Performance evaluation of single‐ and dual‐contrast spectral imaging on a photon‐counting‐detector CT
Ren, Liqiang , Zhou, Zhongxing , Ahmed, Zaki , Yu, Lifeng , Rajendran, Kishore , Fletcher, Joel G. , McCollough, Cynthia H. , Yu, Lifeng

Medical Physics | September 5, 2024 | Volume: 51 | Issue: 11 | Pages: 8034-8046

10.1002/mp.17367 Get It

AbstractBackgroundThe first commercially available photon‐counting‐detector CT (PCD‐CT) has been introduced for clinical use. However, its spectral performance on single‐ and dual‐contrast imaging tasks has not been comprehensively assessed.PurposeTo evaluate the spectral imaging performance of a clinical PCD‐CT system for single‐contrast material [iodine (I) or gadolinium (Gd)] and dual‐contrast materials (I and Gd) in comparison with a dual‐source dual‐energy CT (DS‐DECT).MethodsIodine (5, 10, and 15 mg/mL) and gadolinium (3.3, 6.6, and 9.9 mg/mL) samples, and their mixtures (I/Gd: 5/3.3 and 10/6.6 mg/mL) were prepared and placed in two torso‐shaped water phantoms (lateral dimensions: 30 and 40 cm). These phantoms were scanned on a PCD‐CT (NAEOTOM Alpha, Siemens) at 90, 120, and 140 kV. The same phantoms were scanned on a DS‐DECT (SOMATOM Force, Siemens) with 70/Sn150, 80/Sn150, 90/Sn150, and 100/Sn150 kV. The radiation dose levels were matched [volume CT dose index (CTDIvol): 10 mGy for the 30 cm phantom and 20 mGy for the 40 cm phantom] across all tube voltage settings and between scanners. Two‐material decomposition (I/water or Gd/water) was performed on iodine or gadolinium samples, and three‐material decomposition (I/Gd/water) on both individual samples and mixtures. On each decomposed image, mean mass concentration (± standard deviation) was measured in circular region‐of‐interests placed on the contrast samples. Root‐mean‐square‐error (RMSE) values of iodine and gadolinium concentrations were reported based on the measurements across all contrast samples and repeated on 10 consecutive slices.ResultsFor all material decomposition tasks on the DS‐DECT, the kV pairs with greater spectral separation (70/Sn150 kV and 80/Sn150 kV) yielded lower RMSE values than other DS‐DECT and PCD‐CT alternatives. Specifically, for the optimal 70/Sn150 kV, RMSE values were 1.2 ± 0.1 mg/mL (I) for I/water material decomposition, 1.0 ± 0.1 mg/mL (Gd) for Gd/water material decomposition, and 4.5 ± 0.2 mg/mL (I) and 3.7 ± 0.2 mg/mL (Gd), respectively, for I/Gd/water material decomposition. On the PCD‐CT, the optimal tube voltages were 120 or 140 kV for I/water decomposition with RMSE values of 2.0 ± 0.1 mg/mL (I). For Gd/water decomposition on PCD‐CT, the optimal tube voltage was 140 kV with gadolinium RMSE values of 1.5 ± 0.1 mg/mL (Gd), with the 90 kV setting on PCD‐CT generating higher RMSE values for gadolinium concentration compared to all DS‐DECT and PCD‐CT alternatives. For three material decomposition, both imaging modalities demonstrated substantially higher RMSE values for iodine and gadolinium, with 90 kV being the optimal tube potential for Gd/I quantitation on PCD‐CT [5.4 ± 0.3 mg/mL (I) and 3.9 ± 0.2 mg/mL (Gd)], and DS‐DECT at 100/Sn150 kV having larger RMSE values for both materials compared to the alternatives for either modality.ConclusionOptimal tube voltage for material decomposition on the clinical PCD‐CT is task‐dependent but inferior to DS‐DECT using 70/Sn150 kV or 80/Sn150 kV in two‐material decomposition for single‐contrast imaging (iodine/water or gadolinium/water). Three material decomposition (iodine/gadolinium/water) in dual‐contrast imaging yields substantially higher RMSE for both imaging platforms.
Simultaneous high‐pitch multi‐energy CT pulmonary angiography using a dual‐source photon‐counting‐detector CT: A phantom experiment
Bruesewitz, Michael R. , Swicklik, Joseph R., Yalon, Mariana , Yu, Lifeng , Mihailovic, Jelena M , Rajiah, Prabhakar S., Mihailović, Jelena M. , Rajiah, Prabhakar , Fletcher, Joel G. , McCollough, Cynthia H. , Yu, Lifeng

Journal of Applied Clinical Medical Physics | August 29, 2024 | Volume: 25 | Issue: 11 | Pages: No page available

10.1002/acm2.14496 Get It

AbstractPurposeA dual‐source CT system can be operated in a high‐pitch helical mode to provide a temporal resolution of 66 ms, which reduces motion artifacts in CT pulmonary angiography (CTPA). It can also be operated in a multi‐energy (ME) mode to provide iodine maps, beneficial in the evaluation of pulmonary embolism (PE). No energy‐integrating detector (EID) CT can perform simultaneous ME and high‐pitch acquisition. This phantom study aimed to evaluate the ability of a photon‐counting‐detector (PCD) CT to perform simultaneous high‐pitch and ME imaging for CTPA.MethodsA motion phantom was used to mimic the respiratory motion. Two tubes filled with iodine with intravascular thrombus mimicked by injecting glue within the tubes were placed along with 5, 10, and 15 mg/mL iodine samples, on a motion phantom at 20 and 30 revolutions per minute. Separate high‐pitch and ME EID‐CT scans and a single high‐pitch ME PCD scan were acquired and virtual monoenergetic images and iodine maps reconstructed. Percent thrombus occlusion was measured and compared between static and moving images.ResultsWhen there was motion, EID‐CT ME suffered from significant motion artifacts. The measured iodine concentrations with PCD‐CT in high‐pitch ME were more stable when there was a motion, with a lower standard deviation than EID‐CT in ME mode. The estimated percent thrombus occlusion dropped significantly with applied motion on EID‐CT, while PCD‐CT high‐pitch ME mode showed good agreement between measurements on static or moving images.ConclusionPCD‐CT with combined ME and high‐pitch mode facilitates simultaneous accurate iodine quantification and assessment of intravascular occlusion.
Development and validation of a noise insertion algorithm for photon‐counting‐detector CT
Winfree, Timothy, Yu, Lifeng , McCollough, Cynthia, McCollough, Cynthia H. , Yu, Lifeng

Medical Physics | June 23, 2024 | Volume: 51 | Issue: 9 | Pages: 5943-5953

10.1002/mp.17263 Get It

AbstractBackgroundInserting noise into existing patient projection data to simulate lower‐radiation‐dose exams has been frequently used in traditional energy‐integrating‐detector (EID)‐CT to optimize radiation dose in clinical protocols and to generate paired images for training deep‐learning‐based reconstruction and noise reduction methods. Recent introduction of photon counting detector CT (PCD‐CT) also requires such a method to accomplish these tasks. However, clinical PCD‐CT scanners often restrict the users access to the raw count data, exporting only the preprocessed, log‐normalized sinogram. Therefore, it remains a challenge to employ projection domain noise insertion algorithms on PCD‐CT.PurposeTo develop and validate a projection domain noise insertion algorithm for PCD‐CT that does not require access to the raw count data.Materials and MethodsA projection‐domain noise model developed originally for EID‐CT was adapted for PCD‐CT. This model requires, as input, a map of the incident number of photons at each detector pixel when no object is in the beam. To obtain the map of incident number of photons, air scans were acquired on a PCD‐CT scanner, then the noise equivalent photon number (NEPN) was calculated from the variance in the log normalized projection data of each scan. Additional air scans were acquired at various mA settings to investigate the impact of pulse pileup on the linearity of NEPN measurement. To validate the noise insertion algorithm, Noise Power Spectra (NPS) were generated from a 30 cm water tank scan and used to compare the noise texture and noise level of measured and simulated half dose and quarter dose images. An anthropomorphic thorax phantom was scanned with automatic exposure control, and noise levels at different slice locations were compared between simulated and measured half dose and quarter dose images. Spectral correlation between energy thresholds T1 and T2, and energy bins, B1 and B2, was compared between simulated and measured data across a wide range of tube current. Additionally, noise insertion was performed on a clinical patient case for qualitative assessment.ResultsThe NPS generated from simulated low dose water tank images showed similar shape and amplitude to that generated from the measured low dose images, differing by a maximum of 5.0% for half dose (HD) T1 images, 6.3% for HD T2 images, 4.1% for quarter dose (QD) T1 images, and 6.1% for QD T2 images. Noise versus slice measurements of the lung phantom showed comparable results between measured and simulated low dose images, with root mean square percent errors of 5.9%, 5.4%, 5.0%, and 4.6% for QD T1, HD T1, QD T2, and HD T2, respectively. NEPN measurements in air were linear up until 112 mA, after which pulse pileup effects significantly distort the air scan NEPN profile. Spectral correlation between T1 and T2 in simulation agreed well with that in the measured data in typical dose ranges.ConclusionsA projection‐domain noise insertion algorithm was developed and validated for PCD‐CT to synthesize low‐dose images from existing scans. It can be used for optimizing scanning protocols and generating paired images for training deep‐learning‐based methods.
Improved noise reduction in photon-counting detector CT using prior knowledge-aware iterative denoising neural network
Chang, Shaojie , Marsh, Jeffrey F., Koons, Emily K. , Gong, Hao , Leng, Shuai, McCollough, Cynthia H , Leng, Shuai , McCollough, Cynthia H. , Leng, Shuai

Journal of Medical Imaging | May 24, 2024 | Volume: 11 | Issue: S1 | Pages: No page available

10.1117/1.jmi.11.s1.s12804 Get It

Low-contrast detectability of photon-counting-detector CT at different scan modes and image types in comparison with energy-integrating-detector CT
Fan, Mingdong, Zhou, Zhongxing , Wellinghoff, Jarod , Yu, Lifeng , McCollough, Cynthia H , Yu, Lifeng , McCollough, Cynthia H.

Journal of Medical Imaging | May 23, 2024 | Volume: 11 | Issue: S1 | Pages: No page available

10.1117/1.jmi.11.s1.s12803 Get It

Multi-institutional Protocol Guidance for Pediatric Photon-counting CT
Horst, Kelly K. , Cao, Joseph , McCollough, Cynthia H. , El-Ali, Alex M., Siegel, Marilyn J. , Ramírez-Giraldo, Juan Carlos , O’Donnell, Tom, Bach, Steve, Yu, Lifeng , Cao, Joseph Y , El-Ali, Alex , Frush, Donald P , Siegel, Marilyn J , Ramirez-Giraldo, Juan Carlos , O'Donnell, Tom , Bache, Steve , Yu, Lifeng , McCollough, Cynthia H , Horst, Kelly , El‐Ali, Alexander M.

Radiology | May 21, 2024 | Volume: 311 | Issue: 2 | Pages: No page available

10.1148/radiol.231741 Get It

This article addresses clinical challenges of photon-counting detector (PCD) CT in pediatric patients by outlining fundamental terminology, explaining technical aspects, and providing protocol guidance for the first commercially available PCD CT scanner.
Task-based automatic keV selection: leveraging routine virtual monoenergetic imaging for dose reduction on clinical photon-counting detector CT *
Rajendran, Kishore , Bruesewitz, Michael R. , Swicklik, Joseph R., Ferrero, Andrea , Thorne, Jamison E. , Yu, Lifeng , Bruesewitz, Michael, Swicklik, Joseph, Thorne, Jamison, McCollough, Cynthia, Rajendran, Kishore , Yu, Lifeng , McCollough, Cynthia H. , Leng, Shuai

Physics in Medicine & Biology | April 22, 2024 | Volume: 69 | Issue: 11 | Pages: 115029

10.1088/1361-6560/ad41b3 Get It

Abstract Objective . Photon-counting detector (PCD) CT enables routine virtual-monoenergetic image (VMI) reconstruction. We evaluated the performance of an automatic VMI energy level (keV) selection tool on a clinical PCD-CT system in comparison to an automatic tube potential (kV) selection tool from an energy-integrating-detector (EID) CT system from the same manufacturer. Approach. Four torso-shaped phantoms (20–50 cm width) containing iodine (2, 5, and 10 mg cc −1 ) and calcium (100 mg cc −1 ) were scanned on PCD-CT and EID-CT. Dose optimization techniques, task-based VMI energy level and tube-potential selection on PCD-CT (CARE keV) and task-based tube potential selection on EID-CT (CARE kV), were enabled. CT numbers, image noise, and dose-normalized contrast-to-noise ratio (CNR d ) were compared. Main results . PCD-CT produced task-specific VMIs at 70, 65, 60, and 55 keV for non-contrast, bone, soft tissue with contrast, and vascular settings, respectively. A 120 kV tube potential was automatically selected on PCD-CT for all scans. In comparison, EID-CT used x-ray tube potentials from 80 to 150 kV based on imaging task and phantom size. PCD-CT achieved consistent dose reduction at 9%, 21% and 39% for bone, soft tissue with contrast, and vascular tasks relative to the non-contrast task, independent of phantom size. On EID-CT, dose reduction factor for contrast tasks relative to the non-contrast task ranged from a 65% decrease (vascular task, 70 kV, 20 cm phantom) to a 21% increase (soft tissue with contrast task, 150 kV, 50 cm phantom) due to size-specific tube potential adaptation. PCD-CT CNR d was equivalent to or higher than those of EID-CT for all tasks and phantom sizes, except for the vascular task with 20 cm phantom, where 70 kV EID-CT CNR d outperformed 55 keV PCD-CT images. Significance . PCD-CT produced more consistent CT numbers compared to EID-CT due to standardized VMI output, which greatly benefits standardization efforts and facilitates radiation dose reduction.
3D printed phantom with 12 000 submillimeter lesions to improve efficiency in CT detectability assessment
Shunhavanich, Picha , Shapira, Nadav , Gang, Grace J. , Geagan, Michael, Yu, Lifeng , Noël, Peter B. , Hsieh, Scott S. , Mei, Kai , Stayman, Joseph Webster , McCollough, Cynthia H. , Leng, Shuai , Yu, Lifeng

Medical Physics | April 8, 2024 | Volume: 51 | Issue: 5 | Pages: 3265-3274

10.1002/mp.17064 Get It

AbstractBackgroundThe detectability performance of a CT scanner is difficult to precisely quantify when nonlinearities are present in reconstruction. An efficient detectability assessment method that is sensitive to small effects of dose and scanner settings is desirable. We previously proposed a method using a search challenge instrument: a phantom is embedded with hundreds of lesions at random locations, and a model observer is used to detect lesions. Preliminary tests in simulation and a prototype showed promising results.PurposeIn this work, we fabricated a full‐size search challenge phantom with design updates, including changes to lesion size, contrast, and number, and studied our implementation by comparing the lesion detectability from a nonprewhitening (NPW) model observer between different reconstructions at different exposure levels, and by estimating the instrument sensitivity to detect changes in dose.MethodsDesigned to fit into QRM anthropomorphic phantoms, our search challenge phantom is a cylindrical insert 10 cm wide and 4 cm thick, embedded with 12 000 lesions (nominal width of 0.6 mm, height of 0.8 mm, and contrast of −350 HU), and was fabricated using PixelPrint, a 3D printing technique. The insert was scanned alone at a high dose to assess printing accuracy. To evaluate lesion detectability, the insert was placed in a QRM thorax phantom and scanned from 50 to 625 mAs with increments of 25 mAs, once per exposure level, and the average of all exposure levels was used as high‐dose reference. Scans were reconstructed with three different settings: filtered‐backprojection (FBP) with Br40 and Br59, and Sinogram Affirmed Iterative Reconstruction (SAFIRE) with strength level 5 and Br59 kernel. An NPW model observer was used to search for lesions, and detection performance of different settings were compared using area under the exponential transform of free response ROC curve (AUC). Using propagation of uncertainty, the sensitivity to changes in dose was estimated by the percent change in exposure due to one standard deviation of AUC, measured from 5 repeat scans at 100, 200, 300, and 400 mAs.ResultsThe printed insert lesions had an average position error of 0.20 mm compared to printing reference. As the exposure level increases from 50 mAs to 625 mAs, the lesion detectability AUCs increase from 0.38 to 0.92, 0.42 to 0.98, and 0.41 to 0.97 for FBP Br40, FBP Br59, and SAFIRE Br59, respectively, with a lower rate of increase at higher exposure level. FBP Br59 performed best with AUC 0.01 higher than SAFIRE Br59 on average and 0.07 higher than FBP Br40 (all P < 0.001). The standard deviation of AUC was less than 0.006, and the sensitivity to detect changes in mAs was within 2% for FBP Br59.ConclusionsOur 3D‐printed search challenge phantom with 12 000 submillimeter lesions, together with an NPW model observer, provide an efficient CT detectability assessment method that is sensitive to subtle effects in reconstruction and is sensitive to small changes in dose.
Image quality evaluation in deep‐learning‐based CT noise reduction using virtual imaging trial methods: Contrast‐dependent spatial resolution
Zhou, Zhongxing , Gong, Hao , Hsieh, Scott S. , Yu, Lifeng , Hsieh, Scott, McCollough, Cynthia H. , Yu, Lifeng

Medical Physics | March 31, 2024 | Volume: 51 | Issue: 8 | Pages: 5399-5413

10.1002/mp.17029 Get It

AbstractBackgroundDeep‐learning‐based image reconstruction and noise reduction methods (DLIR) have been increasingly deployed in clinical CT. Accurate image quality assessment of these methods is challenging as the performance measured using physical phantoms may not represent the true performance of DLIR in patients since DLIR is trained mostly on patient images.PurposeIn this work, we aim to develop a patient‐data‐based virtual imaging trial framework and, as a first application, use it to measure the spatial resolution properties of a DLIR method.MethodsThe patient‐data‐based virtual imaging trial framework consists of five steps: (1) insertion of lesions into projection domain data using the acquisition geometry of the patient exam to simulate different lesion characteristics; (2) insertion of noise into projection domain data using a realistic photon statistical model of the CT system to simulate different dose levels; (3) creation of DLIR‐processed images from projection or image data; (4) creation of ensembles of DLIR‐processed patient images from a large number of noise and lesion realizations; and (5) evaluation of image quality using ensemble DLIR images. This framework was applied to measure the spatial resolution of a ResNet based deep convolutional neural network (DCNN) trained on patient images. Lesions in a cylindrical shape and different contrast levels (−500, −100, −50, −20, −10 HU) were inserted to the lower right lobe of the liver in a patient case. Multiple dose levels were simulated (50%, 25%, 12.5%). Each lesion and dose condition had 600 noise realizations. Multiple reconstruction and denoising methods were used on all the noise realizations, including the original filtered‐backprojection (FBP), iterative reconstruction (IR), and the DCNN method with three different strength setting (DCNN‐weak, DCNN‐medium, and DCNN‐strong). Mean lesion signal was calculated by performing ensemble averaging of all the noise realizations for each lesion and dose condition and then subtracting the lesion‐present images from the lesion absent images. Modulation transfer functions (MTFs) both in‐plane and along the z‐axis were calculated based on the mean lesion signals. The standard deviations of MTFs at each condition were estimated with bootstrapping: randomly sampling (with replacement) all the DLIR/FBP/IR images from the ensemble data (600 samples) at each condition. The impact of varying lesion contrast, dose levels, and denoising strengths were evaluated. Statistical analysis with paired t‐test was used to compare the z‐axis and in‐plane spatial resolution of five algorithms for five different contrasts and three dose levels.ResultsThe in‐plane and z‐axis spatial resolution degradation of DCNN becomes more severe as the contrast or radiation dose decreased, or DCNN denoising strength increased. In comparison with FBP, a 59.5% and 4.1% reduction of in‐plane and z‐axis MTF (in terms of spatial frequencies at 50% MTF), respectively, was observed at low contrast (−10 HU) for DCNN with the highest denoising strength at 25% routine dose level. When the dose level reduces from 50% to 12.5% of routine dose, the in‐plane and z‐axis MTFs reduces from 92.1% to 76.3%, and from 98.9% to 95.5%, respectively, at contrast of −100 HU, using FBP as the reference. For most conditions of contrasts and dose levels, significant differences were found among the five algorithms, with the following relationship in both in‐plane and cross‐plane spatial resolution: FBP > DCNN‐Weak > IR > DCNN‐Medium > DCNN‐Strong. The spatial resolution difference among algorithms decreases at higher contrast or dose levels.ConclusionsA patient‐data‐based virtual imaging trial framework was developed and applied to measuring the spatial resolution properties of a DCNN noise reduction method at different contrast and dose levels using real patient data. As with other non‐linear image reconstruction and post‐processing techniques, the evaluated DCNN method degraded the in‐plane and z‐axis spatial resolution at lower contrast levels, lower radiation dose, and higher denoising strength.
Photon-counting CT in Thoracic Imaging: Early Clinical Evidence and Incorporation Into Clinical Practice
Fletcher, Joel G. , Bratt, Alex , Horst, Kelly K. , Koo, Chi Wan , Baffour, Francis , Ko, Jane P. , Rémy‐Jardin, Martine , McCollough, Cynthia H. , Yu, Lifeng , Bratt, Alex , Horst, Kelly , Koo, Chi Wan , Rajiah, Prabhakar Shantha, Baffour, Francis I , Remy-Jardin, Martine , McCollough, Cynthia H , Yu, Lifeng , Fletcher, Joel G , Inoue, Akitoshi , Rajiah, Prabhakar

Radiology | March 19, 2024 | Volume: 310 | Issue: 3 | Pages: No page available

10.1148/radiol.231986 Get It