Back to Authors

Webb, John G.

https://orcid.org/0000-0001-7903-2870

Mayo Clinic

St. Paul's Hospital

Citations 16

Mortality prediction after transcatheter treatment of failed bioprosthetic aortic valves utilizing various international scoring systems: Insights from the Valve‐in‐Valve International Data (VIVID)
Aziz, Mina, Simonato, Matheus , Webb, John G. , Abdel‐Wahab, Mohamed , McElhinney, Doff B. , Duncan, Alison , Tchétché, Didier , Barbanti, Marco , Petronio, Anna Sonia , Maisano, Francesco , Ribeiro, Vasco Gama , Gaia, Diego Felipe , Rana, Ruhina , Kočka, Viktor , Mathur, Moses , Wijeysundera, Harindra C. , Hellig, Farrel, Bekeredjian, Raffi , Rihal, Charanjit S. , Dvir, Danny , Rihal, Charanjit, Maisano, Francesco , McElhinney, Doff B , Aziz, Mina, Nissen, Henrik , Rihal, Charanjit S. , Duffy, Stephen James

Catheterization and Cardiovascular Interventions | August 7, 2018 | Volume: 92 | Issue: 6 | Pages: 1163-1170

10.1002/ccd.27714 Get It

Abstract Background Transcatheter Aortic Valve Implantation (TAVI) is commonly used to deploy new bioprosthetic valves inside degenerated surgically implanted aortic valves in high risk patients. The three scoring systems used to assess risk of postprocedural mortality are: Logistic EuroSCORE (LES), EuroSCORE II (ES II), and Society of Thoracic Surgeons (STS). Objective The purpose of this study is to analyze the accuracy of LES, ES II, and STS in estimating all‐cause mortality after transcatheter aortic valve‐in‐valve (ViV) implantations, which was not assessed before. Methods Using the Valve‐in‐Valve International Data (VIVID) registry, a total of 1,550 patients from 110 centers were included. The study compared the observed 30‐day overall mortality vs. the respective predicted mortalities calculated by risk scores. The accuracy of prediction models was assessed based on calibration and discrimination. Results Observed mortality at 30 days was 5.3%, while average expected mortalities by LES, ES II and STS were 29.49 (± 17.2), 14.59 (± 8.6), and 9.61 (± 8.51), respectively. All three risk scores overestimated 30‐day mortality with ratios of 0.176 (95% CI 0.138–0.214), 0.342 (95% CI 0.264–0.419), and 0.536 (95% CI 0.421–0.651), respectively. 30‐day mortality ROC curves demonstrated that ES II had the largest AUC at 0.722, followed by STS at 0.704, and LES at 0.698. Conclusions All three scores overestimated mortality at 30 days with ES II showing the highest predictability compared to LES and STS; and therefore, should be recommended for ViV procedures. There is a need for a dedicated scoring system for patients undergoing ViV interventions.
Standardized Definition of Structural Valve Degeneration for Surgical and Transcatheter Bioprosthetic Aortic Valves
Dvir, Danny , Bourguignon, Thierry , Rosenhek, Raphaël , Webb, John G. , Treede, Hendrik , Enriquez‐Sarano, Maurice , Feldman, Ted , Wijeysundera, Harindra C. , Topilsky, Yan , Aupart, Michel, Reardon, Michael J. , Szeto, Wilson Y. , Gammie, James S. , Yoganathan, Ajit P. , Arbel, Yaron , Borger, Michael A. , Simonato, Matheus , Reisman, Mark, Makkar, Raj , Abizaid, Alexandre , Dahle, Gry , Aldea, Gabriel S. , Leipsic, Jonathon , Pîbarot, Philippe , Moat, Neil, Mack, Michael J. , Leon, Martin B. , Topilsky, Yan , Sarano, Maurice E, Pibarot, Phillippe , Enriquez-Sarano, Maurice , Otto, Catherine M , Hahn, Rebecca T , Mackensen, G. Burkhard , Kornowski, Ran , McCabe, James M , Kappetein, A. Pieter , Topilsky, Yan , Reardon, Michael J , Abizaid, Alexandre

Circulation | January 22, 2018 | Volume: 137 | Issue: 4 | Pages: 388-399

10.1161/circulationaha.117.030729 Get It

Bioprostheses are prone to structural valve degeneration, resulting in limited long-term durability. A significant challenge when comparing the durability of different types of bioprostheses is the lack of a standardized terminology for the definition of a degenerated valve. This issue becomes especially important when we try to compare the degeneration rate of surgically inserted and transcatheter bioprosthetic valves. This document, by the VIVID (Valve-in-Valve International Data), proposes practical and standardized definitions of valve degeneration and provides recommendations for the timing of clinical and imaging follow-up assessments accordingly. Its goal is to improve the quality of research and clinical care for patients with deteriorated bioprostheses by providing objective and strict criteria that can be utilized in future clinical trials. We hope that the adoption of these criteria by both the cardiological and surgical communities will lead to improved comparability and interpretation of durability analyses.
One-Year Clinical Outcomes With SAPIEN 3 Transcatheter Aortic Valve Replacement in High-Risk and Inoperable Patients With Severe Aortic Stenosis
Thourani, Vinod H. , Kodali, Susheel , Makkar, Raj , Szeto, Wilson Y. , Anwaruddin, Saif , Lim, Scott, Kereiakes, Dean J. , Ramee, Steven, Greason, Kevin L. , Kapadia, Samir , Babaliaros, Vasilis , Pîbarot, Philippe , Weissman, Neil J., Leipsic, Jonathon , Webb, John G. , Mack, Michael J. , Leon, Martin B. , Douglas, Pamela S. , Makkar, Raj R., Desai, Nimesh, Whisenant, Brian K, Herrmann, Howard C. , Desai, Nimesh D. , Malaisrie, S. Chris , Hahn, Rebecca T , Pibarot, Phillippe , Whisenant, Brian K. , Douglas, Pamela S

Circulation | July 12, 2016 | Volume: 134 | Issue: 2 | Pages: 130-140

10.1161/circulationaha.116.022797 Get It

Background: In the initial PARTNER trial (Placement of Aortic Transcatheter Valves) of transcatheter aortic valve replacement for high-risk (HR) and inoperable patients, mortality at 1 year was 24% in HR and 31% in inoperable patients. A recent report of the 30-day outcomes with the low-profile SAPIEN 3 transcatheter aortic valve replacement system demonstrated very low rates of adverse events, but little is known about the longer-term outcomes with this device. Methods: Between October 2013 and September 2014, 583 HR (65%) or inoperable (35%) patients were treated via the transfemoral (84%) or transapical/transaortic (16%) access route at 29 US sites. Major clinical events at 1 year were adjudicated by an independent clinical events committee, and echocardiographic results were analyzed by a core laboratory. Results: Baseline characteristics included age of 83 years, 42% female, and median Society of Thoracic Surgeons score of 8.4%. At the 1-year follow-up, survival (all-cause) was 85.6% for all patients, 87.3% in the HR subgroup, and 82.3% in the inoperable subgroup. Survival free of all-cause and cardiovascular mortality in the transfemoral patients from the HR cohort was 87.7% and 93.3%, respectively. There was no severe paravalvular leak. Moderate paravalvular leak (2.7%) was associated with an increase in mortality at 1 year, whereas mild paravalvular leak had no significant association with mortality. Symptomatic improvement as assessed by the percentage of patients in New York Heart Association class III and IV (90.1% to 7.7% at 1 year; P <0.0001) and by Kansas City Cardiomyopathy Questionnaire overall summary score (improved from 46.9 to 72.4; P <0.0001) was marked. Multivariable predictors of 1-year mortality included alternative access, Society of Thoracic Surgeons score, and disabling stroke. Conclusions: In this large, adjudicated registry of SAPIEN 3 HR and inoperable patients, the very low rates of important complications resulted in a strikingly low mortality rate at 1 year. Between 30 and 365 days, the incidence of moderate paravalvular aortic regurgitation did not increase, and no association between mild paravalvular leak and 1-year mortality was observed, although a small increase in disabling stroke occurred. These results, which likely reflect device iteration and procedural evolution, support the use of transcatheter aortic valve replacement as the preferred therapy in HR and inoperable patients with aortic stenosis. Clinical Trial Registration : URL: http://www.clinicaltrials.gov . Unique identifier: NCT01314313.
Transcatheter Tricuspid Valve-in-Valve Implantation for the Treatment of Dysfunctional Surgical Bioprosthetic Valves
McElhinney, Doff B. , Eicken, Andreas , Boudjemline, Younès , Schubert, Stephan , Himbert, Dominique , Asnes, Jeremy D. , Salizzoni, Stefano , Bocks, Martin L. , Momenah, Tarek , Kim, Dennis W. , Schranz, Dietmar, Meadows, Jeffery , Thomson, John , Goldstein, Bryan H. , Crittendon, Ivory, Fagan, Thomas E. , Webb, John G. , Horlick, Eric , Delaney, Jeffrey W., Jones, Thomas K. , Shahanavaz, Shabana , Moretti, Carolina, Hainstock, Michael , Kenny, Damien , Berger, Felix , Rihal, Charanjit S. , Dvir, Danny , Cabalka, Allison K. , Aboulhosn, Jamil A, Cheatham, John P. , Momenah, Tarek S, Thomson, John D R, Hainstock, Michael R, Kenny, Damien P, Aboulhosn, Jamil , Cheatham, John P. , Rihal, Charanjit S. , McElhinney, Doff B , Goldstein, Bryan H

Circulation | March 19, 2016 | Volume: 133 | Issue: 16 | Pages: 1582-1593

10.1161/circulationaha.115.019353 Get It

Background— Off-label use of transcatheter aortic and pulmonary valve prostheses for tricuspid valve-in-valve implantation (TVIV) within dysfunctional surgical tricuspid valve (TV) bioprostheses has been described in small reports. Methods and Results— An international, multicenter registry was developed to collect data on TVIV cases. Patient-related factors, procedural details and outcomes, and follow-up data were analyzed. Valve-in-ring or heterotopic TV implantation procedures were not included. Data were collected on 156 patients with bioprosthetic TV dysfunction who underwent catheterization with planned TVIV. The median age was 40 years, and 71% of patients were in New York Heart Association class III or IV. Among 152 patients in whom TVIV was attempted with a Melody (n=94) or Sapien (n=58) valve, implantation was successful in 150, with few serious complications. After TVIV, both the TV inflow gradient and tricuspid regurgitation grade improved significantly. During follow-up (median, 13.3 months), 22 patients died, 5 within 30 days; all 22 patients were in New York Heart Association class III or IV, and 9 were hospitalized before TVIV. There were 10 TV reinterventions, and 3 other patients had significant recurrent TV dysfunction. At follow-up, 77% of patients were in New York Heart Association class I or II ( P <0.001 versus before TVIV). Outcomes did not differ according to surgical valve size or TVIV valve type. Conclusions— TVIV with commercially available transcatheter prostheses is technically and clinically successful in patients of various ages across a wide range of valve size. Although preimplantation clinical status was associated with outcome, many patients in New York Heart Association class III or IV at baseline improved. TVIV should be considered a viable option for treatment of failing TV bioprostheses.
Risk stratification in patients with pulmonary hypertension undergoing transcatheter aortic valve replacement
Lindman, Brian R. , Zajarías, Alan , Maniar, Hersh S., Miller, D. Craig , Suri, Rakesh M. , Webb, John G. , Svensson, Lars G. , Kodali, Susheel , Xu, Ke , Ayele, Girma , Lin, Fay Y. , Wong, Shing–Chiu, Babaliaros, Vasilis , Thourani, Vinod H. , Douglas, Pamela S. , Lim, Scott, Leon, Martin B. , Mack, Michael J. , Arnold, Suzanne V. , Douglas, Pamela S , Lindman, Brian R

Heart | August 11, 2015 | Volume: 101 | Issue: 20 | Pages: 1656-1664

10.1136/heartjnl-2015-308001 Get It

Objective Pulmonary hypertension (PH) is associated with increased mortality after surgical or transcatheter aortic valve replacement (TAVR) for aortic stenosis (AS), and when the pulmonary artery pressure is particularly elevated, there may be questions about the clinical benefit of TAVR. We aimed to identify clinical and haemodynamic factors associated with increased mortality after TAVR among those with moderate/severe PH. Methods Among patients with symptomatic AS at high or prohibitive surgical risk receiving TAVR in the Placement of Aortic Transcatheter Valves (PARTNER) I randomised trial or registry, 2180 patients with an invasive measurement of mean pulmonary artery pressure (mPAP) recorded were included, and moderate/severe PH was defined as an mPAP ≥35 mm Hg. Results Increasing severity of PH was associated with progressively worse 1-year all-cause mortality: none (n=785, 18.6%), mild (n=838, 22.7%) and moderate/severe (n=557, 25.0%) (p=0.01). The increased hazard of mortality associated with moderate/severe PH was observed in females, but not males (interaction p=0.03). In adjusted analyses, females with moderate/severe PH had an increased hazard of death at 1 year compared with females without PH (adjusted HR 2.14, 95% CI 1.44 to 3.18), whereas those with mild PH did not. Among males, there was no increased hazard of death associated with any severity of PH. In a multivariable Cox model of patients with moderate/severe PH, oxygen-dependent lung disease, inability to perform a 6 min walk, impaired renal function and lower aortic valve mean gradient were independently associated with increased 1-year mortality (p<0.05 for all), whereas several haemodynamic indices were not. A risk score, including these factors, was able to identify patients with a 15% vs 59% 1-year mortality. Conclusions The relationship between moderate/severe PH and increased mortality after TAVR is altered by sex, and clinical factors appear to be more influential in stratifying risk than haemodynamic indices. These findings may have implications for the evaluation of and treatment decisions for patients referred for TAVR with significant PH. Trial registration NCT00530894.
Cardiopulmonary bypass and intra‐aortic balloon pump use is associated with higher short and long term mortality after transcatheter aortic valve replacement: A PARTNER trial substudy
Shreenivas, Satya , Lilly, Scott , Szeto, Wilson Y. , Anwaruddin, Saif , Bavaria, Joseph E. , Hudock, Kristin , Thourani, Vinod H. , Makkar, Raj , Pichard, Augusto D., Webb, John G. , Dewey, Todd, Suri, Rakesh M. , Xu, Ke , Leon, Martin B. , Desai, Nimesh D. , Kapadia, Samir , Herrmann, Howard C.

Catheterization and Cardiovascular Interventions | December 24, 2014 | Volume: 86 | Issue: 2 | Pages: 316-322

10.1002/ccd.25776 Get It

BackgroundTranscatheter aortic valve replacement (TAVR) with the balloon‐expandable Sapien transcatheter heart valve improves survival compared to standard therapy in patients with severe aortic stenosis (AS) and is noninferior to surgical aortic valve replacement (AVR) in patients at high operative risk. Nonetheless, a significant proportion of patients may require pre‐emptive or emergent support with cardiopulmonary bypass (CPB) and/or intra‐aortic balloon pump (IABP) during TAVR due to pre‐existing comorbid conditions or as a result of procedural complications. Objectives: We hypothesized that patients who required CPB or IABP would have increased periprocedural complications and reduced long‐term survival. In addition, we sought to determine whether preprocedural variables could predict the need for CPB and IABP. Methods: The study population included 2,525 patients in the PARTNER Trial (Cohort A and B) and the continuing access registry (CAR). Patients that received CPB or IABP were compared to patients that did not receive either, and then further divided into those that received support pre‐TAVR and those that were placed on support emergently. Results: One‐hundred sixty‐three patients (6.5%) were placed on CPB and/or IABP. The use of CPB or IABP was associated with higher 1 year mortality (49.1% vs. 21.6%, P < 0.001). In multivariable analysis, utilization of CPB or IABP was an independent predictor of 30 day (HR 6.95) and 1‐year (HR 2.56) mortality. Although mortality was highest in emergent cases, mortality was also greater in planned CPB and IABP cases compared with non‐CPB/IABP cases (53.3% and 40.3% vs. 21.6%, P < 0.001). Conclusions: These findings indicate that CPB and IABP use in TAVR portends a poor prognosis and its utilization, particularly in the setting of pre‐emptive use, needs reconsideration. © 2015 Wiley Periodicals, Inc.