Distortion‐free imaging: A double encoding method (DIADEM) combined with multiband imaging for rapid distortion‐free high‐resolution diffusion imaging on a compact 3T with high‐performance gradients
BackgroundDistortion‐free, high‐resolution diffusion imaging using DIADEM (Distortion‐free Imaging: A Double Encoding Method), proposed recently, has great potential for clinical applications. However, it can suffer from prolonged scan times and its reliability for quantitative diffusion imaging has not been evaluated.PurposeTo investigate the clinical feasibility of DIADEM‐based high‐resolution diffusion imaging on a novel compact 3T (C3T) by evaluating the reliability of quantitative diffusion measurements and utilizing both the high‐performance gradients (80 mT/m, 700 T/m/s) and the sequence optimization with the navigator acquisition window reduction and simultaneous multislice (multiband) imaging.Study TypeProspective feasibility study.Phantom/SubjectsDiffusion quality control phantom scans to evaluate the reliability of quantitative diffusion measurements; 36 normal control scans for B0‐field mapping; six healthy and two patient subject scans with a brain tumor for comparisons of diffusion and anatomical imaging.Field Strength/Sequence3T; the standard single‐shot echo‐planar‐imaging (EPI), multishot DIADEM diffusion, and anatomical (2D‐FSE [fast‐spin‐echo], 2D‐FLAIR [fluid‐attenuated‐inversion‐recovery], and 3D‐MPRAGE [magnetization prepared rapid acquisition gradient echo]) imaging.AssessmentThe scan time reduction, the reliability of quantitative diffusion measurements, and the clinical efficacy for high‐resolution diffusion imaging in healthy control and brain tumor volunteers.Statistical TestBland–Altman analysis.ResultsThe scan time for high in‐plane (0.86 mm2) resolution, distortion‐free, and whole brain diffusion imaging were reduced from 10 to 5 minutes with the sequence optimizations. All of the mean apparent diffusion coefficient (ADC) values in phantom were within the 95% confidence interval in the Bland–Altman plot. The proposed acquisition with a total off‐resonance coverage of 597.2 Hz wider than the expected bandwidth of 500 Hz in human brain could yield a distortion‐free image without foldover artifacts. Compared with EPI, therefore, this approach allowed direct image matching with the anatomical images and enabled improved delineation of the tumor boundaries.Data ConclusionThe proposed high‐resolution diffusion imaging approach is clinically feasible on C3T due to a combination of hardware and sequence improvements.Level of Evidence3Technical EfficacyStage 1 J. Magn. Reson. Imaging 2020;51:296–310.
Improving apparent diffusion coefficient accuracy on a compact 3T MRI scanner using gradient nonlinearity correction
BackgroundGradient nonlinearity (GNL) leads to biased apparent diffusion coefficients (ADCs) in diffusion‐weighted imaging. A gradient nonlinearity correction (GNLC) method has been developed for whole body systems, but is yet to be tested for the new compact 3T (C3T) scanner, which exhibits more complex GNL due to its asymmetrical design.PurposeTo assess the improvement of ADC quantification with GNLC for the C3T scanner.Study TypePhantom measurements and retrospective analysis of patient data.Phantom/SubjectsA diffusion quality control phantom with vials containing 0–30% polyvinylpyrrolidone in water was used. For in vivo data, 12 patient exams were analyzed (median age, 33).Field Strength/SequenceImaging was performed on the C3T and two commercial 3T scanners. A clinical DWI (repetition time [TR] = 10,000 msec, echo time [TE] = minimum, b = 1000 s/mm2) sequence was used for phantom imaging and 10 patient cases and a clinical DTI (TR = 6000–10,000 msec, TE = minimum, b = 1000 s/mm2) sequence was used for two patient cases.AssessmentThe 0% vial was measured along three orthogonal axes, and at two different temperatures. The ADC for each concentration was compared between the C3T and two whole‐body scanners. Cerebrospinal fluid and white matter ADCs were quantified for each patient and compared to values in literature.Statistical TestsPaired t‐test and two‐way analysis of variance (ANOVA).ResultsFor all PVP concentrations, the corrected ADC was within 2.5% of the reference ADC. On average, the ADC of cerebrospinal fluid and white matter post‐GNLC were within 1% and 6%, respectively, of values reported in the literature and were significantly different from the uncorrected data (P < 0.05).Data ConclusionThis study demonstrated that GNL effects were more severe for the C3T due to the asymmetric gradient design, but our implementation of a GNLC compensated for these effects, resulting in ADC values that are in good agreement with values from the literature.Level of Evidence: 4Technical Efficacy: Stage 2J. Magn. Reson. Imaging 2018;48:1498–1507
Waveguide effects and implications for cardiac magnetic resonance elastography: A finite element study
Magnetic resonance elastography (MRE) is increasingly being applied to thin or small structures in which wave propagation is dominated by waveguide effects, which can substantially bias stiffness results with common processing approaches. The purpose of this work was to investigate the importance of such biases and artifacts on MRE inversion results in: (i) various idealized 2D and 3D geometries with one or more dimensions that are small relative to the shear wavelength; and (ii) a realistic cardiac geometry. Finite element models were created using simple 2D geometries as well as a simplified and a realistic 3D cardiac geometry, and simulated displacements acquired by MRE from harmonic excitations from 60 to 220 Hz across a range of frequencies. The displacement wave fields were inverted with direct inversion of the Helmholtz equation with and without the application of bandpass filtering and/or the curl operator to the displacement field. In all geometries considered, and at all frequencies considered, strong biases and artifacts were present in inversion results when the curl operator was not applied. Bandpass filtering without the curl was not sufficient to yield accurate recovery. In the 3D geometries, strong biases and artifacts were present in 2D inversions even when the curl was applied, while only 3D inversions with application of the curl yielded accurate recovery of the complex shear modulus. These results establish that taking the curl of the wave field and performing a full 3D inversion are both necessary steps for accurate estimation of the shear modulus both in simple thin‐walled or small structures and in a realistic cardiac geometry when using simple inversions that neglect the hydrostatic pressure term. In practice, sufficient wave amplitude, signal‐to‐noise ratio, and resolution will be required to achieve accurate results.
In vivo characterization of 3D skull and brain motion during dynamic head vibration using magnetic resonance elastography
PurposeTo introduce newly developed MR elastography (MRE)‐based dual‐saturation imaging and dual‐sensitivity motion encoding schemes to directly measure in vivo skull–brain motion, and to study the skull–brain coupling in volunteers with these approaches.MethodsSix volunteers were scanned with a high‐performance compact 3T‐MRI scanner. The skull–brain MRE images were obtained with a dual‐saturation imaging where the skull and brain motion were acquired with fat‐ and water‐suppression scans, respectively. A dual‐sensitivity motion encoding scheme was applied to estimate the heavily wrapped phase in skull by the simultaneous acquisition of both low‐ and high‐sensitivity phase during a single MRE exam. The low‐sensitivity phase was used to guide unwrapping of the high‐sensitivity phase. The amplitude and temporal phase delay of the rigid‐body motion between the skull and brain was measured, and the skull–brain interface was visualized by slip interface imaging (SII).ResultsBoth skull and brain motion can be successfully acquired and unwrapped. The skull–brain motion analysis demonstrated the motion transmission from the skull to the brain is attenuated in amplitude and delayed. However, this attenuation (%) and delay (rad) were considerably greater with rotation (59 ± 7%, 0.68 ± 0.14 rad) than with translation (92 ± 5%, 0.04 ± 0.02 rad). With SII the skull–brain slip interface was not completely evident, and the slip pattern was spatially heterogeneous.ConclusionThis study provides a framework for acquiring in vivo voxel‐based skull and brain displacement using MRE that can be used to characterize the skull–brain coupling system for understanding of mechanical brain protection mechanisms, which has potential to facilitate risk management for future injury.
Lightweight, compact, and high‐performance 3T MR system for imaging the brain and extremities
PurposeTo build and evaluate a small‐footprint, lightweight, high‐performance 3T MRI scanner for advanced brain imaging with image quality that is equal to or better than conventional whole‐body clinical 3T MRI scanners, while achieving substantial reductions in installation costs.MethodsA conduction‐cooled magnet was developed that uses less than 12 liters of liquid helium in a gas‐charged sealed system, and standard NbTi wire, and weighs approximately 2000 kg. A 42‐cm inner‐diameter gradient coil with asymmetric transverse axes was developed to provide patient access for head and extremity exams, while minimizing magnet‐gradient interactions that adversely affect image quality. The gradient coil was designed to achieve simultaneous operation of 80‐mT/m peak gradient amplitude at a slew rate of 700 T/m/s on each gradient axis using readily available 1‐MVA gradient drivers.ResultsIn a comparison of anatomical imaging in 16 patients using T2‐weighted 3D fluid‐attenuated inversion recovery (FLAIR) between the compact 3T and whole‐body 3T, image quality was assessed as equivalent to or better across several metrics. The ability to fully use a high slew rate of 700 T/m/s simultaneously with 80‐mT/m maximum gradient amplitude resulted in improvements in image quality across EPI, DWI, and anatomical imaging of the brain.ConclusionsThe compact 3T MRI system has been in continuous operation at the Mayo Clinic since March 2016. To date, over 200 patient studies have been completed, including 96 comparison studies with a clinical 3T whole‐body MRI. The increased gradient performance has reliably resulted in consistently improved image quality.
Time‐resolved contrast‐enhanced MR angiography with single‐echo Dixon fat suppression
PurposeDixon‐based fat suppression has recently gained interest for dynamic contrast‐enhanced MRI, but multi‐echo techniques require longer scan times and reduce temporal resolution compared to single‐echo alternatives without fat suppression. The purpose of this work is to demonstrate accelerated single‐echo Dixon imaging with high spatial and temporal resolution.Theory and MethodsReal‐valued water and fat images can be obtained from a single measurement if the shared initial phase and that due to are assumed known a priori. An expression for simultaneous sensitivity encoding (SENSE) unfolding and fat‐water separation is derived for the general undersampling case, and simplified under the special case of uniform Cartesian undersampling. In vivo experiments were performed in extremities and brain with SENSE acceleration factors of up to R = 8.ResultsSingle‐echo Dixon reconstruction of highly undersampled data was successfully demonstrated. Dynamic contrast‐enhanced water and fat images provided high spatial and temporal resolution dynamic images with image update times shorter than previous single‐echo Dixon work.ConclusionTime‐resolved contrast‐enhanced MRI with single‐echo Dixon fat suppression shows high image quality, improved vessel delineation, and reduced sensitivity to motion when compared to time‐subtraction methods.
Cardiac MR elastography using reduced‐FOV, single‐shot, spin‐echo EPI