Abstract Older adults with dementia account over 15% of intensive care unit (ICU) admissions and face higher risks of functional decline and complications. We systematically evaluated the difference in ICU-related outcomes in patients with and without dementia, (e.g., mortality, resuscitation and code status decisions, complications, duration of life support and hospital stay). Searches were performed in MEDLINE, EMBASE, SCOPUS, and Web of Science between 2003 and 2024. A random-effects meta-analysis was done of odds ratios (OR) and mean differences (MD) and their corresponding 95% confidence intervals (CI) were calculated. Fifteen studies, including 1,231,037 patients (12% with dementia), met the inclusion criteria. Adjusted analysis showed that patients with dementia had a higher risk of ICU mortality (OR = 1.05, 95% CI 1.00–1.11), 30-day mortality (OR = 1.54, 95% CI 1.47–1.62) and 12-month mortality (OR = 1.95, 95% CI 1.88–2.02). They were less likely to receive mechanical ventilation (OR = 0.73, 95% CI 0.62–0.85, I2 0.0%) and more likely to develop delirium (OR = 4.80, 95% CI 1.81–12.72). In patients with dementia, ICU stays were slightly shorter (MD = –1 day, 95% CI –1.7 to –0.4), and discharge home was less common (OR = 0.40, 95% CI 0.39–0.42). Older adults with dementia experienced greater risk of mortality and delirium, alongside less aggressive intervention use and healthcare utilization (i.e., shorter ICU stays). These findings underscore the need for prospective studies to optimize ICU decision-making and post-discharge care for this vulnerable population.
Living liver donor safety: Early postoperative considerations of living liver donation guidelines from the ILTS-iLDLTG consensus conference
Living donor liver transplantation (LDLT) is a life-saving procedure for patients with end-stage liver disease. As its use expands worldwide, ensuring the safety and well-being of live liver donors (LLD) is of paramount importance. Published evidence on early postoperative complications after living donor hepatectomy—those occurring within 90 days of surgery—is limited, and standardized postoperative care protocols are lacking. The International Liver Transplantation Society (ILTS) and the International Living Donor Liver Transplantation Group (iLDLT Group) convened a consensus conference in Toronto in March 2025 to develop guidelines for the safe care of the LLDs. This manuscript details the recommendations on early postoperative considerations for the safety of LLDs developed by Working Group III (WGIII) of the Consensus Scientific Committee, using the Grading of Recommendations, Assessment, Development, and Evaluation (GRADE) system for assessment of recommendations, and the Danish model of consensus. WGIII addressed four key areas: (1) standardized postoperative care, (2) early biliary complications, (3) early postoperative liver dysfunction, and (4) early postdischarge follow-up. This report emphasizes the need for vigilant postoperative monitoring in specialized units, with access to experienced providers and defined clinical pathways. Structured clinical and psychosocial follow-up protocols, perioperative prophylaxis for surgical site infections and venous thromboembolism, and management of early biliary and vascular complications are discussed. These may help standardize care, reduce complications and improve short-term outcomes in LLDs.
Abstract The sections in this article are: Why is Stress Distribution Nonuniform? Why is it Important to Know Stress Distribution? Simplifications Introduced to Analysis of Stress Distribution Relationship Between Microscopic Structure and Macroscopic Properties Material Properties of Lung Parenchyma Meaning of Other Elastic Constants Implications of Relative Magnitudes of Bulk and Shear Moduli Macroscopic Lung Stress Distribution Local Stress Distribution
Technical performance of dual‐contrast‐agent K‐edge imaging with four energy thresholds on a commercial photon counting detector CT
Abstract Background Photon counting detector CT (PCD‐CT) has the potential to sort detected x‐ray photons into more than two energy bins to perform multi‐material decomposition using K‐edge materials without additional mathematical constraints/assumptions. The availability of multiple energy thresholds in PCD‐CT opens the possibility for unique clinical applications such as simultaneous multi‐contrast‐agent imaging. Purpose To evaluate the technical performance of a PCD‐CT system with four energy thresholds for conducting multi‐material decomposition of iodine, gadolinium, and water after a comprehensive system calibration procedure. Methods Experiments were performed on a commercial PCD‐CT scanner (NAEOTOM Alpha, Siemens Healthineers) using a research mode with four energy thresholds. Material calibration was performed by scanning contrast materials with known concentration placed in various sizes of cylindrical water‐equivalent phantoms at various tube currents and positions. From these data, per‐voxel contrast models were derived for each material by multiple linear regressions up to second order, where the predictor variables were combinations of tube current, phantom diameter, and distance to isocenter. After calibration, small (20 cm diameter) and large (30 cm × 40 cm) uniform multi‐energy CT phantoms and an anthropomorphic thorax phantom (31 cm × 39 cm), each containing bone, soft tissue, and several quantitative inserts of iodine (0.2–5.0 mg/ml), gadolinium (0.3–5.0 mg/ml), and a mixture of both (5.0 mg/ml each) were scanned using the four‐energy threshold mode at 140 kV with energy thresholds set at 20, 52, 75, and 82 keV. Images for each energy threshold were reconstructed with a filtered back‐projection algorithm and a quantitative kernel (Qr44). Subsequent image‐based material decomposition was performed on individual voxels of the energy threshold images using the models derived from the calibration process to generate water, iodine, and gadolinium basis images. Quantitative material concentrations and image noise magnitudes, and noise power spectra (NPS) were measured. Results Iodine and gadolinium concentrations above 1.25 mg/ml were visible in the material basis images in all phantoms. Averaged quantitative accuracy for iodine and gadolinium in the small, large, and thorax phantoms were 0.39 ± 0.30 mg/ml, 0.96 ± 0.53 mg/ml, and 0.53 ± 0.35 mg/ml, respectively. In the water basis images, accuracy was within 24 HU in all phantoms. Noise magnitudes in iodine and gadolinium basis images were 2.91 and 3.52 times that of the lowest energy threshold image for the small phantom, and were 6.92 and 7.17 times that of the lowest threshold image for the large phantom. Noise texture did not change between the energy threshold and material basis images for either size phantom as measured by the NPS. Conclusions After a comprehensive system calibration, a commercial PCD‐CT with four energy thresholds performed multiple material decomposition of iodine, gadolinium, and water for concentrations above 1.25 mg/ml in human‐sized phantoms. Noise amplification and quantitative accuracy from the decomposition greatly depended on object size.
Cost-Effectiveness Analysis of Mepitel Film for Prevention of Acute Radiation Dermatitis in Breast Cancer: a Canadian Healthcare Perspective
Abstract Introduction While randomized clinical trials (RCT) confirmed superiority of Mepitel film (MF) in reducing acute radiation dermatitis (ARD) compared to standard-of-care (SoC), the incremental cost difference has limited its use. A cost-effectiveness analysis (CEA) was conducted from a Canadian healthcare payer’s perspective to guide policy decisions. Methods: A decision model was constructed to perform a CEA for MF compared to SoC (moisturisers) for prevention of grade 2 or higher ARD following adjuvant hypo-fractionated whole-breast radiotherapy (RT) based on a Canadian multicentre RCT. Direct and indirect cost data were collected from two oncology centres in Canada. Quality-of-life (QoL) utility values were derived from mapping Dermatology Life Quality Index (DLQI) scores for patients with grade 2 or higher ARD at week 6 of RT to EQ-5D. A willingness-to-pay (WTF) threshold of CAD 50,000 per quality-adjusted life years (QALY) gained was used. One-way sensitivity analysis was performed to account for uncertainty in decision model assumptions. Results: Base case analysis demonstrated that MF is cost-effective in preventing grade 2 or higher ARD as compared with SoC with an incremental cost-effectiveness ratio (ICER) of CAD 3,366 per QALY gained. When nursing costs were included, MF resulted in an ICER of CAD 2,823 per QALY gained. One-way sensitivity analysis showed that the results were most sensitive to the QoL utility value for ARD. All sensitivity variations remained well below the WTP threshold. Conclusions: MF is a cost-effective intervention for preventing high-grade ARD and should be recommended for patients with breast cancer undergoing adjuvant RT.
Lifetime Risk of First Symptomatic ICH or Seizure in Familial Cerebral Cavernous Malformations
Background: In the emergency setting, many diagnostic pathways incorporate change in high-sensitivity cardiac troponin (hs-cTn) concentrations (i.e., the delta) to classify patients as low-risk (rule-out) or high-risk (rule-in) for possible myocardial infarction (MI). However, the impact of analytical variation on the delta for correct classification is unknown, especially at concentrations below and around the 99th percentile. Our objective was to assess the impact of delta variation for correct risk classification across the European Society of Cardiology (ESC 0/1 h and 0/2 h), the High-STEACS, and the common change criteria (3C) pathways. Methods: A yearlong accuracy study for hs-cTnT was performed where laboratories across Canada tested three patient-based samples (level 1 target value = 6 ng/L, level 2 target value = 9 ng/L, level 3 target value = 12 ng/L) monthly across 41 different analyzers. The assigned low-delta between levels 1 and 2 was 3 ng/L (i.e., 9 − 6 = 3 ng/L) and the assigned high-delta between levels 1 and 3 was 6 ng/L (i.e., 12 − 6 = 6 ng/L). The low- and high-deltas for each analyzer were determined monthly from the measured values, with the difference calculated from the assigned deltas. The obtained deltas were then assessed via the different pathways on correct classification (i.e., percent correct with 95% confidence intervals, CI) and using non-parametric analyses. Results: The median (interquartile range) difference between the measured versus assigned low-delta (n = 436) and high-delta (n = 439) was −1 ng/L (−1 to 0). The correct classification differed among the pathways. The ESC 0/1 h pathway yielded the lowest percentage of correct classification at 35.3% (95% CI: 30.8 to 40.0) for the low-delta and 90.0% (95% CI: 86.8 to 92.6) for the high-delta. The 3C and ESC 0/2 h pathways yielded higher and equivalent estimates on correct classification: 95.2% (95% CI: 92.7 to 97.0) for the low-delta and 98.2% (95% CI: 96.4 to 99.2) for the high-delta. The High-STEACS pathway yielded 99.5% (95% CI: 98.4 to 99.9) of correct classifications for the high-delta but only 36.2% (95% CI: 31.7 to 40.9) for the low-delta. Conclusions: Analytical variation will impact risk classification for MI when using hs-cTn deltas alone per the pathways. The 3C and ESC 0/2 h pathways have <5% misclassification when using deltas for hs-cTnT in this dataset. Additional studies with different hs-cTnI assays at concentrations below and near the 99th percentile are warranted to confirm these findings.
The Brain Tumor Segmentation (BraTS-METS) Challenge 2023: Brain Metastasis Segmentation on Pre-treatment MRI
The translation of AI-generated brain metastases (BM) segmentation into clinical practice relies heavily on diverse, high-quality annotated medical imaging datasets. The BraTS-METS 2023 challenge has gained momentum for testing and benchmarking algorithms using rigorously annotated internationally compiled real-world datasets. This study presents the results of the segmentation challenge and characterizes the challenging cases that impacted the performance of the winning algorithms. Untreated brain metastases on standard anatomic MRI sequences (T1, T2, FLAIR, T1PG) from eight contributed international datasets were annotated in stepwise method: published UNET algorithms, student, neuroradiologist, final approver neuroradiologist. Segmentations were ranked based on lesion-wise Dice and Hausdorff distance (HD95) scores. False positives (FP) and false negatives (FN) were rigorously penalized, receiving a score of 0 for Dice and a fixed penalty of 374 for HD95. The mean scores for the teams were calculated. Eight datasets comprising 1303 studies were annotated, with 402 studies (3076 lesions) released on Synapse as publicly available datasets to challenge competitors. Additionally, 31 studies (139 lesions) were held out for validation, and 59 studies (218 lesions) were used for testing. Segmentation accuracy was measured as rank across subjects, with the winning team achieving a LesionWise mean score of 7.9. The Dice score for the winning team was 0.65 ± 0.25. Common errors among the leading teams included false negatives for small lesions and misregistration of masks in space. The Dice scores and lesion detection rates of all algorithms diminished with decreasing tumor size, particularly for tumors smaller than 100 mm3. In conclusion, algorithms for BM segmentation require further refinement to balance high sensitivity in lesion detection with the minimization of false positives and negatives. The BraTS-METS 2023 challenge successfully curated well- annotated, diverse datasets and identified common errors, facilitating the translation of BM segmentation across varied environments and providing the tools for future development of personalized volumetric reports to patients undergoing BM treatment.
Comparing FIB-4, VCTE, pSWE, 2D-SWE, and MRE Thresholds and Diagnostic Accuracies for Detecting Hepatic Fibrosis in Patients with MASLD: A Systematic Review and Meta-Analysis
Objectives: To compare thresholds and accuracies of FIB-4, vibration-controlled transient elastography (VCTE), point shear wave elastography (pSWE), 2D shear wave elastography (2D-SWE), and MR elastography (MRE) for detecting hepatic fibrosis in patients with MASLD. Materials and Methods: Systematic searching of MEDLINE, EMBASE, Cochrane Library, Scopus, and the gray literature from inception to March 2024 was performed. Studies evaluating accuracies of FIB-4, VCTE, 2D-SWE, pSWE, and/or MRE for detecting significant (≥F2) and/or advanced (≥F3) hepatic fibrosis in MASLD patients compared to histology were identified. Full-text review and data extraction were performed independently by two reviewers. Multivariate meta-analysis and subgroup analyses were performed using index test and fibrosis grading. Risk of bias was assessed using QUADAS-2. Results: 207 studies with over 80,000 patient investigations were included. FIB-4 1.3 threshold sensitivity was 71% (95% CI 66–75%) for detecting advanced hepatic fibrosis, which improved to 88% (85–91%) using a <0.75 threshold. FIB-4 specificity using a 2.67 threshold was 96% (94–97%). Sensitivities of 88–91% were achieved using thresholds of 3.2 kPa for pSWE, 4.92 kPa for 2D-SWE, 7.18 kPa for VCTE, and 2.32 kPa for MRE. No significant differences were identified for sensitivities in subgroup analysis with thresholds between 7 and 9 kPa. Most imaging-based studies were high risk of bias for the index test. Conclusions: A FIB-4 threshold of <0.75 and modality-dependent thresholds (VCTE < 7 kPa; pSWE <3 kPa; 2D-SWE <5 kPa; and MRE <2.5 kPa) would achieve sensitivities of around 90% when defining low-risk MASLD in population screening. A modified two-tier algorithm aligning with existing Society of Radiologists in Ultrasound guidelines would improve risk stratification accuracies compared to existing guidelines by European and American liver societies.
FGFR1
fusions in genomically and epigenetically bona fide glioblastoma, IDH-wildtype