Simplified Approach to Identification of Aerobic Actinomycetes by Thin-Layer Chromatography
Staneck, Joseph L., Roberts, Glenn D.

Applied Microbiology | December 5, 2020 | Volume: 28 | Issue: 2 | Pages: 226-231

10.1128/am.28.2.226-231.1974 Get It

A system has been developed for the identification of aerobic actinomycetes in the clinical laboratory based on analysis of whole cells for diaminopimelic acid and carbohydrates and on the ability of the organism to decompose casein, tyrosine, and xanthine media. The whole-cell analyses were performed by a simple thin-layer chromatographic procedure that is described. Eighteen reference cultures were correctly identified and, subsequently, 35 isolates from clinical material were grouped by using this system. The method is well suited for use in routine clinical laboratories.
Clinical comparison of BACTEC 9240 plus aerobic/F resin bottles and the isolator aerobic culture system for detection of bloodstream infections
Cockerill, Franklin R., Reed, G S, Torgerson, C A, Vetter, Emily A., Harmsen, William S. , Dale, J C, Roberts, Glenn D., Ilstrup, D M, Henry, Nancy K., Hughes, J G

Journal of Clinical Microbiology | January 6, 2020 | Volume: 35 | Issue: 6 | Pages: 1469-1472

10.1128/jcm.35.6.1469-1472.1997 Get It

The Plus Aerobic/F resin bottle of the BACTEC 9240 automated blood culture system (Becton Dickinson Diagnostic Instrument Systems, Sparks, Md.) was compared with aerobic culture of the Isolator system (Wampole Laboratories, Cranbury, N.J.) for the detection of bloodstream microorganisms from 6,145 blood cultures collected from adult patients with suspected septicemia. The BACTEC resin bottles were incubated for 7 days, and the sediment from the Isolator tube was inoculated to sheep blood and chocolate agars which were incubated for 72 h and to inhibitory mold, brain heart infusion, and Sabouraud agars which were incubated for 21 days. A total of 622 microorganisms were recovered from 583 blood cultures. The BACTEC resin bottle recovered statistically significantly more pathogens overall than the Isolator system (P = 0.0006). When individual pathogens isolated from either system for a 7-day study period were assessed, it was determined that the BACTEC resin bottle detected statistically significantly more isolates of Staphylococcus aureus (P = 0.0113) and coagulase-negative Staphylococcus spp. (P = 0.0029) than the Isolator system. The BACTEC resin bottle also detected statistically significantly more bloodstream infections (septic episodes) caused by coagulase-negative Staphylococcus spp. (P = 0.0146). The Isolator system recovered statistically significantly more contaminants overall (P < 0.0001), and among this group of microorganisms, recovered statistically significantly more Bacillus spp. (P < 0.0001), coagulase-negative Staphylococcus spp. (P < 0.0001), and viridans group Streptococcus spp. (P = 0.0156). The Isolator system detected statistically significantly more isolates of Histoplasma capsulatum (P = 0.004), but all of these isolates were detected at > or = 7 days of incubation of fungal plates, i.e., after the system to system comparison study period (7 days). In blood culture sets which produced growth of the same pathogen in both systems, there was a statistically significant difference in median time to detection for all pathogens combined favoring the BACTEC resin bottle over the Isolator tube (P < 0.05). When assessing individual microorganisms, the median times for detection of S. aureus, Enterococcus spp., and Pseudomonas spp. were all statistically significantly less for the BACTEC system (P < 0.05). The BACTEC instrument had 79 (1.3%) false positive signals. The BACTEC system required less processing time than the Isolator system and eliminates the hands-on time for detection of positive cultures required with the Isolator system.
Comparison of agar dilution, broth microdilution, disk diffusion, E-test, and BACTEC radiometric methods for antimicrobial susceptibility testing of clinical isolates of the Nocardia asteroides complex
Ambaye, A, Kohner, Peggy C., Wollan, Peter C. , Roberts, K L, Roberts, Glenn D., Cockerill, Franklin R.

Journal of Clinical Microbiology | January 6, 2020 | Volume: 35 | Issue: 4 | Pages: 847-852

10.1128/jcm.35.4.847-852.1997 Get It

An evaluation was undertaken to determine the optimal method for the in vitro susceptibility testing of 26 Nocardia asteroides complex isolates to the following antimicrobial agents: amikacin, ampicillin, amoxicillin-clavulanate, ceftriaxone, ciprofloxacin, erythromycin, imipenem, minocycline, and trimethoprim-sulfamethoxazole. Five testing methods were studied including the agar dilution, broth microdilution, and disk diffusion methods, the epsilometer test (E-test), and the BACTEC radiometric method. Results for each antimicrobial agent and each testing method were interpreted as indicating susceptibility, intermediate susceptibility, or resistance according to current guidelines of the National Committee for Clinical Laboratory Standards (NCCLS) for bacteria that grow aerobically and were then compared to a "gold standard" susceptibility test result. The gold standard result for each Nocardia isolate was established by a consensus of the results of the majority of testing methods used in the study. When the results were combined for all antimicrobial agents tested against all Nocardia isolates by all methods, the BACTEC radiometric method produced the highest level of agreement (97.9%) with the consensus results and had the fewest very major (n = 1), major (n = 2), and minor (n = 2) errors. In contrast, the results of the agar dilution method were in least agreement (93.2%) with the consensus results, and this method also produced the most very major (n = 8), major (n = 4), and, along with the disk diffusion method, minor (n = 6) errors. For all test methods, interpretive errors were most frequent when testing ampicillin or amoxicillin-clavulanate. Moreover, for all Nocardia nova isolates tested, ampicillin susceptibility results by any of the testing methods were not in agreement with the results of testing for beta-lactamase by the nitrocefin (Cefinase) disk method. We conclude that among the methods evaluated, the BACTEC radiometric method appeared to be the best for determining the in vitro susceptibilities of members of the N. asteroides complex to a panel of nine antimicrobial agents. However, none of the test methods, including the BACTEC method, accurately predicted the ampicillin resistance of the N. nova isolates tested, all of which produced beta-lactamase. Presuming that this beta-lactamase hydrolyzes ampicillin, this disparity may relate to the NCCLS breakpoints that were used, which may require modification for this antimicrobial agent when tested against N. nova isolates.
Clinical comparison of difco ESP, Wampole isolator, and Becton Dickinson Septi-Chek aerobic blood culturing systems
Cockerill, Franklin R., Torgerson, C A, Reed, G S, Vetter, Emily A., Weaver, Amy L. , Dale, J C, Roberts, Glenn D., Henry, Nancy K., Ilstrup, D M, Rosenblatt, Jon E.

Journal of Clinical Microbiology | January 6, 2020 | Volume: 34 | Issue: 1 | Pages: 20-24

10.1128/jcm.34.1.20-24.1996 Get It

The ESP 80A aerobic blood culture of the ESP automated blood culture system (Difco Laboratories. Detroit, Mich.) was compared with two manual aerobic blood culture systems, the Isolator (Wampole Laboratories, Cranbury, N.J.) and the Septi-Chek (Becton Dickinson, Cockeysville, Md.) systems, for the detection of bloodstream microorganisms from 5,845 blood samples for culture collected from adult patients with suspected septicemia. The bottles were incubated for 7 days, and the sediment from the Isolator tube was inoculated onto solid medium and this medium was incubated for 72 h. A total of 609 microorganisms were recovered from 546 blood cultures. There was no statistically significant difference in the total recovery of microorganisms for the ESP 80A system when compared with that for the Septi-Chek system (P = 0.083); however, the Isolator system recovered significantly more microorganisms overall than either the ESP 80A (P < 0.001) or the Septi-Chek (P < 0.001) system. When assessing individual probable pathogens, the Isolator system detected statistically significantly more Staphylococcus aureus and Candida spp. than either the ESP 80A or the Septi-Chek system (P < 0.05). Similarly, the Isolator system detected statistically significantly more bloodstream infections (septic episodes) caused by S. aureus and Candida spp. than either the ESP 80A or the Septi-Chek system (P < 0.05). In blood culture sets which produced growth of the same probable pathogens in the ESP 80A and the Isolator systems, there was no statistically significant difference in the median times to detection for all pathogens combined (P = 0.067). However, a similar comparison showed the Isolator and the ESP 80A systems to have statistically significantly shorter median detection times for all pathogens combined (P < 0.001) when they were independently compared with the Septi-Chek system. The ESP 80A system had 29 (0.5%) false-positive signals. The ESP system required less processing time than the Isolator system and eliminates the hands-on time for the detection of positive cultures required by the manual systems.
Direct genotypic detection of Mycobacterium tuberculosis rifampin resistance in clinical specimens by using single-tube heminested PCR
Whelen, A. Christian , Felmlee, Teresa A., Hunt, John, Williams, Diana L., Roberts, Glenn D., Stockman, L, Persing, David H., Hunt, J M

Journal of Clinical Microbiology | January 6, 2020 | Volume: 33 | Issue: 3 | Pages: 556-561

10.1128/jcm.33.3.556-561.1995 Get It

Recent analysis of the gene encoding the beta subunit of Mycobacterium tuberculosis RNA polymerase (rpoB) has demonstrated a small region that harbors the mutations most frequently associated with rifampin resistance. Earlier reports have described a high degree of sequence conservation of rpoB among mycobacteria other than M. tuberculosis and other GC-rich bacteria that can lead to false-positive amplification when applied directly to clinical specimens. We developed reagents for PCR amplification that are based on signature nucleotides discovered by comparative sequence analysis of the rpoB genes of organisms phylogenetically related to M. tuberculosis. The specificities of the reagents were challenged with 20 isolates of multiple-drug-resistant M. tuberculosis and more than 20 species of mycobacteria other than M. tuberculosis and other GC-rich organisms. A single-tube heminested PCR protocol was devised to obtain sensitivity equal to those of an IS6110-based PCR assay and culture in spiked sputum experiments. The assay correctly identified 21 of 24 (87.5%) culture-positive specimens, 13 of which were acid-fast smear-negative, in a panel of 51 clinical specimens. Three specimens that were false-positive initially were negative upon repeat testing when the assay was modified to eliminate the potential for aerosol carryover of the first-round amplification product during the open-tube addition of the second set of reaction reagents. This assay is the most sensitive and specific test to date for the direct detection of M. tuberculosis rpoB in clinical specimens. This rapid PCR-based assay can be used for the simultaneous identification of M. tuberculosis and its rifampin susceptibility genotype.
Molecular probes for diagnosis of fungal infections
Sandhu, Gurpreet , Kline, B C, Stockman, L, Roberts, Glenn D.

Journal of Clinical Microbiology | January 6, 2020 | Volume: 33 | Issue: 11 | Pages: 2913-2919

10.1128/jcm.33.11.2913-2919.1995 Get It

We have developed 21 specific nucleic acid probes which target the large subunit rRNA genes from Aspergillus flavus, Aspergillus fumigatus, Aspergillus glaucus, Aspergillus niger, Aspergillus terreus, Blastomyces dermatitidis, Candida albicans, Candida (Torulopsis) glabrata, Candida guilliermondii, Candida kefyr, Candida krusei, Candida lusitaniae, Candida parapsilosis, Candida tropicalis, Coccidioides immitis, Cryptococcus neoformans var. gattii, Cryptococcus neoformans var. neoformans, Filobasidiella neoformans var. bacillispora, Filobasidiella neoformans var. neoformans, Histoplasma capsulatum, Pseudallescheria boydii, and Sporothrix schenckii. A section of the 28S rRNA gene from approximately 100 fungi, representing about 50 species of pathogens and commonly encountered saprophytes, was sequenced to develop universal PCR primers and species-specific oligonucleotide probes. Each step in the process of detection and identification was standardized to a common set of conditions applicable without modification to all fungi of interest and all types of clinical specimens. These steps consist of DNA extraction by boiling specimens in an alkaline guanidine-phenol-Tris reagent, amplification of a variable region of the 28S rRNA gene with universal primers, and amplicon identification by probe hybridization or DNA sequencing performed under conditions identical for all fungi. The results obtained by testing a panel of fungal isolates and a variety of clinical specimens indicate a high level of specificity.
Evaluation of commercially available acridinium ester-labeled chemiluminescent DNA probes for culture identification of Blastomyces dermatitidis, Coccidioides immitis, Cryptococcus neoformans, and Histoplasma capsulatum
Stockman, L, Clark, Kristen , Hunt, John, Roberts, Glenn D., Hunt, J M

Journal of Clinical Microbiology | January 5, 2020 | Volume: 31 | Issue: 4 | Pages: 845-850

10.1128/jcm.31.4.845-850.1993 Get It

Four commercially available acridinium ester-labeled DNA probes directed against rRNA were evaluated for their ability to identify Blastomyces dermatitidis, Coccidioides immitis, Histoplasma capsulatum, and Cryptococcus neoformans in culture. rRNA was extracted by sonication of 1- to 2-mm2 portions of cultures of fungi in two chaotropic reagents with glass beads. Following a heat inactivation step, the extracts were hybridized in solution with probes specific for each pathogen. The acridinium ester reporter moiety of nonhybridized probe was selectively hydrolyzed, and chemiluminescence of specific DNA:RNA hybrids was quantitated in relative light units with a luminometer. A positive identification required a relative light unit value of > or = 50,000. Sensitivity and specificity of the probes were determined by probing cultures of the respective pathogenic fungi (target) and nontarget fungi. Both mycelial and yeast forms of the dimorphic fungi (B. dermatitidis and H. capsulatum) were tested. For B. dermatitidis, sensitivity and specificity were 87.8 and 100%, respectively (74 target and 219 nontarget fungi tested). For C. immitis, sensitivity and specificity were 99.2 and 100%, respectively (122 target and 164 nontarget fungi tested). For H. capsulatum, sensitivity and specificity were 100 and 100%, respectively (86 target and 154 nontarget fungi tested). For C. neoformans, sensitivity and specificity were 97 and 100%, respectively (100 target and 230 nontarget fungi tested). For B. dermatitidis, C. immitis, and C. neoformans, repeat testing increased the respective sensitivities to 97.3, 100, and 100%. The high sensitivities and specificities of the probes, the relatively short time (less than 1 h) required to perform the assay, and the availability of standardized reagent kits make the acridinium ester-labeled DNA probes well suited to laboratories in need of a rapid method to identify these fungal pathogens. Further, use of the probes to identify pathogenic fungi as soon as colonies appear on primary recovery media significantly shortens the time to reporting.
Experience with the use of pronase to eliminate interference factors in the latex agglutination test for cryptococcal antigen
Gray, L D, Roberts, Glenn D.

Journal of Clinical Microbiology | January 5, 2020 | Volume: 26 | Issue: 11 | Pages: 2450-2451

10.1128/jcm.26.11.2450-2451.1988 Get It

Cryptococcal antigen titers of 70 cerebrospinal fluid and 57 serum specimens from patients suspected of having cryptococcosis were determined both before and after treatment with pronase. Median titers of cerebrospinal fluid specimens before and after treatment were 128 and 128, respectively; mean geometric titers of these specimens before and after treatment were 102 and 204, respectively. Median titers of the serum specimens before and after treatment were 16 and 512, respectively; mean geometric titers of these specimens before and after treatment were 19 and 631, respectively. The modified latex agglutination test did not detect antigen in any of 50 cerebrospinal fluid and 51 serum specimens from patients not suspected of having cryptococcosis. These results suggest that the pronase modification increases the sensitivity of the latex agglutination test and that the modification be routinely incorporated into it.
Identification of mycobacteria from culture by using the Gen-Probe Rapid Diagnostic System for Mycobacterium avium complex and Mycobacterium tuberculosis complex
Musial, C E, Tice, L S, Stockman, L, Roberts, Glenn D.

Journal of Clinical Microbiology | January 5, 2020 | Volume: 26 | Issue: 10 | Pages: 2120-2123

10.1128/jcm.26.10.2120-2123.1988 Get It

Commercially available kits (Mycobacterium avium Complex Rapid Diagnostic System and Mycobacterium tuberculosis Complex Rapid Diagnostic System; Gen-Probe, Inc., San Diego, Calif.) utilizing nucleic acid hybridization for the rapid identification of members of the M. avium-M. intracellulare complex and M. tuberculosis complex were evaluated by using 339 clinical and American Type Culture Collection (Rockville, Md.) isolates. The tests, which can be performed in approximately 2 h, use specific [125I]DNA probes complementary to the rRNAs of M. avium, M. intracellulare, and M. tuberculosis complex, the latter of which includes M. tuberculosis, M. bovis, M. bovis BCG, M. africanum, and M. microti. The M. avium-M. intracellulare probes correctly identified 99 of 114 M. avium-M. intracellulare isolates, with 7 false-negatives and 8 false-positives, for a sensitivity of 93.4% and a specificity of 96.6%. After repeat testing, 110 of 114 were correctly identified, with 4 false-negatives and no false-positives, for a sensitivity of 96.5% and a specificity of 100%. The M. tuberculosis complex probe correctly identified 99 of 102 M. tuberculosis isolates, with 1 false-negative and 2 false-positives, for a sensitivity of 99% and a specificity of 99.2%. After repeat testing, 100 of 102 isolates were correctly identified, with no false-negatives and 2 false-positives, for a sensitivity of 100% and a specificity of 99.2%. Overall, there were 15 discrepant M. avium-M. intracellulare results, with 4 such results after repeat testing, and 3 discrepant M. tuberculosis complex results, with 2 such results after repeat testing. The Gen-Probe kits are highly sensitive and specific for use in identifying M. avium-M. intracellulare complex and M. tuberculosis complex isolates and will be useful in the clinical laboratory which can use the present radionuclide-containing kits cost effectively.
Identification of Clinical Isolates of Mycobacteria with Gas-Liquid Chromatography Alone
Tisdall, Philip A., Roberts, Glenn D., Anhalt, John P.

Journal of Clinical Microbiology | January 5, 2020 | Volume: 10 | Issue: 4 | Pages: 506-514

10.1128/jcm.10.4.506-514.1979 Get It

Identification of 18 mycobacterial species was performed by analysis of profiles obtained by using gas-liquid chromatography. Organisms were saponified in methanolic NaOH, and the reaction mixture was treated with BF 3 in methanol and extracted with a hexane-chloroform mixture. An identification scheme was developed from 128 stock strains and tested against a collection of 79 clinical isolates. By using gas-liquid chromatographic profiles alone, 58% of specimens were correctly identified to species level, and an additional 41% were correctly identified to a group of two or three organisms. Use in a clinical laboratory over a 2-month period proved chromatography to be as accurate as and more rapid than concurrent biochemical testing. Of 81 isolates tested, 64% were identified to species level by chromatography alone. An additional 35% were differentiated to the same groups of two or three organisms as found in our analysis of stock strains. These groups consisted of: Mycobacterium tuberculosis, M. bovis , and M. xenopi; M. avium complex, M. gastri , and M. scrofulaceum ; or M. fortuitum and M. chelonei. Identification to species level from these groups could usually be done by colonial morphology alone and could always be done by the addition of one selected biochemical test. This study demonstrated the practical application of gas-liquid chromatography in the identification of mycobacteria in a clinical laboratory. In particular, all strains of M. gordonae and M. kansasii were identified to species level. M. tuberculosis was definitively identified in 85% of cases. When it could not be definitely identified, the only alternatives were M. bovis and M. xenopi , both of which are rare causes of infection.