Back to Authors

Cockerill, Franklin R.

Mayo Clinic

Mayo Clinic

Citations 58

Spectromicroscopy of microbial signatures within human calcifications
Miller, Virginia M. , Uhl, James R., Cockerill, Franklin R., Farell‐Baril, Gerard, Tyliszczak, Tolek , Brown, Gordon E. , Benzerara, Karim , Lieske, John C.

The FASEB Journal | June 21, 2021 | Volume: 20 | Issue: 4 | Pages: No page available

10.1096/fasebj.20.4.a101-a Get It

The microbiologic nature of self‐replicating, calcifying entity nanoparticles (NPs) isolated from calcified human tissues, including blood vessels and kidney stones is debated because of the difficulty in discriminating minerals precipitated on microbes from minerals nucleated on macromolecules and cell membranes. To begin to resolve this controversy, calcifying bacteria of aquatic origin ( Caulobacter crescentus ) and NPs cultured from human samples were examined using a Scanning Transmission X‐ray Microscope (STXM). The monochromated soft X‐ray beam (150–2000 eV) produced by synchrotron radiation yields microscopic and spectroscopic information on both organic compounds and minerals at the 25 nm scale. High‐spatial and energy resolution Near‐Edge X‐ray Absorption Fine Structure (NEXAFS) spectra indicative of elemental speciation acquired at the C K‐edge and Ca L 2,3 ‐edge on a single‐cell scale from calcified C. crescentus displayed a unique spectral signature different from non‐biologic hydroxyapatite (Ca 10 (PO 4 ) 6 (OH) 2 ). Preliminary NEXAFS measurements of calcium and carbon functional groups of cultured NPs revealed organics associated with hydroxyapatite minerals and in one case, spectroscopic signatures similar to those identified in C. crescentus . Using NEXAFS, it is possible to define a biochemical signature of proteins, polysaccharides, nucleic acids, and hydroxyapatite for cultured calcified bacteria suggesting that NPs isolated from human samples share spectroscopic characteristics with calcifying bacteria.
Clinical comparison of BACTEC 9240 plus aerobic/F resin bottles and the isolator aerobic culture system for detection of bloodstream infections
Cockerill, Franklin R., Reed, G S, Torgerson, C A, Vetter, Emily A., Harmsen, William S. , Dale, J C, Roberts, Glenn D., Ilstrup, D M, Henry, Nancy K., Hughes, J G

Journal of Clinical Microbiology | January 6, 2020 | Volume: 35 | Issue: 6 | Pages: 1469-1472

10.1128/jcm.35.6.1469-1472.1997 Get It

The Plus Aerobic/F resin bottle of the BACTEC 9240 automated blood culture system (Becton Dickinson Diagnostic Instrument Systems, Sparks, Md.) was compared with aerobic culture of the Isolator system (Wampole Laboratories, Cranbury, N.J.) for the detection of bloodstream microorganisms from 6,145 blood cultures collected from adult patients with suspected septicemia. The BACTEC resin bottles were incubated for 7 days, and the sediment from the Isolator tube was inoculated to sheep blood and chocolate agars which were incubated for 72 h and to inhibitory mold, brain heart infusion, and Sabouraud agars which were incubated for 21 days. A total of 622 microorganisms were recovered from 583 blood cultures. The BACTEC resin bottle recovered statistically significantly more pathogens overall than the Isolator system (P = 0.0006). When individual pathogens isolated from either system for a 7-day study period were assessed, it was determined that the BACTEC resin bottle detected statistically significantly more isolates of Staphylococcus aureus (P = 0.0113) and coagulase-negative Staphylococcus spp. (P = 0.0029) than the Isolator system. The BACTEC resin bottle also detected statistically significantly more bloodstream infections (septic episodes) caused by coagulase-negative Staphylococcus spp. (P = 0.0146). The Isolator system recovered statistically significantly more contaminants overall (P < 0.0001), and among this group of microorganisms, recovered statistically significantly more Bacillus spp. (P < 0.0001), coagulase-negative Staphylococcus spp. (P < 0.0001), and viridans group Streptococcus spp. (P = 0.0156). The Isolator system detected statistically significantly more isolates of Histoplasma capsulatum (P = 0.004), but all of these isolates were detected at > or = 7 days of incubation of fungal plates, i.e., after the system to system comparison study period (7 days). In blood culture sets which produced growth of the same pathogen in both systems, there was a statistically significant difference in median time to detection for all pathogens combined favoring the BACTEC resin bottle over the Isolator tube (P < 0.05). When assessing individual microorganisms, the median times for detection of S. aureus, Enterococcus spp., and Pseudomonas spp. were all statistically significantly less for the BACTEC system (P < 0.05). The BACTEC instrument had 79 (1.3%) false positive signals. The BACTEC system required less processing time than the Isolator system and eliminates the hands-on time for detection of positive cultures required with the Isolator system.
Comparison of agar dilution, broth microdilution, disk diffusion, E-test, and BACTEC radiometric methods for antimicrobial susceptibility testing of clinical isolates of the Nocardia asteroides complex
Ambaye, A, Kohner, Peggy C., Wollan, Peter C. , Roberts, K L, Roberts, Glenn D., Cockerill, Franklin R.

Journal of Clinical Microbiology | January 6, 2020 | Volume: 35 | Issue: 4 | Pages: 847-852

10.1128/jcm.35.4.847-852.1997 Get It

An evaluation was undertaken to determine the optimal method for the in vitro susceptibility testing of 26 Nocardia asteroides complex isolates to the following antimicrobial agents: amikacin, ampicillin, amoxicillin-clavulanate, ceftriaxone, ciprofloxacin, erythromycin, imipenem, minocycline, and trimethoprim-sulfamethoxazole. Five testing methods were studied including the agar dilution, broth microdilution, and disk diffusion methods, the epsilometer test (E-test), and the BACTEC radiometric method. Results for each antimicrobial agent and each testing method were interpreted as indicating susceptibility, intermediate susceptibility, or resistance according to current guidelines of the National Committee for Clinical Laboratory Standards (NCCLS) for bacteria that grow aerobically and were then compared to a "gold standard" susceptibility test result. The gold standard result for each Nocardia isolate was established by a consensus of the results of the majority of testing methods used in the study. When the results were combined for all antimicrobial agents tested against all Nocardia isolates by all methods, the BACTEC radiometric method produced the highest level of agreement (97.9%) with the consensus results and had the fewest very major (n = 1), major (n = 2), and minor (n = 2) errors. In contrast, the results of the agar dilution method were in least agreement (93.2%) with the consensus results, and this method also produced the most very major (n = 8), major (n = 4), and, along with the disk diffusion method, minor (n = 6) errors. For all test methods, interpretive errors were most frequent when testing ampicillin or amoxicillin-clavulanate. Moreover, for all Nocardia nova isolates tested, ampicillin susceptibility results by any of the testing methods were not in agreement with the results of testing for beta-lactamase by the nitrocefin (Cefinase) disk method. We conclude that among the methods evaluated, the BACTEC radiometric method appeared to be the best for determining the in vitro susceptibilities of members of the N. asteroides complex to a panel of nine antimicrobial agents. However, none of the test methods, including the BACTEC method, accurately predicted the ampicillin resistance of the N. nova isolates tested, all of which produced beta-lactamase. Presuming that this beta-lactamase hydrolyzes ampicillin, this disparity may relate to the NCCLS breakpoints that were used, which may require modification for this antimicrobial agent when tested against N. nova isolates.
Comparison of agar dilution, broth microdilution, E-test, disk diffusion, and automated Vitek methods for testing susceptibilities of Enterococcus spp. to vancomycin
Kohner, Peggy C., Patel, Robin , Uhl, J. R., Garin, K M, Hopkins, Marlene K., Wegener, L T, Cockerill, Franklin R., Patel, Robin

Journal of Clinical Microbiology | January 6, 2020 | Volume: 35 | Issue: 12 | Pages: 3258-3263

10.1128/jcm.35.12.3258-3263.1997 Get It

An evaluation was undertaken to determine the optimal method for testing the susceptibilities of 100 clinical isolates and two reference strains of Enterococcus spp. to vancomycin in vitro. Six testing methods were studied by using the following media and incubation times: agar screen with the Synergy Quad Plate (Remel, Lenexa, Kans.), an in-house-prepared brain heart infusion (BHI) agar plate, and an in-house-prepared Mueller-Hinton (MH) agar plate, all incubated for 24 or 48 h; broth microdilution (Sensititre Just One Strip; AccuMed International, Inc., West Lake, Ohio) with BHI or cation-adjusted MH broth incubated for 24 or 48 h; agar dilution with BHI or MH agar incubated for 24 or 48 h; epsilometer test (E test; AB BioDisk, Solna, Sweden) with BHI or MH agar incubated for 24 or 48 h; disk diffusion with BHI or MH agar incubated for 24 or 48 h; and the automated Vitek method with the gram-positive susceptibility Staphylococcus aureus card and R02.03 software (bioMerieux, Inc., Hazelwood, Mo.). Growth failures occurred with MH media (n = 6) but not with BHI media. One growth failure occurred with the Vitek method. Results for each testing method for each Enterococcus strain were interpreted as susceptible, intermediate, or resistant according to current National Committee for Clinical Laboratory Standards (NCCLS) criteria and compared to the vancomycin resistance genotype (i.e., vanA, vanB, vanC-1, or vanC-2/3). For all methods, extension of the incubation time from 24 h to 48 h either produced no difference in the results or gave poorer results. The following methods produced no very major or major interpretive errors: broth microdilution with BHI media incubated for 24 h, agar dilution with BHI media incubated for 24 or 48 h, and E test with BHI media incubated for 24 or 48 h. Unacceptable frequencies of very major errors (> 1%) occurred with all methods for which MH media were used. Minor interpretive errors were frequent with all methods. These minor interpretive errors also occurred most frequently with Enterococcus strains with vanC genes, which encoded low-level vancomycin resistance (MIC < or = 8 microg/ml), as opposed to Enterococcus strains which possessed vanA or vanB genes, which encoded higher-level vancomycin resistance (MIC > or = 64 microg/ml). Modification of NCCLS breakpoints, especially for motile Enterococcus spp. (E. casseliflavus, E. flavescens, and E. gallinarum), may resolve this problem; however, in the current study, one E. faecalis strain and one E. faecium strain carried only the vanC gene. The agar screen method may also require reformulation. The current agar screen plate contains 6 microg of vancomycin per ml, which may not detect all low-level resistance associated with vanC genotypes. Nevertheless, the clinical significance of this low-level vancomycin resistance remains unknown.
Assessment of routine use of an anaerobic bottle in a three-component, high-volume blood culture system
Hellinger, Walter C. , Cawley, John J., Alvarez, S., Hogan, Stephen F., Harmesen, W S, Ilstrup, D M, Cockerill, Franklin R.

Journal of Clinical Microbiology | January 6, 2020 | Volume: 34 | Issue: 10 | Pages: 2544-2547

10.1128/jcm.34.10.2544-2547.1996 Get It

The relative value of routine anaerobic blood culture for recovery of organisms and identification of episodes of bloodstream infection was assessed in a three-component, high-volume blood culture system which employs aerobic and anaerobic bottles of BacT/Alert (Organon-Teknika, Durham, N.C.) and aerobic cultures of Isolator (Wampole Laboratories, Cranbury, N.J.). The results of 5,595 blood culture sets from patients with suspected bloodstream infection were analyzed. Compared with either the aerobic BacT/Alert bottle or aerobic culture of Isolator, the BacT/Alert anaerobic bottle recovered significantly fewer isolates (242 versus 294, P < 0.05; 242 versus 298, P < 0.05) but did not detect significantly fewer episodes of bloodstream infection (141 versus 157, P > 0.05; 141 versus 147, P > 0.05). The BacT/Alert anaerobic bottle recovered significantly more isolates of obligately anaerobic bacteria (16 versus 4, P < 0.05; 16 versus 0, P < 0.05) and detected significantly more episodes of bloodstream infection caused by obligately anaerobic bacteria (10 versus 3, P < 0.05; 10 versus 0, P < 0.05) than either the aerobic bottle of BacT/Alert or the aerobic culture of Isolator. The combination of the BacT/Alert anaerobic bottle and the aerobic culture of Isolator recovered as may isolates (374 versus 377) and detected as many episodes of bloodstream infection (194 versus 191) as the combination of the aerobic bottle of BacT/Alert and the aerobic culture of Isolator, and both of these combinations identified at least 8% more isolates and detected at least 3% more bloodstream infections than the combination of the BacT/Alert aerobic and anaerobic bottles. Further analysis of the data revealed that the utility of the BacT/Alert anaerobic bottle, especially when combined with the aerobic culture of Isolator, resulted from not only enhanced recovery of obligately anaerobic bacteria but also effective recovery of facultatively anaerobic bacteria. These results demonstrate the utility of the anaerobic BacT/Alert bottle for detecting bloodstream infection caused by either facultatively anaerobic bacteria or obligately anaerobic bacteria and support the routine inclusion of anaerobic blood culture in the three-component blood culture system used in our hospital.
Clinical comparison of isolator, Septi-Chek, nonvented tryptic soy broth, and direct agar plating combined with thioglycolate broth for diagnosing spontaneous bacterial peritonitis
Hay, J. Eileen, Cockerill, Franklin R., Kaese, D, Vetter, Emily A., Wollan, Peter C. , Rakela, J., Wilhelm, Mark

Journal of Clinical Microbiology | January 6, 2020 | Volume: 34 | Issue: 1 | Pages: 34-37

10.1128/jcm.34.1.34-37.1996 Get It

Spontaneous bacterial peritonitis is a life-threatening complication of cirrhotic ascites. Optimal patient management depends on the isolation of the causal organism from ascitic fluid. To evaluate culture techniques for the diagnosis of spontaneous bacterial peritonitis, we prospectively compared three blood culture system, the Isolator system, a lysis-centrifugation system, the Septi-Chek system, a biphasic culture system, and a nonvented tryptic soy broth system, all inoculated at the bedside, and our standard method of direct inoculation of specimens after transport to the laboratory onto agar plates and into thioglycolate broth. The results showed that the Septi-Chek and nonvented tryptic soy broth systems each recovered statistically significantly more pathogens than either the Isolator system (P = 0.0084) or the standard method (P = 0.00098). The Isolator system recovered more pathogens than the standard plate method, but this difference was not statistically significant. Both the Isolator system and the standard plate method recovered more contaminating microorganisms than the Septi-Chek or nonvented tryptic soy broth system. The Isolator system required the most processing time compared with the processing times required by any other method.
Clinical comparison of difco ESP, Wampole isolator, and Becton Dickinson Septi-Chek aerobic blood culturing systems
Cockerill, Franklin R., Torgerson, C A, Reed, G S, Vetter, Emily A., Weaver, Amy L. , Dale, J C, Roberts, Glenn D., Henry, Nancy K., Ilstrup, D M, Rosenblatt, Jon E.

Journal of Clinical Microbiology | January 6, 2020 | Volume: 34 | Issue: 1 | Pages: 20-24

10.1128/jcm.34.1.20-24.1996 Get It

The ESP 80A aerobic blood culture of the ESP automated blood culture system (Difco Laboratories. Detroit, Mich.) was compared with two manual aerobic blood culture systems, the Isolator (Wampole Laboratories, Cranbury, N.J.) and the Septi-Chek (Becton Dickinson, Cockeysville, Md.) systems, for the detection of bloodstream microorganisms from 5,845 blood samples for culture collected from adult patients with suspected septicemia. The bottles were incubated for 7 days, and the sediment from the Isolator tube was inoculated onto solid medium and this medium was incubated for 72 h. A total of 609 microorganisms were recovered from 546 blood cultures. There was no statistically significant difference in the total recovery of microorganisms for the ESP 80A system when compared with that for the Septi-Chek system (P = 0.083); however, the Isolator system recovered significantly more microorganisms overall than either the ESP 80A (P < 0.001) or the Septi-Chek (P < 0.001) system. When assessing individual probable pathogens, the Isolator system detected statistically significantly more Staphylococcus aureus and Candida spp. than either the ESP 80A or the Septi-Chek system (P < 0.05). Similarly, the Isolator system detected statistically significantly more bloodstream infections (septic episodes) caused by S. aureus and Candida spp. than either the ESP 80A or the Septi-Chek system (P < 0.05). In blood culture sets which produced growth of the same probable pathogens in the ESP 80A and the Isolator systems, there was no statistically significant difference in the median times to detection for all pathogens combined (P = 0.067). However, a similar comparison showed the Isolator and the ESP 80A systems to have statistically significantly shorter median detection times for all pathogens combined (P < 0.001) when they were independently compared with the Septi-Chek system. The ESP 80A system had 29 (0.5%) false-positive signals. The ESP system required less processing time than the Isolator system and eliminates the hands-on time for the detection of positive cultures required by the manual systems.
Clinical comparison of the isolator and BacT/Alert aerobic blood culture systems
Hellinger, Walter C. , Cawley, John J., Alvarez, S., Hogan, Stephen F., Harmsen, William S. , Ilstrup, D M, Cockerill, Franklin R.

Journal of Clinical Microbiology | January 6, 2020 | Volume: 33 | Issue: 7 | Pages: 1787-1790

10.1128/jcm.33.7.1787-1790.1995 Get It

The performance characteristics of the Isolator (Wampole Laboratories, Cranbury, N.J.) and the BacT/Alert (Organon Teknika Corporation, Durham, N.C.) aerobic blood culture systems were compared for 6,009 blood culture sets obtained from patients with suspected bloodstream infections. The BacT/Alert aerobic bottle [BTA(O2)] was continuously agitated while it was incubated in 5% CO2 at 36 degrees C; culture plates prepared from the Isolator tube [I(O2)] were incubated in 5% CO2 at 37 degrees C. From 394 blood cultures, 416 clinically significant isolates of bacteria and yeasts were recovered. The overall yields for BTA(O2) and I(O2) were not significantly different (319 versus 336; P = 0.20). I(O2) recovered significantly more staphylococcus (P < 0.05) and yeast isolates (P < 0.01). BTA(O2) recovered significantly more aerobic and facultatively anaerobic gram-negative bacilli (P < 0.05). In blood culture sets which produced growth of the same organisms in both the BTA(O2) and I(O2) systems, the BTA(O2) system detected growth sooner, but more rapid identification was possible with the I(O2) system by virtue of earlier isolation of colonies on solid media.
Multiplex PCR detection of vanA, vanB, vanC-1, and vanC-2/3 genes in enterococci
Patel, Robin , Uhl, J. R., Kohner, Peggy C., Hopkins, Marlene K., Cockerill, F. R., Patel, Robin , Cockerill, Franklin R.

Journal of Clinical Microbiology | January 6, 2020 | Volume: 35 | Issue: 3 | Pages: 703-707

10.1128/jcm.35.3.703-707.1997 Get It

Vancomycin-resistant enterococci (VRE) are increasingly isolated from clinical specimens. One hundred clinical isolates of enterococci (E. casseliflavus/E. flavescens [n = 10], E. faecalis [n = 34], E. faecium [n = 43], E. avium [n = 1], E. gallinarum [n = 11], and E. raffinosus [n = 1]) were examined for the presence of vanA, vanB, vanC-1, and vanC-2/3 genes by a single multiplex PCR performed directly with colonies from blood agar plates. Six previously characterized VRE strains which carry either vanA, vanB, vanC-1, or vanC-2 genes were used as controls. To discriminate among van genes, the PCR amplicons were digested with MspI and were electrophoresed on agarose gels. Because of significant sequence homology between vanC-2 and vanC-3 genes, this assay is unable to discriminate these genes from each other; therefore, these are referred to as vanC-2/3 genes. PCR products were detected in 63 of the 100 clinical isolates. The restriction fragment length patterns were consistent with vanA for 10 strains, vanB for 30 strains, vanC-1 for 12 strains, vanC-2 for 6 strains, and vanA and vanC-1 for 1 strain. The vancomycin MICs for the isolates with restriction fragment length patterns consistent with vanA and vanB were all > and = 64 micrograms/ml. The vancomycin MICs for the isolates with restriction fragment length patterns consistent with vanC-1 or vanC-2 were 4 to 8 micrograms/ml. The vancomycin MICs for the isolates from which no PCR amplicons were produced were 2 to 4 micrograms/ml. A PCR product was produced in four isolates (vancomycin MICs, 4 to > 256 micrograms/ml) with restriction fragment length patterns differing from those for the control vanA, vanB, vanC-1, and vanC-2 isolates. DNA sequencing of these amplicons revealed that two of the four isolates had nucleic acid sequences which were closely related to the published sequence for the vanB gene and two had nucleic acid sequences which were closely related to the published sequence for the vanC-2 and vanC-3 genes. Multiplex PCR-restriction fragment length polymorphism appears to be a useful and convenient method for rapidly detecting and discriminating genotypes for vancomycin-resistant Enterococcus spp. in the clinical laboratory. In instances in which unusual restriction fragment patterns of PCR amplicons occur, DNA sequencing can be performed to discriminate van genotypes.
Evaluation of an immunoassay for direct detection of Escherichia coli O157 in stool specimens
Dylla, Brenda L., Vetter, Emily A., Cockerill, Franklin R., Hughes, J G

Journal of Clinical Microbiology | January 6, 2020 | Volume: 33 | Issue: 1 | Pages: 222-224

10.1128/jcm.33.1.222-224.1995 Get It

An enzyme-linked immunosorbent assay (ELISA) produced by LMD Laboratories, Inc., Carlsbad, Calif., was compared with culture for the detection of Escherichia coli O157. Nine of 185 stool specimens evaluated had positive results by the LMD E. coli O157 ELISA and grew E. coli O157 on culture; 174 had negative by LMD E. coli O157 ELISA results and did not grow E. coli O157 on culture. Of 174 specimens negative by LMD E. coli O157 ELISA, 117 specimens grew other enteric pathogens: Campylobacter spp. (46 isolates), Salmonella spp. (43 isolates), Yersinia spp. (20 isolates), and Shigella spp. (8 isolates). There were two indeterminant results by the LMD E. coli O157 ELISA. One stool specimen did not grow other enteric pathogens on culture, and one grew a Campylobacter sp. on culture. Both had negative LMD E. coli O157 ELISA results upon repeat testing. The LMD E. coli O157 ELISA is an accurate, easy-to-read screening method for the detection of E. coli O157 in fecal specimens.