Back to Authors

Uhl, James R.

Mayo Clinic

Mayo Clinic

Citations 24

Spectromicroscopy of microbial signatures within human calcifications
Miller, Virginia M. , Uhl, James R., Cockerill, Franklin R., Farell‐Baril, Gerard, Tyliszczak, Tolek , Brown, Gordon E. , Benzerara, Karim , Lieske, John C.

The FASEB Journal | June 21, 2021 | Volume: 20 | Issue: 4 | Pages: No page available

10.1096/fasebj.20.4.a101-a Get It

The microbiologic nature of self‐replicating, calcifying entity nanoparticles (NPs) isolated from calcified human tissues, including blood vessels and kidney stones is debated because of the difficulty in discriminating minerals precipitated on microbes from minerals nucleated on macromolecules and cell membranes. To begin to resolve this controversy, calcifying bacteria of aquatic origin ( Caulobacter crescentus ) and NPs cultured from human samples were examined using a Scanning Transmission X‐ray Microscope (STXM). The monochromated soft X‐ray beam (150–2000 eV) produced by synchrotron radiation yields microscopic and spectroscopic information on both organic compounds and minerals at the 25 nm scale. High‐spatial and energy resolution Near‐Edge X‐ray Absorption Fine Structure (NEXAFS) spectra indicative of elemental speciation acquired at the C K‐edge and Ca L 2,3 ‐edge on a single‐cell scale from calcified C. crescentus displayed a unique spectral signature different from non‐biologic hydroxyapatite (Ca 10 (PO 4 ) 6 (OH) 2 ). Preliminary NEXAFS measurements of calcium and carbon functional groups of cultured NPs revealed organics associated with hydroxyapatite minerals and in one case, spectroscopic signatures similar to those identified in C. crescentus . Using NEXAFS, it is possible to define a biochemical signature of proteins, polysaccharides, nucleic acids, and hydroxyapatite for cultured calcified bacteria suggesting that NPs isolated from human samples share spectroscopic characteristics with calcifying bacteria.
Frequency of Isolation of Staphylococcus lugdunensis among Staphylococcal Isolates Causing Endocarditis: a 20-Year Experience
Patel, Robin , Piper, Kerryl E., Rouse, Mark S., Uhl, James R., Cockerill, Franklin R., Steckelberg, James M., Patel, Robin

Journal of Clinical Microbiology | December 31, 2019 | Volume: 38 | Issue: 11 | Pages: 4262-4263

10.1128/jcm.38.11.4262-4263.2000 Get It

ABSTRACT Eighty-nine staphylococcal isolates recovered from patients with bacterial endocarditis at the Mayo Clinic from 1980 to 1999 were studied to determine the prevalence of Staphylococcus lugdunensis among clinical isolates of staphylococci causing endocarditis. Four isolates, all from patients with native mitral valve endocarditis, were identified as S. lugdunensis .
Evaluation of LightCycler PCR for Implementation of Laboratory Diagnosis of Herpes Simplex Virus Infections
Espy, Mark J., Ross, Teri K., Teo, Rosaline, Svien, Kathleen A., Wold, Arlo D., Uhl, James R., Smith, Thomas F.

Journal of Clinical Microbiology | December 31, 2019 | Volume: 38 | Issue: 8 | Pages: 3116-3118

10.1128/jcm.38.8.3116-3118.2000 Get It

ABSTRACT Five hundred specimens (288 genital, 192 dermal, and 20 ocular) were extracted by technologists, and the DNA was assayed by LightCycler PCR (DNA polymerase and thymidine kinase [TK] gene targets) and by conventional tube and shell vial cell culture. One hundred fifty-eight confirmed (by cell culture and TK target PCR) positive and LightCycler-positive specimens were detected during the first 30 PCR cycles. LightCycler PCR-positive results for cycles 31 to 45 (39 of 67 [58.2%]) required confirmation by another PCR target (TK). LightCycler PCR is more sensitive ( n = 197; 23.1%) than cell cultures ( n = 150) for the routine laboratory detection of herpes simplex virus infections.
Diagnosis of Herpes Simplex Virus Infections in the Clinical Laboratory by LightCycler PCR
Espy, Mark J., Uhl, James R., Mitchell, P. Shawn, Thorvilson, Jill N., Svien, Kathleen A., Wold, Arlo D., Smith, Thomas F.

Journal of Clinical Microbiology | December 31, 2019 | Volume: 38 | Issue: 2 | Pages: 795-799

10.1128/jcm.38.2.795-799.2000 Get It

ABSTRACT Herpes simplex virus (HSV) causes several clinical manifestations in both normal and immunocompromised hosts; this agent is the most frequently detected virus in diagnostic laboratories. Recovery of the virus in cell culture is considered the “gold standard” for detection of this virus from sources other than cerebrospinal fluid. LightCycler is a newly developed, commercially available system designed to rapidly perform PCR, with real-time detection of PCR products by a fluorescence resonance energy transfer assay. We compared the detection of HSV for 200 specimens (number of genital specimens, 160; number of dermal specimens, 38; number of ocular specimens, 2) by shell vial cell cultures (MRC-5) and by LightCycler PCR. Of a total of 88 (44%) HSV strains detected, 69 (78%) were detected by both shell vial cell cultures and LightCycler PCR (DNA polymerase target). A total of 19 (22%) specimens were detected exclusively by LightCycler PCR. No specimens were positive by the shell vial assay only. All 19 discrepant samples had HSV DNA detected by an independent PCR directed to the thymidine kinase gene of the virus. The melting curve analysis feature of the LightCycler instrument identified identical genotype results for HSV type 1 (HSV-1) and HSV-2 from 84 of 88 (96%) positive samples. Specimens can be extracted, target HSV DNA can be amplified, and HSV PCR products can be identified by genotype within 2 h after receipt of specimen into the laboratory. The increased level of accurate identification (all 88 positive samples) compared with that of shell vial cell culture (69 of 88 samples identified as positive) and the agreement of LightCycler PCR results with all shell vial positive results indicate the potential for routine implementation of this technology for laboratory diagnosis of HSV infections.
Phenotypic and Genotypic Characterization of Staphylococcus aureus Bloodstream Isolates in a Single Large Medical Center in Southeastern Minnesota
Park, Kyung‐Hwa , Greenwood‐Quaintance, Kerryl E. , Schmidt, Suzannah M., Uhl, James R., Rajagopalan, Govindarajan , Patel, Robin

Open Forum Infectious Diseases | February 3, 2017 | Volume: 3 | Issue: suppl_1 | Pages: No page available

10.1093/ofid/ofw172.771 Get It

Fifteen-Minute Detection of Streptococcus pyogenes in Throat Swabs by Use of a Commercially Available Point-of-Care PCR Assay
Uhl, James R., Patel, Robin , Patel, Robin

Journal of Clinical Microbiology | January 14, 2016 | Volume: 54 | Issue: 3 | Pages: 815-815

10.1128/jcm.03387-15 Get It

Fusobacterium-Positive and Streptococcal-Positive Pharyngitis
Uhl, James R., Gustafson, Daniel R., Rucinski, Stefanea L., Patel, Robin , Patel, Robin

Annals of Internal Medicine | June 15, 2015 | Volume: 162 | Issue: 12 | Pages: 876-877

10.7326/l15-5099-2 Get It

Long-Term Care Facilities Are Reservoirs for Antimicrobial-Resistant Sequence Type 131 Escherichia coli
Burgess, Mary Jo , Johnson, James R. , Porter, Stephen B. , Johnston, Brian , Clabots, Connie, Lahr, Brian D. , Uhl, James R., Banerjee, Ritu

Open Forum Infectious Diseases | January 21, 2015 | Volume: 2 | Issue: 1 | Pages: No page available

10.1093/ofid/ofv011 Get It

Abstract Background. Emerging data implicate long-term care facilities (LTCFs) as reservoirs of fluoroquinolone-resistant (FQ-R) Escherichia coli of sequence type 131 (ST131). We screened for ST131 among LTCF residents, characterized isolates molecularly, and identified risk factors for colonization. Methods. We conducted a cross-sectional study using a single perianal swab or stool sample per resident in 2 LTCFs in Olmsted County, Minnesota, from April to July 2013. Confirmed FQ-R E. coli isolates underwent polymerase chain reaction-based phylotyping, detection of ST131 and its H30 and H30-Rx subclones, extended virulence genotyping, and pulsed-field gel electrophoresis (PFGE) analysis. Epidemiological data were collected from medical records. Results. Of 133 fecal samples, 33 (25%) yielded FQ-R E. coli, 32 (97%) of which were ST131. The overall proportion with ST131 intestinal colonization was 32 of 133 (24%), which differed by facility: 17 of 41 (42%) in facility 1 vs 15 of 92 (16%) in facility 2 (P = .002). All ST131 isolates represented the H30 subclone, with virulence gene and PFGE profiles resembling those of previously described ST131 clinical isolates. By PFGE, certain isolates clustered both within and across LTCFs. Multivariable predictors of ST131 colonization included inability to sign consent (odds ratio [OR], 4.16 [P = .005]), decubitus ulcer (OR, 4.87 [ P = .04]), and fecal incontinence (OR, 2.59 [P = .06]). Conclusions. Approximately one fourth of LTCF residents carried FQ-R ST131 E. coli resembling ST131 clinical isolates. Pulsed-field gel electrophoresis suggested intra- and interfacility transmission. The identified risk factors suggest that LTCF residents who require increased nursing care are at greatest risk for ST131 colonization, possibly due to healthcare-associated transmission.
Equal Performance of Self-Collected and Health Care Worker-Collected Pharyngeal Swabs for Group A Streptococcus Testing by PCR
Murray, Martha A. , Schulz, Lorie A., Furst, Joseph W. , Homme, Jason H. , Jenkins, Sarah M. , Uhl, James R., Patel, Robin , Cockerill, Franklin C., Myers, Jane F., Pritt, Bobbi S. , Patel, Robin , Pritt, Bobbi S

Journal of Clinical Microbiology | December 10, 2014 | Volume: 53 | Issue: 2 | Pages: 573-578

10.1128/jcm.02500-14 Get It

ABSTRACT A process employing patient- or parent-collected pharyngeal swabs for group A Streptococcus (GAS) testing would expedite diagnosis and treatment, reduce patient exposure to the health care setting, and decrease health care costs. Our aim was to determine the concordance between patient- or parent-collected (self-collected) and health care worker (HCW)-collected pharyngeal swabs for detection of GAS by PCR. From 9 October 2012 to 21 March 2013, patients presenting with a sore throat meeting criteria for GAS testing and not meeting criteria for severe disease were offered the opportunity to collect their own pharyngeal swab. The HCW also collected a swab. Paired swabs were tested by GAS real-time PCR, allowing semiquantitative comparisons between positive results. Of the 402 participants, 206 had a swab collected by the patient and 196 a swab collected by the parent. The percent positivity results were 33.3% for HCW-collected swabs and 34.3% for self-collected swabs ( P = 0.41). The overall concordance between the two collection strategies was 94.0% (95% confidence interval [CI], 91.3 to 96.0). Twenty-four of the paired swabs had discordant results, with 10 and 14 positives detected only with the HCW- and self-collected swabs, respectively ( P = 0.41). The person collecting the swab in the self-collected arm, the order of collection, and prior swab collection training did not influence results. Among the 124 specimens that were positive by both collection methods, the amount of GAS DNA was higher in the self-collected versus the HCW-collected swabs ( P = 0.008). Self-collected pharyngeal swabs provide a reliable alternative to HCW collection for detection of GAS and offer a strategy for improved health care delivery.
Detection of Prosthetic Joint Infection by Use of PCR-Electrospray Ionization Mass Spectrometry Applied to Synovial Fluid
Melendez, Dante P. , Uhl, James R., Greenwood‐Quaintance, Kerryl E. , Hanssen, Arlen D. , Sampath, Rangarajan , Patel, Robin , Patel, Robin

Journal of Clinical Microbiology | April 10, 2014 | Volume: 52 | Issue: 6 | Pages: 2202-2205

10.1128/jcm.00570-14 Get It

ABSTRACT PCR coupled with electrospray ionization mass spectrometry applied to synovial fluid specimens had an 81% sensitivity and a 95% specificity for the diagnosis of prosthetic joint infection.