Back to Authors

Jones, Mary F.

https://orcid.org/0009-0000-7419-1661

Mayo Clinic

Mayo Clinic

Citations 6

Comparison of shell vials and conventional tubes seeded with rhabdomyosarcoma and MRC-5 cells for the rapid detection of herpes simplex virus
Espy, Mark J., Wold, Arlo D., Jespersen, Deborah J., Jones, Mary F. , Smith, Thomas F.

Journal of Clinical Microbiology | January 5, 2020 | Volume: 29 | Issue: 12 | Pages: 2701-2703

10.1128/jcm.29.12.2701-2703.1991 Get It

Shell vials (SV) and conventional tubes (CT) were seeded with rhabdomyosarcoma (RD) and MRC-5 cells and inoculated with clinical specimens, and the systems were evaluated for the rapid diagnosis of herpes simplex virus (HSV) infections by detection of cytopathic effects (CPE) (for CT, for 7 days) and by using fluoresceinated monoclonal antibodies (for SV, 16 h postinoculation). Of 245 genital specimens (16 from males and 229 from females) 56 (23%) seeded with MRC-5 cells (14 type 1 and 42 type 2) and 55 (22%) seeded with RD cells were detected in CT; however, CPE were recognized in only 26 (46%) of the total HSV-positive cultures 1 day postinoculation. Forty-eight (86% sensitivity, MRC-5) and 46 (84% sensitivity, RD) HSV strains were detected immunologically in SV 16 h postinoculation. Early CPE in CT or fluorescent foci in SV were easier to detect in MRC-5 than in RD cell cultures. MRC-5 and RD cells were equally sensitive to infection with HSV. CT cell cultures were more sensitive than SV but less rapid for the detection of HSV infection (P less than 0.01). We recommend using SV for the rapid diagnosis of HSV infections, but in addition, CT must be inoculated with MRC-5 or RD to ensure maximum detection of this virus.
Clinical Comparison of the Treponema pallidum CAPTIA Syphilis-G Enzyme Immunoassay with the Fluorescent Treponemal Antibody Absorption Immunoglobulin G Assay for Syphilis Testing
Halling, Valerie W., Jones, Mary F. , Bestrom, Jean E., Wold, Arlo D., Rosenblatt, Jon E., Smith, Thomas F., Cockerill, F. R., Cockerill, Franklin R.

Journal of Clinical Microbiology | December 31, 2019 | Volume: 37 | Issue: 10 | Pages: 3233-3234

10.1128/jcm.37.10.3233-3234.1999 Get It

ABSTRACT Recently, a treponema-specific immunoglobulin G (IgG) enzyme immunoassay (EIA), the CAPTIA Syphilis-G (Trinity Biotech, Jamestown, N.Y.), has become available as a diagnostic test for syphilis. A total of 89 stored sera previously tested by the fluorescent treponemal antibody absorption (FTA-ABS) IgG assay were evaluated by the CAPTIA EIA. The FTA-ABS IgG procedure was performed by technologists unblinded to results of rapid plasmid reagin (RPR) testing of the same specimens. Borderline CAPTIA-positive samples (antibody indices of ≥0.650 and ≤0.900) were retested; if the second analysis produced an index of >0.900, the sample was considered positive. Thirteen of 89 (15%) samples had discrepant results. Compared to the FTA-ABS assay, the CAPTIA EIA had a sensitivity and specificity and positive and negative predictive values of 70.7, 97.9, 96.7, and 79.7%, respectively. In another analysis, discrepancies between results were resolved by repeated FTA-ABS testing (technologists were blinded to previous RPR results) and patient chart reviews. Seven CAPTIA-negative samples which were previously interpreted (unblinded) as minimally reactive by the FTA method were subsequently interpreted (blinded) as nonreactive. One other discrepant sample (CAPTIA negative and FTA-ABS positive [at an intensity of 3+], unblinded) was FTA negative with repeated testing (blinded). For the five remaining discrepant samples, chart reviews indicated that one patient (CAPTIA negative and FTA-ABS positive [minimally reactive], blinded) had possible syphilis. These five samples were also evaluated and found to be negative by another treponema-specific test, the Treponema pallidum microhemagglutination assay. Therefore, after repeated testing and chart reviews, 2 of the 89 (2%) samples had discrepant results; the adjusted sensitivity, specificity, and positive and negative predictive values were 96.7, 98.3, 96.7, and 98.3%, respectively. This study demonstrates that the CAPTIA IgG EIA is a reliable method for syphilis testing and that personnel performing tests which require subjective interpretation, like the FTA-ABS test, may be biased by RPR test results.
Inhibition Controls for Qualitative Real-Time PCR Assays: Are They Necessary for All Specimen Matrices?
Buckwalter, Seanne P., Sloan, Lynne M., Cunningham, Scott A. , Espy, Mark J., Uhl, J. R., Jones, Mary F. , Vetter, Emily A., Mandrekar, Jayawant N. , Cockerill, Franklin R., Pritt, Bobbi S. , Patel, Robin , Wengenack, Nancy L. , Patel, Robin , Pritt, Bobbi S , Cunningham, Scott A

Journal of Clinical Microbiology | April 16, 2014 | Volume: 52 | Issue: 6 | Pages: 2139-2143

10.1128/jcm.03389-13 Get It

ABSTRACT A retrospective analysis of 386,706 specimens representing a variety of matrix types used in qualitative real-time PCR assays determined the overall inhibition rate to be 0.87% when the inhibition control was added preextraction to 5,613 specimens and 0.01% when the inhibition control was added postextraction but preamplification in 381,093 specimens. Inhibition rates of ≤1% were found for all specimen matrix types except urine and formalin-fixed, paraffin-embedded tissue.
Real-Time PCR in Clinical Microbiology: Applications for Routine Laboratory Testing
Espy, Mark J., Uhl, J. R., Sloan, Lynne M., Buckwalter, Seanne P., Jones, Mary F. , Vetter, Emily A., Yao, Joseph D. , Wengenack, Nancy L. , Rosenblatt, Jon E., Cockerill, F. R., Smith, T. F., Cockerill, Franklin R.

Clinical Microbiology Reviews | July 17, 2006 | Volume: 19 | Issue: 3 | Pages: 595-595

10.1128/cmr.00022-06 Get It

Real-Time PCR in Clinical Microbiology: Applications for Routine Laboratory Testing
Espy, Mark J., Uhl, J. R., Sloan, Lynne M., Buckwalter, Seanne P., Jones, Mary F. , Vetter, Emily A., Yao, Joseph D. , Wengenack, Nancy L. , Rosenblatt, Jon E., Cockerill, Franklin R., Smith, Thomas F.

Clinical Microbiology Reviews | January 17, 2006 | Volume: 19 | Issue: 1 | Pages: 165-256

10.1128/cmr.19.1.165-256.2006 Get It

SUMMARY Real-time PCR has revolutionized the way clinical microbiology laboratories diagnose many human microbial infections. This testing method combines PCR chemistry with fluorescent probe detection of amplified product in the same reaction vessel. In general, both PCR and amplified product detection are completed in an hour or less, which is considerably faster than conventional PCR detection methods. Real-time PCR assays provide sensitivity and specificity equivalent to that of conventional PCR combined with Southern blot analysis, and since amplification and detection steps are performed in the same closed vessel, the risk of releasing amplified nucleic acids into the environment is negligible. The combination of excellent sensitivity and specificity, low contamination risk, and speed has made real-time PCR technology an appealing alternative to culture- or immunoassay-based testing methods for diagnosing many infectious diseases. This review focuses on the application of real-time PCR in the clinical microbiology laboratory.
Prospective Comparison of Cell Cultures and Nucleic Acid Amplification Tests for Laboratory Diagnosis of Chlamydia trachomatis Infections
Jespersen, Deborah J., Flatten, Karen S., Jones, Mary F. , Smith, Thomas F.

Journal of Clinical Microbiology | October 5, 2005 | Volume: 43 | Issue: 10 | Pages: 5324-5326

10.1128/jcm.43.10.5324-5326.2005 Get It

ABSTRACT Specimens submitted in M5 medium for cell culture detection of Chlamydia trachomatis were tested by nucleic acid amplification testing (NAAT) and in cell cultures. Of 35 (genital) and 26 (nongenital) specimens positive for C. trachomatis , 21 and 14 specimens, respectively, were detected exclusively by NAAT. NAAT is significantly ( P < 0.0001) more sensitive than cell culture and should be considered the new “gold standard” for the laboratory diagnosis of C. trachomatis infections.