Importance Amyloid positron emission tomography (PET) is increasingly used in research and clinical settings to determine the etiology of cognitive decline and eligibility for amyloid-targeting therapies. To assist with amyloid PET evaluation and to guide clinical decision-making, images can be quantified in a standardized unit called Centiloid, the interpretation of which can vary according to the method and threshold used. Objective To collect Centiloid values from available studies and determine robust positivity cutoffs using data-driven methods and correspondence with visual reads. Data Sources PubMed search (October 2024) identified studies with Centiloid values. Corresponding authors were invited to share individual participant data. Additional data were obtained through access-controlled repositories and conference outreach (July 2024-July 2025). Study Selection Studies were included if they provided Centiloids, radiotracer, age, and sex. Data Extraction and Synthesis Each study was analyzed using a unified statistical pipeline; study estimates were pooled using random-effects meta-analysis. Main Outcomes and Measures Gaussian mixture models (GMMs) were fitted to Centiloid values for each study. In studies with a bimodal distribution (per integrated completed likelihood), single cutoffs for positivity were set as mean plus 2 SDs of the lower gaussian component. Using GMMs, a double-cutoff approach defined a lower certainty range using a 90% posterior probability cutoff for assignment to the low (amyloid-negative) vs high (amyloid-positive) component. An alternative Centiloid cutoff was derived from maximizing the correspondence (Cohen κ) with the binary visual reads when available. Results This meta-analysis included cross-sectional amyloid PET scans acquired with 5 radiotracers from 49 227 participants across 53 studies from 15 countries (mean age, 71 years; 54% female, 62% cognitively impaired). The data-driven GMM approach identified a bimodal distribution in 51 studies (n = 48 786), resulting in a single cutoff for positivity of 18 Centiloids (95% CI,16-19; I 2 = 97%). The double-cutoff approach revealed high confidence for interpreting scans as negative when Centiloid values were lower than 11 (95% CI, 9-13; I 2 = 95%) and interpreting scans as positive if Centiloid values were higher than 26 (95% CI, 24-28; I 2 = 95%). In analyses of correspondence with binary (positive or negative) visual reads of amyloid PET scans (n = 35 045; 36 studies), Centiloids were highly predictive of visual positivity (Cohen κ, 0.86; 95% CI, 0.83-0.89; I 2 = 96%) with a cutoff of 27 Centiloids (95% CI, 24-30; I 2 = 80%). Conclusions and Relevance In this individual participant data meta-analysis, positivity cutoffs converged around 18 Centiloids (data-driven) and 27 Centiloids (visual reads). Findings from a double-cutoff analysis suggest that scans in the 11 to 26 Centiloid range should be interpreted with caution depending on the context of use.
External Validation of Joint Propagation Model‐Based Tau PET CenTauR units
Abstract Background The Joint Propagation Model (JPM)‐based CenTauR scale was recently introduced to harmonize tau‐PET quantification across different radiotracers. This study examined how CenTauR harmonization enhances the comparability of tau‐PET quantification across matched cohorts using different tracers. The evaluation focused on three key aspects: (1) comparing tau‐PET positivity rates as defined by CenTauR, (2) evaluating its diagnostic accuracy for symptomatic AD, and (3) analyzing longitudinal changes in tau‐PET rates over time. Method The JPM, developed by the CPAD‐led Tau PET Harmonization Working Group (Leuzy et al., Alzheimers Dement. 2024; Figure 1A), models relationships between anchor point subjects and head‐to‐head tau‐PET SUVR data onto the CenTauR scale, providing conversion equations for multiple tracers. JPM equations were applied to [ 18 F]flortaucipir SUVR (Meta‐temporal ROI) data from 561 cognitively impaired participants in the ADNI and OASIS‐3 studies. Using ROC analysis, we determined the CenTauR cut‐off for positivity (T+) that maximized the Youden index for discriminating between FDA‐approved positive/negative visual reads. Three separate cohorts, scanned using [ 18 F]flortaucipir (ADNI), [ 18 F]MK‐6240 (CPAS), and [ 18 F]RO‐948 (BioFINDER‐2), were matched 1:1 by age, MMSE, amyloid‐β, and clinical diagnosis. CenTauR‐based metrics were compared across these cohorts. Result A cut‐off of 18 CenTauRs was found to optimally classify [ 18 F]flortaucipir PET visual reads (Figure 1B). The matching procedure identified 1089 participants (363 per cohort). The frequency of T+ using the 18 CenTauRs cut‐off for the Meta‐Temporal ROI was highly comparable across tracers across groups, except for the Aβ‐positive cognitively unimpaired group, where variability was more pronounced due to a smaller sample size (Figure 2A). Similarly, tau‐PET discriminative accuracy for symptomatic AD vs controls remained similar across [ 18 F]flortaucipir and [ 18 F]MK‐6240 (Figure 2B). In a separate sample of 212 matched participants from ADNI ([ 18 F]flortaucipir) and AIBL ([ 18 F]MK‐6240) with baseline and 1‐year follow‐up tau‐PET scans, 1‐year change in CenTauRs was comparable (Figure 2C). An exploratory voxelwise transformation, utilizing the Meta‐Temporal conversion equation in a representative case scanned with both [ 18 F]flortaucipir and [ 18 F]MK‐6240, demonstrates the potential for voxelwise CenTauR harmonization (Figure 3). Conclusion These analyses suggest that CenTauR harmonization increases the comparability of tau‐PET data acquired with different tracers. Additional validation analyses with larger cohorts including other radiotracers ([ 18 F]PI‐2620) are underway.
External Validation of Joint Propagation Model‐Based Tau PET CenTauR units
Abstract Background The Joint Propagation Model (JPM)‐based CenTauR scale was recently introduced to harmonize tau‐PET quantification across different radiotracers. This study examined how CenTauR harmonization enhances the comparability of tau‐PET quantification across matched cohorts using different tracers. The evaluation focused on three key aspects: (1) comparing tau‐PET positivity rates as defined by CenTauR, (2) evaluating its diagnostic accuracy for symptomatic AD, and (3) analyzing longitudinal changes in tau‐PET rates over time. Method The JPM, developed by the CPAD‐led Tau PET Harmonization Working Group (Leuzy et al., Alzheimers Dement. 2024; Figure 1A), models relationships between anchor point subjects and head‐to‐head tau‐PET SUVR data onto the CenTauR scale, providing conversion equations for multiple tracers. JPM equations were applied to [¹⁸F]flortaucipir SUVR (Meta‐temporal ROI) data from 561 cognitively impaired participants in the ADNI and OASIS‐3 studies. Using ROC analysis, we determined the CenTauR cut‐off for positivity (T+) that maximized the Youden index for discriminating between FDA‐approved positive/negative visual reads. Three separate cohorts, scanned using [¹⁸F]flortaucipir (ADNI), [¹⁸F]MK‐6240 (CPAS), and [¹⁸F]RO‐948 (BioFINDER‐2), were matched 1:1 by age, MMSE, amyloid‐β, and clinical diagnosis. CenTauR‐based metrics were compared across these cohorts. Result A cut‐off of 18 CenTauRs was found to optimally classify [ 18 F]flortaucipir PET visual reads (Figure 1B). The matching procedure identified 1089 participants (363 per cohort). The frequency of T+ using the 18 CenTauRs cut‐off for the Meta‐Temporal ROI was highly comparable across tracers across groups, except for the Aβ‐positive cognitively unimpaired group, where variability was more pronounced due to a smaller sample size (Figure 2A). Similarly, tau‐PET discriminative accuracy for symptomatic AD vs controls remained similar across [ 18 F]flortaucipir and [ 18 F]MK‐6240 (Figure 2B). In a separate sample of 212 matched participants from ADNI ([¹⁸F]flortaucipir) and AIBL ([¹⁸F]MK‐6240) with baseline and 1‐year follow‐up tau‐PET scans, 1‐year change in CenTauRs was comparable (Figure 2C). An exploratory voxelwise transformation, utilizing the Meta‐Temporal conversion equation in a representative case scanned with both [¹⁸F]flortaucipir and [¹⁸F]MK‐6240, demonstrates the potential for voxelwise CenTauR harmonization (Figure 3). Conclusion These analyses suggest that CenTauR harmonization increases the comparability of tau‐PET data acquired with different tracers. Additional validation analyses with larger cohorts including other radiotracers ([¹⁸F]PI‐2620) are underway.
Harmonizing tau positron emission tomography in Alzheimer's disease: The CenTauR scale and the joint propagation model
Abstract INTRODUCTION Tau‐positron emission tomography (PET) outcome data of patients with Alzheimer's disease (AD) cannot currently be meaningfully compared or combined when different tracers are used due to differences in tracer properties, instrumentation, and methods of analysis. METHODS Using head‐to‐head data from five cohorts with tau PET radiotracers designed to target tau deposition in AD, we tested a joint propagation model (JPM) to harmonize quantification (units termed “CenTauR” [CTR]). JPM is a statistical model that simultaneously models the relationships between head‐to‐head and anchor point data. JPM was compared to a linear regression approach analogous to the one used in the amyloid PET Centiloid scale. RESULTS A strong linear relationship was observed between CTR values across brain regions. Using the JPM approach, CTR estimates were similar to, but more accurate than, those derived using the linear regression approach. DISCUSSION Preliminary findings using the JPM support the development and adoption of a universal scale for tau‐PET quantification. Highlights Tested a novel joint propagation model (JPM) to harmonize quantification of tau PET. Units of common scale are termed “CenTauRs”. Tested a Centiloid‐like linear regression approach. Using five cohorts with head‐to‐head tau PET, JPM outperformed linearregressionbased approach. Strong linear relationship was observed between CenTauRs values across brain regions.