Abstract INTRODUCTION Cognition is reduced at low and high glucose, reflecting cognitive vulnerability to glucose (CVG) fluctuations. The impact of glucose fluctuations on the aging brain remains unclear. We examined whether CVG is associated with plasma biomarkers of Alzheimer's disease (AD) pathology and neurodegeneration. METHODS Participants included N = 114 adults with type 1 diabetes assessed for processing speed and sustained attention using ecological momentary assessment (EMA) combined with continuous glucose monitoring (CGM). We characterized associations between CVG and amyloid beta (Aβ) 42/40, phosphorylated tau (p‐tau) 181 and 217, neurofilament light chain, and glial fibrillary acidic protein. RESULTS CVG was associated with all plasma biomarkers, except Aβ 42/40. CVG for sustained attention exhibited strong associations with p‐tau biomarkers that persisted across covariate specifications. DISCUSSION CVG may be a useful digital phenotype of AD. It remains unclear whether CVG contributes to versus arises from neurodegeneration. We consider possible mechanisms linking cognitive vulnerability and long‐term glucose variability to the development of neuropathology. Highlights Cognitive vulnerability to glucose (CVG) may be a useful digital phenotype of neurodegeneration. We used cognitive ecological momentary assessment and continuous glucose monitoring to investigate CVG's associations with plasma biomarkers. Associations of CVG for sustained attention and phosphorylated tau 181 remained significant across covariates. We discuss possible mechanisms relating glucose variability, cognition, and neurodegeneration.
Automated Insulin Delivery in Older Adults with Type 1 Diabetes
OBJECTIVE To evaluate a regimen of inhaled Technosphere insulin (TI) plus insulin degludec in adults with type 1 diabetes, who prestudy were predominately using either an automated insulin delivery (AID) system or multiple daily insulin injections (MDI) with continuous glucose monitoring. RESEARCH DESIGN AND METHODS At 19 sites, adults with type 1 diabetes were randomly assigned to TI plus insulin degludec (N = 62) or usual care (UC) with continuation of prestudy insulin delivery method (N = 61) for 17 weeks. RESULTS Prestudy, AID was used by 48% and MDI by 45%. Mean ± SD HbA1c was 7.57% ± 0.97% at baseline and 7.62% ± 1.06% at 17 weeks in the TI group and 7.59% ± 0.80% and 7.54% ± 0.77%, respectively, in the UC group (adjusted difference 0.11%, 95% CI −0.10 to 0.33, P value for noninferiority = 0.01). HbA1c improved from baseline to 17 weeks by >0.5% (5.5 mmol/mol) in 12 (21%) in the TI group and in 3 (5%) in the UC group and worsened by >0.5% (5.5 mmol/mol) in 15 (26%) in the TI group and in 2 (3%) in the UC group. The most common TI side effect was a brief cough; eight participants discontinued TI due to side effects. CONCLUSIONS In adults with type 1 diabetes, HbA1c after 17 weeks with a regimen of TI and degludec was noninferior to UC, which consisted predominately of either AID or MDI. TI should be considered an option for people with type 1 diabetes, particularly those who are motivated to further reduce postprandial hyperglycemia.
A Randomized Comparison of Postprandial Glucose Excursion Using Inhaled Insulin Versus Rapid-Acting Analog Insulin in Adults With Type 1 Diabetes Using Multiple Daily Injections of Insulin or Automated Insulin Delivery
OBJECTIVE To compare postprandial glucose excursions following a bolus with inhaled technosphere insulin (TI) or subcutaneous rapid-acting analog (RAA) insulin. RESEARCH DESIGN AND METHODS A meal challenge was completed by 122 adults with type 1 diabetes who were using multiple daily injections (MDI), a nonautomated pump, or automated insulin delivery (AID) and who were randomized to bolus with their usual RAA insulin (n = 61) or TI (n = 61). RESULTS The primary outcome, the treatment group difference in area under the curve for glucose >180 mg/dL over 2 h, was less with TI versus RAA (adjusted difference −12 mg/dL, 95% CI −22 to −2, P = 0.02). With TI, the glucose excursion was smaller (P = 0.01), peak glucose lower (P = 0.01), and time to peak glucose shorter (P = 0.006). Blood glucose <70 mg/dL occurred in one participant in each group. CONCLUSIONS Postmeal glucose excursion was smaller with TI than with RAA insulin in a cohort that included both AID and MDI users.
Concordance of Blood Glucose and CGM During a Pilot Trial of Automated Insulin Delivery in Type 1 Diabetes Pregnancies
Abstract Background Customized and standard automated insulin delivery (AID) systems for use in pregnancies of women with preexisting type 1 diabetes (T1D) are being developed and tested to achieve pregnancy appropriate continuous glucose monitoring (CGM) targets. Guidance on the use of CGM for treatment decisions during pregnancy in the United States is limited. Methods Ten pregnant women with preexisting T1D participated in a trial evaluating at-home use of a pregnancy-specific AID system. Seven-point self-monitoring of blood glucose (SMBG) was compared to the closest sensor glucose (Dexcom G6 CGM) value biweekly to assess safety and reliability based on the 20%/20 mg/dL criteria. Results All participants completed the study with 7 participants satisfying the safety and reliability criteria with a mean absolute relative difference of 10.3%. Three participants did not fulfill the criteria, mainly because the frequency of SMBG did not meet the requirements. Conclusion Dexcom G6 CGM is safe and accurate in the real-world setting for use in pregnant women with preexisting T1D with reduced SMBG testing as part of a pregnancy-specific AID system.
Impact of pancreas transplantation alone on kidney function: A multicenter clinical cohort study
AbstractPancreas transplantation alone (PTA) is a β cell replacement option for selected patients with type 1 diabetes mellitus; concerns have been raised regarding deterioration in kidney function (KF) after PTA. This retrospective multicenter study assessed actual impact of transplantation and immunosuppression on KF in PTA recipients at three Transplant Centers. The primary composite endpoint 10 years after PTA was >50% eGFR decline, eGFR < 30 mL/min/1.73 m2, and/or receiving a kidney transplant (KT). Overall, 822 PTA recipients met eligibility. Median baseline and 10‐year eGFR (mL/min/1.73 m2) were 76.3 (58.1–100.8) and 51.3 (35.3–65.9), respectively. Primary composite endpoint occurred in 98 patients (53.5%) with 45 experiencing a >50% decrease in eGFR by 10 years post‐transplant, 38 eGFR < 30 mL/min/1.73 m2 and 49 requiring KT. KF declined most significantly within 6 months post‐PTA, more often in females and patients with better preserved GFR up to 5 years with 11.6% kidney failure at 10 years. Patient survival and death‐censored graft survival were both 68% at 10 years with overall graft thrombosis rate 8%. KF declined initially after PTA but stabilized with further slow progression. In conclusion, prospective intervention studies are needed to test renal sparing interventions while gathering more granular data.
At-Home Use of a Pregnancy-Specific Zone-MPC Closed-Loop System for Pregnancies Complicated by Type 1 Diabetes: A Single-Arm, Observational Multicenter Study
OBJECTIVE There are no commercially available hybrid closed-loop insulin delivery systems customized to achieve pregnancy-specific glucose targets in the U.S. This study aimed to evaluate the feasibility and performance of at-home use of a zone model predictive controller–based closed-loop insulin delivery system customized for pregnancies complicated by type 1 diabetes (CLC-P). RESEARCH DESIGN AND METHODS Pregnant women with type 1 diabetes using insulin pumps were enrolled in the second or early third trimester. After study sensor wear collecting run-in data on personal pump therapy and 2 days of supervised training, participants used CLC-P targeting 80–110 mg/dL during the day and 80–100 mg/dL overnight running on an unlocked smartphone at home. Meals and activities were unrestricted throughout the trial. The primary outcome was the continuous glucose monitoring percentage of time in the target range 63–140 mg/dL versus run-in. RESULTS Ten participants (HbA1c 5.8 ± 0.6%) used the system from mean gestational age of 23.7 ± 3.5 weeks. Mean percentage time in range increased 14.1 percentage points, equivalent to 3.4 h per day, compared with run-in (run-in 64.5 ± 16.3% versus CLC-P 78.6 ± 9.2%; P = 0.002). During CLC-P use, there was significant decrease in both time over 140 mg/dL (P = 0.033) and the hypoglycemic ranges of less than 63 mg/dL and 54 mg/dL (P = 0.037 for both). Nine participants exceeded consensus goals of above 70% time in range during CLC-P use. CONCLUSIONS The results show that the extended use of CLC-P at home until delivery is feasible. Larger, randomized studies are needed to further evaluate system efficacy and pregnancy outcomes.
P.155: Altered T Cell Compartment in Type 1 Diabetes With End Stage Renal Disease