Back to Authors

Manahan, Janice M.

Mayo Clinic

Mayo Clinic

Citations 3

Comparison of Protein A Gene Sequencing with Pulsed-Field Gel Electrophoresis and Epidemiologic Data for Molecular Typing of Methicillin-Resistant Staphylococcus aureus
Waddington, Michael, Smith, Douglas H. , Manahan, Janice M., Kohner, Peggy C., Highsmith, Leanne M., Li, Haijing , Cockerill, Franklin R., Thompson, Rodney L., Montgomery, Stacy O., Persing, David H., Tang, Yi‐Wei

Journal of Clinical Microbiology | December 31, 2019 | Volume: 38 | Issue: 4 | Pages: 1347-1351

10.1128/jcm.38.4.1347-1351.2000 Get It

ABSTRACT The epidemiologic relatedness of methicillin-resistant Staphylococcus aureus (MRSA) isolates is currently determined by analysis of chromosomal DNA restriction patterns by pulsed-field gel electrophoresis (PFGE). We have evaluated an alternative typing system (MicroSeq StaphTrack Kit; Perkin-Elmer Biosystems) based on the sequence analysis of the chromosomally encoded polymorphic repeat X region of the S. aureus protein A ( spa ) gene. A total of 69 clinical MRSA isolates were divided into 18 groups according to the number and nucleotide sequences of the spa repeats. Molecular typing results obtained both by spa sequencing and from the PFGE patterns were concordant except for one group, which contained 20 isolates recovered over a 2-year period from hospitalized patients at the Mayo Clinic. Although the spa typing patterns were indistinguishable for those isolates, PFGE analysis yielded seven related but distinguishable patterns. Further coagulase gene sequence analysis subtyped those 20 strains into four groups which followed distinct temporal and geographic distributions. During a 2-year epidemic period there were up to 7 fragment changes in PFGE patterns among epidemiologically related isolates, suggesting that PFGE may be unsuitable for long-term typing of strains involved in epidemics. Although more limited than PFGE in discriminatory power, spa sequencing analysis could be used as a screening method for typing of MRSA strains because of the shorter turnaround time, ease of use, and the inherent advantages of sequence analysis, storage, and sharing of information.
Hospital rules-based system: The next generation of medical informatics for patient safety
Wilson, John , Oyen, Lance J., Ou, Narith N., McMahon, M. Molly , Thompson, Rodney L., Manahan, Janice M., Graner, Kevin, Lovely, Jenna K. , Estes, Lynn L.

American Journal of Health-System Pharmacy | January 25, 2019 | Volume: 62 | Issue: 5 | Pages: 499-505

10.1093/ajhp/62.5.499 Get It

Comparison of the Roche LightCycler vanA / vanB Detection Assay and Culture for Detection of Vancomycin-Resistant Enterococci from Perianal Swabs
Sloan, Lynne M., Uhl, J. R., Vetter, Emily A., Schleck, Cathy D. , Harmsen, William S. , Manahan, Janice M., Thompson, Roger, Rosenblatt, Jon E., Cockerill, Franklin R.

Journal of Clinical Microbiology | June 7, 2004 | Volume: 42 | Issue: 6 | Pages: 2636-2643

10.1128/jcm.42.6.2636-2643.2004 Get It

ABSTRACT We compared the performance characteristics of a real-time PCR method, the LightCycler vanA / vanB detection assay (Roche Diagnostics Corporation, Indianapolis, Ind.) to that of Enterococcosel agar (BBL, Sparks, Md.) for direct detection of vancomycin-resistant enterococci (VRE) from 894 perianal stool swabs. For 421 of 894 swabs, the result for LightCycler PCR was compared to an Enterococcosel plate containing vancomycin at 6 μg/ml; for the remaining 473 swabs, the result for LightCycler PCR was compared to an Enterococcosel plate containing 8 μg/ml vancomycin. The LightCycler method produced considerably more positive results than either the Enterococcosel plate containing vancomycin at 6 μg/ml ( n = 25 versus n = 11; sensitivity, 100%; specificity, 97%; positive predictive value [PPV], 42%; negative predictive value [NPV], 100%) or the Enterococcosel plate containing vancomycin at 8 μg/ml ( n = 31 versus n = 10; sensitivity, 100%; specificity, 95%; PPV, 32%; NPV, 100%). When possible, additional testing, including culture, LightCycler PCR, and/or a conventional PCR method (PCR-restriction fragment length polymorphism assay), were performed on either the original specimens or original cultures or subsequent specimens for cases in which the original specimen was positive by LightCycler PCR but the Enterococcosel plate was negative. This additional testing demonstrated positive results for 7 of 14 (50%) evaluable discordant specimens which initially tested as LightCycler PCR positive but culture negative using the Enterococcosel plate containing vancomycin at 6 μg/ml and 12 of 17 (71%) evaluable discordant specimens which initially tested as LightCycler positive but culture negative using the Enterococcosel plate containing vancomycin at (8 μg/ml). These results demonstrate that the LightCycler VRE detection assay is considerably more sensitive than the standard culture method for detecting VRE directly from perianal swab specimens. The LightCycler assay also provides results much faster than culture (∼3.5 versus ≥72 h). The use of this test could have important implications for the effective control and prevention of nosocomial outbreaks of VRE.