Back to Authors

Iaccarino, Leonardo

Mayo Clinic

Eli Lilly (United States)

Citations 3

External Validation of Joint Propagation Model‐Based Tau PET CenTauR units
Leuzy, Antoine , Raket, Lars Lau, Villemagne, Victor L., Klein, Gregory , Tonietto, Matteo, Olafson, Emily, Baker, Suzanne L. , Saad, Ziad S., Bullich, Santiago , Lopresti, Brian J. , Sanabria, Sandra , Boada, Mercè, Charil, A., Collins, Emily C., Collins, Jessica, Higuchi, Makoto, Hostetler, Eric D., Hutchison, R. Matthew, Iaccarino, Leonardo, Insel, Philip S., Irizarry, Michael C., Jack, Clifford R., Jagust, William J., Johnson, Keith A., Johnson, Sterling C., Karten, Yashmin, Marquié, Marta, Mathotaarachchi, Sulantha , Mintun, Mark A., Huang, Qi, Mao, Xiaxie, Gnörich, Johannes , Pappas, Ioannis, Petersen, Ronald, Chiotis, Konstantinos, Rabinovici, Gil D., Rosa‐Neto, Pedro, Schwarz, Christopher G, Smith, Ruben, Stephens, Andrew W., Whittington, Alex , Carrillo, M., Pontecorvo, Michael J. , Haeberlein, Samantha Budd , Dunn, Billy , Stephenson, Diane , Tatton, Nadine , Brendel, Matthias, Xie, Fang, Hansson, Oskar H., Rial, Alexis Moscoso , Rakêt, Lars Lau , Villemagne, Victor L. , Tonietto, Mattéo , Olafson, Emily, Lutz, Olivia , Boada, Merce , Betthauser, Tobey J. , Collins, Emily C. , Collins, Jessica, Gunn, Roger N. , Higuchi, Makoto, Hutchison, R. Matthew , Iaccarino, Leonardo , Insel, Philip S. , Irizarry, Michael C. , Jack, Clifford R. , Jagust, William J. , Johnson, Keith A. , Johnson, Sterling C. , Marquié, Marta , Ossenkoppele, Rik , Pappas, Ioannis , Petersen, Ronald C. , Chiotis, Konstantinos , Rabinovici, Gil D. , Rosa-Neto, Pedro , Schwarz, Christopher G. , Smith, Ruben, Stephens, Andrew W., Carrillo, María C. , Kolb, Hartmuth C. , Brendel, Matthias , Xie, Fang , Rowe, Christopher Cleon , Hansson, Oskar , Doré, Vincent

Alzheimer's & Dementia | January 8, 2026 | Volume: 21 | Issue: S2 | Pages: No page available

10.1002/alz70856_106362 Get It

Abstract Background The Joint Propagation Model (JPM)‐based CenTauR scale was recently introduced to harmonize tau‐PET quantification across different radiotracers. This study examined how CenTauR harmonization enhances the comparability of tau‐PET quantification across matched cohorts using different tracers. The evaluation focused on three key aspects: (1) comparing tau‐PET positivity rates as defined by CenTauR, (2) evaluating its diagnostic accuracy for symptomatic AD, and (3) analyzing longitudinal changes in tau‐PET rates over time. Method The JPM, developed by the CPAD‐led Tau PET Harmonization Working Group (Leuzy et al., Alzheimers Dement. 2024; Figure 1A), models relationships between anchor point subjects and head‐to‐head tau‐PET SUVR data onto the CenTauR scale, providing conversion equations for multiple tracers. JPM equations were applied to [ 18 F]flortaucipir SUVR (Meta‐temporal ROI) data from 561 cognitively impaired participants in the ADNI and OASIS‐3 studies. Using ROC analysis, we determined the CenTauR cut‐off for positivity (T+) that maximized the Youden index for discriminating between FDA‐approved positive/negative visual reads. Three separate cohorts, scanned using [ 18 F]flortaucipir (ADNI), [ 18 F]MK‐6240 (CPAS), and [ 18 F]RO‐948 (BioFINDER‐2), were matched 1:1 by age, MMSE, amyloid‐β, and clinical diagnosis. CenTauR‐based metrics were compared across these cohorts. Result A cut‐off of 18 CenTauRs was found to optimally classify [ 18 F]flortaucipir PET visual reads (Figure 1B). The matching procedure identified 1089 participants (363 per cohort). The frequency of T+ using the 18 CenTauRs cut‐off for the Meta‐Temporal ROI was highly comparable across tracers across groups, except for the Aβ‐positive cognitively unimpaired group, where variability was more pronounced due to a smaller sample size (Figure 2A). Similarly, tau‐PET discriminative accuracy for symptomatic AD vs controls remained similar across [ 18 F]flortaucipir and [ 18 F]MK‐6240 (Figure 2B). In a separate sample of 212 matched participants from ADNI ([ 18 F]flortaucipir) and AIBL ([ 18 F]MK‐6240) with baseline and 1‐year follow‐up tau‐PET scans, 1‐year change in CenTauRs was comparable (Figure 2C). An exploratory voxelwise transformation, utilizing the Meta‐Temporal conversion equation in a representative case scanned with both [ 18 F]flortaucipir and [ 18 F]MK‐6240, demonstrates the potential for voxelwise CenTauR harmonization (Figure 3). Conclusion These analyses suggest that CenTauR harmonization increases the comparability of tau‐PET data acquired with different tracers. Additional validation analyses with larger cohorts including other radiotracers ([ 18 F]PI‐2620) are underway.
External Validation of Joint Propagation Model‐Based Tau PET CenTauR units
Leuzy, Antoine , Raket, Lars Lau, Villemagne, Victor L., Klein, Gregory , Tonietto, Matteo, Olafson, Emily, Baker, Suzanne L. , Saad, Ziad S., Bullich, Santiago , Lopresti, Brian J. , Sanabria, Sandra , Boada, Mercè, Charil, A., Collins, Emily C., Collins, Jessica, Gunn, Roger N. , Higuchi, Makoto, Hostetler, Eric D., Hutchison, R. Matthew, Iaccarino, Leonardo, Insel, Philip S., Irizarry, Michael C., Jack, C. R., Jagust, William J., Johnson, Keith A., Johnson, Sterling C., Karten, Yashmin, Marquié, Marta, Mathotaarachchi, Sulantha , Mintun, Mark A., Huang, Q., Mao, Xiaxie, Gnörich, Johannes , Pappas, Ioannis, Petersen, Ronald, Schwarz, Christopher G, Smith, Ruben, Stephens, Andrew , Whittington, Alex , Carrillo, Maria, Pontecorvo, Michael J. , Haeberlein, Samantha Budd , Dunn, Billy , Kolb, H., Stephenson, Diane , Tatton, Nadine , Brendel, M., Xie, Fang, Hansson, Oskar H., Rial, Alexis Moscoso , Rakêt, Lars Lau , Villemagne, Victor L. , Tonietto, Mattéo , Olafson, Emily, Lutz, Olivia , Boada, Merce , Betthauser, Tobey J. , Collins, Emily C. , Higuchi, Makoto, Hutchison, R. Matthew , Iaccarino, Leonardo , Insel, Philip S. , Irizarry, Michael C. , Jack, Clifford R. , Jagust, William J. , Johnson, Keith A. , Johnson, Sterling C. , Marquié, Marta , Ossenkoppele, Rik , Pappas, Ioannis , Petersen, Ronald, Chiotis, Konstantinos , Rabinovici, Gil D. , Rosa-Neto, Pedro , Schwarz, Christopher G. , Kolb, Hartmuth C. , Brendel, Matthias , Rowe, Christopher Cleon , Hansson, Oskar , Doré, Vincent

Alzheimer's & Dementia | December 23, 2025 | Volume: 21 | Issue: S8 | Pages: No page available

10.1002/alz70862_109722 Get It

Abstract Background The Joint Propagation Model (JPM)‐based CenTauR scale was recently introduced to harmonize tau‐PET quantification across different radiotracers. This study examined how CenTauR harmonization enhances the comparability of tau‐PET quantification across matched cohorts using different tracers. The evaluation focused on three key aspects: (1) comparing tau‐PET positivity rates as defined by CenTauR, (2) evaluating its diagnostic accuracy for symptomatic AD, and (3) analyzing longitudinal changes in tau‐PET rates over time. Method The JPM, developed by the CPAD‐led Tau PET Harmonization Working Group (Leuzy et al., Alzheimers Dement. 2024; Figure 1A), models relationships between anchor point subjects and head‐to‐head tau‐PET SUVR data onto the CenTauR scale, providing conversion equations for multiple tracers. JPM equations were applied to [¹⁸F]flortaucipir SUVR (Meta‐temporal ROI) data from 561 cognitively impaired participants in the ADNI and OASIS‐3 studies. Using ROC analysis, we determined the CenTauR cut‐off for positivity (T+) that maximized the Youden index for discriminating between FDA‐approved positive/negative visual reads. Three separate cohorts, scanned using [¹⁸F]flortaucipir (ADNI), [¹⁸F]MK‐6240 (CPAS), and [¹⁸F]RO‐948 (BioFINDER‐2), were matched 1:1 by age, MMSE, amyloid‐β, and clinical diagnosis. CenTauR‐based metrics were compared across these cohorts. Result A cut‐off of 18 CenTauRs was found to optimally classify [ 18 F]flortaucipir PET visual reads (Figure 1B). The matching procedure identified 1089 participants (363 per cohort). The frequency of T+ using the 18 CenTauRs cut‐off for the Meta‐Temporal ROI was highly comparable across tracers across groups, except for the Aβ‐positive cognitively unimpaired group, where variability was more pronounced due to a smaller sample size (Figure 2A). Similarly, tau‐PET discriminative accuracy for symptomatic AD vs controls remained similar across [ 18 F]flortaucipir and [ 18 F]MK‐6240 (Figure 2B). In a separate sample of 212 matched participants from ADNI ([¹⁸F]flortaucipir) and AIBL ([¹⁸F]MK‐6240) with baseline and 1‐year follow‐up tau‐PET scans, 1‐year change in CenTauRs was comparable (Figure 2C). An exploratory voxelwise transformation, utilizing the Meta‐Temporal conversion equation in a representative case scanned with both [¹⁸F]flortaucipir and [¹⁸F]MK‐6240, demonstrates the potential for voxelwise CenTauR harmonization (Figure 3). Conclusion These analyses suggest that CenTauR harmonization increases the comparability of tau‐PET data acquired with different tracers. Additional validation analyses with larger cohorts including other radiotracers ([¹⁸F]PI‐2620) are underway.
[18F]PI‐2620 PET in four‐repeat tauopathies: a preliminary study
Soleimani‐Meigooni, David N. , Thomas, Wesley P. , Vento, Stephanie , Heuer, Hilary W. , Ljubenkov, Peter A. , Chen, Miranda , Iaccarino, Leonardo, Pantelyat, Alex, Baker, Suzanne L. , Boxer, Adam L. , Brendel, Matthias , Rojas, Julio C. , Iaccarino, Leonardo , Joie, Renaud La , Mundada, Nidhi S. , Boeve, Bradley F. , Grossman, Murray , Dickerson, Bradford Clark , Irwin, David J. , Litvan, Irene , Tartaglia, Maria Carmela , Rabinovici, Gil D.

Alzheimer's & Dementia | December 20, 2022 | Volume: 18 | Issue: S6 | Pages: No page available

10.1002/alz.067974 Get It

AbstractBackgroundThere is a critical need for tau PET radiotracers that accurately detect non‐Alzheimer’s disease (AD) tau pathology. We aim to evaluate [18F]PI‐2620 PET tracer retention in patients with non‐AD, 4R tau‐related clinical syndromes, including progressive supranuclear palsy (PSP) with Richardson’s syndrome (PSP‐RS) and with predominant parkinsonism (PSP‐P), corticobasal syndrome (CBS), and nonfluent/agrammatic variant of primary progressive aphasia (nfvPPA).Method38 participants underwent amyloid and [18F]PI‐2620 PET (Table 1). 5 mCi ± 10% of [18F]PI‐2620 was administered. [18F]PI‐2620 PET SUVR images were generated using an inferior cerebellar gray matter reference from PET data acquired 30‐60 minutes post‐injection. Mean SUVR values were extracted from each participant in neuroanatomical structures that have elevated tau burden in PSP and CBS due to corticobasal degeneration (regions of interest in Table 2). Comparison between each diagnostic group and healthy controls (HCs) was performed using a one‐tailed, independent‐samples t‐test. Spearman correlation was used to evaluate the relationship between tracer binding (SUVR) and disease severity (PSP rating scale) in patients with PSP‐RS.ResultPatients with PSP‐RS had increased tracer retention in the left globus pallidus internus and externus, left subthalamic nucleus, and left dorsolateral prefrontal cortex compared to HCs (all p < 0.05). CBS and nfvPPA patients did not have increased tracer retention at any ROIs compared to HCs, but there were low numbers of patients in these groups (Table 2, Figures 1‐3). PSP rating scale values did not correlate with tracer binding in PSP‐RS (no correlations in any regions, rs < 0.44, p > 0.05 uncorrected).Conclusion[18F]PI‐2620 PET 30‐60 minute SUVR images may have limited ability to distinguish PSP from HCs, especially on visual read, and tracer uptake did not correlate with PSP disease severity. Other post‐injection PET acquisition windows (e.g., 30‐40 minute SUVR, 0‐60 minute DVR) will be evaluated to determine if they can maximize differences between PSP and HCs. A limitation of this preliminary study is the modest number of patients and controls, with most controls provided from a different study. Additional participants are being scanned in the multicenter 4RTNI study to understand the utility of this tracer as a neuroimaging biomarker for 4R tauopathies.