate the probability of TVR+ across Uniτ values for each tracer ( n = 189, CU elderly Aβ‐ and CI Aβ+). Individuals were classified as negative, positive, or within a "gray zone" between the most liberal T+ threshold and varying TVR+ probability thresholds (50%, 75%, 90%, 95%, and 99%). Result The Uniτ gray zone, defined as a function of TVR+ probabilities, demonstrated consistency between the two tracers, with differences observed only in the decimal range. The most liberal Uniτ threshold for T+ was 11.0 for both MK6240 and Flortaucipir, closely matching the 50% TVR+ probability threshold (11.1 for MK6240 and 11.7 for Flortaucipir). Higher TVR+ probabilities corresponded to increased Uniτ values with MK6240 and Flortaucipir showing near‐identical values between the tracers: 14.2 and 14.8 for 75%, 17.3 and 17.9 for 90%, 19.4 and 19.9 for 95%, and 24.1 and 24.6 for 99%, respectively (Figure 1). In total, 26 participants fell within the gray zone for MK6240, compared to 47 participants for Flortaucipir. Conclusion These findings highlight the potential of Uniτ to provide a standardized approach for assessing tau positivity across tracers. By combining quantitative Uniτ measures with visual assessments, we enhance the understanding of tau positivity certainty, particularly in the transition between negative and positive classifications.
Assessing Braak stage agreement between four Tau PET tracers
Abstract Background The Alzheimer's disease (AD) Braak staging is a key framework for classifying tau pathology progression in AD based on histopathological post‐mortem brain examinations. However, adapting it to PET imaging can be challenging due to differences in tracer uptake patterns and binding properties, which affect sensitivity, specificity, and regional staging. This study compares Braak staging across four tau PET tracers: Flortaucipir, MK6240, PI2620, and RO948. Methods We assessed 90 participants across the AD spectrum (46 CU, 31 MCI, 13 dementia; mean age 66.1 ± 7.8) using Aβ PET and four tau PET tracers: (Flortaucipir, MK6240, PI2620, and RO948). Braak positivity was defined based on Aβ− CU individuals (mean +2.5 SD, SUVR). To evaluate systematic bias and agreement between tracers, we computed pairwise differences at corresponding Braak stage estimates and applied the Bland‐Altman method to assess mean bias and limits of agreement. Additionally, Tau PET Braak region trajectories were modeled as functions of Aβ burden (Centiloid scale) using the Lowess method. Results Braak stage trajectories as a function of Aβ differ depending on the tracer and the sequential order of abnormality is highly variable. For instance, while for MK6240, RO948 and PI2620, Braak I is the first region to became abnormal, for Flortaucipir the earliest region to became abnormal is Braak IV (Figure 1). This variable pattern of abnormality impacts in the concordance of Braak staging between tracers with the highest Braak staging agreement resulting in concordance levels of approximately 70%. The highest levels of agreement between tracers usually happen at Braak 0 or Braak IV‐V, with intermediate stages showing very low concordance (Figure 2). The Bland‐Altman analysis identified wide limits of agreement, suggesting high variability and high tracer‐specific differences (Figure 3). On the other hand, it also identified that mean differences between tracers were small, indicating minimal systematic bias. Conclusion These preliminary findings reveal discrepancies in Braak staging when comparing Flortaucipir, MK6240, PI2620 and RO948. These findings suggest that while the tracers provide comparable stages on average, they may not be fully interchangeable in individual cases.
In vivo
detectability of tau‐PET tracers in Alzheimer’s disease
Abstract Background Tau‐PET tracers are essential for visualizing pathology in Alzheimer’s (AD). High detectability to tau is crucial for early detection and monitoring of tau deposition. This study compares the noise to dynamic range ratio (NRR) of [ 18 F]FTP, [ 18 F]MK6240, [ 18 F]PI2620, and [ 18 F]RO948, cross‐sectionally and longitudinally. Methods 460 individuals from the HEAD study (23 cognitively unimpaired (CU) young, 249 CU old and 188 cognitively impaired) underwent [ 18 F]FTP and [ 18 F]MK6240 tau‐PET scans; 94 additionally received [ 18 F]PI2620 and [ 18 F]RO948. A subset of 28 individuals (15 CU and 13 CI) underwent [ 18 F]FTP and [ 18 F]MK6240 follow‐up scans (1.5 ± 0.1 years later). Annual change was measured as [(followup‐baseline)/time between scans]. Noise was calculated as the standard deviation (SD) of CU Aβ‐ participants aged ≤65 (SD CUAβ‐≤65 ). The dynamic range was calculated as the SD across all subjects (SD range ). A lower the NRR (=SD CUAβ‐≤65 /SD range ) indicates more detectability. Analyses were performed at both region‐of‐interest and voxel‐wise levels. Results Across the whole cohort, [ 18 F]MK6240 exhibited lower NRR than [ 18 F]FTP in all regions. Voxel‐wise, differences were most pronounced in the frontal medial temporal regions (Figure 1). Within the four‐tracers subset, [ 18 F]PI2620 and [ 18 F]FTP showed the highest NRR in Braak II, followed by [ 18 F]RO948 and [ 18 F]MK6240. In Braak IV‐VI, [ 18 F]MK6240 consistently demonstrated the lowest values, followed by [ 18 F]PI2620, [ 18 F]FTP and [ 18 F]RO948. Similarly, in metatemporal‐ROI and Braak III, [ 18 F]MK6240 remained the lowest, however followed by [ 18 F]FTP, [ 18 F]PI2620 and [ 18 F]RO948 (Figure 2). Lower [ 18 F]MK6240 NRR was due to larger SD range , while [ 18 F]FTP's lower values stemmed from smaller SD CUAβ‐≤65 . Conversely, high [ 18 F]PI2620 and [ 18 F]RO948 values are driven by larger SD CUAβ‐≤65 . Longitudinal analyses further confirmed that [ 18 F]MK6240 exhibited the lowest NRR across the entire brain, including AD‐related regions, with voxel‐wise differences mainly in the temporal and parietal lobes. Conclusion Tau‐PET tracers exhibit significant variability in detectability. [ 18 F]MK6240 consistently demonstrated lower NRR, implying better detectability across all regions, cross‐sectionally and longitudinally. Despite differences in NRR, [ 18 F]FTP, [ 18 F]RO948 and [ 18 F]PI2620 followed similar pattern. These results provide insights into the differential tracer detectability, helping guide their optimal use in detecting and tracking tau pathology. Ongoing follow‐up scans will further clarify longitudinal tracer detectability and its implications for tau progression in AD.
Longitudinal progression and harmonization of tau‐PET tracers
Abstract Background Tau‐PET tracers have been used to monitor the progression of Alzheimer’s disease (AD). However, different tracers present distinct patterns of binding throughout the brain, challenging the harmonization of their findings. Leveraging the HEAD Study, the largest head‐to‐head study of tau‐PET tracers, we recently developed the Uniτ scale, which cross‐sectionally harmonizes Flortaucipir and MK6240 onto a universal tau‐PET measurement. Here, we provide a preliminary evaluation of the Uniτ scale’s longitudinal performance in HEAD and two independent cohorts. Methods We assessed 422 individuals across the AD spectrum with longitudinal tau‐PET from three cohorts: HEAD [13 cognitively unimpaired (CU), 9 cognitively impaired (CI) individuals, scanned head‐to‐head with Flortaucipir and MK6240], ADNI [74 CU, 208 CI, tracer: Flortaucipir], and TRIAD [72 CU, 46 CI, tracer: MK6240]. Standardized uptake ratios (SUVRs) were harmonized to Uniτ using the Uniτ Ecosystem ( unitau.app ). Braak I‐II and the Meta‐Temporal regions were used as regions of interest. Annual tau‐PET uptake change was calculated, and the effect size was defined as the mean annual change divided by its standard deviation. Results In HEAD, annual change in tau‐PET uptake in Braak I‐II across CU and CI was only detectable in MK6240 (Figure 1A). However, both tracers detected significant annual changes in the Meta‐Temporal ROI for CI (Figure 1B). In both ADNI (Flortaucipir) and TRIAD (MK6240), changes in tau‐PET uptake in Braak I‐II regions were not significant (Figures 2‐3A). However, across all cohorts, the Meta‐Temporal ROI consistently showed detectable annual tau‐PET increases—most pronounced among CI—leading to larger effect sizes than in Braak I‐II (Figures 1‐3B). The Uniτ harmonization did not fundamentally alter the pattern of the findings. However, in ADNI (Flortaucipir), Uniτ yielded a slightly higher effect size than SUVR in CU for both Braak I‐II and Meta‐Temporal regions. Conclusion In this large longitudinal sample, our findings confirm that Flortaucipir and MK6240 can detect tau PET changes over time likely associated with the progression of tau tangle pathology. While MK6240 appears to show greater progression in CU, both tracers progress similarly in CI. Our data also suggested that Uniτ harmonized tau PET measurements maintain the longitudinal characteristics of each tau PET tracer for use in clinical trials.
External Validation of Joint Propagation Model‐Based Tau PET CenTauR units
Abstract Background The Joint Propagation Model (JPM)‐based CenTauR scale was recently introduced to harmonize tau‐PET quantification across different radiotracers. This study examined how CenTauR harmonization enhances the comparability of tau‐PET quantification across matched cohorts using different tracers. The evaluation focused on three key aspects: (1) comparing tau‐PET positivity rates as defined by CenTauR, (2) evaluating its diagnostic accuracy for symptomatic AD, and (3) analyzing longitudinal changes in tau‐PET rates over time. Method The JPM, developed by the CPAD‐led Tau PET Harmonization Working Group (Leuzy et al., Alzheimers Dement. 2024; Figure 1A), models relationships between anchor point subjects and head‐to‐head tau‐PET SUVR data onto the CenTauR scale, providing conversion equations for multiple tracers. JPM equations were applied to [¹⁸F]flortaucipir SUVR (Meta‐temporal ROI) data from 561 cognitively impaired participants in the ADNI and OASIS‐3 studies. Using ROC analysis, we determined the CenTauR cut‐off for positivity (T+) that maximized the Youden index for discriminating between FDA‐approved positive/negative visual reads. Three separate cohorts, scanned using [¹⁸F]flortaucipir (ADNI), [¹⁸F]MK‐6240 (CPAS), and [¹⁸F]RO‐948 (BioFINDER‐2), were matched 1:1 by age, MMSE, amyloid‐β, and clinical diagnosis. CenTauR‐based metrics were compared across these cohorts. Result A cut‐off of 18 CenTauRs was found to optimally classify [ 18 F]flortaucipir PET visual reads (Figure 1B). The matching procedure identified 1089 participants (363 per cohort). The frequency of T+ using the 18 CenTauRs cut‐off for the Meta‐Temporal ROI was highly comparable across tracers across groups, except for the Aβ‐positive cognitively unimpaired group, where variability was more pronounced due to a smaller sample size (Figure 2A). Similarly, tau‐PET discriminative accuracy for symptomatic AD vs controls remained similar across [ 18 F]flortaucipir and [ 18 F]MK‐6240 (Figure 2B). In a separate sample of 212 matched participants from ADNI ([¹⁸F]flortaucipir) and AIBL ([¹⁸F]MK‐6240) with baseline and 1‐year follow‐up tau‐PET scans, 1‐year change in CenTauRs was comparable (Figure 2C). An exploratory voxelwise transformation, utilizing the Meta‐Temporal conversion equation in a representative case scanned with both [¹⁸F]flortaucipir and [¹⁸F]MK‐6240, demonstrates the potential for voxelwise CenTauR harmonization (Figure 3). Conclusion These analyses suggest that CenTauR harmonization increases the comparability of tau‐PET data acquired with different tracers. Additional validation analyses with larger cohorts including other radiotracers ([¹⁸F]PI‐2620) are underway.
Plasma Phosphorylated Tau 217 to Identify Preclinical Alzheimer Disease
Importance Advances in Alzheimer disease (AD) have shifted research focus to earlier disease stages, necessitating more scalable approaches to identify cognitively unimpaired individuals with amyloid β (Aβ) pathology. Objective To assess the utility of plasma phosphorylated tau 217 (p-tau217) for classifying Aβ status in cognitively unimpaired individuals, both as a stand-alone test and in a 2-step approach where positive plasma results were confirmed using a second modality (Aβ positron emission tomography [PET] or cerebrospinal fluid [CSF]). Design, Setting, and Participants This cross-sectional cohort study used data collected between June 2009 and March 2024. We included 2916 cognitively unimpaired participants from 12 international independent observational cohorts in the US, Europe, Australia, and Canada with available plasma p-tau217 levels and CSF or PET Aβ biomarkers. Performance comparisons between mass spectrometry and immunoassay-based p-tau217 measurements were also performed (n = 964). Exposures Plasma p-tau217 levels measured by immunoassay. Main Outcome and Measures Aβ status, determined by CSF or Aβ PET biomarkers. Results Participants had a mean (SD) age of 66.9 (9.9) years; 971 (33.3%) were Aβ positive by either CSF or PET, 1667 (57.2%) were women, and 1108 (38.1%) carried at least 1 APOE ε4 allele. As a stand-alone test, plasma p-tau217 achieved a positive predictive value (PPV) of 79% (95% CI, 74-84) and an overall accuracy of 81% (95% CI, 80-82). In a 2-step workflow, the PPV and accuracy significantly increased to 91% (95% CI, 86-95). While this approach required screening of 677 individuals with plasma p-tau217 to identify 100 Aβ-positive individuals, compared to 536 participants when using PET alone, it reduced the need for PET testing to 124. Immunoassays demonstrated comparable PPVs to mass spectrometry (80% [95% CI, 74-86] vs 85% [95% CI, 81-90]; P = .12) but significantly lower overall accuracy (82% [95% CI, 79-84]% vs 88 [95% CI, 86-90]; P < .001) and true Aβ-positive detection rate (49% [95% CI, 43-55] vs 69% [95% CI, 64-75]; P < .001). Conclusions and Relevance The findings highlight the potential of plasma p-tau217 as a stand-alone test—or when used in a sequential 2-step approach alongside PET or CSF testing—as a cost-effective, scalable, and minimally burdensome strategy for identifying preclinical AD. Tailored screening workflows that incorporate p-tau217 can improve efficiency in participant selection for preclinical AD trials and, in the future, help guide access to disease-modifying treatments.
Connectivity as a universal predictor of tau progression in atypical Alzheimer’s disease
Abstract The link between regional tau load and clinical manifestation of Alzheimer’s disease (AD) highlights the importance of characterizing spatial tau distribution across disease variants. In typical (memory-predominant) AD, the spatial progression of tau pathology mirrors the functional connections from temporal lobe epicentres. However, given the limited spatial heterogeneity of tau in typical AD, atypical (non-amnestic-predominant) AD variants with distinct tau patterns provide a key opportunity to investigate the universality of connectivity as a scaffold for tau progression. In this large-scale, multicentre study across 14 international sites, we included cross-sectional tau-PET data from 320 individuals with atypical AD (n = 139 posterior cortical atrophy/PCA-AD; n = 103 logopenic variant primary progressive aphasia/lvPPA-AD; n = 35 behavioural variant AD/bvAD; n = 43 corticobasal syndrome/CBS-AD), with a subset of individuals (n = 78) having longitudinal tau-PET data. Additionally, as an independent sample, we included regional post-mortem tau stainings from 93 atypical AD patients from two sites (n = 19 PCA-AD, n = 32 lvPPA-AD, n = 23 bvAD, n = 19 CBS-AD). Gaussian mixture modelling was used to harmonize different tau-PET tracers by transforming tau-PET standardized uptake value ratios to tau positivity probabilities (a uniform scale ranging from 0% to 100%). Using linear regression, we assessed whether brain regions with stronger resting-state functional MRI-based functional connectivity, derived from healthy elderly controls in the Alzheimer’s Disease Neuroimaging Initiative (ADNI), showed greater covariance in cross-sectional and longitudinal tau-PET and post-mortem tau pathology. Furthermore, we examined whether functional connectivity of tau-PET epicentres (i.e. the top 5% of regions with the highest baseline tau load) and tau-PET accumulation epicentres (i.e. the top 5% of regions with the highest tau accumulation rates) was associated with cross-sectional and longitudinal tau patterns. Our findings show that tau-PET epicentres aligned with clinical variants, e.g. a visual network predominant pattern in PCA-AD (‘visual AD’) and left-hemispheric temporal predominance, particularly within the language network, in lvPPA-AD (‘language AD’). Moreover, more strongly functionally connected regions showed correlated concurrent tau-PET levels (confirmed with post-mortem data) and tau-PET accumulation rates. The functional connectivity profile of tau-PET epicentres and accumulation epicentres corresponded to tau-PET progression patterns, with higher tau-PET levels and accumulation rates in functionally close regions, and lower tau-PET levels and accumulation rates in functionally distant regions. Our data are consistent with the hypothesis that tau propagation occurs along functional connections originating from local epicentres, across all AD clinical variants. Since tau proteinopathy is a major driver of neurodegeneration and cognitive decline, this finding may advance personalized medicine and participant-specific end points in clinical trials.
Frequency and Clinical Outcomes Associated With Tau Positron Emission Tomography Positivity
Importance Tau positron emission tomography (PET) allows in vivo detection of neurofibrillary tangles, a core neuropathologic feature of Alzheimer disease (AD). Objective To provide estimates of the frequency of tau PET positivity and its associated risk of clinical outcomes. Design, Setting, and Participants Longitudinal study using data pooled from 21 cohorts, comprising a convenience sample of 6514 participants from 13 countries, collected between January 2013 and June 2024. Cognitively unimpaired individuals and patients with a clinical diagnosis of mild cognitive impairment (MCI), AD dementia, or other neurodegenerative disorders were included. Exposures Tau PET with flortaucipir F 18, amyloid-β (Aβ) PET, and clinical examinations. Tau PET scans were visually rated as positive according to a US Food and Drug Administration– and European Medicines Agency–approved method, designed to indicate the presence of advanced neurofibrillary tangle pathology (Braak stages V-VI). Main Outcomes and Measures Frequency of tau PET positivity and absolute risk of clinical progression (eg, progression to MCI or dementia). Results Among the 6514 participants (mean age, 69.5 years; 50.5% female), median follow-up time ranged from 1.5 to 4.0 years. Of 3487 cognitively unimpaired participants, 349 (9.8%) were tau PET positive; the estimated frequency of tau PET positivity was less than 1% in those aged younger than 50 years, and increased from 3% (95% CI, 2%-4%) at 60 years to 19% (95% CI, 16%-24%) at 90 years. Tau PET positivity frequency estimates increased across MCI and AD dementia clinical diagnoses (43% [95% CI, 41%-46%] and 79% [95% CI, 77%-82%] at 75 years, respectively). Most tau PET–positive individuals (92%) were also Aβ PET positive. Cognitively unimpaired participants who were positive for both Aβ PET and tau PET had a higher absolute risk of progression to MCI or dementia over the following 5 years (57% [95% CI, 45%-71%]) compared with both Aβ PET–positive/tau PET–negative (17% [95% CI, 13%-22%]) and Aβ PET–negative/tau PET–negative (6% [95% CI, 5%-8%]) individuals. Among participants with MCI at the time of the tau PET scan, an Aβ PET–positive/tau PET–positive profile was associated with a 5-year absolute risk of progression to dementia of 70% (95% CI, 59%-81%). Conclusions and Relevance In a large convenience sample, a positive tau PET scan occurred at a nonnegligible rate among cognitively unimpaired individuals, and the combination of Aβ PET positivity and tau PET positivity was associated with a high risk of clinical progression in both preclinical and symptomatic stages of AD. These findings underscore the potential of tau PET as a biomarker for staging AD pathology.