Citations

Mayo Clinic

Clear

192 citation(s) found for "Fu, Shuai".

Reduction of Metal Artifacts and Improvement in Dose Efficiency Using Photon-Counting Detector Computed Tomography and Tin Filtration
Zhou, Wei , Bartlett, David J. , Glazebrook, Katrina N. , Carter, Rickey E. , Zhou, Wei , Carter, Rickey E , Diehn, Felix E. , Kotsenas, Amy L. , Fletcher, Joel G. , McCollough, Cynthia H. , Leng, Shuai

Investigative Radiology | December 18, 2018 | Volume: 54 | Issue: 4 | Pages: 204-211

10.1097/rli.0000000000000535 | PMID 30562270 Get It

Objectives The aim of this study was to investigate the impact on metal artifacts and dose efficiency of using a tin filter in combination with high-energy threshold (TH) images of a photon-counting detector (PCD) computed tomography (CT) system. Materials and Methods A 3D-printed spine with pedicle screws was scanned on a PCD-CT system with and without tin filtration. Image noise and severity of artifacts were measured for low-energy threshold (TL) and TH images. In a prospective, institutional review board–approved, Health Insurance Portability and Accountability Act-compliant study, 20 patients having a clinical energy-integrating detector (EID) CT were scanned on a PCD-CT system using tin filtration. Images were reviewed by 3 radiologists to evaluate visualization of anatomic structures, diagnostic confidence, and image preference. Artifact severity and image noise were measured. Wilcoxon signed rank was used to test differences between PCD-CT TH and EID-CT images. Results Phantom TH images with tin filtration reduced metal artifacts and had comparable noise (32 HU) to TL images (29 HU) acquired without tin filtration. Visualization scores for the cortex, trabeculae, and implant-trabecular interface from PCD-CT TH images (4.4 ± 0.9, 4.4 ± 1.0, and 4.4 ± 1.0) were significantly higher (P < 0.0001) than EID-CT images (3.3 ± 1.3, 3.3 ± 1.2, and 3.3 ± 1.6). A strong preference was shown for PCD-CT TH images due to improved diagnostic confidence and decreased artifact severity. Noise in PCD-CT TH images (93 ± 41 HU) was significantly lower than that in EID-CT images (133 ± 92 HU, P < 0.05). Conclusions Threshold high images acquired with tin filtration on PCD-CT demonstrated a substantial decrease in metal artifacts and an increase in dose efficiency compared with EID-CT.
Evaluation of a photon counting Medipix3RX cadmium zinc telluride spectral x-ray detector
Marsh, Jeffrey F., Jorgensen, Steven M., Rundle, David S., Vercnocke, Andrew J. , Butler, Philip H. , Ritman, Erik L., Leng, Shuai , Butler, Philip H , McCollough, Cynthia H , Leng, Shuai , McCollough, Cynthia H.

Journal of Medical Imaging | December 4, 2018 | Volume: 5 | Issue: 04 | Pages: 1

10.1117/1.jmi.5.4.043503 | PMID 30840738 Get It

High-Resolution Chest Computed Tomography Imaging of the Lungs
Bartlett, David J. , Koo, Chi Wan , Bartholmai, Brian J. , Weaver, Jayse , Halaweish, Ahmed F., Bartholmai, Brian J , Rajendran, Kishore , Leng, Shuai , McCollough, Cynthia H. , Fletcher, Joel G.

Investigative Radiology | November 21, 2018 | Volume: 54 | Issue: 3 | Pages: 129-137

10.1097/rli.0000000000000524 | PMID 30461437 Get It

Objectives The aim of this study was to evaluate if a high-resolution photon-counting detector computed tomography (PCD-CT) system with a 1024×1024 matrix reconstruction can improve the visualization of fine structures in the lungs compared with conventional high-resolution CT (HRCT). Materials and Methods Twenty-two adult patients referred for clinical chest HRCT (mean CTDI vol, 13.58 mGy) underwent additional dose-matched PCD-CT (mean volume CT dose index, 13.37 mGy) after written informed consent. Computed tomography images were reconstructed at a slice thickness of 1.5 mm and an image increment of 1 mm with our routine HRCT reconstruction kernels (B46 and Bv49) at 512 and 1024 matrix sizes for conventional energy-integrating detector (EID) CT scans. For PCD-CT, routine B46 kernel and an additional sharp kernel (Q65, unavailable for EID) images were reconstructed at 1024 matrix size. Two thoracic radiologists compared images from EID and PCD-CT noting the highest level bronchus clearly identified in each lobe of the right lung, and rating bronchial wall conspicuity of third- and fourth-order bronchi. Lung nodules were also compared with the B46/EID/512 images using a 5-point Likert scale. Statistical analysis was performed using a Wilcoxon signed rank test with a P < 0.05 considered significant. Results Compared with B46/EID/512, readers detected higher-order bronchi using B46/PCD/1024 and Q65/PCD/1024 images for every lung lobe (P < 0.0015), but in only the right middle lobe for B46/EID/1024 (P = 0.007). Readers were able to better identify bronchial walls of the third- and fourth-order bronchi better using the Q65/PCD/1024 images (mean Likert scores of 1.1 and 1.5), which was significantly higher compared with B46/EID/1024 or B46/PCD/1024 images (mean difference, 0.8; P < 0.0001). The Q65/PCD/1024 images had a mean nodule score of 1 ± 1.3 for reader 1, and −0.1 (0.9) for reader 2, with one reader having improved nodule evaluation scores for both PCD kernels (P < 0.001), and the other reader not identifying any increased advantage over B46/EID/1024 (P = 1.0). Conclusions High-resolution lung PCD-CT with 1024 image matrix reconstruction increased radiologists' ability to visualize higher-order bronchi and bronchial walls without compromising nodule evaluation compared with current chest CT, creating an opportunity for radiologists to better evaluate airway pathology.
Detection and Characterization of Renal Stones by Using Photon-Counting–based CT
Marcus, Roy , Fletcher, Joel G. , Ferrero, Andrea , Leng, Shuai , Halaweish, Ahmed F., Gutjahr, Ralf , Vrtiska, Terri J., Wells, Mike L., McCollough, Cynthia H. , Marcus, Roy P, Enders, Felicity T, McCollough, Cynthia H , Fletcher, Joel G , Leng, Shuai , Enders, Felicity

Radiology | August 7, 2018 | Volume: 289 | Issue: 2 | Pages: 436-442

10.1148/radiol.2018180126 | PMID 30084728 Get It

Radiation Dose in CT–guided Interventional Procedures: Establishing a Benchmark
Leng, Shuai , Leng, Shuai

Radiology | July 17, 2018 | Volume: 289 | Issue: 1 | Pages: 158-159

10.1148/radiol.2018181245 | PMID 30015581 Get It

Shen-Shuai-Ning granule decreased serum concentrations of indoxyl sulphate in uremic patients undergoing peritoneal dialysis
Chen, Xujiao , Gao, Shouhong , Ruan, Mengna, Chen, Sixiu , Xu, Jing , Xing, Xiaohong , Pan, Xiaohong , Mei, Changlin , Mao, Zhiguo , Pan, Xiaohong

Bioscience Reports | June 19, 2018 | Volume: 38 | Issue: 5 | Pages: No page available

10.1042/bsr20171694 | PMID 29921575 Get It

Clearance of protein-bound uremic toxins (PBUTs) by dialysis is a challenge in the treatment of uremic patients. Shen-Shuai-Ning (SSN), a traditional Chinese medicine formulation, has been used commonly in China to retard kidney disease progression and decrease uremic toxins in chronic kidney disease (CKD) patients, but the effects of SSN on serum PBUTs in dialysis patients were not investigated. We conducted a randomized controlled trial in patients on peritoneal dialysis (PD) at dialysis center of Changzheng Hospital to evaluate the effects of SSN on serum PBUTs. Participants with SSN intervention took 5 g SSN granule three times daily for 12 weeks, while the baseline medications and dialysis prescriptions remained during the study in all patients. The serum concentrations of indoxyl sulphate (IS) and p-cresol sulphate (PCS) were determined by HPLC/MS/MS and biochemical parameters were assessed during the study. Sixty PD patients were enrolled and randomly allocated into SSN group and control group. Total IS level was significantly lower in SSN group than in control group at week 4, 8, and 12 (27.28 ± 18.19, 29.73 ± 19.10, and 29.41 ± 17.61 mg/l compared with 39.25 ± 20.23, 44.86 ± 23.91, and 45.34 ± 33.52 mg/l, respectively). However, there were no statistical difference of total PCS, free forms of IS and PCS concentrations between SSN group and control group during 12 weeks follow-up. Administration of SSN granule orally decreased serum total IS level effectively in uremic patients on PD with good tolerance. Benefits of PD patients’ outcomes from IS reduction by SSN awaits further large size and long duration clinical trials to verify.
150-μm Spatial Resolution Using Photon-Counting Detector Computed Tomography Technology
Rajendran, Kishore , Gong, Hao , Zhou, Wei , Halaweish, Ahmed F., Henning, André , Kappler, S. , Baer, Matthias , Rajendran, Kishore , Zhou, Wei , Leng, Shuai , Fletcher, Joel G. , McCollough, Cynthia H.

Investigative Radiology | May 31, 2018 | Volume: 53 | Issue: 11 | Pages: 655-662

10.1097/rli.0000000000000488 | PMID 29847412 Get It

Objective The aims of this study were to quantitatively assess two new scan modes on a photon-counting detector computed tomography system, each designed to maximize spatial resolution, and to qualitatively demonstrate potential clinical impact using patient data. Materials and Methods This Health Insurance Portability Act–compliant study was approved by our institutional review board. Two high–spatial-resolution scan modes (Sharp and UHR) were evaluated using phantoms to quantify spatial resolution and image noise, and results were compared with the standard mode (Macro). Patients were scanned using a conventional energy-integrating detector scanner and the photon-counting detector scanner using the same radiation dose. In first patient images, anatomic details were qualitatively evaluated to demonstrate potential clinical impact. Results Sharp and UHR modes had a 69% and 87% improvement in in-plane spatial resolution, respectively, compared with Macro mode (10% modulation-translation-function values of 16.05, 17.69, and 9.48 lp/cm, respectively). The cutoff spatial frequency of the UHR mode (32.4 lp/cm) corresponded to a limiting spatial resolution of 150 μm. The full-width-at-half-maximum values of the section sensitivity profiles were 0.41, 0.44, and 0.67 mm for the thinnest image thickness for each mode (0.25, 0.25, and 0.5 mm, respectively). At the same in-plane spatial resolution, Sharp and UHR images had up to 15% lower noise than Macro images. Patient images acquired in Sharp mode demonstrated better delineation of fine anatomic structures compared with Macro mode images. Conclusions Phantom studies demonstrated superior resolution and noise properties for the Sharp and UHR modes relative to the standard Macro mode and patient images demonstrated the potential benefit of these scan modes for clinical practice.
Evaluation of projection‐ and dual‐energy‐based methods for metal artifact reduction in CT using a phantom study
Long, Zaiyang , Bruesewitz, Michael R. , Amrami, Kimberly K. , Adkins, Mark C., Glazebrook, Katrina N. , Kofler, James M., Halaweish, Ahmed F., Yu, Lifeng , DeLone, David R. , Morris, Jonathan M. , Leng, Shuai , McCollough, Cynthia H. , Fletcher, Joel G. , Yu, Lifeng

Journal of Applied Clinical Medical Physics | May 11, 2018 | Volume: 19 | Issue: 4 | Pages: 252-260

10.1002/acm2.12347 | PMID 29749048 Get It

AbstractObjectivesBoth projection and dual‐energy (DE)‐based methods have been used for metal artifact reduction (MAR) in CT. The two methods can also be combined. The purpose of this work was to evaluate these three MAR methods using phantom experiments for five types of metal implants.Materials and MethodsFive phantoms representing spine, dental, hip, shoulder, and knee were constructed with metal implants. These phantoms were scanned using both single‐energy (SE) and DE protocols with matched radiation output. The SE data were processed using a projection‐based MAR (iMAR, Siemens) algorithm, while the DE data were processed to generate virtual monochromatic images at high keV (Mono+, Siemens). In addition, the DE images after iMAR were used to generate Mono+ images (DE iMAR Mono+). Artifacts were quantitatively evaluated using CT numbers at different regions of interest. Iodine contrast‐to‐noise ratio (CNR) was evaluated in the spine phantom. Three musculoskeletal radiologists and two neuro‐radiologists independently ranked the artifact reduction.ResultsThe DE Mono+ at high keV resulted in reduced artifacts but also lower iodine CNR. The iMAR method alone caused missing tissue artifacts in dental phantom. DE iMAR Mono+ caused wrong CT numbers in close proximity to the metal prostheses in knee and hip phantoms. All musculoskeletal radiologists ranked SE iMAR > DE iMAR Mono+ > DE Mono+ for knee and hip, while DE iMAR Mono+ > SE iMAR > DE Mono+ for shoulder. Both neuro‐radiologists ranked DE iMAR Mono+ > DE Mono+ > SE iMAR for spine and DE Mono+ > DE iMAR Mono+ > SE iMAR for dental.ConclusionsThe SE iMAR was the best choice for the hip and knee prostheses, while DE Mono+ at high keV was best for dental implants and DE iMAR Mono+ was best for spine and shoulder prostheses. Artifacts were also introduced by MAR algorithms.
Pitch imperfect
Li, Shuai

Science | May 10, 2018 | Volume: 360 | Issue: 6389 | Pages: 678-678

10.1126/science.360.6389.678 | PMID 29748287 Get It