Back to Authors

Cockerill, Franklin R.

Mayo Clinic

Mayo Clinic

Citations 58

Comparison of agar dilution, broth dilution, and disk diffusion testing of ampicillin against Haemophilus species by using in-house and commercially prepared media
Kohner, Peggy C., Rosenblatt, Jon E., Cockerill, Franklin R.

Journal of Clinical Microbiology | January 6, 2020 | Volume: 32 | Issue: 6 | Pages: 1594-1596

10.1128/jcm.32.6.1594-1596.1994 Get It

An evaluation to determine the optimal method for the in vitro susceptibility testing of Haemophilus strains to ampicillin was undertaken. In our hands, in-house-prepared Haemophilus Test Medium used by either the broth macrodilution or agar dilution method produced the most consistent results, especially for beta-lactamase-negative, ampicillin-resistant H. influenzae strains.
Evaluation of two rapid antigen assays, BioStar Strep A OIA and Pacific Biotech CARDS O.S., and culture for detection of group A streptococci in throat swabs
Dale, J C, Vetter, Emily A., Contezac, Joan M., Iverson, L. K., Wollan, Peter C. , Cockerill, Franklin R.

Journal of Clinical Microbiology | January 6, 2020 | Volume: 32 | Issue: 11 | Pages: 2698-2701

10.1128/jcm.32.11.2698-2701.1994 Get It

Two rapid methods, BioStar Strep A OIA (OIA; BioStar, Inc., Boulder, Colo.), an optical immunoassay, and CARDS O.S. (O.S.; Pacific Biotech, Inc., San Diego, Calif.), a color immunochromographic assay, and two culture methods, one with 5% sheep blood agar (SBA) and one with Todd-Hewitt broth (TH; Remel, Lenexa, Kans.), were evaluated for use in the detection of Streptococcus pyogenes from pharnygeal swabs. Seven hundred forty-six double swabs (Culturette II) were processed, with OIA and SBA culture performed on one swab and O.S. and SBA culture performed on the other swab. The pledget from the Culturette II was incubated overnight in TH and was subcultured onto SBA for an additional 48 h in ambient air. All beta-hemolytic streptococci from culture were tested by a direct fluorescent-antibody test (Difco Laboratories, Detroit, Mich.). Specimens with discordant fluorescent-antibody test and rapid test results were also tested by using the Streptex latex agglutination reagent (Murex Diagnostics Limited, Dartford, England). The results obtained by all testing methods were compared with a combined test result ("gold standard"), which was defined as any positive culture detected by the SBA or TH culture methods and confirmed by Streptex latex agglutination or, in the case of negative results by both culture methods, a concomitant positive result by OIA and O.S. antigen testing. Sensitivity and specificity results for each of the methods were as follows, respectively: OIA, 81.0 and 97.5%; O.S., 74.4 and 99.0%; SBA culture, 92.3 and 98.3%; and TH culture, 86.4 and 100%. Both OIA and O.S. are suitable screening methods for detecting S. pyogenes directly from throat swabs but are of insufficient sensitivity to eliminate the need for backup cultures for specimens with negative OIA and O.S. results.
Comparison of Gen-Probe Group A streptococcus Direct Test with culture for diagnosing streptococcal pharyngitis
Pokorski, S J, Vetter, Emily A., Wollan, Peter C. , Cockerill, Franklin R.

Journal of Clinical Microbiology | January 6, 2020 | Volume: 32 | Issue: 6 | Pages: 1440-1443

10.1128/jcm.32.6.1440-1443.1994 Get It

The Group A Streptococcus Direct Test (GP-ST test; Gen-Probe, Inc., San Diego, Calif.) was compared with culture for the detection of Streptococcus pyogenes from throat swabs of 767 patients with pharyngitis. Swabs were tested by the GP-ST test after inoculating a 5% sheep blood agar (SBA) plate. SBA plates were incubated at 35 degrees C in room air for 72 h. SBA plates with no evidence of beta-hemolytic colonies after 18 to 24 h of incubation were subcultured by taking a swipe across the primary inoculum from the SBA plate to an agar selective for Streptococcus spp. In a low-prevalence (11.9%) population and in comparison with the number of positive cultures detected by the 72-h single-culture method (SBA plate method), the GP-ST test had a sensitivity of 88.6%, a specificity of 97.8%, a positive predictive value of 83.9%, and a negative predictive value of 98.5%. In comparison with the growth of any colonies of S. pyogenes on the 72-h SBA plates plus a subculture onto selective blood agar, the sensitivities and specificities were as follows: 72-h SBA plate method, 96.7 and 100%, respectively; GP-ST test, 85.7 and 97.8%, respectively. The GP-ST test is an easy-to-perform, reliable test for batch screening of throat swabs for S. pyogenes.
Comparison of Protein A Gene Sequencing with Pulsed-Field Gel Electrophoresis and Epidemiologic Data for Molecular Typing of Methicillin-Resistant Staphylococcus aureus
Waddington, Michael, Smith, Douglas H. , Manahan, Janice M., Kohner, Peggy C., Highsmith, Leanne M., Li, Haijing , Cockerill, Franklin R., Thompson, Rodney L., Montgomery, Stacy O., Persing, David H., Tang, Yi‐Wei

Journal of Clinical Microbiology | December 31, 2019 | Volume: 38 | Issue: 4 | Pages: 1347-1351

10.1128/jcm.38.4.1347-1351.2000 Get It

ABSTRACT The epidemiologic relatedness of methicillin-resistant Staphylococcus aureus (MRSA) isolates is currently determined by analysis of chromosomal DNA restriction patterns by pulsed-field gel electrophoresis (PFGE). We have evaluated an alternative typing system (MicroSeq StaphTrack Kit; Perkin-Elmer Biosystems) based on the sequence analysis of the chromosomally encoded polymorphic repeat X region of the S. aureus protein A ( spa ) gene. A total of 69 clinical MRSA isolates were divided into 18 groups according to the number and nucleotide sequences of the spa repeats. Molecular typing results obtained both by spa sequencing and from the PFGE patterns were concordant except for one group, which contained 20 isolates recovered over a 2-year period from hospitalized patients at the Mayo Clinic. Although the spa typing patterns were indistinguishable for those isolates, PFGE analysis yielded seven related but distinguishable patterns. Further coagulase gene sequence analysis subtyped those 20 strains into four groups which followed distinct temporal and geographic distributions. During a 2-year epidemic period there were up to 7 fragment changes in PFGE patterns among epidemiologically related isolates, suggesting that PFGE may be unsuitable for long-term typing of strains involved in epidemics. Although more limited than PFGE in discriminatory power, spa sequencing analysis could be used as a screening method for typing of MRSA strains because of the shorter turnaround time, ease of use, and the inherent advantages of sequence analysis, storage, and sharing of information.
Frequency of Isolation of Staphylococcus lugdunensis among Staphylococcal Isolates Causing Endocarditis: a 20-Year Experience
Patel, Robin , Piper, Kerryl E., Rouse, Mark S., Uhl, James R., Cockerill, Franklin R., Steckelberg, James M., Patel, Robin

Journal of Clinical Microbiology | December 31, 2019 | Volume: 38 | Issue: 11 | Pages: 4262-4263

10.1128/jcm.38.11.4262-4263.2000 Get It

ABSTRACT Eighty-nine staphylococcal isolates recovered from patients with bacterial endocarditis at the Mayo Clinic from 1980 to 1999 were studied to determine the prevalence of Staphylococcus lugdunensis among clinical isolates of staphylococci causing endocarditis. Four isolates, all from patients with native mitral valve endocarditis, were identified as S. lugdunensis .
Evaluation of the Alexon-Trend ProSpecT Campylobacter Microplate Assay
Tolcin, Rita, LaSalvia, Margaret M., Kirkley, B A, Vetter, Emily A., Cockerill, Franklin R., Procop, Gary W.

Journal of Clinical Microbiology | December 31, 2019 | Volume: 38 | Issue: 10 | Pages: 3853-3855

10.1128/jcm.38.10.3853-3855.2000 Get It

ABSTRACT We evaluated stool specimens known to contain or be free of Campylobacter by traditional culture, using the ProSpecT Campylobacter microplate assay (Alexon-Trend, Ramsey, Minn.). This rapid enzyme immunoassay for the detection of Campylobacter -specific antigens demonstrated 96% sensitivity and 99% specificity and is an acceptable alternative method of Campylobacter detection.
Performance of Five Agar Media for Recovery of Fungi from Isolator Blood Cultures
Procop, Gary W. , Cockerill, Franklin R., Vetter, Emily A., Harmsen, William S. , Roberts, Glenn D., Hughes, J. G.

Journal of Clinical Microbiology | December 31, 2019 | Volume: 38 | Issue: 10 | Pages: 3827-3829

10.1128/jcm.38.10.3827-3829.2000 Get It

ABSTRACT We studied the recovery of 1,270 fungal isolates from 176,144 Isolator blood cultures (0.72% positive) on bacterial and fungal media, under routine and differing incubation conditions. Except with Histoplasma capsulatum , chocolate agar incubated for only 3 days proved to be an excellent medium for the recovery of fungi from the Isolator system.
Comparison of Susceptibility Testing Methods with mecA Gene Analysis for Determining Oxacillin (Methicillin) Resistance in Clinical Isolates of Staphylococcus aureus and Coagulase-Negative
Kohner, Peggy C., Uhl, J. R., Kolbert, Christopher P., Persing, David H., Cockerill, Franklin R.

Journal of Clinical Microbiology | December 31, 2019 | Volume: 37 | Issue: 9 | Pages: 2952-2961

10.1128/jcm.37.9.2952-2961.1999 Get It

ABSTRACT Ninety-nine clinical staphylococcal isolates (58 coagulase-negative Staphylococcus spp. [CoNS] and 41 Staphylococcus aureus isolates) were evaluated for susceptibility to oxacillin. The following susceptibility testing methods, media, and incubation conditions were studied: agar dilution by using Mueller-Hinton (MH) medium (Difco) supplemented with either 0, 2, or 4% NaCl and incubation at 30 or 35°C in ambient air for 24 or 48 h; disk diffusion by using commercially prepared MH medium (Difco) and MH II agar (BBL) and incubation at 35°C in ambient air for 24 or 48 h; and agar screen (spot or swab inoculation) by using commercially prepared agar (Remel) or MH agar (Difco) prepared in-house, each containing 4% NaCl and 6 μg of oxacillin/ml (0.6-μg/ml oxacillin was also studied with MH agar prepared in-house for the agar swab method and CoNS isolates) and incubation at 35°C in ambient air for 24 or 48 h for swab inoculation and at 30 or 35°C in ambient air for 24 or 48 h for spot inoculation. The results for these methods were compared to the results for mecA gene detection by a PCR method. Given the ability to support growth and the results for susceptibility testing (the breakpoint for susceptible isolates was ≤2 μg/ml), the best methods for CoNS isolates were (i) agar dilution by using MH medium supplemented with 4% NaCl and incubation at 35°C for 48 h (no growth failures were noted, and sensitivity was 97.6%) and (ii) agar screen (swab inoculation) by using MH medium prepared in-house supplemented with 4% NaCl and containing 0.6 μg oxacillin/ml and incubation at 35°C for 48 h (one isolate that did not carry the mecA gene did not grow, and the sensitivity was 100%). All but one (agar dilution without added NaCl and incubation at 30°C for 48 h) of the methods tested revealed all oxacillin-resistant S. aureus isolates, and no growth failures occurred with any method. If the breakpoint for susceptibility was lowered to ≤1 μg/ml for agar dilution methods, more CoNS isolates with oxacillin resistance related to the mecA gene were detected when 0 or 2% NaCl agar supplementation was used. Only one CoNS isolate with mecA gene-associated resistance was not detected by using agar dilution and MH medium supplemented with 4% NaCl with incubation for 48 h. When the breakpoint for susceptibility was decreased 10-fold (from 6.0 to 0.6 μg of oxacillin per ml) for the agar swab screen method, fully 100% of the CoNS isolates that carried the mecA gene were identified.
Direct mecA Detection from Blood Culture Bottles by Branched-DNA Signal Amplification
Zheng, Xiaotian , Kolbert, C. P., Varga-Delmore, P., Arruda, José Germano Ferraz de , Lewis, Margaret Reed , Kolberg, Janice A., Cockerill, Franklin R., Persing, D. H., Arruda, J., Lewis, M.

Journal of Clinical Microbiology | December 31, 2019 | Volume: 37 | Issue: 12 | Pages: 4192-4193

10.1128/jcm.37.12.4192-4193.1999 Get It

ABSTRACT A branched-DNA (bDNA) signal amplification method was used to detect the mecA gene directly from blood culture broth growing staphylococci. BACTEC blood culture bottles with positive growth indices and containing staphylococcus-like organisms as shown by Gram stain were tested for the presence of the mecA gene. Comparison of test results was done among 225 patients (one blood culture from each patient). Compared with PCR, the sensitivity and specificity of the bDNA method are 100 and 99%, respectively. The bDNA test is carried out in a 96-well format and requires approximately 6 h to perform. Our preliminary results suggest that direct detection of the mecA gene by bDNA signal amplification is (i) sensitive enough to detect mecA directly from blood culture bottles without the requirement for subculture and (ii) as sensitive and specific as the PCR-based method.
Clinical Comparison of the Treponema pallidum CAPTIA Syphilis-G Enzyme Immunoassay with the Fluorescent Treponemal Antibody Absorption Immunoglobulin G Assay for Syphilis Testing
Halling, Valerie W., Jones, Mary F. , Bestrom, Jean E., Wold, Arlo D., Rosenblatt, Jon E., Smith, Thomas F., Cockerill, F. R., Cockerill, Franklin R.

Journal of Clinical Microbiology | December 31, 2019 | Volume: 37 | Issue: 10 | Pages: 3233-3234

10.1128/jcm.37.10.3233-3234.1999 Get It

ABSTRACT Recently, a treponema-specific immunoglobulin G (IgG) enzyme immunoassay (EIA), the CAPTIA Syphilis-G (Trinity Biotech, Jamestown, N.Y.), has become available as a diagnostic test for syphilis. A total of 89 stored sera previously tested by the fluorescent treponemal antibody absorption (FTA-ABS) IgG assay were evaluated by the CAPTIA EIA. The FTA-ABS IgG procedure was performed by technologists unblinded to results of rapid plasmid reagin (RPR) testing of the same specimens. Borderline CAPTIA-positive samples (antibody indices of ≥0.650 and ≤0.900) were retested; if the second analysis produced an index of >0.900, the sample was considered positive. Thirteen of 89 (15%) samples had discrepant results. Compared to the FTA-ABS assay, the CAPTIA EIA had a sensitivity and specificity and positive and negative predictive values of 70.7, 97.9, 96.7, and 79.7%, respectively. In another analysis, discrepancies between results were resolved by repeated FTA-ABS testing (technologists were blinded to previous RPR results) and patient chart reviews. Seven CAPTIA-negative samples which were previously interpreted (unblinded) as minimally reactive by the FTA method were subsequently interpreted (blinded) as nonreactive. One other discrepant sample (CAPTIA negative and FTA-ABS positive [at an intensity of 3+], unblinded) was FTA negative with repeated testing (blinded). For the five remaining discrepant samples, chart reviews indicated that one patient (CAPTIA negative and FTA-ABS positive [minimally reactive], blinded) had possible syphilis. These five samples were also evaluated and found to be negative by another treponema-specific test, the Treponema pallidum microhemagglutination assay. Therefore, after repeated testing and chart reviews, 2 of the 89 (2%) samples had discrepant results; the adjusted sensitivity, specificity, and positive and negative predictive values were 96.7, 98.3, 96.7, and 98.3%, respectively. This study demonstrates that the CAPTIA IgG EIA is a reliable method for syphilis testing and that personnel performing tests which require subjective interpretation, like the FTA-ABS test, may be biased by RPR test results.