ABSTRACT Identification of coryneform bacteria to the species level is important in certain circumstances for differentiating contamination and/or colonization from infection, which influences decisions regarding clinical intervention. However, methods currently used in clinical microbiology laboratories for the species identification of coryneform bacteria are often inadequate. We evaluated the MicroSeq 500 16S bacterial sequencing kit (Perkin-Elmer Biosystems, Foster City, Calif.), which is designed to sequence the first 527 bp of the 16S rRNA gene for bacterial identification, by using 52 coryneform gram-positive bacilli from clinical specimens isolated from January through June 1993 at the Mayo Clinic. Compared to conventional and supplemented phenotypic methods, MicroSeq provided concordant results for identification to the genus level for all isolates. At the species level, MicroSeq provided concordant results for 27 of 42 (64.3%) Corynebacterium isolates and 5 of 6 (83.3%) Corynebacterium -related isolates, respectively. Within the Corynebacterium genus, MicroSeq gave identical species-level identifications for the clinically significant Corynebacterium diphtheriae (4 of 4) and Corynebacterium jeikeium (8 of 8), but it identified only 50.0% (15 of 30) of other species ( P < 0.01). Four isolates from the genera Arthrobacter , Brevibacterium , and Microbacterium , which could not be identified to the species level by conventional methods, were assigned a species-level identification by MicroSeq. The total elapsed time for running a MicroSeq identification was 15.5 to 18.5 h. These data demonstrate that the MicroSeq 500 16S bacterial sequencing kit provides a potentially powerful method for the definitive identification of clinical coryneform bacterium isolates.
Comparison of Susceptibility Testing Methods with
mecA
Gene Analysis for Determining Oxacillin (Methicillin) Resistance in Clinical Isolates of
Staphylococcus aureus
and Coagulase-Negative
ABSTRACT Ninety-nine clinical staphylococcal isolates (58 coagulase-negative Staphylococcus spp. [CoNS] and 41 Staphylococcus aureus isolates) were evaluated for susceptibility to oxacillin. The following susceptibility testing methods, media, and incubation conditions were studied: agar dilution by using Mueller-Hinton (MH) medium (Difco) supplemented with either 0, 2, or 4% NaCl and incubation at 30 or 35°C in ambient air for 24 or 48 h; disk diffusion by using commercially prepared MH medium (Difco) and MH II agar (BBL) and incubation at 35°C in ambient air for 24 or 48 h; and agar screen (spot or swab inoculation) by using commercially prepared agar (Remel) or MH agar (Difco) prepared in-house, each containing 4% NaCl and 6 μg of oxacillin/ml (0.6-μg/ml oxacillin was also studied with MH agar prepared in-house for the agar swab method and CoNS isolates) and incubation at 35°C in ambient air for 24 or 48 h for swab inoculation and at 30 or 35°C in ambient air for 24 or 48 h for spot inoculation. The results for these methods were compared to the results for mecA gene detection by a PCR method. Given the ability to support growth and the results for susceptibility testing (the breakpoint for susceptible isolates was ≤2 μg/ml), the best methods for CoNS isolates were (i) agar dilution by using MH medium supplemented with 4% NaCl and incubation at 35°C for 48 h (no growth failures were noted, and sensitivity was 97.6%) and (ii) agar screen (swab inoculation) by using MH medium prepared in-house supplemented with 4% NaCl and containing 0.6 μg oxacillin/ml and incubation at 35°C for 48 h (one isolate that did not carry the mecA gene did not grow, and the sensitivity was 100%). All but one (agar dilution without added NaCl and incubation at 30°C for 48 h) of the methods tested revealed all oxacillin-resistant S. aureus isolates, and no growth failures occurred with any method. If the breakpoint for susceptibility was lowered to ≤1 μg/ml for agar dilution methods, more CoNS isolates with oxacillin resistance related to the mecA gene were detected when 0 or 2% NaCl agar supplementation was used. Only one CoNS isolate with mecA gene-associated resistance was not detected by using agar dilution and MH medium supplemented with 4% NaCl with incubation for 48 h. When the breakpoint for susceptibility was decreased 10-fold (from 6.0 to 0.6 μg of oxacillin per ml) for the agar swab screen method, fully 100% of the CoNS isolates that carried the mecA gene were identified.
Microarray Technologies for Gene Transcript Analysis in Pancreatic Cancer
Pancreatic cancer is a devastating condition that is most often characterized by a poor prognosis. Microarray technologies are promising screening methods for the identification of potential markers for early diagnosis and chemotherapeutic intervention. In this article, we review the current state of pancreatic cancer research as it relates to the measurement of gene transcript levels by DNA microarray analysis.
Intra-articular decorin influences the fibrosis genetic expression profile in a rabbit model of joint contracture
Objectives The goal of this study was to determine whether intra-articular administration of the potentially anti-fibrotic agent decorin influences the expression of genes involved in the fibrotic cascade, and ultimately leads to less contracture, in an animal model. Methods A total of 18 rabbits underwent an operation on their right knees to form contractures. Six limbs in group 1 received four intra-articular injections of decorin; six limbs in group 2 received four intra-articular injections of bovine serum albumin (BSA) over eight days; six limbs in group 3 received no injections. The contracted limbs of rabbits in group 1 were biomechanically and genetically compared with the contracted limbs of rabbits in groups 2 and 3, with the use of a calibrated joint measuring device and custom microarray, respectively. Results There was no statistical difference in the flexion contracture angles between those limbs that received intra-articular decorin versus those that received intra-articular BSA (66° vs 69°; p = 0.41). Likewise, there was no statistical difference between those limbs that received intra-articular decorin versus those who had no injection (66° vs 72°; p = 0.27). When compared with BSA, decorin led to a statistically significant increase in the mRNA expression of 12 genes (p < 0.01). In addition, there was a statistical change in the mRNA expression of three genes, when compared with those without injection. Conclusions In this model, when administered intra-articularly at eight weeks, 2 mg of decorin had no significant effect on joint contractures. However, our genetic analysis revealed a significant alteration in several fibrotic genes. Cite this article: Bone Joint Res 2014;3:82–8.