Multiplex PCR detection of vanA, vanB, vanC-1, and vanC-2/3 genes in enterococci
Patel, Robin , Uhl, J. R., Kohner, Peggy C., Hopkins, Marlene K., Cockerill, F. R., Patel, Robin , Cockerill, Franklin R.

Journal of Clinical Microbiology | January 6, 2020 | Volume: 35 | Issue: 3 | Pages: 703-707

10.1128/jcm.35.3.703-707.1997 Get It

Vancomycin-resistant enterococci (VRE) are increasingly isolated from clinical specimens. One hundred clinical isolates of enterococci (E. casseliflavus/E. flavescens [n = 10], E. faecalis [n = 34], E. faecium [n = 43], E. avium [n = 1], E. gallinarum [n = 11], and E. raffinosus [n = 1]) were examined for the presence of vanA, vanB, vanC-1, and vanC-2/3 genes by a single multiplex PCR performed directly with colonies from blood agar plates. Six previously characterized VRE strains which carry either vanA, vanB, vanC-1, or vanC-2 genes were used as controls. To discriminate among van genes, the PCR amplicons were digested with MspI and were electrophoresed on agarose gels. Because of significant sequence homology between vanC-2 and vanC-3 genes, this assay is unable to discriminate these genes from each other; therefore, these are referred to as vanC-2/3 genes. PCR products were detected in 63 of the 100 clinical isolates. The restriction fragment length patterns were consistent with vanA for 10 strains, vanB for 30 strains, vanC-1 for 12 strains, vanC-2 for 6 strains, and vanA and vanC-1 for 1 strain. The vancomycin MICs for the isolates with restriction fragment length patterns consistent with vanA and vanB were all > and = 64 micrograms/ml. The vancomycin MICs for the isolates with restriction fragment length patterns consistent with vanC-1 or vanC-2 were 4 to 8 micrograms/ml. The vancomycin MICs for the isolates from which no PCR amplicons were produced were 2 to 4 micrograms/ml. A PCR product was produced in four isolates (vancomycin MICs, 4 to > 256 micrograms/ml) with restriction fragment length patterns differing from those for the control vanA, vanB, vanC-1, and vanC-2 isolates. DNA sequencing of these amplicons revealed that two of the four isolates had nucleic acid sequences which were closely related to the published sequence for the vanB gene and two had nucleic acid sequences which were closely related to the published sequence for the vanC-2 and vanC-3 genes. Multiplex PCR-restriction fragment length polymorphism appears to be a useful and convenient method for rapidly detecting and discriminating genotypes for vancomycin-resistant Enterococcus spp. in the clinical laboratory. In instances in which unusual restriction fragment patterns of PCR amplicons occur, DNA sequencing can be performed to discriminate van genotypes.
Clinical Comparison of the Treponema pallidum CAPTIA Syphilis-G Enzyme Immunoassay with the Fluorescent Treponemal Antibody Absorption Immunoglobulin G Assay for Syphilis Testing
Halling, Valerie W., Jones, Mary F. , Bestrom, Jean E., Wold, Arlo D., Rosenblatt, Jon E., Smith, Thomas F., Cockerill, F. R., Cockerill, Franklin R.

Journal of Clinical Microbiology | December 31, 2019 | Volume: 37 | Issue: 10 | Pages: 3233-3234

10.1128/jcm.37.10.3233-3234.1999 Get It

ABSTRACT Recently, a treponema-specific immunoglobulin G (IgG) enzyme immunoassay (EIA), the CAPTIA Syphilis-G (Trinity Biotech, Jamestown, N.Y.), has become available as a diagnostic test for syphilis. A total of 89 stored sera previously tested by the fluorescent treponemal antibody absorption (FTA-ABS) IgG assay were evaluated by the CAPTIA EIA. The FTA-ABS IgG procedure was performed by technologists unblinded to results of rapid plasmid reagin (RPR) testing of the same specimens. Borderline CAPTIA-positive samples (antibody indices of ≥0.650 and ≤0.900) were retested; if the second analysis produced an index of >0.900, the sample was considered positive. Thirteen of 89 (15%) samples had discrepant results. Compared to the FTA-ABS assay, the CAPTIA EIA had a sensitivity and specificity and positive and negative predictive values of 70.7, 97.9, 96.7, and 79.7%, respectively. In another analysis, discrepancies between results were resolved by repeated FTA-ABS testing (technologists were blinded to previous RPR results) and patient chart reviews. Seven CAPTIA-negative samples which were previously interpreted (unblinded) as minimally reactive by the FTA method were subsequently interpreted (blinded) as nonreactive. One other discrepant sample (CAPTIA negative and FTA-ABS positive [at an intensity of 3+], unblinded) was FTA negative with repeated testing (blinded). For the five remaining discrepant samples, chart reviews indicated that one patient (CAPTIA negative and FTA-ABS positive [minimally reactive], blinded) had possible syphilis. These five samples were also evaluated and found to be negative by another treponema-specific test, the Treponema pallidum microhemagglutination assay. Therefore, after repeated testing and chart reviews, 2 of the 89 (2%) samples had discrepant results; the adjusted sensitivity, specificity, and positive and negative predictive values were 96.7, 98.3, 96.7, and 98.3%, respectively. This study demonstrates that the CAPTIA IgG EIA is a reliable method for syphilis testing and that personnel performing tests which require subjective interpretation, like the FTA-ABS test, may be biased by RPR test results.
Fungal infections of the immunocompromised host: clinical and laboratory aspects
Musial, C E, Cockerill, F. R., Roberts, Glenn D., Cockerill, Franklin R.

Clinical Microbiology Reviews | June 2, 2016 | Volume: 1 | Issue: 4 | Pages: 349-364

10.1128/cmr.1.4.349 Get It

Fungal infections of the immunocompromised host are being seen with greater frequency than ever before. In addition, a growing list of unusual and unexpected etiologic agents presents a unique and difficult challenge to the clinician and microbiologist. The clinical manifestations of opportunistic fungal infections are often not characteristic and, in many instances, may prevent a rapid diagnosis from being made. Clinical microbiology laboratories should consider any organism as a potential etiologic agent. This requires that all fungi recovered from immunocompromised patients be thoroughly identified and reported so that their clinical significance may be assessed. This review presents a brief discussion of the clinical and laboratory aspects of some fungal infections seen in this important group of patients.
Real-Time PCR in Clinical Microbiology: Applications for Routine Laboratory Testing
Espy, Mark J., Uhl, J. R., Sloan, Lynne M., Buckwalter, Seanne P., Jones, Mary F. , Vetter, Emily A., Yao, Joseph D. , Wengenack, Nancy L. , Rosenblatt, Jon E., Cockerill, F. R., Smith, T. F., Cockerill, Franklin R.

Clinical Microbiology Reviews | July 17, 2006 | Volume: 19 | Issue: 3 | Pages: 595-595

10.1128/cmr.00022-06 Get It

Direct Detection of Legionella Species from Bronchoalveolar Lavage and Open Lung Biopsy Specimens: Comparison of LightCycler PCR, In Situ Hybridization, Direct Fluorescence Antigen Detection, and Culture
Hayden, Randall T. , Uhl, J. R., Qian, Xiang , Hopkins, Marlene K., Aubry, MC , Lloyd, Ricardo V., Cockerill, F. R., Limper, Andrew H. , Cockerill, Franklin R., Hayden, Randall T

Journal of Clinical Microbiology | July 27, 2002 | Volume: 39 | Issue: 7 | Pages: 2618-2626

10.1128/jcm.39.7.2618-2626.2001 Get It

ABSTRACT We developed a rapid thermocycling, real-time detection (also known as real-time PCR) method for the detection of Legionella species directly from clinical specimens. This method uses the LightCycler (Roche Molecular Biochemicals, Indianapolis, Ind.) and requires approximately 1 to 2 h to perform. Both a Legionella genus PCR assay and Legionella pneumophila species-specific PCR assay were designed. A total of 43 archived specimens from 35 patients were evaluated, including 19 bronchoalveolar lavage (BAL) specimens and 24 formalin-fixed, paraffin-embedded open lung biopsy specimens. Twenty-five of the specimens were culture-positive for Legionella (9 BAL specimens and 16 tissue specimens). BAL specimens were tested by LightCycler PCR (LC-PCR) methods and by a direct fluorescent antibody (DFA) assay, which detects L. pneumophila serogroups 1 to 6 and several other Legionella species. Tissue sections were tested by the two LC-PCR methods, by DFA, by an in situ hybridization (ISH) assay, specifically designed to detect L. pneumophila , and by Warthin-Starry (WS) staining. The results were compared to the “gold standard” method of bacterial culture. With BAL specimens the following assays yielded the indicated sensitivities and specificities, respectively: Legionella genus detection by Legionella genus LC-PCR, 100 and 100%; Legionella genus detection by DFA assay, 33 and 100%; and L. pneumophila detection by L. pneumophila species-specific LC-PCR, 100 and 100%. With open lung biopsy specimens the following assays yielded the indicated sensitivities and specificities, respectively: Legionella genus detection by LC-PCR 68.8 and 100%; Legionella genus detection by DFA assay, 44 and 100%; Legionella genus detection by WS staining, 63 and 100%; L. pneumophila species-specific detection by LC-PCR, 17 and 100%; and L. pneumophila species-specific detection by ISH, 100 and 100%. The analytical sensitivity of both LC-PCR assays was <10 CFU/reaction. LC-PCR is a reliable method for the direct detection of Legionella species from BAL specimens. The Legionella genus LC-PCR assay could be performed initially; if positive, L. pneumophila species-specific LC-PCR could then be performed (if species differentiation is desired). The speed with which the LC-PCR procedure can be performed offers significant advantages over both culture-based methods and conventional PCR techniques. In contrast, for the methods evaluated, culture was the best for detecting multiple Legionella species in lung tissue. WS staining, Legionella genus LC-PCR, and L. pneumophila species-specific ISH were useful as rapid tests with lung tissue.
Detection of Herpes Simplex Virus DNA in Genital and Dermal Specimens by LightCycler PCR after Extraction using the IsoQuick, MagNA Pure, and BioRobot 9604 Methods
Espy, Mark J., Rys, Paul N., Wold, Arlo D., Uhl, James R., Sloan, Lynne M., Jenkins, G. Douglas , Ilstrup, Duane M., Cockerill, F. R., Patel, Robin , Rosenblatt, Jon E., Smith, Thomas F., Cockerill, Franklin R., Patel, Robin

Journal of Clinical Microbiology | July 27, 2002 | Volume: 39 | Issue: 6 | Pages: 2233-2236

10.1128/jcm.39.6.2233-2236.2001 Get It

ABSTRACT We evaluated two automated systems, MagNA Pure (Roche Molecular Biochemicals, Indianapolis, Ind.) and BioRobot 9604 (Qiagen, Inc., Chatsworth, Calif.) as effective replacements for the manual IsoQuick method (Orca Research, Inc., Bothell, Wash.) for extraction of herpes simplex virus (HSV) DNA from dermal and genital tract specimens prior to analysis by LightCycler PCR. Of 198 specimens (152 genital, 46 dermal), 92 (46.2%) were positive for HSV DNA by LightCycler PCR after automated extraction of specimens with either the MagNA Pure or BioRobot 9604 instrument. The manual IsoQuick method yielded HSV DNA (total n = 95) from three additional specimens that were negative by the automated method ( P = 0.25, sign test). Although the mean numbers of LightCycler PCR cycles required to reach positivity differed statistically significantly among all three of the methods of extraction, the estimated means differed by no more than 1.5 cycles ( P < 0.05). Seventy (76%) of the 92 specimens that were LightCycler PCR positive by all three extraction methods were also positive by shell vial cell culture assay. HSV DNA was detected by a lower LightCycler PCR cycle number (26.1 cycles) in specimens culture positive for the virus than in culture-negative samples (33.3 cycles) ( P < 0.0001). The manual IsoQuick and automated MagNA Pure and BioRobot 9604 methods provide standardized, reproducible extraction of HSV DNA for LightCycler PCR. The decision to implement a manual versus an automated procedure depends on factors such as costs related to the number of specimens processed rather than on the minimal differences in the technical efficiency of extraction of nucleic acids among these methods.