AbstractObjectiveHLA‐DPB1 matching may impact allogeneic hematopoietic stem cell transplantation (ASCT) outcomes; however, this locus is not in linkage disequilibrium with the remainder of the HLA genes. After classifying HLA‐DPB1 mismatches based on T‐cell epitope, avoiding non‐permissive mismatches may impact survival. We tested this hypothesis at a single academic institution.MethodsRetrospective HLA‐DPB1 genotyping was performed on 153 adult patients who underwent ASCT and unrelated donors matched for HLA‐A, B, C, DRB1, and DQB1 loci (10/10). Using the ImMunoGeneTics/HLA T‐cell epitope matching algorithm, mismatch status was classified as permissive or non‐permissive.ResultsOf 153 donor‐recipient pairs, 22 (14.4%) were HLA‐DPB1 matches, 64 (42.8%) permissive mismatches, and 67 (43.8%) non‐permissive mismatches. DPB1 mismatch increased risk of chronic graft‐versus‐host disease (cGVHD; RR 2.89 [1.19‐9.53], P=.016) compared with DPB1‐matched transplants, but there were no differences in overall mortality, risk of relapse, or acute GVHD (aGVHD). Combining matches and permissive mismatches and comparing to non‐permissive mismatches, there was no significant difference in overall survival or relapse; however, patients receiving non‐permissive mismatched transplants experienced greater risk of aGVHD overall and severe aGVHD (RR 1.66 [1.13‐2.44], P=.010 and RR 1.97 [1.10‐3.59], P=.024, respectively).ConclusionIn this single‐center study, HLA‐DPB1 matching influenced outcomes of patients undergoing ASCT for hematologic malignancy.
Early‐life decline in neurogenesis markers and age‐related changes of TrkB splice variant expression in the human subependymal zone
AbstractNeurogenesis in the subependymal zone (SEZ) declines across the human lifespan, and reduced local neurotrophic support is speculated to be a contributing factor. While tyrosine receptor kinase B (TrkB) signalling is critical for neuronal differentiation, maturation and survival, little is known about subependymal TrkB expression changes during postnatal human life. In this study, we used quantitative PCR and in situ hybridisation to determine expression of the cell proliferation marker Ki67, the immature neuron marker doublecortin (DCX) and both full‐length (TrkB‐TK+) and truncated TrkB receptors (TrkB‐TK‐) in the human SEZ from infancy to middle age (n = 26–35, 41 days to 43 years). We further measured TrkB‐TK+ and TrkB‐TK‐ mRNAs in the SEZ from young adulthood into ageing (n = 50, 21–103 years), and related their transcript levels to neurogenic and glial cell markers. Ki67, DCX and both TrkB splice variant mRNAs significantly decreased in the SEZ from infancy to middle age. In contrast, TrkB‐TK‐ mRNA increased in the SEZ from young adulthood into ageing, whereas TrkB‐TK+ mRNA remained stable. TrkB‐TK‐ mRNA positively correlated with expression of neural precursor (glial fibrillary acidic protein delta and achaete‐scute homolog 1) and glial cell markers (vimentin and pan glial fibrillary acidic protein). TrkB‐TK+ mRNA positively correlated with expression of neuronal cell markers (DCX and tubulin beta 3 class III). Our results indicate that cells residing in the human SEZ maintain their responsiveness to neurotrophins; however, this capability may change across postnatal life. We suggest that TrkB splice variants may differentially influence neuronal and glial differentiation in the human SEZ.
Safety of Sports for Athletes With Implantable Cardioverter-Defibrillators
Introduction: This study set out to clarify the differential acute cognitive impact of lorazepam based on varying genetic risk for Alzheimer disease. Methods: Fifty-seven cognitively unimpaired individuals aged 51 to 88, genotyped according to apolipoprotein E (APOE) and translocase of outer mitochondrial membrane (40 homolog) poly-T lengths, completed cognitive testing before, 2.5 and 5 hours after receiving a 1 mg dose of lorazepam. Results: Post-lorazepam, there were significant (P<0.05) declines from baseline in memory, psychomotor processing speed, and executive function. At 2.5 hours, the magnitude of this lorazepam-induced cognitive change was significantly greater in the APOE3/4 group than in the APOE3/3 group for tests of working memory and visuospatial memory/executive function. At 5 hours postchallenge, verbal memory and working memory deficits persisted in the APOE3/4 group compared with the APOE3/3 group. At 5 hours after lorazepam challenge, as compared with the very long/very long group, the short/short group performed slightly worse on a test of working memory (P<0.05), but no other differences were observed among translocase of the outer mitochondrial membrane 40 homolog poly-T variant groups. Discussion: The lorazepam challenge may be unmasking presymptomatic cognitive dysfunction associated with APOE4 carriage.
Cochlear Implant Electrode Localization Using an Ultra-High Resolution Scan Mode on Conventional 64-Slice and New Generation 192-Slice Multi-Detector Computed Tomography
Hypothesis: A new generation 192-slice multi-detector computed tomography (MDCT) clinical scanner provides enhanced image quality and superior electrode localization over conventional MDCT. Background: Currently, accurate and reliable cochlear implant electrode localization using conventional MDCT scanners remains elusive. Methods: Eight fresh-frozen cadaveric temporal bones were implanted with full-length cochlear implant electrodes. Specimens were subsequently scanned with conventional 64-slice and new generation 192-slice MDCT scanners utilizing ultra-high resolution modes. Additionally, all specimens were scanned with micro-CT to provide a reference criterion for electrode position. Images were reconstructed according to routine temporal bone clinical protocols. Three neuroradiologists, blinded to scanner type, reviewed images independently to assess resolution of individual electrodes, scalar localization, and severity of image artifact. Results: Serving as the reference standard, micro-CT identified scalar crossover in one specimen; imaging of all remaining cochleae demonstrated complete scala tympani insertions. The 192-slice MDCT scanner exhibited improved resolution of individual electrodes (p < 0.01), superior scalar localization (p < 0.01), and reduced blooming artifact (p < 0.05), compared with conventional 64-slice MDCT. There was no significant difference between platforms when comparing streak or ring artifact. Conclusion: The new generation 192-slice MDCT scanner offers several notable advantages for cochlear implant imaging compared with conventional MDCT. This technology provides important feedback regarding electrode position and course, which may help in future optimization of surgical technique and electrode design.
Correlation between a 2D channelized Hotelling observer and human observers in a low‐contrast detection task with multislice reading in CT
PurposeModel observers have been successfully developed and used to assess the quality of static 2D CT images. However, radiologists typically read images by paging through multiple 2D slices (i.e., multislice reading). The purpose of this study was to correlate human and model observer performance in a low‐contrast detection task performed using both 2D and multislice reading, and to determine if the 2D model observer still correlate well with human observer performance in multislice reading.MethodsA phantom containing 18 low‐contrast spheres (6 sizes × 3 contrast levels) was scanned on a 192‐slice CT scanner at five dose levels (CTDIvol = 27, 13.5, 6.8, 3.4, and 1.7 mGy), each repeated 100 times. Images were reconstructed using both filtered‐backprojection (FBP) and an iterative reconstruction (IR) method (ADMIRE, Siemens). A 3D volume of interest (VOI) around each sphere was extracted and placed side‐by‐side with a signal‐absent VOI to create a 2‐alternative forced choice (2AFC) trial. Sixteen 2AFC studies were generated, each with 100 trials, to evaluate the impact of radiation dose, lesion size and contrast, and reconstruction methods on object detection. In total, 1600 trials were presented to both model and human observers. Three medical physicists acted as human observers and were allowed to page through the 3D volumes to make a decision for each 2AFC trial. The human observer performance was compared with the performance of a multislice channelized Hotelling observer (CHO_MS), which integrates multislice image data, and with the performance of previously validated CHO, which operates on static 2D images (CHO_2D). For comparison, the same 16 2AFC studies were also performed in a 2D viewing mode by the human observers and compared with the multislice viewing performance and the two CHO models.ResultsHuman observer performance was well correlated with the CHO_2D performance in the 2D viewing mode [Pearson product‐moment correlation coefficient R = 0.972, 95% confidence interval (CI): 0.919 to 0.990] and with the CHO_MS performance in the multislice viewing mode (R = 0.952, 95% CI: 0.865 to 0.984). The CHO_2D performance, calculated from the 2D viewing mode, also had a strong correlation with human observer performance in the multislice viewing mode (R = 0.957, 95% CI: 879 to 0.985). Human observer performance varied between the multislice and 2D modes. One reader performed better in the multislice mode (P = 0.013); whereas the other two readers showed no significant difference between the two viewing modes (P = 0.057 and P = 0.38).ConclusionsA 2D CHO model is highly correlated with human observer performance in detecting spherical low contrast objects in multislice viewing of CT images. This finding provides some evidence for the use of a simpler, 2D CHO to assess image quality in clinically relevant CT tasks where multislice viewing is used.
Magnetic resonance elastography measured shear stiffness as a biomarker of fibrosis in pediatric nonalcoholic fatty liver disease
Magnetic resonance elastography (MRE) is a promising technique for noninvasive assessment of fibrosis, a major determinant of outcome in nonalcoholic fatty liver disease (NAFLD). However, data in children are limited. The purpose of this study was to determine the accuracy of MRE for the detection of fibrosis and advanced fibrosis in children with NAFLD and to assess agreement between manual and novel automated reading methods. We performed a prospective, multicenter study of two‐dimensional (2D) MRE in children with NAFLD. MR elastograms were analyzed manually at two reading centers, and using a new automated technique. Analysis using each approach was done independently. Correlations were determined between MRE analysis methods and fibrosis stage. Thresholds for classifying the presence of fibrosis and of advanced fibrosis were computed and cross‐validated. In 90 children with a mean age of 13.1 ± 2.4 years, median hepatic stiffness was 2.35 kPa. Stiffness values derived by each reading center were strongly correlated with each other (r = 0.83). All three analyses were significantly correlated with fibrosis stage (center 1, ρ = 0.53; center 2, ρ = 0.55; and automated analysis, ρ = 0.52; P < 0.001). Overall cross‐validated accuracy for detecting any fibrosis was 72.2% for all methods (95% confidence interval [CI], 61.8%‐81.1%). Overall cross‐validated accuracy for assessing advanced fibrosis was 88.9% (95% CI, 80.5%‐94.5%) for center 1, 90.0% (95% CI, 81.9%‐95.3%) for center 2, and 86.7% (95% CI, 77.9%‐92.9%) for automated analysis. Conclusion : 2D MRE can estimate hepatic stiffness in children with NAFLD. Further refinement and validation of automated analysis techniques will be an important step in standardizing MRE. How to best integrate MRE into clinical protocols for the assessment of NAFLD in children will require prospective evaluation. (H epatology 2017;66:1474–1485)