Back to Authors

Rossman, Timothy

Mayo Clinic

Mayo Clinic

Citations 4

Pulsatility of Pulmonary Artery Waveforms Before and After Left Ventricular Assist Device Is Associated With Right Ventricular Failure
Rosenbaum, Andrew , Behfar, Atta , Rossman, Timothy, Lundgren, Scott , Rosenbaum, Andrew N , Rossman, Timothy L, Lundgren, Scott W , Behfar, Atta

ASAIO Journal | July 16, 2024 | Volume: 71 | Issue: 3 | Pages: e38-e40

10.1097/mat.0000000000002272 Get It

Modification of Humeral Component Results in Increased Impingement Free Range of Motion in a Reverse Shoulder Arthroplasty Model
Schroeder, Dalton Dale, Borsgard, Alexander, Rossman, Timothy, Stewart, Cory Michael , Rossman, Timothy Lee

Journal of Shoulder and Elbow Arthroplasty | April 15, 2024 | Volume: 8 | Issue: No issue available | Pages: No page available

10.1177/24715492241237034 Get It

Introduction Shoulder arthroplasties have been demonstrated to provide reliable pain relief as well as functional benefits. The advent of the reverse shoulder arthroplasty allowed for expanded indications for shoulder replacement. Several studies comparing the outcomes of anatomic and reverse total shoulder arthroplasties have demonstrated decreased range of motion in the reverse arthroplasty cohort, especially in internal rotation. The authors hypothesized that slight modifications to the humeral component of a reverse shoulder arthroplasty could result in increased impingement free range of motion without significant sacrifices to stability. Methods A reverse shoulder arthroplasty model was fashioned to mimic a setting of anterior mechanical impingement after replacement. Sequential resections were taken from the anterior aspect of the polyethylene up to a resection of 10 mm. A solid modeling software was utilized to compare the experimental group to the control group with regard to impingement free motion. Finite element analysis was subsequently utilized to assess stability of the construct in comparison to the nonmodified polyethylene. Results Impingement free internal rotation increased minimally at 3 mm of resection but considerably at each further increase in resection. A resection of 10 mm resulted roughly 30% improvement in impingement free internal rotation. Instability in this model increased with modifications beyond 7 mm. Conclusion Slight alterations to the geometry of the humeral tray and polyethene components can result in improvements in impingement-free internal rotation without substantial increased instability in this model. Further work is needed to determine in vivo implications of modifications to the humeral tray and polyethylene.
Pulsatile Pressure Delivery of Continuous-Flow Left Ventricular Assist Devices Is Markedly Reduced Relative to Heart Failure Patients
Rosenbaum, Andrew , Rossman, Timothy, Reddy, Yogesh N.V. , Villavicencio, Mauricio A. , Stulak, John M., Spencer, Philip J. , Kushwaha, Sudhir S. , Behfar, Atta , Rosenbaum, Andrew N , Rossman, Timothy L, Nishimura, Rick , Behfar, Atta , Kushwaha, Sudhir

ASAIO Journal | November 23, 2022 | Volume: 69 | Issue: 5 | Pages: 445-450

10.1097/mat.0000000000001859 Get It

Although continuous-flow left ventricular assist devices (CF-LVADs) provide an augmentation in systemic perfusion, there is a scarcity of in vivo data regarding systemic pulsatility on support. Patients supported on CF-LVAD therapy (n = 71) who underwent combined left/right catheterization ramp study were included. Aortic pulsatility was defined by the pulsatile power index (PPI), which was also calculated in a cohort of high-output heart failure (HOHF, n = 66) and standard HF cohort (n = 44). PPI was drastically lower in CF-LVAD–supported patients with median PPI of 0.006 (interquartile range [IQR], 0.002–0.012) compared with PPI in the HF population at 0.09 (IQR, 0.06–0.17) or HOHF population at 0.25 (IQR, 0.13–0.37; p < 0.0001 among groups). With speed augmentation during ramp, PPI values fell quickly in patients with higher PPI at baseline. PPI correlated poorly with left ventricular ejection fraction (LVEF) in all groups. In CF-LVAD patients, there was a stronger correlation with LV dP/dt (r = 0.41; p = 0.001) than LVEF (r = 0.21; p = 0.08; p int < 0.001). CF-LVAD support is associated with a dramatic reduction in arterial pulsatility as measured by PPI relative to HOHF and HF cohorts and decreases with speed. Further work is needed to determine the applicability to the next generation of device therapy.
Waveguide effects and implications for cardiac magnetic resonance elastography: A finite element study
Manduca, Armando , Rossman, Timothy, Lake, David S. , Glaser, Kevin J. , Arani, Arvin , Rossman, Phillip J. , Trzasko, Joshua D. , Dragomir‐Daescu, Dan , Araoz, Philip A. , Manduca, A , Arunachalam, S P , Arani, Arvin , Arunachalam, Shivaram P. , Ehman, Richard L.

NMR in Biomedicine | August 13, 2018 | Volume: 31 | Issue: 10 | Pages: No page available

10.1002/nbm.3996 Get It

Magnetic resonance elastography (MRE) is increasingly being applied to thin or small structures in which wave propagation is dominated by waveguide effects, which can substantially bias stiffness results with common processing approaches. The purpose of this work was to investigate the importance of such biases and artifacts on MRE inversion results in: (i) various idealized 2D and 3D geometries with one or more dimensions that are small relative to the shear wavelength; and (ii) a realistic cardiac geometry. Finite element models were created using simple 2D geometries as well as a simplified and a realistic 3D cardiac geometry, and simulated displacements acquired by MRE from harmonic excitations from 60 to 220 Hz across a range of frequencies. The displacement wave fields were inverted with direct inversion of the Helmholtz equation with and without the application of bandpass filtering and/or the curl operator to the displacement field. In all geometries considered, and at all frequencies considered, strong biases and artifacts were present in inversion results when the curl operator was not applied. Bandpass filtering without the curl was not sufficient to yield accurate recovery. In the 3D geometries, strong biases and artifacts were present in 2D inversions even when the curl was applied, while only 3D inversions with application of the curl yielded accurate recovery of the complex shear modulus. These results establish that taking the curl of the wave field and performing a full 3D inversion are both necessary steps for accurate estimation of the shear modulus both in simple thin‐walled or small structures and in a realistic cardiac geometry when using simple inversions that neglect the hydrostatic pressure term. In practice, sufficient wave amplitude, signal‐to‐noise ratio, and resolution will be required to achieve accurate results.