Back to Authors

Bestrom, Jean E.

Mayo Clinic

Mayo Clinic

Citations 3

Clinical Comparison of the Treponema pallidum CAPTIA Syphilis-G Enzyme Immunoassay with the Fluorescent Treponemal Antibody Absorption Immunoglobulin G Assay for Syphilis Testing
Halling, Valerie W., Jones, Mary F. , Bestrom, Jean E., Wold, Arlo D., Rosenblatt, Jon E., Smith, Thomas F., Cockerill, F. R., Cockerill, Franklin R.

Journal of Clinical Microbiology | December 31, 2019 | Volume: 37 | Issue: 10 | Pages: 3233-3234

10.1128/jcm.37.10.3233-3234.1999 Get It

ABSTRACT Recently, a treponema-specific immunoglobulin G (IgG) enzyme immunoassay (EIA), the CAPTIA Syphilis-G (Trinity Biotech, Jamestown, N.Y.), has become available as a diagnostic test for syphilis. A total of 89 stored sera previously tested by the fluorescent treponemal antibody absorption (FTA-ABS) IgG assay were evaluated by the CAPTIA EIA. The FTA-ABS IgG procedure was performed by technologists unblinded to results of rapid plasmid reagin (RPR) testing of the same specimens. Borderline CAPTIA-positive samples (antibody indices of ≥0.650 and ≤0.900) were retested; if the second analysis produced an index of >0.900, the sample was considered positive. Thirteen of 89 (15%) samples had discrepant results. Compared to the FTA-ABS assay, the CAPTIA EIA had a sensitivity and specificity and positive and negative predictive values of 70.7, 97.9, 96.7, and 79.7%, respectively. In another analysis, discrepancies between results were resolved by repeated FTA-ABS testing (technologists were blinded to previous RPR results) and patient chart reviews. Seven CAPTIA-negative samples which were previously interpreted (unblinded) as minimally reactive by the FTA method were subsequently interpreted (blinded) as nonreactive. One other discrepant sample (CAPTIA negative and FTA-ABS positive [at an intensity of 3+], unblinded) was FTA negative with repeated testing (blinded). For the five remaining discrepant samples, chart reviews indicated that one patient (CAPTIA negative and FTA-ABS positive [minimally reactive], blinded) had possible syphilis. These five samples were also evaluated and found to be negative by another treponema-specific test, the Treponema pallidum microhemagglutination assay. Therefore, after repeated testing and chart reviews, 2 of the 89 (2%) samples had discrepant results; the adjusted sensitivity, specificity, and positive and negative predictive values were 96.7, 98.3, 96.7, and 98.3%, respectively. This study demonstrates that the CAPTIA IgG EIA is a reliable method for syphilis testing and that personnel performing tests which require subjective interpretation, like the FTA-ABS test, may be biased by RPR test results.
Reevaluation of Commercial Reagents for Detection of Histoplasma capsulatum Antigen in Urine
Theel, Elitza S. , Harring, Julie, Dababneh, Ala S. , Rollins, Leonard O., Bestrom, Jeannie E., Jespersen, Deborah J., Harring, Julie A, Bestrom, Jean E.

Journal of Clinical Microbiology | January 29, 2015 | Volume: 53 | Issue: 4 | Pages: 1198-1203

10.1128/jcm.03175-14 Get It

ABSTRACT Detection of the Histoplasma capsulatum urinary antigen (UAg) is among the most sensitive and rapid means to diagnose histoplasmosis. Previously, we evaluated analyte-specific reagents (ASR) manufactured by IMMY (Norman, OK) for detection of Histoplasma galactomannan (GM) in urine using an enzyme immunoassay (EIA), and we showed low positive agreement (64.5%) with the MiraVista (MVista) Histoplasma antigen (Ag) quantitative EIA (MiraVista Diagnostics, Indianapolis, IN). Here we reevaluated the IMMY GM ASR following modification of our original assay protocol and introduction of an indeterminate range. A total of 150 prospectively collected urine samples were tested with both the IMMY and MVista EIAs, and clinical histories were recorded for all study subjects. The IMMY GM ASR showed positive and negative agreements of 82.3% (14/17 samples) and 100% (121/121 samples), respectively (with exclusion of 12 indeterminate results), and overall agreement of 90% (135/150 samples) with respect to the MVista EIA. Of the three patients with negative IMMY GM ASR results and positive MVista EIA results, testing was performed for initial diagnostic purposes for one patient (<0.4 ng/ml by the MVista EIA) and UAg levels were being monitored for the remaining two patients (both <0.7 ng/ml by the MVista EIA). The MVista EIA results were positive for 6/12 samples that tested indeterminate by the IMMY GM ASR. We also show that the IMMY GM ASR can be used to serially monitor Histoplasma UAg levels. In conclusion, we demonstrate that, with modification, the IMMY GM ASR is a reliable rapid assay for detection of Histoplasma UAg.
Comparison of Four Assays for the Detection of Cryptococcal Antigen
Binnicker, M. J., Jespersen, Deborah J., Bestrom, Jean E., Rollins, Leonard O.

Clinical and Vaccine Immunology | October 18, 2012 | Volume: 19 | Issue: 12 | Pages: 1988-1990

10.1128/cvi.00446-12 Get It

ABSTRACT We compared the performance of four assays for the detection of cryptococcal antigen in serum samples ( n = 634) and cerebrospinal fluid (CSF) samples ( n = 51). Compared to latex agglutination, the sensitivity and specificity of the Premier enzyme immunoassay (EIA), Alpha CrAg EIA, and CrAg lateral flow assay (LFA) were 55.6 and 100%, 100 and 99.7%, and 100 and 99.8%, respectively, from serum samples. There was 100% agreement among the four tests for CSF samples, with 18 samples testing positive by each of the assays.