Clinical comparison of BACTEC 9240 plus aerobic/F resin bottles and the isolator aerobic culture system for detection of bloodstream infections
Cockerill, Franklin R., Reed, G S, Torgerson, C A, Vetter, Emily A., Harmsen, William S. , Dale, J C, Roberts, Glenn D., Ilstrup, D M, Henry, Nancy K., Hughes, J G

Journal of Clinical Microbiology | January 6, 2020 | Volume: 35 | Issue: 6 | Pages: 1469-1472

10.1128/jcm.35.6.1469-1472.1997 Get It

The Plus Aerobic/F resin bottle of the BACTEC 9240 automated blood culture system (Becton Dickinson Diagnostic Instrument Systems, Sparks, Md.) was compared with aerobic culture of the Isolator system (Wampole Laboratories, Cranbury, N.J.) for the detection of bloodstream microorganisms from 6,145 blood cultures collected from adult patients with suspected septicemia. The BACTEC resin bottles were incubated for 7 days, and the sediment from the Isolator tube was inoculated to sheep blood and chocolate agars which were incubated for 72 h and to inhibitory mold, brain heart infusion, and Sabouraud agars which were incubated for 21 days. A total of 622 microorganisms were recovered from 583 blood cultures. The BACTEC resin bottle recovered statistically significantly more pathogens overall than the Isolator system (P = 0.0006). When individual pathogens isolated from either system for a 7-day study period were assessed, it was determined that the BACTEC resin bottle detected statistically significantly more isolates of Staphylococcus aureus (P = 0.0113) and coagulase-negative Staphylococcus spp. (P = 0.0029) than the Isolator system. The BACTEC resin bottle also detected statistically significantly more bloodstream infections (septic episodes) caused by coagulase-negative Staphylococcus spp. (P = 0.0146). The Isolator system recovered statistically significantly more contaminants overall (P < 0.0001), and among this group of microorganisms, recovered statistically significantly more Bacillus spp. (P < 0.0001), coagulase-negative Staphylococcus spp. (P < 0.0001), and viridans group Streptococcus spp. (P = 0.0156). The Isolator system detected statistically significantly more isolates of Histoplasma capsulatum (P = 0.004), but all of these isolates were detected at > or = 7 days of incubation of fungal plates, i.e., after the system to system comparison study period (7 days). In blood culture sets which produced growth of the same pathogen in both systems, there was a statistically significant difference in median time to detection for all pathogens combined favoring the BACTEC resin bottle over the Isolator tube (P < 0.05). When assessing individual microorganisms, the median times for detection of S. aureus, Enterococcus spp., and Pseudomonas spp. were all statistically significantly less for the BACTEC system (P < 0.05). The BACTEC instrument had 79 (1.3%) false positive signals. The BACTEC system required less processing time than the Isolator system and eliminates the hands-on time for detection of positive cultures required with the Isolator system.
Clinical comparison of difco ESP, Wampole isolator, and Becton Dickinson Septi-Chek aerobic blood culturing systems
Cockerill, Franklin R., Torgerson, C A, Reed, G S, Vetter, Emily A., Weaver, Amy L. , Dale, J C, Roberts, Glenn D., Henry, Nancy K., Ilstrup, D M, Rosenblatt, Jon E.

Journal of Clinical Microbiology | January 6, 2020 | Volume: 34 | Issue: 1 | Pages: 20-24

10.1128/jcm.34.1.20-24.1996 Get It

The ESP 80A aerobic blood culture of the ESP automated blood culture system (Difco Laboratories. Detroit, Mich.) was compared with two manual aerobic blood culture systems, the Isolator (Wampole Laboratories, Cranbury, N.J.) and the Septi-Chek (Becton Dickinson, Cockeysville, Md.) systems, for the detection of bloodstream microorganisms from 5,845 blood samples for culture collected from adult patients with suspected septicemia. The bottles were incubated for 7 days, and the sediment from the Isolator tube was inoculated onto solid medium and this medium was incubated for 72 h. A total of 609 microorganisms were recovered from 546 blood cultures. There was no statistically significant difference in the total recovery of microorganisms for the ESP 80A system when compared with that for the Septi-Chek system (P = 0.083); however, the Isolator system recovered significantly more microorganisms overall than either the ESP 80A (P < 0.001) or the Septi-Chek (P < 0.001) system. When assessing individual probable pathogens, the Isolator system detected statistically significantly more Staphylococcus aureus and Candida spp. than either the ESP 80A or the Septi-Chek system (P < 0.05). Similarly, the Isolator system detected statistically significantly more bloodstream infections (septic episodes) caused by S. aureus and Candida spp. than either the ESP 80A or the Septi-Chek system (P < 0.05). In blood culture sets which produced growth of the same probable pathogens in the ESP 80A and the Isolator systems, there was no statistically significant difference in the median times to detection for all pathogens combined (P = 0.067). However, a similar comparison showed the Isolator and the ESP 80A systems to have statistically significantly shorter median detection times for all pathogens combined (P < 0.001) when they were independently compared with the Septi-Chek system. The ESP 80A system had 29 (0.5%) false-positive signals. The ESP system required less processing time than the Isolator system and eliminates the hands-on time for the detection of positive cultures required by the manual systems.
Evaluation of two rapid antigen assays, BioStar Strep A OIA and Pacific Biotech CARDS O.S., and culture for detection of group A streptococci in throat swabs
Dale, J C, Vetter, Emily A., Contezac, Joan M., Iverson, L. K., Wollan, Peter C. , Cockerill, Franklin R.

Journal of Clinical Microbiology | January 6, 2020 | Volume: 32 | Issue: 11 | Pages: 2698-2701

10.1128/jcm.32.11.2698-2701.1994 Get It

Two rapid methods, BioStar Strep A OIA (OIA; BioStar, Inc., Boulder, Colo.), an optical immunoassay, and CARDS O.S. (O.S.; Pacific Biotech, Inc., San Diego, Calif.), a color immunochromographic assay, and two culture methods, one with 5% sheep blood agar (SBA) and one with Todd-Hewitt broth (TH; Remel, Lenexa, Kans.), were evaluated for use in the detection of Streptococcus pyogenes from pharnygeal swabs. Seven hundred forty-six double swabs (Culturette II) were processed, with OIA and SBA culture performed on one swab and O.S. and SBA culture performed on the other swab. The pledget from the Culturette II was incubated overnight in TH and was subcultured onto SBA for an additional 48 h in ambient air. All beta-hemolytic streptococci from culture were tested by a direct fluorescent-antibody test (Difco Laboratories, Detroit, Mich.). Specimens with discordant fluorescent-antibody test and rapid test results were also tested by using the Streptex latex agglutination reagent (Murex Diagnostics Limited, Dartford, England). The results obtained by all testing methods were compared with a combined test result ("gold standard"), which was defined as any positive culture detected by the SBA or TH culture methods and confirmed by Streptex latex agglutination or, in the case of negative results by both culture methods, a concomitant positive result by OIA and O.S. antigen testing. Sensitivity and specificity results for each of the methods were as follows, respectively: OIA, 81.0 and 97.5%; O.S., 74.4 and 99.0%; SBA culture, 92.3 and 98.3%; and TH culture, 86.4 and 100%. Both OIA and O.S. are suitable screening methods for detecting S. pyogenes directly from throat swabs but are of insufficient sensitivity to eliminate the need for backup cultures for specimens with negative OIA and O.S. results.