Back to Authors

Wold, Arlo D.

Mayo Clinic

Mayo Clinic

Citations 9

Comparison of shell vials and conventional tubes seeded with rhabdomyosarcoma and MRC-5 cells for the rapid detection of herpes simplex virus
Espy, Mark J., Wold, Arlo D., Jespersen, Deborah J., Jones, Mary F. , Smith, Thomas F.

Journal of Clinical Microbiology | January 5, 2020 | Volume: 29 | Issue: 12 | Pages: 2701-2703

10.1128/jcm.29.12.2701-2703.1991 Get It

Shell vials (SV) and conventional tubes (CT) were seeded with rhabdomyosarcoma (RD) and MRC-5 cells and inoculated with clinical specimens, and the systems were evaluated for the rapid diagnosis of herpes simplex virus (HSV) infections by detection of cytopathic effects (CPE) (for CT, for 7 days) and by using fluoresceinated monoclonal antibodies (for SV, 16 h postinoculation). Of 245 genital specimens (16 from males and 229 from females) 56 (23%) seeded with MRC-5 cells (14 type 1 and 42 type 2) and 55 (22%) seeded with RD cells were detected in CT; however, CPE were recognized in only 26 (46%) of the total HSV-positive cultures 1 day postinoculation. Forty-eight (86% sensitivity, MRC-5) and 46 (84% sensitivity, RD) HSV strains were detected immunologically in SV 16 h postinoculation. Early CPE in CT or fluorescent foci in SV were easier to detect in MRC-5 than in RD cell cultures. MRC-5 and RD cells were equally sensitive to infection with HSV. CT cell cultures were more sensitive than SV but less rapid for the detection of HSV infection (P less than 0.01). We recommend using SV for the rapid diagnosis of HSV infections, but in addition, CT must be inoculated with MRC-5 or RD to ensure maximum detection of this virus.
Detection of cytomegalovirus from blood leukocytes separated by sepracell-MN and Ficoll-Paque/Macrodex methods
Paya, C. V., Wold, Arlo D., Smith, Thomas F.

Journal of Clinical Microbiology | January 5, 2020 | Volume: 26 | Issue: 10 | Pages: 2031-2033

10.1128/jcm.26.10.2031-2033.1988 Get It

Two density gradient separation techniques for separation of blood leukocytes were compared for the laboratory diagnosis of cytomegalovirus (CMV) viremia. Of 510 blood specimens processed by both methods, 76 (14.9%) yielded CMV. Of the 76 positive specimens, 66 (87%) and 65 (86%) were processed by the Ficoll-Paque/Macrodex (F-P/M; Macrodex is dextran 70 in normal saline; Pharmacia, Pisataway, N.J.) and Sepracell-MN methods, respectively. Of the 76 CMV-positive blood specimens, 72 (95%) were detected in shell vial cell cultures, whereas only 42 (55%) were detected in conventional tube cell cultures. The time for recognition of specific cytopathic effects due to CMV in tube cell cultures (8.0 versus 7.1 days), the number of fluorescent foci in each positive shell vial culture (19.3 versus 20.1), and the costs of the reagents ($3.50 versus $2.80) were similar and independent of the leukocyte separation method (F-P/M versus Sepracell-MN). Recovery of CMV from heparinized blood (F-P/M method) was similar to that from EDTA-anticoagulated blood (Sepracell-MN method). The Sepracell-MN method is a rapid and sensitive method for detection of CMV from blood specimens and is recommended as a replacement for the more tedious and time-consuming F-P/M procedure.
Effect of treatment of shell vial cell cultures with dimethyl sulfoxide and dexamethasone for detection of cytomegalovirus
Espy, Mark J., Wold, Arlo D., Ilstrup, D M, Smith, Thomas F.

Journal of Clinical Microbiology | January 5, 2020 | Volume: 26 | Issue: 6 | Pages: 1091-1093

10.1128/jcm.26.6.1091-1093.1988 Get It

Urine specimens submitted for the diagnosis of cytomegalovirus infection were inoculated into shell vials that had been pretreated with a combination of dimethyl sulfoxide (DMSO) and dexamethasone (DEX). The results were compared with those for inoculated shell vials which had received no drug treatment. Of 664 specimens, 100 (15%) were positive for cytomegalovirus. Of the 100 strains of cytomegalovirus, 88 (88%) were detected in both DMSO-DEX-treated and untreated shell vials. Of the remaining 12 positive specimens, 6 were detected with untreated shell vials exclusively and 6 were detected with DMSO-DEX-treated shell vials alone (not significant by the sign test). The median number of fluorescent foci was not significantly higher in DMSO-DEX-treated shell vials compared with that in untreated cultures (Wilcoxon signed-rank test; P = 0.1). DMSO-DEX-treated monolayers did not enhance the sensitivity detection of cytomegalovirus in shell vial cell cultures.
Evaluation of number of shell vial cell cultures per clinical specimen for rapid diagnosis of cytomegalovirus infection
Paya, C. V., Wold, Arlo D., Ilstrup, D M, Smith, Thomas F.

Journal of Clinical Microbiology | January 5, 2020 | Volume: 26 | Issue: 2 | Pages: 198-200

10.1128/jcm.26.2.198-200.1988 Get It

Specimens submitted for the diagnosis of cytomegalovirus (CMV) infection were inoculated into three (blood) or two (urine, tissue, bronchoalveolar lavage [BAL]) shell vials seeded with MRC-5 cells for the diagnosis of CMV infection. We evaluated the detection of 993 specimens that were positive for CMV according to the number of shell vial cell cultures inoculated per specimen. For blood cultures, and considering one CMV-positive shell vial as 100%, inoculation of three shell vials versus one increased the detection rate of the virus by 51%. Inoculation of three shell vials compared with two yielded a 20% increase in the detection rate of CMV. For urine, tissue, and BAL specimens, inoculation of two shell vials compared with one resulted in increases of 7, 10, and 5%, respectively. For maximum detection of CMV in shell vial cell cultures, at least three vials should be inoculated with blood specimens, and two vials should be used for urine, tissue, and BAL samples.
Clinical Comparison of the Treponema pallidum CAPTIA Syphilis-G Enzyme Immunoassay with the Fluorescent Treponemal Antibody Absorption Immunoglobulin G Assay for Syphilis Testing
Halling, Valerie W., Jones, Mary F. , Bestrom, Jean E., Wold, Arlo D., Rosenblatt, Jon E., Smith, Thomas F., Cockerill, F. R., Cockerill, Franklin R.

Journal of Clinical Microbiology | December 31, 2019 | Volume: 37 | Issue: 10 | Pages: 3233-3234

10.1128/jcm.37.10.3233-3234.1999 Get It

ABSTRACT Recently, a treponema-specific immunoglobulin G (IgG) enzyme immunoassay (EIA), the CAPTIA Syphilis-G (Trinity Biotech, Jamestown, N.Y.), has become available as a diagnostic test for syphilis. A total of 89 stored sera previously tested by the fluorescent treponemal antibody absorption (FTA-ABS) IgG assay were evaluated by the CAPTIA EIA. The FTA-ABS IgG procedure was performed by technologists unblinded to results of rapid plasmid reagin (RPR) testing of the same specimens. Borderline CAPTIA-positive samples (antibody indices of ≥0.650 and ≤0.900) were retested; if the second analysis produced an index of >0.900, the sample was considered positive. Thirteen of 89 (15%) samples had discrepant results. Compared to the FTA-ABS assay, the CAPTIA EIA had a sensitivity and specificity and positive and negative predictive values of 70.7, 97.9, 96.7, and 79.7%, respectively. In another analysis, discrepancies between results were resolved by repeated FTA-ABS testing (technologists were blinded to previous RPR results) and patient chart reviews. Seven CAPTIA-negative samples which were previously interpreted (unblinded) as minimally reactive by the FTA method were subsequently interpreted (blinded) as nonreactive. One other discrepant sample (CAPTIA negative and FTA-ABS positive [at an intensity of 3+], unblinded) was FTA negative with repeated testing (blinded). For the five remaining discrepant samples, chart reviews indicated that one patient (CAPTIA negative and FTA-ABS positive [minimally reactive], blinded) had possible syphilis. These five samples were also evaluated and found to be negative by another treponema-specific test, the Treponema pallidum microhemagglutination assay. Therefore, after repeated testing and chart reviews, 2 of the 89 (2%) samples had discrepant results; the adjusted sensitivity, specificity, and positive and negative predictive values were 96.7, 98.3, 96.7, and 98.3%, respectively. This study demonstrates that the CAPTIA IgG EIA is a reliable method for syphilis testing and that personnel performing tests which require subjective interpretation, like the FTA-ABS test, may be biased by RPR test results.
Evaluation of LightCycler PCR for Implementation of Laboratory Diagnosis of Herpes Simplex Virus Infections
Espy, Mark J., Ross, Teri K., Teo, Rosaline, Svien, Kathleen A., Wold, Arlo D., Uhl, James R., Smith, Thomas F.

Journal of Clinical Microbiology | December 31, 2019 | Volume: 38 | Issue: 8 | Pages: 3116-3118

10.1128/jcm.38.8.3116-3118.2000 Get It

ABSTRACT Five hundred specimens (288 genital, 192 dermal, and 20 ocular) were extracted by technologists, and the DNA was assayed by LightCycler PCR (DNA polymerase and thymidine kinase [TK] gene targets) and by conventional tube and shell vial cell culture. One hundred fifty-eight confirmed (by cell culture and TK target PCR) positive and LightCycler-positive specimens were detected during the first 30 PCR cycles. LightCycler PCR-positive results for cycles 31 to 45 (39 of 67 [58.2%]) required confirmation by another PCR target (TK). LightCycler PCR is more sensitive ( n = 197; 23.1%) than cell cultures ( n = 150) for the routine laboratory detection of herpes simplex virus infections.
Diagnosis of Herpes Simplex Virus Infections in the Clinical Laboratory by LightCycler PCR
Espy, Mark J., Uhl, James R., Mitchell, P. Shawn, Thorvilson, Jill N., Svien, Kathleen A., Wold, Arlo D., Smith, Thomas F.

Journal of Clinical Microbiology | December 31, 2019 | Volume: 38 | Issue: 2 | Pages: 795-799

10.1128/jcm.38.2.795-799.2000 Get It

ABSTRACT Herpes simplex virus (HSV) causes several clinical manifestations in both normal and immunocompromised hosts; this agent is the most frequently detected virus in diagnostic laboratories. Recovery of the virus in cell culture is considered the “gold standard” for detection of this virus from sources other than cerebrospinal fluid. LightCycler is a newly developed, commercially available system designed to rapidly perform PCR, with real-time detection of PCR products by a fluorescence resonance energy transfer assay. We compared the detection of HSV for 200 specimens (number of genital specimens, 160; number of dermal specimens, 38; number of ocular specimens, 2) by shell vial cell cultures (MRC-5) and by LightCycler PCR. Of a total of 88 (44%) HSV strains detected, 69 (78%) were detected by both shell vial cell cultures and LightCycler PCR (DNA polymerase target). A total of 19 (22%) specimens were detected exclusively by LightCycler PCR. No specimens were positive by the shell vial assay only. All 19 discrepant samples had HSV DNA detected by an independent PCR directed to the thymidine kinase gene of the virus. The melting curve analysis feature of the LightCycler instrument identified identical genotype results for HSV type 1 (HSV-1) and HSV-2 from 84 of 88 (96%) positive samples. Specimens can be extracted, target HSV DNA can be amplified, and HSV PCR products can be identified by genotype within 2 h after receipt of specimen into the laboratory. The increased level of accurate identification (all 88 positive samples) compared with that of shell vial cell culture (69 of 88 samples identified as positive) and the agreement of LightCycler PCR results with all shell vial positive results indicate the potential for routine implementation of this technology for laboratory diagnosis of HSV infections.
Detection of Viral and Chlamydial Antigens in Open-Lung Biopsy Specimens
Gleaves, Curt A., Smith, Thomas F., Wold, Arlo D., Wilson, Walter R.

American Journal of Clinical Pathology | March 18, 2016 | Volume: 83 | Issue: 3 | Pages: 371-374

10.1093/ajcp/83.3.371 Get It

Detection of Herpes Simplex Virus DNA in Genital and Dermal Specimens by LightCycler PCR after Extraction using the IsoQuick, MagNA Pure, and BioRobot 9604 Methods
Espy, Mark J., Rys, Paul N., Wold, Arlo D., Uhl, James R., Sloan, Lynne M., Jenkins, G. Douglas , Ilstrup, Duane M., Cockerill, F. R., Patel, Robin , Rosenblatt, Jon E., Smith, Thomas F., Cockerill, Franklin R., Patel, Robin

Journal of Clinical Microbiology | July 27, 2002 | Volume: 39 | Issue: 6 | Pages: 2233-2236

10.1128/jcm.39.6.2233-2236.2001 Get It

ABSTRACT We evaluated two automated systems, MagNA Pure (Roche Molecular Biochemicals, Indianapolis, Ind.) and BioRobot 9604 (Qiagen, Inc., Chatsworth, Calif.) as effective replacements for the manual IsoQuick method (Orca Research, Inc., Bothell, Wash.) for extraction of herpes simplex virus (HSV) DNA from dermal and genital tract specimens prior to analysis by LightCycler PCR. Of 198 specimens (152 genital, 46 dermal), 92 (46.2%) were positive for HSV DNA by LightCycler PCR after automated extraction of specimens with either the MagNA Pure or BioRobot 9604 instrument. The manual IsoQuick method yielded HSV DNA (total n = 95) from three additional specimens that were negative by the automated method ( P = 0.25, sign test). Although the mean numbers of LightCycler PCR cycles required to reach positivity differed statistically significantly among all three of the methods of extraction, the estimated means differed by no more than 1.5 cycles ( P < 0.05). Seventy (76%) of the 92 specimens that were LightCycler PCR positive by all three extraction methods were also positive by shell vial cell culture assay. HSV DNA was detected by a lower LightCycler PCR cycle number (26.1 cycles) in specimens culture positive for the virus than in culture-negative samples (33.3 cycles) ( P < 0.0001). The manual IsoQuick and automated MagNA Pure and BioRobot 9604 methods provide standardized, reproducible extraction of HSV DNA for LightCycler PCR. The decision to implement a manual versus an automated procedure depends on factors such as costs related to the number of specimens processed rather than on the minimal differences in the technical efficiency of extraction of nucleic acids among these methods.