Comparison of agar dilution, broth microdilution, E-test, disk diffusion, and automated Vitek methods for testing susceptibilities of Enterococcus spp. to vancomycin
An evaluation was undertaken to determine the optimal method for testing the susceptibilities of 100 clinical isolates and two reference strains of Enterococcus spp. to vancomycin in vitro. Six testing methods were studied by using the following media and incubation times: agar screen with the Synergy Quad Plate (Remel, Lenexa, Kans.), an in-house-prepared brain heart infusion (BHI) agar plate, and an in-house-prepared Mueller-Hinton (MH) agar plate, all incubated for 24 or 48 h; broth microdilution (Sensititre Just One Strip; AccuMed International, Inc., West Lake, Ohio) with BHI or cation-adjusted MH broth incubated for 24 or 48 h; agar dilution with BHI or MH agar incubated for 24 or 48 h; epsilometer test (E test; AB BioDisk, Solna, Sweden) with BHI or MH agar incubated for 24 or 48 h; disk diffusion with BHI or MH agar incubated for 24 or 48 h; and the automated Vitek method with the gram-positive susceptibility Staphylococcus aureus card and R02.03 software (bioMerieux, Inc., Hazelwood, Mo.). Growth failures occurred with MH media (n = 6) but not with BHI media. One growth failure occurred with the Vitek method. Results for each testing method for each Enterococcus strain were interpreted as susceptible, intermediate, or resistant according to current National Committee for Clinical Laboratory Standards (NCCLS) criteria and compared to the vancomycin resistance genotype (i.e., vanA, vanB, vanC-1, or vanC-2/3). For all methods, extension of the incubation time from 24 h to 48 h either produced no difference in the results or gave poorer results. The following methods produced no very major or major interpretive errors: broth microdilution with BHI media incubated for 24 h, agar dilution with BHI media incubated for 24 or 48 h, and E test with BHI media incubated for 24 or 48 h. Unacceptable frequencies of very major errors (> 1%) occurred with all methods for which MH media were used. Minor interpretive errors were frequent with all methods. These minor interpretive errors also occurred most frequently with Enterococcus strains with vanC genes, which encoded low-level vancomycin resistance (MIC < or = 8 microg/ml), as opposed to Enterococcus strains which possessed vanA or vanB genes, which encoded higher-level vancomycin resistance (MIC > or = 64 microg/ml). Modification of NCCLS breakpoints, especially for motile Enterococcus spp. (E. casseliflavus, E. flavescens, and E. gallinarum), may resolve this problem; however, in the current study, one E. faecalis strain and one E. faecium strain carried only the vanC gene. The agar screen method may also require reformulation. The current agar screen plate contains 6 microg of vancomycin per ml, which may not detect all low-level resistance associated with vanC genotypes. Nevertheless, the clinical significance of this low-level vancomycin resistance remains unknown.
Multiplex PCR detection of vanA, vanB, vanC-1, and vanC-2/3 genes in enterococci
Vancomycin-resistant enterococci (VRE) are increasingly isolated from clinical specimens. One hundred clinical isolates of enterococci (E. casseliflavus/E. flavescens [n = 10], E. faecalis [n = 34], E. faecium [n = 43], E. avium [n = 1], E. gallinarum [n = 11], and E. raffinosus [n = 1]) were examined for the presence of vanA, vanB, vanC-1, and vanC-2/3 genes by a single multiplex PCR performed directly with colonies from blood agar plates. Six previously characterized VRE strains which carry either vanA, vanB, vanC-1, or vanC-2 genes were used as controls. To discriminate among van genes, the PCR amplicons were digested with MspI and were electrophoresed on agarose gels. Because of significant sequence homology between vanC-2 and vanC-3 genes, this assay is unable to discriminate these genes from each other; therefore, these are referred to as vanC-2/3 genes. PCR products were detected in 63 of the 100 clinical isolates. The restriction fragment length patterns were consistent with vanA for 10 strains, vanB for 30 strains, vanC-1 for 12 strains, vanC-2 for 6 strains, and vanA and vanC-1 for 1 strain. The vancomycin MICs for the isolates with restriction fragment length patterns consistent with vanA and vanB were all > and = 64 micrograms/ml. The vancomycin MICs for the isolates with restriction fragment length patterns consistent with vanC-1 or vanC-2 were 4 to 8 micrograms/ml. The vancomycin MICs for the isolates from which no PCR amplicons were produced were 2 to 4 micrograms/ml. A PCR product was produced in four isolates (vancomycin MICs, 4 to > 256 micrograms/ml) with restriction fragment length patterns differing from those for the control vanA, vanB, vanC-1, and vanC-2 isolates. DNA sequencing of these amplicons revealed that two of the four isolates had nucleic acid sequences which were closely related to the published sequence for the vanB gene and two had nucleic acid sequences which were closely related to the published sequence for the vanC-2 and vanC-3 genes. Multiplex PCR-restriction fragment length polymorphism appears to be a useful and convenient method for rapidly detecting and discriminating genotypes for vancomycin-resistant Enterococcus spp. in the clinical laboratory. In instances in which unusual restriction fragment patterns of PCR amplicons occur, DNA sequencing can be performed to discriminate van genotypes.
Multiplex PCR for identification of methicillin-resistant staphylococci in the clinical laboratory
A multiplex PCR assay for detection of the staphylococcal mecA gene (the structural gene for penicillin-binding protein 2a) was compared with agar dilution and disk diffusion susceptibility test methods for identifying methicillin resistance. The multiplex PCR assay combined two primer sets (mecA and 16S rRNA) in a single reaction. A total of 500 staphylococcal isolates (228 isolates of Staphylococcus aureus and 272 isolates of coagulase-negative staphylococci) from clinical specimens were studied. For S. aureus, 40 of 40 mecA-positive isolates and 4 of 188 mecA-negative isolates were oxacillin resistant (positive and negative predictive values of 100 and 98%, respectively). In 3 of 4 discordant isolates, resistance was due to hyperproduction of beta-lactamase. For coagulase-negative staphylococci, 148 of 159 mecA-positive isolates and 0 of 113 mecA-negative isolates were oxacillin resistant (positive and negative predictive values of 93 and 100%, respectively). Twenty-six isolates were categorized as indeterminate because of the absence of a detectable 16S rRNA product. Four of these 26 isolates contained mecA when retested. The assay is designed to be incorporated into the work flow of the clinical microbiology laboratory and allows for the identification of intrinsic resistance in a timely and reliable manner.
Comparison of Susceptibility Testing Methods with
mecA
Gene Analysis for Determining Oxacillin (Methicillin) Resistance in Clinical Isolates of
Staphylococcus aureus
and Coagulase-Negative
ABSTRACT Ninety-nine clinical staphylococcal isolates (58 coagulase-negative Staphylococcus spp. [CoNS] and 41 Staphylococcus aureus isolates) were evaluated for susceptibility to oxacillin. The following susceptibility testing methods, media, and incubation conditions were studied: agar dilution by using Mueller-Hinton (MH) medium (Difco) supplemented with either 0, 2, or 4% NaCl and incubation at 30 or 35°C in ambient air for 24 or 48 h; disk diffusion by using commercially prepared MH medium (Difco) and MH II agar (BBL) and incubation at 35°C in ambient air for 24 or 48 h; and agar screen (spot or swab inoculation) by using commercially prepared agar (Remel) or MH agar (Difco) prepared in-house, each containing 4% NaCl and 6 μg of oxacillin/ml (0.6-μg/ml oxacillin was also studied with MH agar prepared in-house for the agar swab method and CoNS isolates) and incubation at 35°C in ambient air for 24 or 48 h for swab inoculation and at 30 or 35°C in ambient air for 24 or 48 h for spot inoculation. The results for these methods were compared to the results for mecA gene detection by a PCR method. Given the ability to support growth and the results for susceptibility testing (the breakpoint for susceptible isolates was ≤2 μg/ml), the best methods for CoNS isolates were (i) agar dilution by using MH medium supplemented with 4% NaCl and incubation at 35°C for 48 h (no growth failures were noted, and sensitivity was 97.6%) and (ii) agar screen (swab inoculation) by using MH medium prepared in-house supplemented with 4% NaCl and containing 0.6 μg oxacillin/ml and incubation at 35°C for 48 h (one isolate that did not carry the mecA gene did not grow, and the sensitivity was 100%). All but one (agar dilution without added NaCl and incubation at 30°C for 48 h) of the methods tested revealed all oxacillin-resistant S. aureus isolates, and no growth failures occurred with any method. If the breakpoint for susceptibility was lowered to ≤1 μg/ml for agar dilution methods, more CoNS isolates with oxacillin resistance related to the mecA gene were detected when 0 or 2% NaCl agar supplementation was used. Only one CoNS isolate with mecA gene-associated resistance was not detected by using agar dilution and MH medium supplemented with 4% NaCl with incubation for 48 h. When the breakpoint for susceptibility was decreased 10-fold (from 6.0 to 0.6 μg of oxacillin per ml) for the agar swab screen method, fully 100% of the CoNS isolates that carried the mecA gene were identified.
Determination of 16S rRNA Sequences of Enterococci and Application to Species Identification of Nonmotile
Enterococcus gallinarum
Isolates
ABSTRACT The 16S rRNA sequences of enterococcal species E. faecium , E. faecalis , E. gallinarum , E. casseliflavus/flavescens , E. dispar , E. pseudoavium , E. sulfureus , E. malodoratus , E. raffinosus , E. cecorum , E. hirae , E. saccharolyticus , E. seriolicida , E. mundtii , E. avium , E. durans , E. columbae , and E. solitarius are presented herein. These data were utilized to confirm the species identification of two nonmotile E. gallinarum isolates which had been previously phenotypically identified as E. faecium . The implications of this finding are discussed.
DNA Sequence Variation within
vanA
,
vanB
,
vanC-1
, and
vanC-2/3
Genes of Clinical
Enterococcus
Isol
ABSTRACT We studied the DNA sequence variation of van genes of 34 isolates of Enterococcus spp. The isolates containing the vanB gene exhibited between 0 and 41 base pair changes per 801 bp studied when the vanB sequences were compared to that of the reference strain Enterococcus faecalis V583. The isolates carrying the vanC-2 gene exhibited between 0 and 23 base pair changes per 346 bp studied when the vanC-2 sequences were compared to that of the reference strain E. casseliflavus ATCC 25788. Little variation was noted in the vanA and vanC-1 genes.
Inhibition Controls for Qualitative Real-Time PCR Assays: Are They Necessary for All Specimen Matrices?
ABSTRACT A retrospective analysis of 386,706 specimens representing a variety of matrix types used in qualitative real-time PCR assays determined the overall inhibition rate to be 0.87% when the inhibition control was added preextraction to 5,613 specimens and 0.01% when the inhibition control was added postextraction but preamplification in 381,093 specimens. Inhibition rates of ≤1% were found for all specimen matrix types except urine and formalin-fixed, paraffin-embedded tissue.
Real-Time PCR in Clinical Microbiology: Applications for Routine Laboratory Testing
SUMMARY Real-time PCR has revolutionized the way clinical microbiology laboratories diagnose many human microbial infections. This testing method combines PCR chemistry with fluorescent probe detection of amplified product in the same reaction vessel. In general, both PCR and amplified product detection are completed in an hour or less, which is considerably faster than conventional PCR detection methods. Real-time PCR assays provide sensitivity and specificity equivalent to that of conventional PCR combined with Southern blot analysis, and since amplification and detection steps are performed in the same closed vessel, the risk of releasing amplified nucleic acids into the environment is negligible. The combination of excellent sensitivity and specificity, low contamination risk, and speed has made real-time PCR technology an appealing alternative to culture- or immunoassay-based testing methods for diagnosing many infectious diseases. This review focuses on the application of real-time PCR in the clinical microbiology laboratory.
Comparison of Specimen Processing and Nucleic Acid Extraction by the Swab Extraction Tube System versus the MagNA Pure LC System for Laboratory Diagnosis of Herpes Simplex Virus Infections by LightCycler PCR
ABSTRACT A total of 563 specimens (234 dermal and 329 genital swabs) from patients suspected of having herpes simplex virus (HSV) infections were processed using two different extraction methods (the MagNA Pure LC system and the swab extraction tube system [SETS]); HSV DNA was amplified by LightCycler PCR. HSV DNA was detected in 157 of 563 specimens (27.9%) processed by the MagNA Pure LC system and in 179 of 563 specimens (31.8%) processed by SETS ( P < 0.0001). There was no specimen processed by the MagNA Pure LC extraction method that was positive only for HSV DNA. Of 157 specimens positive by both methods, HSV DNA copy levels were higher (using cycle crossover points [cycle threshold { C T }]) with SETS (mean C T , 25.9 cycles) than with the MagNA Pure LC system (mean C T , 32.0 cycles) ( P < 0.0001). The time to process 32 samples was longer with the MagNA Pure LC extraction system (90 min) than with SETS (35 min). HSV DNA extraction using SETS is faster, less expensive, and more sensitive than the MagNA Pure LC system and could replace the latter for the laboratory diagnosis of HSV infections using LightCycler PCR.