Back to Authors

Guerrero, Mayra

https://orcid.org/0000-0002-9151-8096

Mayo Clinic

Mayo Clinic

Citations 71

Predictors of Left Ventricular Outflow Tract Obstruction After Transcatheter Mitral Valve Replacement in Severe Mitral Annular Calcification: An Analysis of the Transcatheter Mitral Valve Replacement in Mitral Annular Calcification Global Registry
Sabbagh, Abdallah El , Al‐Hijji, Mohammed , Wang, Dee Dee , Eleid, Mackram F. , Ureña, Marina , Himbert, Dominique , Chakravarty, Tarun , Fang, Hao , Zahr, Firas , Dvir, Danny , Sardar, Muhammad , Cheema, Asim N. , Alnasser, Sami , Iyer, Vijay , Kaddissi, Georges, Webb, John G. , Makkar, Raj , Vahanian, Alec , Rihal, Charanjit S. , Eleid, Mackram F , Nejjari, Mohammed , Dvir, Danny , Rihal, Charanjit, Guerrero, Mayra E , Al-Hijji, Mohammed A , Wang, Dee Dee , Holzhey, David Michael , Pershad, Ashish , Nejjari, Mohammed , O’Neill, William W. , Rihal, Charanjit S. , Guerrero, Mayra

Circulation: Cardiovascular Interventions | October 19, 2021 | Volume: 14 | Issue: 10 | Pages: No page available

10.1161/circinterventions.121.010854 Get It

Background: Several studies have evaluated preprocedural imaging predictors of left ventricular outflow tract obstruction (LVOTO) after transcatheter mitral valve replacement. The patient cohorts in these studies were heterogeneous and included patients with transcatheter mitral valve replacement in failed bioprostheses, annuloplasty rings, and severe mitral annular calcification (MAC). The goal of this study was to evaluate predictors of LVOTO specific to patients undergoing valve-in-MAC. Methods: This study included patients with severe MAC who underwent valve-in-MAC and had optimal quality preprocedural multidetector row computed tomography scans eligible for retrospective analysis. Baseline demographic, echocardiographic, and procedural data on these patients were collected. multidetector row computed tomography parameters were analyzed for association with LVOTO, defined as increase in mean LVOT gradient by ≥10 mm Hg with accompanying hemodynamic instability. Results: Seventy-one patients with optimal preprocedural computed tomography scans were included in this study (mean age, 72.5±13.5 years), 9 of which developed LVOTO (all female). Baseline mean LVOT area, neo-LVOT area (145.3 versus 270.9 mm 2 ; P =0.006), indexed neo-LVOT area (90.1 versus 157.4; P =0.05), and virtual transcatheter heart valve to septum distance (3.1 versus 6.9 mm; P =0.002) were lower in the LVOTO group. Expected % LVOT area reduction was higher in the latter group (58.3 versus 42.7%; P =0.008). In the univariable analysis, the baseline mean LVOT area, neo-LVOT area, indexed neo-LVOT area, and valve to septum distance were all significantly associated with LVOTO. Conclusions: The systolic mean LVOT area, neo-LVOT area, indexed neo-LVOT, expected percentage LVOT area reduction, and the valve to septum distance were associated with LVOTO after valve-in-MAC.
Utility of Intracardiac Echocardiography in the Early Experience of Transcatheter Edge to Edge Tricuspid Valve Repair
Eleid, Mackram F. , Alkhouli, Mohamad , Thaden, Jeremy J. , Zahr, Firas , Guerrero, Mayra , Reeder, Guy S., Rihal, Charanjit S. , Guerrero, Mayra E , Alkhouli, Mohamad , Chadderdon, Scott , Rihal, Charanjit S.

Circulation: Cardiovascular Interventions | September 3, 2021 | Volume: 14 | Issue: 10 | Pages: No page available

10.1161/circinterventions.121.011118 Get It

Background: Tricuspid edge to edge repair (TEER) is a novel treatment for severe tricuspid regurgitation and is highly dependent on intraprocedural image quality. To date, transesophageal echocardiography (TEE) has been the primary imaging modality used to guide TEER. The role of intracardiac echocardiography (ICE) has not been assessed. The objective of this study was to describe the use and role of 2-dimensional ICE in the early experience of TEER. Methods: Consecutive patients undergoing TEER (with or without concomitant mitral repair) with off-label use of MitraClip (Abbott, Santa Clara, CA) were included in the study. Utilization of 2-dimensional ICE in comparison with TEE imaging were collected in each procedure through retrospective review of the procedural reports and images. Results: Of 42 TEER cases, ICE was used in 15 (36%) and concomitant mitral repair was performed in 37 (86%). ICE was increasingly used over time for TEER. ICE was able to visualize the tricuspid leaflets with high resolution and provided superior leaflet visualization to TEE in 40% of cases where it was used. Patients treated with ICE guidance tended to have a greater baseline severity of tricuspid regurgitation compared with patients treated with TEE guidance alone (8/15 [53%] massive or greater tricuspid regurgitation versus 6/27 [22%]; P =0.09). Degree of tricuspid regurgitation reduction was similar with TEE alone versus ICE plus TEE guidance (1.9±1.0 versus 2.1±1.1 grade reduction, P =0.28). Conclusions: ICE was increasingly used in the early experience of TEER over time. ICE facilitates leaflet visualization for grasping and is a useful adjunct to TEE during TEER.
Effect of eliminating pre‐discharge transthoracic echocardiogram on outcomes after TAVR
Welle, Garrett A. , El‐Sabawi, Bassim , Thaden, Jeremy J. , Greason, Kevin L. , Klarich, Kyle W. , Gulati, Rajiv , Rihal, Charanjit S. , Eleid, Mackram F. , Alkhouli, Mohamad A, Eleid, Mackram F , Welle, Garrett A , Nkomo, Vuyisile T. , Alkhouli, Mohamad , Guerrero, Mayra , Crestanello, Juan A. , Rihal, Charanjit S.

Catheterization and Cardiovascular Interventions | August 13, 2021 | Volume: 99 | Issue: 3 | Pages: 861-866

10.1002/ccd.29929 Get It

AbstractObjectivesThe aim of this study was to determine the safety of eliminating the pre‐discharge transthoracic echocardiogram (TTE) on 30‐day outcomes in patients undergoing transcatheter aortic valve replacement (TAVR).BackgroundTTE is utilized before, during, and after TAVR. Post‐procedural, pre‐discharge TTE assists in assessment of prosthesis function and detection of clinically significant paravalvular leak (PVL) after TAVR.MethodsPatients who underwent TAVR at Mayo Clinic from July 2018 to July 2019 were included in a prospective institutional registry. Patients undergoing TAVR prior to February 2019 received a pre‐discharge TTE, while those undergoing TAVR after February 2019 did not. Both cohorts were evaluated with TTE at 30 days post‐TAVR.ResultsA total of 330 consecutive patients were included. Of these, 160 patients (age 81.1 ± 7.6) had routine pre‐discharge TTE, while 170 patients (age 78.9 ± 7.5) were dismissed without routine pre‐discharge TTE. Mortality at 30 days was similar between the two groups (0% and 1.2%, respectively). One episode of PVL requiring intervention (0.6%) occurred in the pre‐discharge TTE group and none in the group without pre‐discharge TTE at 30‐day follow‐up. There was a similar incidence of total composite primary and secondary adverse events between the cohort receiving a pre‐discharge TTE and those without (28.1% vs. 25.3%, P = 0.56) at 30 days. The most common event was need for permanent pacemaker or ICD implantation in both groups (13.1% vs. 11.8%, P = 0.71).ConclusionsElimination of the pre‐discharge TTE is safe and associated with comparable 30‐day outcomes to routine pre‐discharge TTE. These findings have implication for TAVR practice cost‐efficiency and health care utilization.
Clinical predictors and impact of postoperative mean gradient on outcome after transcatheter edge‐to‐edge mitral valve repair
Oğuz, Didem , Padang, Ratnasari , Mankad, Sunil , Reeder, Guy S., Eleid, Mackram F. , Rihal, Charanjit S. , Thaden, Jeremy J. , Mankad, Sunil V., Eleid, Mackram F , Pislaru, Sorin V. , Nkomo, Vuyisile T. , Alkhouli, Mohamad , Guerrero, Mayra , Rihal, Charanjit S.

Catheterization and Cardiovascular Interventions | July 10, 2021 | Volume: 98 | Issue: 6 | Pages: No page available

10.1002/ccd.29867 Get It

AbstractBackgroundThe predictors and clinical significance of increased Doppler‐derived mean diastolic gradient (MG) following transcatheter edge‐to‐edge mitral valve repair (MVTEER) remain controversial.ObjectiveWe sought to examine baseline correlates of Doppler‐derived increased MG post‐MVTEER and its impact on intermediate‐term outcomes.MethodsPatients undergoing MVTEER were analyzed retrospectively. Post‐MVTEER increased MG was defined as >5 mmHg or aborted clip implantation due to increased MG intraprocedurally. Baseline MG and 3D‐guided mitral valve area (MVA) by planimetry were retrospectively available in 233 and 109 patients.Results243 patients were included; 62 (26%) had MG > 5 mmHg post‐MVTEER or aborted clip insertion, including 7 (11%) that had aborted clip implantation. Mortality occurred in 63 (26%) during a median follow up of 516 days (IQR 211, 1021). Increased post‐MVTEER MG occurred more frequently in females (44% vs. 16%, p < 0.001), those with baseline MVA <4.0 cm2 (71% vs. 16%), baseline MG ≥4 mmHg (61% vs. 20%), or multiple clips implanted (33% vs. 21%, p = 0.04). Increased post‐MVTEER MG was associated with increased subsequent mortality compared to those with normal gradient (HR 1.91 95% CI 1.15–3.18 p = 0.016) as was aborted clip insertion compared to all others (HR 5.23 95% CI 2.06–13.28 p < 0.001).ConclusionsSmaller baseline MVA and increased baseline MG are associated with increased MG post‐MVTEER and patients with a Doppler‐derived post‐MVTEER MG >5 mmHg suffered excess subsequent mortality. In high risk patients considered for MVTEER, identification of those at risk of iatrogenic mitral stenosis with MVTEER is important as they may be optimally treated with alternate surgical or transcatheter therapies.
Short‐ and mid‐term outcomes in percutaneous mitral valve replacement using balloon expandable valves
Eng, Marvin H. , Kargoli, Faraj , Wang, Dee Dee , Frisoli, Tiberio , Villablanca, Pedro, Nemeh, Hassan, Guerrero, Mayra , O’Neill, Brian , Wyman, Janet , Guerrero, Mayra E , O'Neill, Brian P , Wang, Dee Dee , Lee, James C. , Villablanca, Pedro, Greenbaum, Adam B. , O’Neill, William W.

Catheterization and Cardiovascular Interventions | June 9, 2021 | Volume: 98 | Issue: 6 | Pages: 1193-1203

10.1002/ccd.29783 Get It

AbstractBackgroundDue to elevated surgical risk, transcatheter mitral valve replacement (TMVR) is used as an alternative for treating failed bioprosthetic valves, annuloplasty repairs and mitral annular calcification (MAC). We report the procedural and longitudinal outcomes for each subtype: Mitral valve‐in‐valve (MVIV), mitral valve‐in‐ring (MViR), and valve‐in‐MAC (ViMAC).MethodsConsecutive patients undergoing TMVR from October 2013 to December 2019 were assessed. Patients at high risk for left ventricular outflow tract obstruction had either alcohol septal ablation or intentional laceration of the anterior leaflet (LAMPOON).ResultsEight‐eight patients underwent TMVR; 38 MViV, 31 MViR, and 19 ViMAC procedures were performed. The median Society of Thoracic Surgery 30‐day predicted risk of mortality was 8.2% (IQR 5.2, 19.9) for all. Sapien 3 (78%) and transseptal access (98%) were utilized in most cases. All‐cause in‐hospital mortality, technical, and procedural success were 8%, 83%, and 66% respectively. Median follow up was 1.4 years (IQR 0.5–2.9 years) and overall survival was 40% at 4 years. Differential survival rates were observed with MViV doing the best, followed by MViR and ViMAC having a <20% survival at 4 years. After adjusting for co‐variates, MViV procedure was the strongest predictor of survival (HR 0.24 [95% CI 0.079–0.7]).ConclusionTMVR is performed in at high‐risk patients with attenuated long‐term survival. MViV has the best success and survival rate, but long‐term survival in MViR and ViMAC is guarded.
Hemolysis after transcatheter mitral valve replacement in degenerated bioprostheses, annuloplasty rings, and mitral annular calcification: Incidence, patient characteristics, and clinical outcomes
El‐Sabawi, Bassim , Eleid, Mackram F. , Rihal, Charanjit S. , Eleid, Mackram F , Guerrero, Mayra , Nkomo, Vuyisile T. , Pislaru, Sorin V. , Rihal, Charanjit S.

Catheterization and Cardiovascular Interventions | May 31, 2021 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.1002/ccd.29779 Get It

Association of Transcatheter Mitral Valve Repair Availability With Outcomes of Mitral Valve Surgery
Alkhouli, Mohamad , Kawsara, Akram , Eleid, Mackram F. , Nkomo, Vuyisile T. , Rihal, Charanjit S. , Alqahtani, Fahad, Alkhouli, Mohamad , Nkomo, Vuyisile T , Alqahtani, Fahad , Guerrero, Mayra , Rihal, Charanjit S. , Crestanello, Juan A.

Journal of the American Heart Association | March 23, 2021 | Volume: 10 | Issue: 7 | Pages: No page available

10.1161/jaha.120.019314 Get It

Background Transcatheter mitral valve repair (TMVr) is currently offered at selected centers that meet certain operator and institutional requirements. We sought to explore the hypothesis that the availability of TMVr is associated with improved outcomes of MV surgery. Methods and Results We used the Nationwide Readmissions Database to identify patients who underwent MV surgery at centers with or without TMVr capabilities between January 1 and December 31, 2017. The primary end point was in‐hospital mortality. Secondary end points were postoperative complications, resource use, and 30‐day readmissions. A total of 24 477 patients from 595 centers (446 TMVr, 149 non‐TMVr) were included. There were modest but statistically significant differences in the prevalence of comorbidities between the groups. Patients at non‐TMVr centers had higher unadjusted in‐hospital mortality than those at TMVr centers (5.6% versus 3.6%, P <0.001). They also had higher rates of postoperative complications, longer hospitalizations, higher cost, and fewer home discharges but similar 30‐day readmission rates. After propensity matching, mortality remained higher at non‐TMVr centers (5.5% versus 4.0%, P <0.001). Rates of postoperative complications, prolonged hospitalizations, and nonhome discharges also remained higher. Postoperative mortality was consistently higher at non‐TMVr centers in multiple risk‐adjustment analyses incrementally accounting for differences in risk factors, surgical volume, availability of surgical repair, and excluding concomitant procedures. In the most comprehensive model, surgery at non‐TMVr centers was associated with higher odds of death (odds ratio, 1.41; 95% CI, 1.14–1.73; P =0.002). Conclusions Mitral valve surgery at TMVr centers is associated with improved in‐hospital outcomes compared with non‐TMVr centers.
Surgical and Transcatheter Mitral Valve Replacement in Mitral Annular Calcification: A Systematic Review
Alexis, Sophia L. , Malik, Aaqib H. , El‐Eshmawi, Ahmed, George, Isaac , Sengupta, Aditya , Kodali, Susheel , Hahn, Rebecca T. , Khalique, Omar , Zaid, Syed , Bapat, Vinayak , Leon, Martin B. , Tang, Gilbert H.L. , Hahn, Rebecca T , Guerrero, Mayra , Adams, David

Journal of the American Heart Association | March 17, 2021 | Volume: 10 | Issue: 7 | Pages: No page available

10.1161/jaha.120.018514 Get It

Abstract Mitral annular calcification with mitral valve disease is a challenging problem that could necessitate surgical mitral valve replacement (SMVR). Transcatheter mitral valve replacement (TMVR) is emerging as a feasible alternative in high‐risk patients with appropriate anatomy. PubMed, Embase, and Cochrane Central Register of Controlled Trials were searched from inception to December 25, 2019 for studies discussing SMVR or TMVR in patients with mitral annular calcification; 27 of 1539 articles were selected for final review. TMVR was used in 15 studies. Relevant data were available on 82 patients who underwent hybrid transatrial TMVR, and 354 patients who underwent transapical or transseptal TMVR. Outcomes on SMVR were generally reported as small case series (447 patients from 11 studies); however, 1 large study recently reported outcomes in 9551 patients. Patients who underwent TMVR had a shorter median follow‐up of 9 to 12 months (range, in‐hospital‒19 months) compared with patients with SMVR (54 months; range, in‐hospital‒120 months). Overall, those undergoing TMVR were older and had higher Society of Thoracic Surgeons risk scores. SMVR showed a wide range of early (0%–27%; median 6.3%) and long‐term mortality (0%–65%; median at 1 year, 15.8%; 5 years, 38.8%, 10 years, 62.4%). The median in‐hospital, 30‐day, and 1‐year mortality rates were 16.7%, 22.7%, and 43%, respectively, for transseptal/transapical TMVR, and 9.5%, 20.0%, and 40%, respectively, for transatrial TMVR. Mitral annular calcification is a complex disease and TMVR, with a versatile option of transatrial approach in patients with challenging anatomy, offers a promising alternative to SMVR in high‐risk patients. However, further studies are needed to improve technology, patient selection, operative expertise, and long‐term outcomes.